Pulse wave analysis
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
‘ Since the information which the pulse affords is of so great importance, and so often consulted, surely it must be to our advantage to appreciate fully all it tells us, and to draw from it every detail that it is capable of imparting’ F.A. Mahomed 1872 [1] It is now possible to generate the ascending aortic pressure wave from the arterial pressure pulse, recorded noninvasively by applanation tonometry in the radial or carotid artery. This represents a blend of nineteenth century sphygmography with cuff sphygmomanometry, and is made possible by introduction of high fidelity tonometers, by characterization of arterial hydraulic properties in the upper limb and neck, and through application of mathematical engineering techniques in modern computer systems. This review will consider historical development, theoretic background, present status and future potential, as well as comparing this technique with radial and carotid tonometry alone, and with analysis of flow pulse and volume pulse waveforms as determined by Doppler or photoplethysmographic techniques. The arterial pulse is the most fundamental sign in clinical medicine, and has since antiquity been identified with the physician and the art of medicine. Palpation of the pulse forms the crest of the Royal College of Physicians of London, which was established to improve the scientific basis and practice of medicine and in an era when William Harvey, as anatomist to that college, wrote his classic text ‘de Motu Cordis…’[2]. William Bright [3] based his diagnosis of high blood pressure on ‘hardness’ of the pulse, and on the pressure required to extinguish the pulse. A scientific basis only arose after Marey [4], and then Mahomed [1] developed graphic methods to record the arterial pulse. By the beginning of the twentieth century, sphygmography was well established in medical journals and in medical textbooks and had been used to describe heart block and effects of antianginal medication as well as hypertension and other conditions [5–9]. In life insurance examinations sphygmocardiography was widely used for detecting persons with ‘arterial senility’ and increased risk of premature death [10]. Unfortunately sphygmography lapsed with introduction of the cuff sphygmomanometer, which provided numbers for the extremes of the pulse, and a veneer of scientific accuracy. Frederick Akbar Mohamed established the foundation of pulse wave analysis in a short medical lifetime from 1872 to 1884. He described the normal radial pressure waveform and showed the difference between this and the carotid wave [1]. He showed the effect of high blood pressure on the radial waveform, and used the waveform to describe the natural history of essential hypertension, and the difference between this and chronic nephritis [7, 8]. He also described the effects of arterial degeneration with ageing on the arterial pulse [7]. These features were identified and utilized in the life insurance studies of the late nineteenth century [10]. Mahomed's sphygmogram, and the popular Dudgeon sphygmogram which followed, and which was used by Sir James MacKenzie [9] were mechanical devices, awkward to use and prone to artifact. Modern tonometer systems are piezo-electric and are far more accurate, reliable, and easy to use. While originally introduced clinically to measure intraocular pressure, they have been adapted for vascular use by Drzwiecki [11], Millar and others [5, 6]. While Mahomed was the first to recognize the difference between pressure waves in central and peripheral arteries, McDonald [12] was responsible for explaining this phenomenon on the basis of wave reflection, and for introducing transfer functions to characterize properties of vascular beds in the frequency domain, and (with his colleague J.R. Womersley) for establishing the validity of assuming linearity in the arterial tree [13]. The work of McDonald, Womersley, Taylor and others, originally from Harvey's own hospital (St Bartholomew's, London) has led on to the techniques described here for pulse wave analysis. The technique of noninvasive aortic pulse wave analysis, as described here, depends on accurate recording of the radial pressure wave, its calibration against brachial pressure, then generation of the ascending aortic pressure waveform through use of a generalized transfer function in a computerized process. Ascending aortic waveforms are ensemble averaged into a single calibrated wave whose different features can be identified automatically with clinically important measures of pressure and time intervals measured and printed out in an interpretive report (Figure 1). Steps in the process are described below. The Sphygmocardiograph: computerized report on analysis of radial artery and synthesized aortic pressure waves. A series of radial artery pressure waves, recorded over an 8 s period (upper continuous tracing) are used to synthesize a series of ascending aortic pressure waves (lower continuous trace) using a convol
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hemodynamic Patterns of Age-Related Changes in Blood Pressure: The Framingham Heart Study
Franklin, S. S., Gustin, W., Wong, N. D., Larson, M. G., Weber, M. A., Kannel, W. B., & Levy, D. (1997) · Circulation · doi:10.1161/01.cir.96.1.308 · Cited by 2,321
McDonald, D. A. (1963) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196301000-00017 · Cited by 1,565
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Self-citationThe influence of heart rate on augmentation index and central arterial pressure in humans
Wilkinson, I. B., MacCallum, H., Flint, L., Cockcroft, J. R., Newby, D. E., & Webb, D. J. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00263.x · Cited by 1,091
Effects of age and aerobic capacity on arterial stiffness in healthy adults.
Vaitkevicius, P. V., Fleg, J. L., Engel, J. H., O'Connor, F. C., Wright, J. G., Lakatta, L. E., Yin, F. C., & Lakatta, E. G. (1993) · Circulation · doi:10.1161/01.cir.88.4.1456 · Cited by 1,083
Avolio, A. P., Chen, S. G., Wang, R. P., Zhang, C. L., Li, M. F., & O'Rourke, M. F. (1983) · Circulation · doi:10.1161/01.cir.68.1.50 · Cited by 965
Self-citationReproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
Wilkinson, I. B., Fuchs, S. A., Jansen, I. M., Spratt, J. C., Murray, G. D., Cockcroft, J. R., & Webb, D. J. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816121-00033 · Cited by 924
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Self-citationExperimental Subendocardial Ischemia in Dogs with Normal Coronary Arteries
BUCKBERG, G. D., FIXLER, D. E., ARCHIE, J. P., & HOFFMAN, J. I. E. (1972) · Circulation Research · doi:10.1161/01.res.30.1.67 · Cited by 845
Avolio, A. P., Deng, F. Q., Li, W. Q., Luo, Y. F., Huang, Z. D., Xing, L. F., & O'Rourke, M. F. (1985) · Circulation · doi:10.1161/01.cir.71.2.202 · Cited by 839
Self-citationArterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension.
O'Rourke, M. (1990) · Hypertension · doi:10.1161/01.hyp.15.4.339 · Cited by 622
Self-citationTakazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Use of Sildenafil (Viagra) in Patients With Cardiovascular Disease
Cheitlin, M. D., Hutter, A. M., Brindis, R. G., Ganz, P., Kaul, S., Russell, R. O., Zusman, R. M., Forrester, J. S., Douglas, P. S., Faxon, D. P., et al. (1999) · Circulation · doi:10.1161/01.cir.99.1.168 · Cited by 497
Systolic blood pressure, arterial rigidity, and risk of stroke. The Framingham study
Kannel, W. B. (1981) · JAMA · doi:10.1001/jama.245.12.1225 · Cited by 489
Noninvasive Pulse Wave Analysis for the Early Detection of Vascular Disease
Cohn, J. N., Finkelstein, S., McVeigh, G., Morgan, D., LeMay, L., Robinson, J., & Mock, J. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.503 · Cited by 474
Lehmann, E. D. (1998) · Circulation · doi:10.1161/01.cir.98.2.186 · Cited by 353
(1996) · PubMed · Cited by 330
Diastolic failure: Pathophysiology and therapeutic implications
Brutsaert, D. L., Sys, S. U., & Gillebert, T. C. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90850-z · Cited by 326
Gender-Related Differences in the Central Arterial Pressure Waveform
Hayward, C. S., & Kelly, R. P. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00378-1 · Cited by 323
KELLY, R. P., GIBS, H. H., O'ROURKE, M. F., DALEY, J. E., MANG, K., MORGEN, J. J., & AVOLID, A. P. (1990) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a059669 · Cited by 312
Self-citationBorow, K. M., & Newburger, J. W. (1982) · American Heart Journal · doi:10.1016/0002-8703(82)90403-3 · Cited by 310
NITRO-GLYCERINE AS A REMEDY FOR ANGINA PECTORIS.
Murrell, W. (1879) · The Lancet · doi:10.1016/s0140-6736(02)46032-1 · Cited by 289
Westerhof, N., & O??Rourke, M. F. (1995) · Journal of Hypertension · doi:10.1097/00004872-199509000-00002 · Cited by 282
Self-citationLIANG, Y.-L., TEEDE, H., KOTSOPOULOS, D., SHIEL, L., CAMERON, J. D., DART, A. M., & McGRATH, B. P. (1998) · Clinical Science · doi:10.1042/cs0950669 · Cited by 277
Saba, P. S., Roman, M. J., Pini, R., Spitzer, M., Ganau, A., & Devereux, R. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90772-s · Cited by 266
Influence of Sex on Arterial Hemodynamics and Blood Pressure: Role of Body Height
London, G. M., Guerin, A. P., Pannier, B., Marchais, S. J., & Stimpel, M. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.514 · Cited by 258
ROWELL, L. B., BRENGELMANN, G. L., BLACKMON, J. R., BRUGE, R. A., & MURRAY, J. A. (1968) · Circulation · doi:10.1161/01.cir.37.6.954 · Cited by 257
OʼRourke, M. F., & Mancia, G. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917010-00001 · Cited by 257
Self-citationMcDonaldʼs Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Carretta, R. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816040-00020 · Cited by 255
Smulyan, H., Marchais, S. J., Pannier, B., Guerin, A. P., Safar, M. E., & London, G. M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00056-4 · Cited by 242
Arterial tonometry: Review and analysis
Drzewiecki, G. M., Melbin, J., & Noordergraaf, A. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90037-4 · Cited by 235
NITRO-GLYCERINE AS A REMEDY FOR ANGINA PECTORIS.
Murrell, W. (1879) · The Lancet · doi:10.1016/s0140-6736(02)42573-1 · Cited by 220
Fetics, B., Nevo, E., Chen, C.-H., & Kass, D. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764946 · Cited by 211
Effect of glyceryl trinitrate on peripheral arteries alters left ventricular hydraulic load in man
YAGINUMA, T., AVOLIO, A., O'ROURKE, M., NICHOLS, W., MORGAN, J. J., ROY, P., BARON, D., BRANSON, J., & FENELEY, M. (1986) · Cardiovascular Research · doi:10.1093/cvr/20.2.153 · Cited by 183
Self-citationUnderestimation of Vasodilator Effects of Nitroglycerin by Upper Limb Blood Pressure
Takazawa, K., Tanaka, N., Takeda, K., Kurosu, F., & Ibukiyama, C. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.520 · Cited by 170
Cameron, J. D., McGrath, B. P., & Dart, A. M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00411-2 · Cited by 168
Dynamics of left ventricular ejection in obstructive and nonobstructive hypertrophic cardiomyopathy.
Murgo, J. P., Alter, B. R., Dorethy, J. F., Altobelli, S. A., & McGranahan, G. M. (1980) · Journal of Clinical Investigation · doi:10.1172/jci109990 · Cited by 155
Spurious systolic hypertension in youth
O'Rourke, M. F., Vlachopoulos, C., & Graham, R. M. (2000) · Vascular Medicine · doi:10.1177/1358836x0000500303 · Cited by 151
Self-citationSiebenhofer, A., Kemp, C., Sutton, A., & Williams, B. (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000887 · Cited by 149
Different Effects of Fosinopril and Atenolol on Wave Reflections in Hypertensive Patients
Chen, C.-H., Ting, C.-T., Lin, S.-J., Hsu, T.-L., Yin, F. C. P., Siu, C. O., Chou, P., Wang, S.-P., & Chang, M.-S. (1995) · Hypertension · doi:10.1161/01.hyp.25.5.1034 · Cited by 149
O’Rourke, M. F., Kelly, R. P., & Avolio, A. P. (1991) · Cited by 148
Self-citationAugmentation of central arterial pressure in type 1 diabetes.
Brooks, B. A., Molyneaux, L. M., & Yue, D. K. (1999) · Diabetes Care · doi:10.2337/diacare.22.10.1722 · Cited by 147
Westerbacka, J., Wilkinson, I., Cockcroft, J., Utriainen, T., Vehkavaara, S., & Yki-Järvinen, H. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1118 · Cited by 136
O'Rourke, M. F. (1970) · Cardiovascular Research · doi:10.1093/cvr/4.3.291 · Cited by 128
Self-citationUiterwaal, C. S. P. M., Anthony, S., Launer, L. J., Witteman, J. C. M., Trouwborst, A. M. W., Hofman, A., & Grobbee, D. E. (1997) · Hypertension · doi:10.1161/01.hyp.30.2.267 · Cited by 126
Boudoulas, H. (1990) · European Heart Journal · doi:10.1093/eurheartj/11.suppl_i.93 · Cited by 110
The Study of the Pulse, Arterial, Venous and Hepatic and of the Movements of the Heart.
(1902) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1902.02480370056022 · Cited by 103
Pressure wave propagation in a multibranched model of the human upper limb
Karamanoglu, M., Gallagher, D. E., Avolio, A. P., & O'Rourke, M. F. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.4.h1363 · Cited by 103
Self-citationMarcus, R. H., Korcarz, C. E., McCray, G. R., Neumann, A., Murphy, M. F., Borow, K. M., Weinert, L., Bednarz, J., Gretler, D. D., & Spencer, K. T. (1994) · Circulation · doi:10.1161/01.cir.89.6.2688 · Cited by 81
The Etiology of Bright's Disease and the Prealbuminuric Stage
Mahomed, F. A. (1874) · Journal of the Royal Society of Medicine · doi:10.1177/095952877405700118 · Cited by 80
Comparison of Direct and Indirect Arterial Pressure Measurements in Hospitalised Patients**
Breit, S. N., & O'Rourke, M. F. (1974) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1974.tb03222.x · Cited by 69
Self-citationDifferentiation between Systolic and Diastolic Dysfunction
Federmann, M., & Hess, O. M. (1994) · European Heart Journal · doi:10.1093/eurheartj/15.suppl_d.2 · Cited by 68
Megnien, J. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00477-9 · Cited by 65
Takazawa, K., O’Rourke, M. F., Fujita, M., Tanaka, N., Takeda, K., Kurosu, F., & Ibukiyama, C. (1996) · PubMed · Cited by 64
Self-citationWATSON, S., WENZEL, R., DIMATTEO, C., Meier, B., & Lüscher, T. F. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00188-5 · Cited by 60
Combined Effects of Hypertension and Hypercholesterolemia on Radial Artery Function
Giannattasio, C., Mangoni, A. A., Failla, M., Stella, M. L., Carugo, S., Bombelli, M., Sega, R., & Mancia, G. (1997) · Hypertension · doi:10.1161/01.hyp.29.2.583 · Cited by 43
Simkus, G. J., & FITCHETT, D. H. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90843-p · Cited by 43
Teede, H. J., Liang, Y., Shiel, L. M., McNeil, J. J., & McGrath, B. P. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00155-2 · Cited by 41
Ewy, G. A., Rios, J. D., & Marcus, G. M. (1969) · Circulation · doi:10.1161/01.cir.39.5.655 · Cited by 38
Miyashita, H., Ikeda, U., Tsuruya, Y., Sekiguchi, H., Shimada, K., & Yaginuma, T. (1994) · Heart and Vessels · doi:10.1007/bf01744493 · Cited by 38
(1999) · PubMed · Cited by 38
Arterial Haemodynamics and Ventricular-Vascular Interaction in Hypertension
O’Rourke, M. F. (1994) · Blood Pressure · doi:10.3109/08037059409101519 · Cited by 35
Self-citationAccuracy of a New Wrist Cuff Oscillometric Blood Pressure Device
Watson, S., Wenzel, R. R., Matteo, C. D., et al. (1998) · doi:10.7892/boris.115289 · Cited by 31
The factors influencing the prominence of the dicrotic wave
Lewis, T. A. (1906) · The Journal of Physiology · doi:10.1113/jphysiol.1906.sp001165 · Cited by 30
The rhythm of running: can the heart join in?
O’Rourke, M. F., Avolio, A. P., STELLIOU, V., Young, J. M., & Gallagher, D. (1993) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1993.tb04732.x · Cited by 22
Self-citationO’Rourke, M. F., & Nichols, W. W. (2002) · Clinical Cardiology · doi:10.1002/clc.4960250611 · Cited by 21
Self-citation
Cited by
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
Self-citationHighly Stretchable and Sensitive Strain Sensors Using Fragmentized Graphene Foam
Jeong, Y. R., Park, H., Jin, S. W., Hong, S. Y., Lee, S., & Ha, J. S. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201501000 · Cited by 641
A Wireless Textile-Based Sensor System for Self-Powered Personalized Health Care
Meng, K., Zhao, S., Zhou, Y., Wu, Y., Zhang, S., He, Q., Wang, X., Zhou, Z., Fan, W., Tan, X., et al. (2020) · Matter · doi:10.1016/j.matt.2019.12.025 · Cited by 450
Effect of Smoking on Arterial Stiffness and Pulse Pressure Amplification
Mahmud, A., & Feely, J. (2003) · Hypertension · doi:10.1161/01.hyp.0000047464.66901.60 · Cited by 436
Chirinos, J. A., Zambrano, J. P., Chakko, S., Veerani, A., Schob, A., Willens, H. J., Perez, G., & Mendez, A. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000165025.16381.44 · Cited by 364
Metadata
- Authors
- O'Rourke, M. F., Pauca, A., & Jiang, X.
- Venue
- British Journal of Clinical Pharmacology
- Publisher
- Wiley
- Published
- 2001-06
- Volume
- 51
- Issue
- 6
- Pages
- 507-522
- ISSN
- 0306-5251 (ISSN-L)
- 1365-2125
- OpenAlex
- W2095134437
- Cited by
- 640
- References
- 67
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.