Characterization of drug permeability in Caco-2 monolayers by mass spectrometry on a membrane-based microfluidic device
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
In this study, an integrated microfluidic device was developed for drug permeability assays with real-time online detection by a directly coupled mass spectrometer. The integrated microfluidic device contained two independent channels sandwiched by a semipermeable polycarbonate membrane for cell culture, and micro solid-phase extraction (SPE) columns for sample clean-up and concentration prior to mass spectrometry detection. Curcumin, a model drug, was delivered to an upper or bottom channel by a pressure-driven flow to mimic dynamic in vivo conditions, and it was forced to permeate into the other side channel. The concentration of curcumin permeated with time was directly detected by an electrospray ionization quadrupole time-of-flight mass spectrometer (ESI-Q-TOF MS) with high sensitivity after micro-SPE pretreatment. The total analysis time only needed about 30 min, and only 6 μL of the drug solution was required for each permeation experiment. The measured permeability of curcumin was consistent with the literature reported value. In addition, this technique offers the potential for parallelization and increasing throughput compared to conventional methods. Thus, the established platform provides a useful tool for drug permeability studies, which is crucial for drug discovery and development.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The epithelial monolayer formed in this device could be probed from both the apical and basal sides of the epithelium, and this enabled quantification of tight junction barrier function31, 32 and absorption of nutrients33 and drugs.30, 34”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [30]
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Bioavailability of curcumin: Problems and promises
Anand, P., Kunnumakkara, A. B., Newman, R. A., & Aggarwal, B. B. (2007) · Molecular Pharmaceutics · doi:10.1021/mp700113r · Cited by 5,543
Anticancer potential of curcumin: preclinical and clinical studies.
Aggarwal, B. B., Kumar, A. J., & Bharti, A. C. (2003) · PubMed · Cited by 3,017
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Artursson, P., Palm, K., & Luthman, K. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00128-9 · Cited by 1,543
Determination of drug permeability and prediction of drug absorption in Caco-2 monolayers
Hubatsch, I., Ragnarsson, E. G. E., & Artursson, P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.303 · Cited by 1,499
Yee, S. (1997) · Pharmaceutical Research · doi:10.1023/a:1012102522787 · Cited by 1,030
Chemopreventive and therapeutic effects of curcumin
Duvoix, A., Blasius, R., Delhalle, S., Schnekenburger, M., Morceau, F., Henry, E., Dicato, M., & Diederich, M. (2005) · Cancer Letters · doi:10.1016/j.canlet.2004.09.041 · Cited by 866
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Caco-2 Cell Monolayers as a Model for Drug Transport Across the Intestinal Mucosa
Hilgers, A. R., Conradi, R. A., & Burton, P. S. (1990) · Pharmaceutical Research · doi:10.1023/a:1015937605100 · Cited by 587
Research works printed but not linked: 2
- Sikanen, 2010, Mass Spectrom. Rev., 29, 351
- Aggarwal, 2003, Anticancer Res., 23, 363
Cited by
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Three-Dimensional Cell Cultures in Drug Discovery and Development
Fang, Y., & Eglen, R. M. (2017) · SLAS Discovery · doi:10.1177/1087057117696795 · Cited by 849
“The gut-on-a-chip using the Caco-2 cell layer on a porous support to separate two chambers was used to reproduce characteristic absorptive properties and the barrier function of the human intestine, enabling drug absorption studies.(66) Integrating multiple organ types into one chip, termed as body-on-a-chip, can be p…”
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Fedi, A., Vitale, C., Ponschin, G., Ayehunie, S., Fato, M., & Scaglione, S. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.05.028 · Cited by 229
Gut-on-a-chip: Current progress and future opportunities
Ashammakhi, N., Nasiri, R., Barros, N. R. D., Tebon, P., Thakor, J., Goudie, M., Shamloo, A., Martin, M. G., & Khademhosseini, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120196 · Cited by 235
Shin, W., Hinojosa, C. D., Ingber, D. E., & Kim, H. J. (2019) · iScience · doi:10.1016/j.isci.2019.04.037 · Cited by 186
Biochemical analysis on microfluidic chips
Wu, J., He, Z., Chen, Q., & Lin, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.03.013 · Cited by 162
Self-citationA multi-chamber microfluidic intestinal barrier model using Caco-2 cells for drug transport studies
Tan, H.-Y., Trier, S., Rahbek, U. L., Dufva, M., Kutter, J. P., & Andresen, T. L. (2018) · PLOS ONE · doi:10.1371/journal.pone.0197101 · Cited by 143
Microfluidics-to-mass spectrometry: A review of coupling methods and applications
Wang, X., Yi, L., Mukhitov, N., Schrell, A. M., Dhumpa, R., & Roper, M. G. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.039 · Cited by 141
Recent developments in formulation design for improving oral bioavailability of curcumin: A review
Liu, Z., Smart, J. D., & Pannala, A. S. (2020) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2020.102082 · Cited by 149
Recent advances in microfluidics combined with mass spectrometry: technologies and applications
Gao, D., Liu, H., Jiang, Y., & Lin, J. (2013) · Lab on a Chip · doi:10.1039/c3lc50449b · Cited by 147
Self-citationOrgan‐on‐a‐Chip Technology for Reproducing Multiorgan Physiology
Lee, S. H., & Sung, J. H. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700419 · Cited by 127
Gut-on-chip: Recreating human intestine in vitro
Xiang, Y., Wen, H., Yu, Y., Li, M., Fu, X., & Huang, S. (2020) · Journal of Tissue Engineering · doi:10.1177/2041731420965318 · Cited by 127
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
The emergence of 3D bioprinting in organ-on-chip systems
Fetah, K., Tebon, P., Goudie, M. J., Eichenbaum, J., Ren, L., Barros, N., Nasiri, R., Ahadian, S., Ashammakhi, N., Dokmeci, M. R., et al. (2019) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab23df · Cited by 98
The Past, Present and Future of Intestinal In Vitro Cell Systems for Drug Absorption Studies
Youhanna, S. C., & Lauschke, V. M. (2020) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2020.07.001 · Cited by 116
Zhang, Y., Ge, S., & Yu, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.09.008 · Cited by 107
Flat and microstructured polymeric membranes in organs-on-chips
Pasman, T., Grijpma, D., Stamatialis, D., & Poot, A. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0351 · Cited by 98
Lab-on-a-Chip hyphenation with mass spectrometry: strategies for bioanalytical applications
Oedit, A., Vulto, P., Ramautar, R., Lindenburg, P. W., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2014.08.009 · Cited by 96
Recent advances in microfluidic 3D cellular scaffolds for drug assays
Wu, J., Chen, Q., Liu, W., He, Z., & Lin, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.11.009 · Cited by 99
Self-citationThree-dimensional cell culture: from evolution to revolution
Alhaque, S., Themis, M., & Rashidi, H. (2018) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2017.0216 · Cited by 97
Barriers-on-chips: Measurement of barrier function of tissues in organs-on-chips
Arık, Y. B., van der Helm, M. W., Odijk, M., Segerink, L. I., Passier, R. C., van den Berg, A., & van der Meer, A. D. (2018) · Biomicrofluidics · doi:10.1063/1.5023041 · Cited by 97
The Progress of Intestinal Epithelial Models from Cell Lines to Gut-On-Chip
Rahman, S., Ghiboub, M., Donkers, J. M., van de Steeg, E., van Tol, E. A. F., Hakvoort, T. B. M., & de Jonge, W. J. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413472 · Cited by 93
Recent advances in microchip-mass spectrometry for biological analysis
He, X., Chen, Q., Zhang, Y., & Lin, J. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.09.013 · Cited by 85
Self-citationReview of membranes in microfluidics
Chen, X., & Shen, J. (2016) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.5105 · Cited by 84
Kulthong, K., Duivenvoorde, L. P. M., Sun, H., Confederat, S., Wu, J., Spenkelink, B., de Haan, L., Marin, V., van der Zande, M., & Bouwmeester, H. (2020) · Toxicology in Vitro · doi:10.1016/j.tiv.2020.104815 · Cited by 86
3D printed Lego ® -like modular microfluidic devices based on capillary driving
Nie, J., Gao, Q., Qiu, J., Sun, M., Liu, A., Shao, L., Fu, J., Zhao, P., & He, Y. (2018) · Biofabrication · doi:10.1088/1758-5090/aaadd3 · Cited by 80
Microfluidic lumen-based systems for advancing tubular organ modeling
Virumbrales-Muñoz, M., Ayuso, J. M., Gong, M. M., Humayun, M., Livingston, M. K., Lugo-Cintrón, K. M., McMinn, P., Álvarez-García, Y. R., & Beebe, D. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00705f · Cited by 76
Jing, B., Wang, Z. A., Zhang, C., Deng, Q., Wei, J., Luo, Y., Zhang, X., Li, J., & Du, Y. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00272 · Cited by 79
Ashammakhi, N. A., Darabi, M. A., Çelebi‐Saltik, B., Tutar, R., Hartel, M. C., Lee, J., Hussein, S. M., Goudie, M. J., Cornelius, M. B., Dokmeci, M. R., et al. (2019) · Small Methods · doi:10.1002/smtd.201900589 · Cited by 74
Santbergen, M. J. C., van der Zande, M., Gerssen, A., Bouwmeester, H., & Nielen, M. W. F. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02336-6 · Cited by 72
Flory, S., Sus, N., Haas, K., Jehle, S., Kienhöfer, E., Waehler, R., Adler, G., Venturelli, S., & Frank, J. (2021) · Molecular Nutrition & Food Research · doi:10.1002/mnfr.202100613 · Cited by 74
Microfluidics towards single cell resolution protein analysis
Chen, P., Chen, D., Li, S., Ou, X., & Liu, B. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.022 · Cited by 71
Organoids/organs-on-a-chip: new frontiers of intestinal pathophysiological models
Wu, L., Ai, Y., Xie, R., Xiong, J., Wang, Y., & Liang, Q. (2023) · Lab on a Chip · doi:10.1039/d2lc00804a · Cited by 69
Self-citationYouhanna, S. C., Kemas, A. M., Preiss, L. C., Zhou, Y., Shen, J. X., Cakal, S. D., Paqualini, F. S., Goparaju, S. K., Shafagh, R. Z., Lind, J. U., et al. (2022) · Pharmacological Reviews · doi:10.1124/pharmrev.120.000238 · Cited by 67
Temporal Monitoring of Differentiated Human Airway Epithelial Cells Using Microfluidics
Blume, C., Reale, R., Held, M., Millar, T. M., Collins, J. E., Davies, D. E., Morgan, H., & Swindle, E. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0139872 · Cited by 64
Driver, R., & Mishra, S. (2022) · BioChip Journal · doi:10.1007/s13206-022-00087-8 · Cited by 69
Shao, X., Gao, D., Chen, Y., Jin, F., Hu, G., Jiang, Y., & Liu, H. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.028 · Cited by 62
Self-citationEngineered Biomimetic Membranes for Organ-on-a-Chip
Rahimnejad, M., Rasouli, F., Jahangiri, S., Ahmadi, S., Rabiee, N., Farani, M. R., Akhavan, O., Asadnia, M., Fatahi, Y., Hong, S., et al. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00531 · Cited by 59
Basement membrane properties and their recapitulation in organ-on-chip applications
Salimbeigi, G., Vrana, N. E., Ghaemmaghami, A. M., Huri, P. Y., & McGuinness, G. B. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100301 · Cited by 57
Multi-organ-on-a-chip for pharmacokinetics and toxicokinetic study of drugs
Sung, J. H. (2021) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2021.1908996 · Cited by 58
Microfluidic isolation of highly pure embryonic stem cells using feeder-separated co-culture system
Chen, Q., Wu, J., Zhuang, Q., Lin, X., Zhang, J., & Lin, J. (2013) · Scientific Reports · doi:10.1038/srep02433 · Cited by 55
Self-citationMulti-channel microfluidic chip-mass spectrometry platform for cell analysis
Jie, M., Mao, S., Li, H., & Lin, J. (2017) · Chinese Chemical Letters · doi:10.1016/j.cclet.2017.05.024 · Cited by 54
Self-citationMicrofluidic approaches for epithelial cell layer culture and characterisation
Thuenauer, R., Rodriguez-Boulan, E. J., & Römer, W. (2014) · The Analyst · doi:10.1039/c4an00056k · Cited by 59
Integrated microfluidic system for cell co-culture and simulation of drug metabolism
Jie, M., Li, H.-F., Lin, L., Zhang, J., & Lin, J.-M. (2016) · RSC Advances · doi:10.1039/c6ra10407j · Cited by 54
Self-citationKulthong, K., Duivenvoorde, L. P. M., Mizera, B. Z., Rijkers, D., ten Dam, G., Oegema, G., Puzyn, T., Bouwmeester, H., & van der Zande, M. (2018) · RSC Advances · doi:10.1039/c8ra05430d · Cited by 53
Cell analysis on chip-mass spectrometry
Mao, S., Li, W., Zhang, Q., Zhang, W., Huang, Q., & Lin, J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.06.019 · Cited by 53
Self-citationEmerging Role of Organ‐on‐a‐Chip Technologies in Quantitative Clinical Pharmacology Evaluation
Isoherranen, N., Madabushi, R., & Huang, S. (2019) · Clinical and Translational Science · doi:10.1111/cts.12627 · Cited by 50
Liu, D., Jiao, S., Wei, J., Zhang, X., Pei, Y., Pei, Z., Li, J., & Du, Y. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119669 · Cited by 48
Shen, J. X., Youhanna, S., Zandi Shafagh, R., Kele, J., & Lauschke, V. M. (2020) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.9b00245 · Cited by 49
A versatile, compartmentalised gut-on-a-chip system for pharmacological and toxicological analyses
de Haan, P., Santbergen, M. J. C., van der Zande, M., Bouwmeester, H., Nielen, M. W. F., & Verpoorte, E. M. J. (2021) · Scientific Reports · doi:10.1038/s41598-021-84187-9 · Cited by 51
Online and in situ analysis of organs-on-a-chip
Santbergen, M. J. C., van der Zande, M., Bouwmeester, H., & Nielen, M. W. F. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.04.006 · Cited by 49
Zhu, L., Li, R., Jiao, S., Wei, J., Yan, Y., Wang, Z. A., Li, J., & Du, Y. (2020) · Marine Drugs · doi:10.3390/md18100488 · Cited by 48
Analytical techniques and methods for study of drug-lipid membrane interactions
Li, H., Zhao, T., & Sun, Z. (2017) · Reviews in Analytical Chemistry · doi:10.1515/revac-2017-0012 · Cited by 44
Direct Optofluidic Measurement of the Lipid Permeability of Fluoroquinolones
Cama, J., Schaich, M., Nahas, K. A., Hernández‐Ainsa, S., Pagliara, S., & Keyser, U. F. (2016) · Scientific Reports · doi:10.1038/srep32824 · Cited by 42
Gastrointestinal microphysiological systems
Blutt, S. E., Broughman, J. R., Zou, W. Y., Zeng, X., Karandikar, U. C., In, J. G., Zachos, N. C., Kovbasnjuk, O. N., Donowitz, M., & Estes, M. K. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217710638 · Cited by 43
Jie, M., Mao, S., Liu, H., He, Z., Li, H., & Lin, J. (2017) · The Analyst · doi:10.1039/c7an00453b · Cited by 41
Self-citationRapid Customization of 3D Integrated Microfluidic Chips via Modular Structure-Based Design
Qiu, J., Gao, Q., Zhao, H., Fu, J., & He, Y. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00401 · Cited by 40
Pharmacokinetics‐On‐a‐Chip: In Vitro Microphysiological Models for Emulating of Drugs ADME
Ramadan, Q., Fardous, R. S., Hazaymeh, R., Alshmmari, S. K., & Zourob, M. M. (2021) · Advanced Biology · doi:10.1002/adbi.202100775 · Cited by 42
Manufacturing methods and applications of membranes in microfluidics
Chen, X., Shen, J., Hu, Z., & Huo, X. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0130-7 · Cited by 37
Microfluidic Devices in the Fast‐Growing Domain of Single‐Cell Analysis
Khan, M., Mao, S., Li, W., & Lin, J. (2018) · Chemistry - A European Journal · doi:10.1002/chem.201800305 · Cited by 36
Self-citationOrganoids, organ-on-a-chip, separation science and mass spectrometry: An update
Kogler, S., Kømurcu, K., Olsen, C., Shoji, J.-Y., Skottvoll, F. S., Krauss, S., Wilson, S., & Ro̷berg-Larsen, H. (2023) · Trends in Analytical Chemistry (TrAC) · doi:10.1016/j.trac.2023.116996 · Cited by 27
Three-Dimensional Cell Cultures in Drug Discovery and Development
Ye, F., & Eglen, R. M. (2017) · SLAS DISCOVERY · doi:10.1177/2472555217696795 · Cited by 57
Rapid Fabrication of Membrane-Integrated Thermoplastic Elastomer Microfluidic Devices
McMillan, A. H., Thomée, E., Dellaquila, A., Nassman, H., Segura, T., & Lesher‐Pérez, S. C. (2020) · Micromachines · doi:10.3390/mi11080731 · Cited by 33
In vitro models to evaluate ingestible devices: Present status and current trends
O’Farrell, C., Stamatopoulos, K., Simmons, M. J. H., & Batchelor, H. K. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113924 · Cited by 36
Taavitsainen, S., Juuti‐Uusitalo, K., Kurppa, K., Lindfors, K., Kallio, P. J., & Kellomäki, M. (2024) · Frontiers in Lab on a Chip Technologies · doi:10.3389/frlct.2023.1337945 · Cited by 32
Jing, B., Cheng, G., Li, J., Wang, Z. A., & Du, Y. (2019) · Marine Drugs · doi:10.3390/md17070415 · Cited by 31
Donkers, J. M., van der Vaart, J. I., & van de Steeg, E. (2023) · Biomimetics · doi:10.3390/biomimetics8020226 · Cited by 30
Wu, Q., Gao, D., Wei, J., Jin, F., Xie, W., Jiang, Y., & Liu, H. (2014) · Chemical Communications · doi:10.1039/c3cc49771b · Cited by 28
Self-citationRecent Developments in Microfluidic Chip for in vitro Cell-based Research
Zhuang, Q., Ning, R., Ma, Y., & Lin, J. (2016) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(16)60919-2 · Cited by 28
Self-citationLuo, X., Wu, H., Betz, J. F., Rubloff, G. W., & Bentley, W. E. (2014) · Biochemical Engineering Journal · doi:10.1016/j.bej.2013.12.013 · Cited by 28
Advances of microfluidic intestine-on-a-chip for analyzing anti-inflammation of food
Liang, D., Su, W., & Tan, M. (2021) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2021.1875395 · Cited by 27
Flory, S., Männle, R., & Frank, J. (2021) · Antioxidants · doi:10.3390/antiox10111826 · Cited by 27
Wu, J., Zhang, B., Liu, X., Peng, L., Liu, J., Hu, Y., Ji, X., Lv, H., & Wang, S. (2023) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2023.02.013 · Cited by 26
Xu, N., Lin, H., Lin, S., Zhang, W., Han, S., Nakajima, H., Mao, S., & Lin, J. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04147 · Cited by 25
Self-citationMembrane-based microfluidic systems for medical and biological applications
Calzuola, S. T., Newman, G., Feaugas, T., Perrault, C. M., Blondé, J.-B., Roy, E., Porrini, C., Stojanović, G. M., & Vidić, J. (2024) · Lab on a Chip · doi:10.1039/d4lc00251b · Cited by 24
Development of Gut-Mucus Chip for Intestinal Absorption Study
Lee, S. Y., Lee, Y., Choi, N., Kim, H. N., Kim, B., & Sung, J. H. (2023) · BioChip Journal · doi:10.1007/s13206-023-00097-0 · Cited by 24
Technological advances for analyzing the content of organ-on-a-chip by mass spectrometry
Hadavi, D., Tosheva, I., Siegel, T. P., Cuypers, E., & Honing, M. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1197760 · Cited by 23
Biomaterial-based microfluidics for cell culture and analysis
Ning, R., Wang, F., & Lin, L. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.08.017 · Cited by 23
Qing, L., Wang, T., Luo, H.-Y., Du, J.-L., Wang, R.-Y., & Luo, P. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116832 · Cited by 24
Jing, B., Luo, Y., Lin, B., Li, J., Wang, Z. A., & Du, Y. (2019) · RSC Advances · doi:10.1039/c9ra02069a · Cited by 23
Kang, K.-J., Ju, S. M., Jang, Y., & Kim, J. (2016) · Tissue Engineering and Regenerative Medicine · doi:10.1007/s13770-016-0005-2 · Cited by 21
Trends in 3D models of inflammatory bowel disease
Ferreira, B., Barros, A. S., Pereira, C. L., Viegas, J. S. R., das Neves, J., Nunes, R., & Sarmento, B. F. C. C. (2024) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2024.167042 · Cited by 20
Peng, G., Chen, Y., Deng, R., He, Q., Liu, D., Lü, Y., & Lin, J. (2018) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2018.06.006 · Cited by 19
Self-citationSimulating the Effect of Gut Microbiome on Cancer Cell Growth Using a Microfluidic Device
Mittal, E., Cupp, G., & Kang, Y. B. (2023) · Sensors · doi:10.3390/s23031265 · Cited by 18
Singh, G., Arora, A., Rani, S., Maurya, I. K., Aulakh, D., & Wriedt, M. (2016) · RSC Advances · doi:10.1039/c6ra13949c · Cited by 18
Cell Analysis on Microfluidics Combined with Mass Spectrometry
Zhang, W., Zhang, Q., & Lin, J. (2020) · Analytical Sciences · doi:10.2116/analsci.20r006 · Cited by 18
Self-citationHu, W., Gao, D., Su, Z., Qian, R., Wang, Y., & Liang, Q. (2021) · Chinese Chemical Letters · doi:10.1016/j.cclet.2021.08.041 · Cited by 19
Self-citationWang, J., Li, H., Li, B., Gong, Q., Chen, X., & Wang, Q. (2016) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2016.3386 · Cited by 18
An Evolved Transformer Model for ADME/Tox Prediction
Shao, C., Shao, F., Huang, S., Sun, R., & Zhang, T. (2024) · Electronics · doi:10.3390/electronics13030624 · Cited by 18
Biomaterial-Based Microfluidics for Cell Culture and Analysis
Ning, R., Zhuang, Q., & Lin, J. (2017) · Integrated analytical systems · doi:10.1007/978-981-10-5394-8_6 · Cited by 16
Self-citationBorah, A., & Kumar, D. S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823966-7.00003-7 · Cited by 21
Microfluidic strategies for the blood-brain barrier construction and assessment
Yin, F., Su, W., Wang, L., & Hu, Q. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116689 · Cited by 16
Nasiri, R., Madadelahi, M., Nikmaneshi, M. R., Gökçe, B., Bijarchi, M. A., Shah, S., Tirpáková, Z., Gastel, D. V., Taebnia, N., de Barros, N. R., et al. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123739 · Cited by 19
Computational pharmacokinetic modeling of organ-on-chip devices and microphysiological systems
Przekwas, A. J., & Somayaji, M. R. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00011-5 · Cited by 15
A microdevice for parallelized pulmonary permeability studies
Bol, L., Galas, J.-C., Hillaireau, H., Potier, I. L., Nicolas, V., Haghiri‐Gosnet, A., Fattal, E., & Taverna, M. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9831-3 · Cited by 13
Three-Dimensional Scaffolds for Intestinal Cell Culture: Fabrication, Utilization, and Prospects
Liu, T., Gu, J. L., Fu, C., & Su, L. (2024) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2023.0124 · Cited by 13
Somayaji, M. R., Das, D., & Przekwas, A. J. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.11.002 · Cited by 12
Metadata
- Authors
- Gao, D., Liu, H., Lin, J.-M., Wang, Y., & Jiang, Y.
- Affiliations
- Tsinghua Shenzhen International Graduate School (CN)
- Tsinghua University (CN)
- Corresponding author
- Lin, Jin-Ming
- Jiang, Yuyang
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 5
- Pages
- 978
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2164851115
- Cited by
- 135
- References
- 40
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 8 · 2023: 11 · 2022: 12 · 2021: 13 · 2020: 14 · 2019: 14 · 2018: 13 · 2017: 15 · 2016: 14 · 2015: 4 · 2014: 5 · 2013: 4
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Keywords
- drug permeability, Caco-2 cell monolayers, intestinal permeation, microfluidics, mass spectrometry, curcumin, semipermeable membranes, solid-phase extraction, electrospray ionization, quadrupole time-of-flight
- MeSH terms
- Cell Adhesion, Cell Membrane Permeability, Cell Survival, Curcumin, Humans, Polycarboxylate Cement, Time Factors, Caco-2 Cells, Spectrometry, Mass, Electrospray Ionization, Microfluidic Analytical Techniques, Solid Phase Extraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.