The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody
Open accessAbstract
Geometrically enhanced differential immunocapture (GEDI) and an antibody for prostate-specific membrane antigen (PSMA) are used for high-efficiency and high-purity capture of prostate circulating tumor cells from peripheral whole blood samples of castrate-resistant prostate cancer patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
de Bono, J. S., Scher, H. I., Montgomery, R. B., Parker, C., Miller, M. C., Tissing, H., Doyle, G. V., Terstappen, L. W. W. M., Pienta, K. J., & Raghavan, D. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-0872 · Cited by 2,182
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Chang, S. S., Reuter, V. E., Heston, W. D. W., Bander, N. H., Grauer, L. S., & Gaudin, P. B. (1999) · PubMed · Cited by 825
Self-citationDetection and characterization of carcinoma cells in the blood
Racila, E., Euhus, D., Weiss, A. J., Rao, C., McConnell, J., Terstappen, L. W. M. M., & Uhr, J. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4589 · Cited by 712
Circulating Tumor Cell Number and Prognosis in Progressive Castration-Resistant Prostate Cancer
Danila, D. C., Heller, G., Gignac, G. A., Gonzalez-Espinoza, R., Anand, A., Tanaka, E., Lilja, H., Schwartz, L., Larson, S., Fleisher, M., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-1506 · Cited by 665
Scher, H. I., Jia, X., de Bono, J. S., Fleisher, M., Pienta, K. J., Raghavan, D., & Heller, G. (2009) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70340-1 · Cited by 611
Zheng, S., Lin, H., Liu, J.-Q., Balic, M., Datar, R., Cote, R. J., & Tai, Y.-C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.064 · Cited by 599
Adams, A. A., Okagbare, P. I., Feng, J., Hupert, M. L., Patterson, D., Göttert, J., McCarley, R. L., Nikitopoulos, D., Murphy, M. C., & Soper, S. A. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8015022 · Cited by 521
Cited by
Isolation and retrieval of circulating tumor cells using centrifugal forces
Hou, H. W., Warkiani, M. E., Khoo, B. L., Li, Z. R., Soo, R. A., Tan, D. S.-W., Lim, W.-T., Han, J., Bhagat, A. A. S., & Lim, C. T. (2013) · Scientific Reports · doi:10.1038/srep01259 · Cited by 736
Wang, S., Liu, K., Liu, J., Yu, Z. T. ‐., Xu, X., Zhao, L., Lee, T., Lee, E. K., Reiss, J., Lee, Y., et al. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201005853 · Cited by 620
Slanted spiral microfluidics for the ultra-fast, label-free isolation of circulating tumor cells
Warkiani, M. E., Guan, G., Luan, K. B., Lee, W. C., Bhagat, A. A. S., Kant Chaudhuri, P., Tan, D. S.-W., Lim, W. T., Lee, S. C., Chen, P. C. Y., et al. (2014) · Lab Chip · doi:10.1039/c3lc50617g · Cited by 573
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics
Warkiani, M. E., Khoo, B. L., Wu, L., Tay, A. K. P., Bhagat, A. A. S., Han, J., & Lim, C. T. (2016) · Nature Protocols · doi:10.1038/nprot.2016.003 · Cited by 548
Size-selective collection of circulating tumor cells using Vortex technology
Sollier, E., Go, D. E., Che, J., Gossett, D. R., O'Byrne, S., Weaver, W. M., Kummer, N., Rettig, M., Goldman, J., Nickols, N., et al. (2014) · Lab Chip · doi:10.1039/c3lc50689d · Cited by 498
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Heitzer, E., Ulz, P., Belic, J., Gutschi, S., Quehenberger, F., Fischereder, K., Benezeder, T., Auer, M., Pischler, C., Mannweiler, S., et al. (2013) · Genome Medicine · doi:10.1186/gm434 · Cited by 357
Technologies for circulating tumor cell separation from whole blood
Bankó, P., Lee, S. Y., Nagygyörgy, V., Zrínyi, M., Chae, C. H., Cho, D. H., & Telekes, A. (2019) · Journal of Hematology & Oncology · doi:10.1186/s13045-019-0735-4 · Cited by 358
Detecting Circulating Tumor Cells: Current Challenges and New Trends
Hong, B., & Zu, Y. (2013) · Theranostics · doi:10.7150/thno.5195 · Cited by 351
Bhagat, A. A. S., Hou, H. W., Li, L. D., Lim, C. T., & Han, J. (2011) · Lab on a Chip · doi:10.1039/c0lc00633e · Cited by 350
Size-Selective Microcavity Array for Rapid and Efficient Detection of Circulating Tumor Cells
Hosokawa, M., Hayata, T., Fukuda, Y., Arakaki, A., Yoshino, T., Tanaka, T., & Matsunaga, T. (2010) · Analytical Chemistry · doi:10.1021/ac101222x · Cited by 344
Fundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
Biology, vulnerabilities and clinical applications of circulating tumour cells
Ring, A., Nguyen-Sträuli, B. D., Wicki, A., & Aceto, N. (2023) · Nature Reviews Cancer · doi:10.1038/s41568-022-00536-4 · Cited by 327
Rare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Specific Capture and Release of Circulating Tumor Cells Using Aptamer‐Modified Nanosubstrates
Shen, Q., Xu, L., Zhao, L., Wu, D., Fan, Y., Zhou, Y., OuYang, W., Xu, X., Zhang, Z., Song, M., et al. (2013) · Advanced Materials · doi:10.1002/adma.201300082 · Cited by 300
Engineering and physical sciences in oncology: challenges and opportunities
Mitchell, M. J., Jain, R. K., & Langer, R. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.83 · Cited by 273
Capture and Stimulated Release of Circulating Tumor Cells on Polymer‐Grafted Silicon Nanostructures
Hou, S., Zhao, H., Zhao, L., Shen, Q., Wei, K. S., Suh, D. Y., Nakao, A., Garcia, M. A., Song, M., Lee, T., et al. (2013) · Advanced Materials · doi:10.1002/adma.201203185 · Cited by 260
Sheng, W., Ogunwobi, O. O., Chen, T., Zhang, J., George, T. J., Liu, C., & Fan, Z. H. (2014) · Lab Chip · doi:10.1039/c3lc51017d · Cited by 257
Expansion of CTCs from early stage lung cancer patients using a microfluidic co-culture model
Zhang, Z., Shiratsuchi, H., Lin, J., Chen, G., Reddy, R. M., Azizi, E., Fouladdel, S., Chang, A. C., Lin, L., Jiang, H., et al. (2014) · Oncotarget · doi:10.18632/oncotarget.2592 · Cited by 207
Unger, C., Kramer, N., Walzl, A., Scherzer, M., Hengstschläger, M., & Dolznig, H. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.10.015 · Cited by 158
Separation and detection of rare cells in a microfluidic disk via negative selection
Chen, C.-L., Chen, K.-C., Pan, Y.-C., Lee, T.-P., Hsiung, L.-C., Lin, C.-M., Chen, C.-Y., Lin, C.-H., Chiang, B.-L., & Wo, A. M. (2011) · Lab Chip · doi:10.1039/c0lc00332h · Cited by 72
Recent advances in microfluidic methods in cancer liquid biopsy
Iliescu, F. S., Poenar, D. P., Yu, F., Ni, M., Chan, K. H., Cima, I., Taylor, H. K., Cima, I., & Iliescu, C. (2019) · Biomicrofluidics · doi:10.1063/1.5087690 · Cited by 51
Rethinking liquid biopsy: Microfluidic assays for mobile tumor cells in human body fluids
Neoh, K. H., Hassan, A. A., Chen, A., Sun, Y., Liu, P., Xu, K.-F., Wong, A. S. T., & Han, R. P. S. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.006 · Cited by 44
Metadata
- Authors
- Gleghorn, J. P., Pratt, E. D., Denning, D., Liu, H., Bander, N. H., Tagawa, S. T., Nanus, D. M., Giannakakou, P. A., & Kirby, B. J.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 1
- Pages
- 27-29
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2158027291
- Cited by
- 396
- References
- 14
- FWCI
- 13.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.