The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Pinched flow coupled shear-modulated inertial microfluidics for high-throughput rare blood cell separation
Abstract
Blood is a highly complex bio-fluid with cellular components making up >40% of the total volume, thus making its analysis challenging and time-consuming. In this work, we introduce a high-throughput size-based separation method for processing diluted blood using inertial microfluidics. The technique takes advantage of the preferential cell focusing in high aspect-ratio microchannels coupled with pinched flow dynamics for isolating low abundance cells from blood. As an application of the developed technique, we demonstrate the isolation of cancer cells (circulating tumor cells (CTCs)) spiked in blood by exploiting the difference in size between CTCs and hematologic cells. The microchannel dimensions and processing parameters were optimized to enable high throughput and high resolution separation, comparable to existing CTC isolation technologies. Results from experiments conducted with MCF-7 cells spiked into whole blood indicate >80% cell recovery with an impressive 3.25 × 10(5) fold enrichment over red blood cells (RBCs) and 1.2 × 10(4) fold enrichment over peripheral blood leukocytes (PBL). In spite of a 20× sample dilution, the fast operating flow rate allows the processing of ∼10(8) cells min(-1) through a single microfluidic device. The device design can be easily customized for isolating other rare cells from blood including peripheral blood leukocytes and fetal nucleated red blood cells by simply varying the 'pinching' width. The advantage of simple label-free separation, combined with the ability to retrieve viable cells post enrichment and minimal sample pre-processing presents numerous applications for use in clinical diagnosis and conducting fundamental studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
The epithelial–mesenchymal transition: new insights in signaling, development, and disease
Lee, J. M., Dedhar, S., Kalluri, R., & Thompson, E. W. (2006) · The Journal of Cell Biology · doi:10.1083/jcb.200601018 · Cited by 2,019
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Isolation of Lymphocytes, Granulocytes and Macrophages
BØYUM, A. (1976) · Scandinavian Journal of Immunology · doi:10.1111/j.1365-3083.1976.tb03851.x · Cited by 1,589
Radial Particle Displacements in Poiseuille Flow of Suspensions
SEGRÉ, G., & SILBERBERG, A. (1961) · Nature · doi:10.1038/189209a0 · Cited by 1,206
Detection, clinical relevance and specific biological properties of disseminating tumour cells
Pantel, K., Brakenhoff, R. H., & Brandt, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2375 · Cited by 1,118
Isolation by Size of Epithelial Tumor Cells
Vona, G., Sabile, A., Louha, M., Sitruk, V., Romana, S., Schütze, K., Capron, F., Franco, D., Pazzagli, M., Vekemans, M., et al. (2000) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64706-2 · Cited by 1,069
Hayes, D. F., Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Miller, M. C., Matera, J., Allard, W. J., Doyle, G. V., & Terstappen, L. W. W. M. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-2821 · Cited by 1,030
Circulating tumor cells (CTC) detection: Clinical impact and future directions
Paterlini-Brechot, P., & Benali, N. L. (2007) · Cancer Letters · doi:10.1016/j.canlet.2006.12.014 · Cited by 947
Circulating Tumor Cells versus Imaging—Predicting Overall Survival in Metastatic Breast Cancer
Budd, G. T., Cristofanilli, M., Ellis, M. J., Stopeck, A., Borden, E., Miller, M. C., Matera, J., Repollet, M., Doyle, G. V., Terstappen, L. W. M. M., et al. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-1769 · Cited by 775
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Carcinoma Invasion and Metastasis: A Role for Epithelial-Mesenchymal Transition?
Thompson, E. W., & Newgreen, D. F. (2005) · Cancer Research · doi:10.1158/0008-5472.can-05-0616 · Cited by 667
Continuous particle separation in spiral microchannels using dean flows and differential migration
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2008) · Lab on a Chip · doi:10.1039/b807107a · Cited by 656
Self-citationMicrofluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Self-citationToner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Deterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622
Zheng, S., Lin, H., Liu, J.-Q., Balic, M., Datar, R., Cote, R. J., & Tai, Y.-C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.064 · Cited by 599
Adams, A. A., Okagbare, P. I., Feng, J., Hupert, M. L., Patterson, D., Göttert, J., McCarley, R. L., Nikitopoulos, D., Murphy, M. C., & Soper, S. A. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8015022 · Cited by 521
Talasaz, A. H., Powell, A. A., Huber, D. E., Berbee, J. G., Roh, K.-H., Yu, W., Xiao, W., Davis, M. M., Pease, R. F., Mindrinos, M. N., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813188106 · Cited by 480
Gleghorn, J. P., Pratt, E. D., Denning, D., Liu, H., Bander, N. H., Tagawa, S. T., Nanus, D. M., Giannakakou, P. A., & Kirby, B. J. (2010) · Lab Chip · doi:10.1039/b917959c · Cited by 396
Microdevice for the isolation and enumeration of cancer cells from blood
Tan, S. J., Yobas, L., Lee, G. Y. H., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9305-9 · Cited by 362
Self-citationStability of molded polydimethylsiloxane microstructures
Delamarche, E., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Advanced Materials · doi:10.1002/adma.19970090914 · Cited by 360
Flow-induced deformation of shallow microfluidic channels
Gervais, T., El-Ali, J., Günther, A., & Jensen, K. F. (2006) · Lab on a Chip · doi:10.1039/b513524a · Cited by 359
Size-Selective Microcavity Array for Rapid and Efficient Detection of Circulating Tumor Cells
Hosokawa, M., Hayata, T., Fukuda, Y., Arakaki, A., Yoshino, T., Tanaka, T., & Matsunaga, T. (2010) · Analytical Chemistry · doi:10.1021/ac101222x · Cited by 344
A microfluidic device for practical label-free CD4+ T cell counting of HIV-infected subjects
Cheng, X., Irimia, D., Dixon, M., Sekine, K., Demirci, U., Zamir, L., Tompkins, R. G., Rodriguez, W., & Toner, M. (2007) · Lab Chip · doi:10.1039/b612966h · Cited by 340
Inertial microfluidics for continuous particle filtration and extraction
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0377-2 · Cited by 334
Self-citationDeformability study of breast cancer cells using microfluidics
Hou, H. W., Li, Q. S., Lee, G. Y. H., Kumar, A. P., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9262-8 · Cited by 322
Self-citationMorphometry of human leukocytes
Gw, S.-S., Shih, Y., & Chien, S. (1980) · Blood · doi:10.1182/blood.v56.5.866.866 · Cited by 308
Hou, H. W., Bhagat, A. A. S., Lin Chong, A. G., Mao, P., Wei Tan, K. S., Han, J., & Lim, C. T. (2010) · Lab on a Chip · doi:10.1039/c003873c · Cited by 300
Self-citationIsolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications
Crowley, T. A., & Pizziconi, V. (2005) · Lab on a Chip · doi:10.1039/b502930a · Cited by 280
Wall-induced forces on a rigid sphere at finite Reynolds number
ZENG, L., BALACHANDAR, S., & FISCHER, P. (2005) · Journal of Fluid Mechanics · doi:10.1017/s0022112005004738 · Cited by 275
Cancer Invasion and Metastasis
Wittekind, C., & Neid, M. (2005) · Oncology · doi:10.1159/000086626 · Cited by 269
Migration of particles undergoing pressure-driven flow in a circular conduit
Hampton, R. E., Mammoli, A. A., Graham, A. L., Tetlow, N., & Altobelli, S. A. (1997) · Journal of Rheology · doi:10.1122/1.550863 · Cited by 257
High Ep-CAM Expression is Associated with Poor Prognosis in Node-positive Breast Cancer
Spizzo, G., Gastl, G., Obrist, P., Went, P., Dirnhofer, S., Bischoff, S., Mirlacher, M., Sauter, G., Simon, R., Stopatschinskaya, S., et al. (2004) · Breast Cancer Research and Treatment · doi:10.1023/b:brea.0000036787.59816.01 · Cited by 254
Park, J.-S., Song, S.-H., & Jung, H.-I. (2009) · Lab Chip · doi:10.1039/b813952k · Cited by 239
Biomimetic Autoseparation of Leukocytes from Whole Blood in a Microfluidic Device
Shevkoplyas, S. S., Yoshida, T., Munn, L. L., & Bitensky, M. W. (2005) · Analytical Chemistry · doi:10.1021/ac049037i · Cited by 225
VanDelinder, V., & Groisman, A. (2006) · Analytical Chemistry · doi:10.1021/ac060042r · Cited by 209
Isolation of tumor cells using size and deformation
Mohamed, H., Murray, M., Turner, J. N., & Caggana, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.036 · Cited by 208
Lara, O., Tong, X., Zborowski, M., & Chalmers, J. J. (2004) · Experimental Hematology · doi:10.1016/j.exphem.2004.07.007 · Cited by 199
Retention of leukocytes in capillaries: role of cell size and deformability
Downey, G. P., Doherty, D. E., Schwab, B., Elson, E. L., Henson, P. M., & Worthen, G. S. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.5.1767 · Cited by 192
Shear stress effects on human embryonic kidney cells in Vitro
Stathopoulos, N. A., & Hellums, J. D. (1985) · Biotechnology and Bioengineering · doi:10.1002/bit.260270713 · Cited by 169
De Giorgi, V., Pinzani, P., Salvianti, F., Panelos, J., Paglierani, M., Janowska, A., Grazzini, M., Wechsler, J., Orlando, C., Santucci, M., et al. (2010) · Journal of Investigative Dermatology · doi:10.1038/jid.2010.141 · Cited by 159
Case study of the morphologic variation of circulating tumor cells
Marrinucci, D. C., Bethel, K. J., Bruce, R. H., Curry, D. N., Hsieh, B. R., Humphrey, M., Krivacic, R. T., Kroener, J. F., Kroener, L. L., Ladányi, A., et al. (2006) · Human Pathology · doi:10.1016/j.humpath.2006.08.027 · Cited by 157
Park, J.-S., & Jung, H. (2009) · Analytical Chemistry · doi:10.1021/ac9005765 · Cited by 155
Deformability‐based flow cytometry
Lincoln, B., Erickson, H. M., Schinkinger, S., Wottawah, F., Mitchell, D., Ulvick, S., Bilby, C., & Guck, J. R. (2004) · Cytometry Part A · doi:10.1002/cyto.a.20050 · Cited by 147
Microsystems for the Capture of Low-Abundance Cells
Dharmasiri, U., Witek, M. A., Adams, A. A., & Soper, S. A. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073610 · Cited by 132
VanDelinder, V., & Groisman, A. (2007) · Analytical Chemistry · doi:10.1021/ac061659b · Cited by 129
The measurement and therapeutic implications of circulating tumour cells in breast cancer
Smerage, J. B., & Hayes, D. F. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602871 · Cited by 124
Estimation of disruption of animal cells by laminar shear stress
Born, C., Zhang, Z., Al‐Rubeai, M., & Thomas, C. R. (1992) · Biotechnology and Bioengineering · doi:10.1002/bit.260400903 · Cited by 122
New technologies for the detection of circulating tumour cells
Gerges, N., Rak, J. W., & Jabado, N. (2010) · British Medical Bulletin · doi:10.1093/bmb/ldq011 · Cited by 114
Altered expression of CD11b/CD18 and CD62L on human monocytes after cell preparation procedures
Lundahl, J., Halldén, G., Hallgren, M., Sköld, C. M., & HED, J. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(94)00303-e · Cited by 87
Biochip for separating fetal cells from maternal circulation
Mohamed, H., Turner, J. N., & Caggana, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.06.025 · Cited by 83
Vona, G., Béroud, C., Benachi, A., Quenette, A., Bonnefont, J., Romana, S. P., Dumez, Y., Lacour, B., & Paterlini-Bréchot, P. (2002) · American Journal Of Pathology · doi:10.1016/s0002-9440(10)64348-9 · Cited by 82
Centrifugation attenuates the fluid shear response of circulating leukocytes
Fukuda, S., & Schmid‐Schönbein, G. W. (2002) · Journal of Leukocyte Biology · doi:10.1189/jlb.72.1.133 · Cited by 70
Cited by
Isolation and retrieval of circulating tumor cells using centrifugal forces
Hou, H. W., Warkiani, M. E., Khoo, B. L., Li, Z. R., Soo, R. A., Tan, D. S.-W., Lim, W.-T., Han, J., Bhagat, A. A. S., & Lim, C. T. (2013) · Scientific Reports · doi:10.1038/srep01259 · Cited by 736
Self-citationAmini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Slanted spiral microfluidics for the ultra-fast, label-free isolation of circulating tumor cells
Warkiani, M. E., Guan, G., Luan, K. B., Lee, W. C., Bhagat, A. A. S., Kant Chaudhuri, P., Tan, D. S.-W., Lim, W. T., Lee, S. C., Chen, P. C. Y., et al. (2014) · Lab Chip · doi:10.1039/c3lc50617g · Cited by 573
Self-citationInertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Circulating Tumor Cells and Circulating Tumor DNA
Alix-Panabières, C., Schwarzenbach, H., & Pantel, K. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-062310-094219 · Cited by 485
Metadata
- Authors
- Bhagat, A. A. S., Hou, H. W., Li, L. D., Lim, C. T., & Han, J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 11
- Pages
- 1870
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2126593559
- Cited by
- 350
- References
- 57
- FWCI
- 20.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.