The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Simple, distance-based measurement for paper analytical devices
Abstract
Paper-based analytical devices (PADs) represent a growing class of elegant, yet inexpensive chemical sensor technologies designed for point-of-use applications. Most PADs, however, still utilize some form of instrumentation such as a camera for quantitative detection. We describe here a simple technique to render PAD measurements more quantitative and straightforward using the distance of colour development as a detection motif. The so-called distance-based detection enables PAD chemistries that are more portable and less resource intensive compared to classical approaches that rely on the use of peripheral equipment for quantitative measurement. We demonstrate the utility and broad applicability of this technique with measurements of glucose, nickel, and glutathione using three different detection chemistries: enzymatic reactions, metal complexation, and nanoparticle aggregation, respectively. The results show excellent quantitative agreement with certified standards in complex sample matrices. This work provides the first demonstration of distance-based PAD detection with broad application as a class of new, inexpensive sensor technologies designed for point-of-use applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
The importance of glutathione in human disease
Townsend, D. M., Tew, K. D., & Tapiero, H. (2003) · Biomedicine & Pharmacotherapy · doi:10.1016/s0753-3322(03)00043-x · Cited by 2,004
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Li, H., & Rothberg, L. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406115101 · Cited by 1,342
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Self-citationElectrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
The role of glutathione in cancer
Balendiran, G. K., Dabur, R., & Fraser, D. (2004) · Cell Biochemistry and Function · doi:10.1002/cbf.1149 · Cited by 927
Glutathione deficiency is associated with impaired survival in HIV disease
Herzenberg, L. A., De Rosa, S. C., Dubs, J. G., Roederer, M., Anderson, M. T., Ela, S. W., Deresinski, S. C., & Herzenberg, L. A. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.5.1967 · Cited by 670
Li, & Rothberg, L. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja048749n · Cited by 663
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Merrill Jr., A. H., Sullards, M. C., Allegood, J. C., Kelly, S., & Wang, E. (2005) · Methods · doi:10.1016/j.ymeth.2005.01.009 · Cited by 594
Fan, R., Vermesh, O., Srivastava, A., Yen, B. K. H., Qin, L., Ahmad, H., Kwong, G. A., Liu, C.-C., Gould, J., Hood, L., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1507 · Cited by 539
Quantum-Dot/Aptamer-Based Ultrasensitive Multi-Analyte Electrochemical Biosensor
Hansen, J. A., Wang, J., Kawde, A.-N., Xiang, Y., Gothelf, K. V., & Collins, G. (2006) · Journal of the American Chemical Society · doi:10.1021/ja060005h · Cited by 538
Health monitoring in the home of the future
Korhonen, I., Parkka, J., & Van Gils, M. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213628 · Cited by 486
Wei, H., Li, B., Li, J., Wang, E., & Dong, S. (2007) · Chemical Communications · doi:10.1039/b707642h · Cited by 472
A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
Clarke, S. F., & Foster, J. R. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.12002443 · Cited by 456
The carcinogenicity of metals in humans
Hayes, R. B. (1997) · Cancer Causes & Control · doi:10.1023/a:1018457305212 · Cited by 419
Glutathione antioxidant system as a marker of oxidative stress in chronic renal failure
Ceballos-Picot, I., Witko-Sarsat, V., Merad-Boudia, M., Nguyen, A. T., Thévenin, M., Jaudon, M. C., Zingraff, J., Verger, C., Jingers, P., & Descamps-Latscha, B. (1996) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(96)00233-x · Cited by 396
Reliability of point-of-care testing for glucose measurement in critically ill adults*
Kanji, S., Buffie, J., Hutton, B., Bunting, P. S., Singh, A., McDonald, K., Fergusson, D., McIntyre, L. A., & Hebert, P. C. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000189939.10881.60 · Cited by 395
Mobile marketing: the role of permission and acceptance
Barnes, S. J., & Scornavacca, E. (2004) · International Journal of Mobile Communications · doi:10.1504/ijmc.2004.004663 · Cited by 365
Potentiometric sensors for trace-level analysis
Bakker, E., & Pretsch, E. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.01.003 · Cited by 356
Paper-Based Bioassays Using Gold Nanoparticle Colorimetric Probes
Zhao, W., Ali, M. M., Aguirre, S. D., Brook, M. A., & Li, Y. (2008) · Analytical Chemistry · doi:10.1021/ac801008q · Cited by 338
Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
von Lode, P. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.03.008 · Cited by 290
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie · doi:10.1002/ange.200700269 · Cited by 265
Sample Filtration, Concentration, and Separation Integrated on Microfluidic Devices
Broyles, B. S., Jacobson, S. C., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac025503x · Cited by 174
Development of a High-Throughput Automated Analyzer Using Biochip Array Technology
FitzGerald, S. P., Lamont, J. V., McConnell, R. I., & Benchikh, E. O. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.049429 · Cited by 168
Mortality and cancer incidence in Swedish battery workers exposed to cadmium and nickel.
Järup, L., Bellander, T., Hogstedt, C., & Spång, G. (1998) · Occupational and Environmental Medicine · doi:10.1136/oem.55.11.755 · Cited by 103
Integrated Microfluidic Platform for Oral Diagnostics
Herr, A. E., Hatch, A. V., Giannobile, W. V., Throckmorton, D. J., Tran, H. M., Brennan, J. S., & Singh, A. K. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.004 · Cited by 96
Stobiecka, M., Coopersmith, K. J., & Hepel, M. (2010) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2010.06.010 · Cited by 87
The role of glutathione in aging and cancer
Richie, J. P. (1992) · Experimental Gerontology · doi:10.1016/0531-5565(92)90015-r · Cited by 77
The need for new monitoring tools to implement the WFD
Dworak, T., Gonzalez, C., Laaser, C., et al. (2005) · Environmental Science & Policy · doi:10.1016/j.envsci.2005.03.007 · Cited by 65
Xu, S., He, M., Lu, Y., Li, L., Zhong, M., Zhang, Y., Wang, Y., Yu, Z., & Zhou, Z. (2011) · Journal of Pineal Research · doi:10.1111/j.1600-079x.2011.00906.x · Cited by 64
Barcode lateral flow immunochromatographic strip for prostate acid phosphatase determination
Fang, C., Chen, Z., Li, L., & Xia, J.-H. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.08.008 · Cited by 55
RESTRICTION OF THORACIC RESPIRATION AS AN AID TO ABDOMINAL PALPATION
Nicholson, N. J. (1949) · The Lancet · doi:10.1016/s0140-6736(49)90470-5 · Cited by 53
Cited by
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Self-citationReview on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Yamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Morbioli, G. G., Mazzu-Nascimento, T., Stockton, A. M., & Carrilho, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.037 · Cited by 434
Paper-based microfluidics: Simplified fabrication and assay methods
Nishat, S., Jafry, A. T., Martinez, A. W., & Awan, F. R. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129681 · Cited by 392
Metadata
- Authors
- Cate, D. M., Dungchai, W., Cunningham, J. C., Volckens, J., & Henry, C. S.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 12
- Pages
- 2397
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1978576332
- Cited by
- 348
- References
- 35
- FWCI
- 13.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.