CoChat

Wearable multifunctional sensors using printed stretchable conductors made of silver nanowires

Yao, Shanshan, Zhu, Yong · 2014 · Nanoscale

The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.

Abstract

Considerable efforts have been made to achieve highly sensitive and wearable sensors that can simultaneously detect multiple stimuli such as stretch, pressure, temperature or touch. Here we develop highly stretchable multifunctional sensors that can detect strain (up to 50%), pressure (up to ∼1.2 MPa) and finger touch with high sensitivity, fast response time (∼40 ms) and good pressure mapping function. The reported sensors utilize the capacitive sensing mechanism, where silver nanowires are used as electrodes (conductors) and Ecoflex is used as a dielectric. The silver nanowire electrodes are screen printed. Our sensors have been demonstrated for several wearable applications including monitoring thumb movement, sensing the strain of the knee joint in patellar reflex (knee-jerk) and other human motions such as walking, running and jumping from squatting, illustrating the potential utilities of such sensors in robotic systems, prosthetics, healthcare and flexible touch panels.

Overview

Integrity signals

Registry

Crossref · 10.1039/c3nr05496a

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

3 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Research works printed but not linked: 3

  1. Arshak, 2006, J. Mater. Sci.: Mater. Electron., 17, 767
  2. Barrett, 2010, Inf. Disp., 26, 16
  3. Jung, 2011, Proc. Natl. Acad. Sci. U. S. A., 108, 1789

Cited by

See all 1,028

Metadata

Authors
Yao, S., & Zhu, Y.
Affiliations
North Carolina State University (US)
Corresponding author
Zhu, Yong
Venue
Nanoscale
Published
2014
Volume
6
Issue
4
Pages
2345
ISSN
  • 2040-3364 (ISSN-L)
  • 2040-3372
OpenAlex
W2096050373
Cited by
1,028
References
36
Citations by year
2026: 32 · 2025: 44 · 2024: 49 · 2023: 70 · 2022: 91 · 2021: 96 · 2020: 127 · 2019: 155 · 2018: 129 · 2017: 78 · 2016: 75 · 2015: 61 · 2014: 21
FWCI
28.83
Type
journal article
Language
en
Open access
closed
Locations
  • Nanoscale (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation
  • U.S. Department of Energy
  • Nuclear Energy University Program
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
wearable sensors, multifunctional sensors, silver nanowires, stretchable conductors, screen printing, capacitive sensing, strain sensing, pressure sensing, tactile sensing, pressure mapping, knee-jerk reflex, human motion monitoring, flexible electronics
MeSH terms
Humans, Knee Joint, Monitoring, Physiologic, Movement, Silver, Thumb, Nanowires

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.