CoChat

Multiplexing potential of NIR resonant and non-resonant Raman reporters for bio-imaging applications

Open access

The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index; none of the 49 sources its claims cite is checked for support yet.

Abstract

Multiplexed imaging, which allows for the interrogation of multiple molecular features simultaneously, is vital for addressing numerous challenges across biomedicine. Optically unique surface-enhanced Raman scattering (SERS) nanoparticles (NPs) have the potential to serve as a vehicle to achieve highly multiplexed imaging in a single acquisition, which is non-destructive, quantitative, and simple to execute. When using laser excitation at 785 nm, which allows for a lower background from biological tissues, near infrared (NIR) dyes can be used as Raman reporters to provide high Raman signal intensity due to the resonance effect. This class of imaging agents are known as surface-enhanced resonance Raman scattering (SERRS) NPs. Investigators have predominantly utilized two classes of Raman reporters in their nanoparticle constructs for use in biomedical applications: NIR-resonant and non-resonant Raman reporters. Herein, we investigate the multiplexing potential of five non-resonant SERS: BPE, 44DP, PTT, PODT, and BMMBP, and five NIR resonant SERRS NP flavors with heptamethine cyanine dyes: DTTC, IR-770, IR-780, IR-792, and IR-797, which have been extensively used for biomedical imaging applications. Although SERRS NPs display high Raman intensities, due to their resonance properties, we observed that non-resonant SERS NP concentrations can be quantitated by the intensity of their unique emissions with higher accuracy. Spectral unmixing of five-plex mixtures revealed that the studied non-resonant SERS NPs maintain their detection limits more robustly as compared to the NIR resonant SERRS NP flavors when introducing more components into a mixture.

Overview

CoChat Summary

TL;DR

This study compares five non-resonant SERS and five NIR-resonant SERRS nanoparticle flavors for multiplexed Raman imaging under identical 785 nm conditions. Non-resonant SERS NPs showed more robust spectral unmixing at higher plexity, while NIR-resonant SERRS NPs had higher absolute Raman intensities but greater fluorescence background and spectral overlap.

Key findings

  • SERRS NPs displayed higher absolute Raman intensities, but their NIR dyes produced higher background and more crowded Raman spectra, reducing signal-to-background and detection accuracy in mixtures.
  • In five-plex spectral unmixing, SERRS NPs had a deconvolution error of 28.1(±10.3)% with R² = 0.902, versus 4.8(±1.3)% with R² = 0.999 for SERS NPs.
  • Condition-number analysis indicated a 10-fold increase in spectral unmixing error for either 3-plex SERRS NPs or 22-plex SERS NPs.
  • In five-plex dilution series, non-resonant SERS NP weight values linearly correlated with input concentration (Pearson’s r ≥ 0.995 in all cases), whereas DTTC-labeled SERRS NPs were falsely detected beyond the 1-plex LOD in mixed samples.

Methods

  • Gold nanospheres with silica coating were prepared as SERS NPs using BPE, 44DP, PTT, PODT, and BMMBP, and as SERRS NPs using heptamethine cyanine NIR dyes DTTC, IR-775/IR-770, IR-780, IR-792, and IR-797; AuNP size was 60 ± 4 nm by DLS/NTA.
  • Raman imaging used 785 nm excitation, 100 mW, 0.1 s acquisition, 0–2030 cm⁻¹ range, and 1.5 cm⁻¹ resolution; NPs were dropcast onto coffee filter paper, with dilution series from 150 pM down to 4.6 fM and reference spectra at 37.5 pM.
  • Spectral unmixing used non-negative least squares (NNLS); spectral correlation and condition numbers were calculated, and DFT calculations used B3LYP with D3 dispersion correction and 6-311++G(d,p).

Limitations

  • The paper states that fluorescence background removal is challenging for multi-component mixtures, that NIR dyes have limited availability and crowded fingerprint-region spectra, and that weak NIR-dye attraction to gold complicates silica coating.
  • Evident from the text: the comparison is limited to five reporters per class, one 785 nm excitation wavelength, and an in vitro coffee-filter-paper substrate rather than biological tissue or in vivo imaging.
  • Evident from the text: condition-number and correlation analyses used normalized reference spectra without baseline subtraction, which may affect interpretation of spectral overlap and unmixing error.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1039/d3an01298k

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 28 Not checked · 55 Own results and interpretations

51 more claims

Create a free account to see all 83 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 7
  • It may state two separate claims as one. 21

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

4 of 4

Citations

Cites

Cited by

See all 14

Metadata

Authors
Eremina, O. E., Schaefer, S., Czaja, A. T., Awad, S., Lim, M. A., & Zavaleta, C.
Affiliations
University of Southern California (US)
Corresponding author
Zavaleta, Cristina
Venue
The Analyst
Published
2023
Volume
148
Issue
23
Pages
5915-5925
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W4387729622
Cited by
14
References
60
Citations by year
2026: 7 · 2025: 5 · 2024: 2
FWCI
0.84
Type
journal article
Language
en
Open access
Locations
  • The Analyst (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Agilent Technologies
  • Alfred E. Mann Institute for Biomedical Engineering, University of Southern California
  • National Institutes of Health (R01EB03391)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
Keywords
multiplexed imaging, surface-enhanced resonance Raman scattering, surface-enhanced Raman scattering, heptamethine cyanine dyes, spectral unmixing, detection limit, bioimaging, 785 nm excitation
MeSH terms
Diagnostic Imaging, Coloring Agents, Gold, Spectrum Analysis, Raman, Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-09-28, under version 3 of the claim definition (prompt extract-v3).

A second model labelled each claim on 2026-09-28 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.