The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Rapid prototyping polymers for microfluidic devices and high pressure injections
Abstract
Multiple methods of fabrication exist for microfluidic devices, with different advantages depending on the end goal of industrial mass production or rapid prototyping for the research laboratory. Polydimethylsiloxane (PDMS) has been the mainstay for rapid prototyping in the academic microfluidics community, because of its low cost, robustness and straightforward fabrication, which are particularly advantageous in the exploratory stages of research. However, despite its many advantages and its broad use in academic laboratories, its low elastic modulus becomes a significant issue for high pressure operation as it leads to a large alteration of channel geometry. Among other consequences, such deformation makes it difficult to accurately predict the flow rates in complex microfluidic networks, change flow speed quickly for applications in stop-flow lithography, or to have predictable inertial focusing positions for cytometry applications where an accurate alignment of the optical system is critical. Recently, other polymers have been identified as complementary to PDMS, with similar fabrication procedures being characteristic of rapid prototyping but with higher rigidity and better resistance to solvents; Thermoset Polyester (TPE), Polyurethane Methacrylate (PUMA) and Norland Adhesive 81 (NOA81). In this review, we assess these different polymer alternatives to PDMS for rapid prototyping, especially in view of high pressure injections with the specific example of inertial flow conditions. These materials are compared to PDMS, for which magnitudes of deformation and dynamic characteristics are also characterized. We provide a complete and systematic analysis of these materials with side-by-side experiments conducted in our lab that also evaluate other properties, such as biocompatibility, solvent compatibility, and ease of fabrication. We emphasize that these polymer alternatives, TPE, PUMA and NOA, have some considerable strengths for rapid prototyping when bond strength, predictable operation at high pressure, or transitioning to commercialization are considered important for the application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Senturia, S. D. (2001) · Springer eBooks · doi:10.1007/b117574 · Cited by 2,072
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Self-citationDi Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Self-citationViscous and resistive eddies near a sharp corner
Moffatt, H. K. (1964) · Journal of Fluid Mechanics · doi:10.1017/s0022112064000015 · Cited by 1,531
(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
Chip integrated strategies for acoustic separation and manipulation of cells and particles
Laurell, T., Petersson, F., & Nilsson, A. (2007) · Chem. Soc. Rev. · doi:10.1039/b601326k · Cited by 874
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Improved Pattern Transfer in Soft Lithography Using Composite Stamps
Odom, T. W., Love, J. C., Wolfe, D. B., Paul, K. E., & Whitesides, G. M. (2002) · Langmuir · doi:10.1021/la020169l · Cited by 709
Hot embossing as a method for the fabrication of polymer high aspect ratio structures
Becker, H., & Heim, U. (2000) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(00)00296-x · Cited by 666
Deterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622
Deformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Self-citationDisposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Klank, H., Kutter, J. P., & Geschke, O. (2002) · Lab on a Chip · doi:10.1039/b206409j · Cited by 477
Bélanger, M., & Marois, Y. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1043 · Cited by 471
Stop-flow lithography in a microfluidic device
Dendukuri, D., Gu, S. S., Pregibon, D. C., Hatton, T. A., & Doyle, P. S. (2007) · Lab on a Chip · doi:10.1039/b703457a · Cited by 430
Sheathless inertial cell ordering for extreme throughput flow cytometry
Hur, S. C., Tse, H. T. K., & Di Carlo, D. (2010) · Lab Chip · doi:10.1039/b919495a · Cited by 368
Self-citationFlow-induced deformation of shallow microfluidic channels
Gervais, T., El-Ali, J., Günther, A., & Jensen, K. F. (2006) · Lab on a Chip · doi:10.1039/b513524a · Cited by 359
Inertial microfluidics for continuous particle filtration and extraction
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0377-2 · Cited by 334
High-throughput size-based rare cell enrichment using microscale vortices
Hur, S. C., Mach, A. J., & Di Carlo, D. (2011) · Biomicrofluidics · doi:10.1063/1.3576780 · Cited by 317
Self-citationChoi, K. M., & Rogers, J. A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja029973k · Cited by 309
Replica molding using polymeric materials: A practical step toward nanomanufacturing
Xia, Y., McClelland, J. J., Gupta, R., Qin, D., Zhao, X., Sohn, L. L., Celotta, R. J., & Whitesides, G. M. (1997) · Advanced Materials · doi:10.1002/adma.19970090211 · Cited by 307
Automated cellular sample preparation using a Centrifuge-on-a-Chip
Mach, A. J., Kim, J. H., Arshi, A., Hur, S. C., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20330d · Cited by 280
Self-citationBartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
The deformation of flexible PDMS microchannels under a pressure driven flow
Hardy, B. S., Uechi, K., Zhen, J., & Pirouz Kavehpour, H. (2009) · Lab Chip · doi:10.1039/b813061b · Cited by 203
Femtosecond laser ablation of polymeric substrates for the fabrication of microfluidic channels
Suriano, R., Kuznetsov, A., Eaton, S. M., Kiyan, R., Cerullo, G., Osellame, R., Chichkov, B. N., Levi, M., & Turri, S. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.02.053 · Cited by 191
Laser processing for bio-microfluidics applications (part I)
Khan Malek, C. G. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0514-2 · Cited by 190
Microfluidic channel fabrication in dry film resist for production and prototyping of hybrid chips
Vulto, P., Glade, N., Altomare, L., Bablet, J., Tin, L. D., Medoro, G., Chartier, I., Manaresi, N., Tartagni, M., & Guerrieri, R. (2005) · Lab on a Chip · doi:10.1039/b411885e · Cited by 187
Rapid Prototyping of Arrayed Microfluidic Systems in Polystyrene for Cell-Based Assays
Young, E. W. K., Berthier, E., Guckenberger, D. J., Sackmann, E., Lamers, C., Meyvantsson, I., Huttenlocher, A., & Beebe, D. J. (2011) · Analytical Chemistry · doi:10.1021/ac102897h · Cited by 172
Park, J.-S., & Jung, H. (2009) · Analytical Chemistry · doi:10.1021/ac9005765 · Cited by 155
Rapid microfabrication of solvent-resistant biocompatible microfluidic devices
Hung, L.-H., Lin, R., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b717710k · Cited by 120
Deformability considerations in filtration of biological cells
Kuo, J. S., Zhao, Y., Schiro, P. G., Ng, L., Lim, D. S. W., Shelby, J. P., & Chiu, D. T. (2010) · Lab on a Chip · doi:10.1039/b922301k · Cited by 118
Wägli, P., Homsy, A., & de Rooij, N. F. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.02.005 · Cited by 105
Fiorini, G. S., Jeffries, G. D. M., Lim, D. S. W., Kuyper, C. L., & Chiu, D. T. (2003) · Lab on a Chip · doi:10.1039/b305074m · Cited by 102
Rapid Prototyping of Thermoset Polyester Microfluidic Devices
Fiorini, G. S., Lorenz, R. M., Kuo, J. S., & Chiu, D. T. (2004) · Analytical Chemistry · doi:10.1021/ac0498922 · Cited by 102
Disposable microfluidic substrates: Transitioning from the research laboratory into the clinic
Kuo, J. S., & Chiu, D. T. (2011) · Lab on a Chip · doi:10.1039/c1lc20125e · Cited by 74
Prototyping of microfluidic systems using a commercial thermoplastic elastomer
Roy, E., Geißler, M., Galas, J.-C., & Veres, T. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-011-0789-2 · Cited by 71
A method for reducing pressure-induced deformation in silicone microfluidics
Inglis, D. W. (2010) · Biomicrofluidics · doi:10.1063/1.3431715 · Cited by 63
Cell Docking in Double Grooves in a Microfluidic Channel
Khabiry, M., Chung, B. G., HANCOCK, M. J., Soundararajan, H. C., Du, Y., Cropek, D. M., Lee, W. G., & Khademhosseini, A. (2009) · Small · doi:10.1002/smll.200801644 · Cited by 53
Lancaster, C. A., Kokoris, M. S., Nabavi, M., et al. (2005) · Methods · doi:10.1016/j.ymeth.2005.07.003 · Cited by 37
Fabrication improvements for thermoset polyester (TPE) microfluidic devices
Fiorini, G. S., Yim, M., Jeffries, G. D. M., Schiro, P. G., Mutch, S. A., Lorenz, R. M., & Chiu, D. T. (2007) · Lab on a Chip · doi:10.1039/b702548c · Cited by 37
Weaver, W. M., Dharmaraja, S., Milisavljevic, V., & Carlo, D. D. (2011) · Lab on a Chip · doi:10.1039/c0lc00414f · Cited by 31
Experimental study of the separation behavior of nanoparticles in micro- and nanochannels
Napoli, M., Atzberger, P. J., & Pennathur, S. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0647-7 · Cited by 31
Opto-electronic DNA chip-based integrated card for clinical diagnostics
Marchand, G., Broyer, P., Lanet, V., Delattre, C., Foucault, F., Menou, L., Calvas, B., Roller, D., Ginot, F., Campagnolo, R., et al. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9107-x · Cited by 13
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
Johnston, I. D., McCluskey, D. K., Tan, C. K. L., & Tracey, M. C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/3/035017 · Cited by 1,495
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Amini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Self-citationSize-selective collection of circulating tumor cells using Vortex technology
Sollier, E., Go, D. E., Che, J., Gossett, D. R., O'Byrne, S., Weaver, W. M., Kummer, N., Rettig, M., Goldman, J., Nickols, N., et al. (2014) · Lab Chip · doi:10.1039/c3lc50689d · Cited by 498
Self-citation
Metadata
- Authors
- Sollier, E., Murray, C., Maoddi, P., & Di Carlo, D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 22
- Pages
- 3752
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2027388599
- Cited by
- 407
- References
- 50
- FWCI
- 15.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.