The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Slanted spiral microfluidics for the ultra-fast, label-free isolation of circulating tumor cells
Open accessAbstract
The enumeration and characterization of circulating tumor cells (CTCs), found in the peripheral blood of cancer patients, provide a potentially accessible source for cancer diagnosis and prognosis. This work reports on a novel spiral microfluidic device with a trapezoidal cross-section for ultra-fast, label-free enrichment of CTCs from clinically relevant blood volumes. The technique utilizes the inherent Dean vortex flows present in curvilinear microchannels under continuous flow, along with inertial lift forces which focus larger CTCs against the inner wall. Using a trapezoidal cross-section as opposed to a traditional rectangular cross-section, the position of the Dean vortex core can be altered to achieve separation. Smaller hematologic components are trapped in the Dean vortices skewed towards the outer channel walls and eventually removed at the outer outlet, while the larger CTCs equilibrate near the inner channel wall and are collected from the inner outlet. By using a single spiral microchannel with one inlet and two outlets, we have successfully isolated and recovered more than 80% of the tested cancer cell line cells (MCF-7, T24 and MDA-MB-231) spiked in 7.5 mL of blood within 8 min with extremely high purity (400-680 WBCs mL(-1); ~4 log depletion of WBCs). Putative CTCs were detected and isolated from 100% of the patient samples (n = 10) with advanced stage metastatic breast and lung cancer using standard biomarkers (CK, CD45 and DAPI) with the frequencies ranging from 3-125 CTCs mL(-1). We expect this simple and elegant approach can surmount the shortcomings of traditional affinity-based CTC isolation techniques as well as enable fundamental studies on CTCs to guide treatment and enhance patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prospective identification of tumorigenic breast cancer cells
Al-Hajj, M., Wicha, M. S., Benito-Hernandez, A., Morrison, S. J., & Clarke, M. F. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0530291100 · Cited by 10,370
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Isolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Riethdorf, S., Fritsche, H., Müller, V., Rau, T., Schindlbeck, C., Rack, B., Janni, W., Coith, C., Beck, K., Jänicke, F., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-1695 · Cited by 1,338
Detection, clinical relevance and specific biological properties of disseminating tumour cells
Pantel, K., Brakenhoff, R. H., & Brandt, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2375 · Cited by 1,118
Circulating tumor cells: approaches to isolation and characterization
Yu, M., Stott, S., Toner, M., Maheswaran, S., & Haber, D. A. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201010021 · Cited by 1,089
Ozkumur, E., Shah, A. M., Ciciliano, J. C., Emmink, B. L., Miyamoto, D. T., Brachtel, E., Yu, M., Chen, P.-I., Morgan, B., Trautwein, J., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005616 · Cited by 1,086
Self-citationHayes, D. F., Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Miller, M. C., Matera, J., Allard, W. J., Doyle, G. V., & Terstappen, L. W. W. M. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-2821 · Cited by 1,030
Krebs, M. G., Sloane, R., Priest, L., Lancashire, L., Hou, J.-M., Greystoke, A., Ward, T. H., Ferraldeschi, R., Hughes, A., Clack, G., et al. (2011) · Journal of Clinical Oncology · doi:10.1200/jco.2010.28.7045 · Cited by 868
Isolation and retrieval of circulating tumor cells using centrifugal forces
Hou, H. W., Warkiani, M. E., Khoo, B. L., Li, Z. R., Soo, R. A., Tan, D. S.-W., Lim, W.-T., Han, J., Bhagat, A. A. S., & Lim, C. T. (2013) · Scientific Reports · doi:10.1038/srep01259 · Cited by 736
Self-citationInertial microfluidics for continuous particle separation in spiral microchannels
Kuntaegowdanahalli, S. S., Bhagat, A. A. S., Kumar, G., & Papautsky, I. (2009) · Lab on a Chip · doi:10.1039/b908271a · Cited by 708
Self-citationContinuous particle separation in spiral microchannels using dean flows and differential migration
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2008) · Lab on a Chip · doi:10.1039/b807107a · Cited by 656
Self-citationMicrofluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Self-citationPowell, A. A., Talasaz, A. H., Zhang, H., Coram, M. A., Reddy, A., Deng, G., Telli, M. L., Advani, R. H., Carlson, R. W., Mollick, J. A., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033788 · Cited by 531
Gleghorn, J. P., Pratt, E. D., Denning, D., Liu, H., Bander, N. H., Tagawa, S. T., Nanus, D. M., Giannakakou, P. A., & Kirby, B. J. (2010) · Lab Chip · doi:10.1039/b917959c · Cited by 396
A new device for rapid isolation by size and characterization of rare circulating tumor cells.
Desitter, I., Guerrouahen, B. S., Benali-Furet, N., Wechsler, J., Janne, P. A., Kuang, Y., Yanagita, M., Wang, L., Berkowitz, J. A., Distel, R. J., et al. (2011) · PubMed · Cited by 375
Microdevice for the isolation and enumeration of cancer cells from blood
Tan, S. J., Yobas, L., Lee, G. Y. H., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9305-9 · Cited by 362
Self-citationBhagat, A. A. S., Hou, H. W., Li, L. D., Lim, C. T., & Han, J. (2011) · Lab on a Chip · doi:10.1039/c0lc00633e · Cited by 350
Self-citationInertial microfluidics for continuous particle filtration and extraction
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0377-2 · Cited by 334
Self-citationConsiderations in the development of circulating tumor cell technology for clinical use
Parkinson, D. R., Dracopoli, N., Petty, B. G., Compton, C., Cristofanilli, M., Deisseroth, A., Hayes, D. F., Kapke, G., Kumar, P., Lee, J. S., et al. (2012) · Journal of Translational Medicine · doi:10.1186/1479-5876-10-138 · Cited by 323
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Double spiral microchannel for label-free tumor cell separation and enrichment
Sun, J., Li, M., Liu, C., Zhang, Y., Liu, D., Liu, W., Hu, G., & Jiang, X. (2012) · Lab on a Chip · doi:10.1039/c2lc40679a · Cited by 293
Guan, G., Wu, L., Bhagat, A. A., Li, Z., Chen, P. C. Y., Chao, S., Ong, C. J., & Han, J. (2013) · Scientific Reports · doi:10.1038/srep01475 · Cited by 279
Self-citationDETECTION OF DISSEMINATED TUMOR CELLS IN PERIPHERAL BLOOD
Zieglschmid, V., Hollmann, C., & Böcher, O. (2005) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360590913696 · Cited by 272
Particle Focusing Mechanisms in Curving Confined Flows
Gossett, D. R., & Carlo, D. D. (2009) · Analytical Chemistry · doi:10.1021/ac901306y · Cited by 246
Mocellin, S., Hoon, D., Ambrosi, A., Nitti, D., & Rossi, C. R. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-0823 · Cited by 217
Circulating tumour cells in breast cancer
Ring, A., Smith, I. E., & Dowsett, M. (2004) · The Lancet Oncology · doi:10.1016/s1470-2045(04)01381-6 · Cited by 196
High-throughput cell cycle synchronization using inertial forces in spiral microchannels
Lee, W. C., Bhagat, A. A. S., Huang, S., Van Vliet, K. J., Han, J., & Lim, C. T. (2011) · Lab on a Chip · doi:10.1039/c0lc00579g · Cited by 164
Self-citationCirculating tumour cells demonstrate an altered response to hypoxia and an aggressive phenotype
Ameri, K., Luong, R. H., Zhang, H., Powell, A. A., Montgomery, K. D., Espinosa, Í., Bouley, D. M., Harris, A. L., & Jeffrey, S. S. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605491 · Cited by 148
Cima, I., Yee, C. W., Iliescu, F. S., Phyo, W. M., Lim, K. H., Iliescu, C., & Tan, M. H. (2013) · Biomicrofluidics · doi:10.1063/1.4780062 · Cited by 106
Beyond trastuzumab: novel therapeutic strategies in HER2-positive metastatic breast cancer
Tsang, R. Y., & Finn, R. S. (2012) · British Journal of Cancer · doi:10.1038/bjc.2011.516 · Cited by 90
Nanotube–antibody biosensor arrays for the detection of circulating breast cancer cells
Shao, N., Wickstrom, E., & Panchapakesan, B. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/46/465101 · Cited by 77
Tong, X., Yang, L., Lang, J. C., et al. (2007) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.20177 · Cited by 57
Du, Z., Cheng, K. H., Vaughn, M. W., Collie, N. L., & Gollahon, L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-9010-x · Cited by 42
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Inertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics
Warkiani, M. E., Khoo, B. L., Wu, L., Tay, A. K. P., Bhagat, A. A. S., Han, J., & Lim, C. T. (2016) · Nature Protocols · doi:10.1038/nprot.2016.003 · Cited by 548
Self-citationCirculating tumor cell technologies
Ferreira, M. M., Ramani, V. C., & Jeffrey, S. S. (2016) · Molecular Oncology · doi:10.1016/j.molonc.2016.01.007 · Cited by 511
Metadata
- Authors
- Warkiani, M. E., Guan, G., Luan, K. B., Lee, W. C., Bhagat, A. A. S., Kant Chaudhuri, P., Tan, D. S.-W., Lim, W. T., Lee, S. C., Chen, P. C. Y., Lim, C. T., & Han, J.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 1
- Pages
- 128-137
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2097950721
- Cited by
- 573
- References
- 38
- FWCI
- 18.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.