Racial Bias in Pulse Oximetry Measurement
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Related work on pulse oximetry, which relies on the same optical principles, has also documented skin-pigmentation-linked measurement errors [14,15]”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Patients with darker skin pigmentation are more likely than patients with lighter skin color to have overestimated SpO2 readings”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“leading to lower hospital admission; higher occult hypoxemia; and delayed or no access to dexamethasone, therapeutic oxygen, and COVID-19 therapies, resulting in increased hospital readmission, organ dysfunction, and mortality [11-18].”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Results from a large study [17] that includes 1333 white patients and 276 black patients indicated that the incidence of hypoxemia can be 3 times higher among patients self-reported as Black vs White because the oxygen saturation readings of black patients tend to be overestimated at a low SpO2 range.”
From Investigating the accuracy of blood oxygen saturation measurements in common consumer smartwatches (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“For example, racial bias can lead to undetected hidden hypoxemia.”
From Investigating the accuracy of blood oxygen saturation measurements in common consumer smartwatches (2023) · cites this paper as [17]
In the citing paper
“As a result, Black patients are three times more likely to suffer from an occult hypoxemia that remains undetected by pulse oximeters compared with white patients.”
From Addressing bias in big data and AI for health care: A call for open science (2021) · cites this paper as [1]
In the citing paper
“Imbalanced samples are a form of bias that the medical community has historically and still currently struggles to address [42].”
From Bias in medical AI: Implications for clinical decision-making (2024) · cites this paper as [42]
In the citing paper
“Bias in clinical parameters such as glomerular filtration rate, pulse oximetry (with undiagnosed hidden hypoxemia for historically underserved patients), 35 differences in ICU severity scoring 36 shape radiology data sets for machine learning through a cascade effect as they affect ordering patterns for medical images.”
From AI pitfalls and what not to do: mitigating bias in AI (2023) · cites this paper as [35]
In the citing paper
“At the same time, people of colour are consistently misclassified by health sensors such as oximeters as they were validated on predominantly white populations [191].”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [191]
In the citing paper
“there is evidence that pulse oximeters also have increased error rates based on skin tone11,12”
From Response To: Investigating sources of inaccuracy in wearable optical heart rate sensors (2021) · cites this paper as [12]
In the citing paper
“Besides, they found overestimations in dark-skinned patients with an increased risk of occult hypoxemia [50].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“An important finding of this study is that the probability of dark-skinned patients with SpO2 reading between 92% and 96% having an arterial oxygen saturation of less than 88% was 3 times higher (11.7%) than light-skinned patients (3.6%) with the same SpO2 measurement.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“They conducted this study in two large cohorts at the University of Michigan Hospital comparing measurements of SpO2 and arterial blood gas of a sample of over 10,000 people with 14–20% of dark-skinned patients in both cohorts.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“More recent studies have also revealed that dark skin pigmentation influences the accuracy and performance of pulse oximeters devices, resulting in overestimations [17,49,50,51,52,53] with increased incidence in the risk for occult hypoxemia (SO2<88% despite normal SpO2>92%) [54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“and other subjective scales were employed in 13 studies (35.14%) [30,42,43,44,45,50,52,56,72,78,80,87,88].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“Specifically, in the first cohort (n = 10,789), 11.4% Black patients had undetected hypoxemia (pulse oximetry > 92% and arterial oxygen saturation < 88%), compared to 3.6% white patients, and in the second cohort (n = 37,308), 17.0% Black patients had undetected hypoxemia, compared to 6.2% white patients.”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [6]
In the citing paper
“A recent study by Sjoding et al. found that when compared to white patients, Black patients had a threefold increased frequency of undetected hypoxemia when using pulse oximeters [6].”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [6]
In the citing paper
“Specifically, in the first cohort (n = 10,789), 11.4% Black patients had undetected hypoxemia (pulse oximetry > 92% and arterial oxygen saturation < 88%), compared to 3.6% white patients, and in the second cohort (n = 37,308), 17.0% Black patients had undetected hypoxemia, compared to 6.2% white patients.”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [6]
In the citing paper
“A racial discrepancy has been established in pulse oximeters, which rely on transmission PPG, a slightly different form of the technology.”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [6]
In the citing paper
“Results showed people described as Black had ‘nearly three times the frequency of occult hypoxemia that was not detected by pulse oximetry’ as those described as White [7].”
From The effects of skin pigmentation on the accuracy of pulse oximetry in measuring oxygen saturation: a systematic review and meta-analysis (2022) · cites this paper as [7]
In the citing paper
“Two recent diagnostic studies provide evidence on clinical implications resulting from the bias in pulse oximetry for blood oxygen saturation levels [7, 57].”
From The effects of skin pigmentation on the accuracy of pulse oximetry in measuring oxygen saturation: a systematic review and meta-analysis (2022) · cites this paper as [7]
In the citing paper
“At least two studies used diagnostic accuracy design and only presented proportions of participants with specific ranges of SpO2 in relation to specific SaO2 values, again rather than SpO2 and SaO2 data [7, 57].”
From The effects of skin pigmentation on the accuracy of pulse oximetry in measuring oxygen saturation: a systematic review and meta-analysis (2022) · cites this paper as [7]
In the citing paper
“In these studies, people described as Black had a higher risk of ‘occult hypoxemia that was not detected by pulse oximetry’ compared with those described as White [7].”
From The effects of skin pigmentation on the accuracy of pulse oximetry in measuring oxygen saturation: a systematic review and meta-analysis (2022) · cites this paper as [7]
In the citing paper
“Racial bias has been observed in the measurement of oxygen saturation level by pulse oximetry devices.”
From Unlocking Tomorrow’s Health Care: Expanding the Clinical Scope of Wearables by Applying Artificial Intelligence (2024) · cites this paper as [48]
In the citing paper
“Because of the greater presence of melanin, Black patients have falsely elevated peripheral oxygen saturation detected via pulse oximetry compared with arterial oxygen saturation measured in arterial blood gas.48”
From Unlocking Tomorrow’s Health Care: Expanding the Clinical Scope of Wearables by Applying Artificial Intelligence (2024) · cites this paper as [48]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pollard, T. J., Johnson, A. E. W., Raffa, J. D., Celi, L. A., Mark, R. G., & Badawi, O. (2018) · Scientific Data · doi:10.1038/sdata.2018.178 · Cited by 1,993
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427
Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and Motion
Louie, A., Feiner, J. R., Bickler, P. E., Rhodes, L., Bernstein, M., & Lucero, J. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002002 · Cited by 106
Research works printed but not linked: 1
- Moran-Thomas A. How a popular medical device encodes racial bias. Boston Review. August 5 2020 (http://bostonreview.net/science-nature-race/amy-moran-thomas-how-popular-medical-device-encodes-racial-bias).
Cited by
Sorted by citations
Items 801–900 of 1,000
The Role of Medical Schools in Propagating Physician Bias
Aysola, J., Surya, S. L., & Jones, D. S. (2021) · New England Journal of Medicine · doi:10.1056/nejmc2106008
Pandemics, Preprints, and Praxis
Schwartz, M. R., & Oppold, P. J. (2021) · Advances in human and social aspects of technology book series · doi:10.4018/978-1-7998-6453-0.ch001
Fokus Beatmung, Sauerstofftherapie und Weaning 2021/2022
Fiedler, M. O., Dietrich, M., Reuß, C. J., Bernhard, M. H., Beynon, C., Hecker, A., Jungk, C., Nußhag, C., Michalski, D., Weigand, M. A., et al. (2023) · Die Anaesthesiologie · doi:10.1007/s00101-023-01250-y
WITHDRAWN: Integrating Sex, Gender, and Intersectional Analysis into Bioengineering
Schiebinger, L. L. (2021) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2021.100347
RetractedLife's a gas: saturation should not be used for prescription of long-term oxygen therapy
Ekström, M. P. (2021) · ERJ Open Research · doi:10.1183/23120541.00495-2021
Use of Wearables and Implantable Devices to Monitor Pulmonary Health in the Outpatient Setting
Glinskii, V. V., Lyn, R., Thomas, C., & Pérez, V. D. J. (2021) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202102-0462rr
Laguillo, A. B. C. (2005) · Anuario de derecho concursal
Elliott, M. (2021) · Nursing · doi:10.1097/01.nurse.0000800116.76189.d8
Gender Bias Seen in Medicare Criteria for Diagnosing Obstructive Sleep Apnea in Women
Hurley, D. (2022) · Neurology Today · doi:10.1097/01.nt.0000822332.72315.c0
#TheSkinnyaboutSkin: how good are we at assessing all skin colours?
Harrison, J. (2022) · British Paramedic Journal · doi:10.29045/14784726.2022.03.6.4.60
Harrison-Smith, B., Arefin, M. S., Dumont, A., & Patil, C. A. (2022) · doi:10.1117/12.2610519
Oxygen: Origin, Physiology, Pathophysiology, and Use in the Critically Ill
Gelissen, H. P. M. M., de Grooth, H., & de Man, A. (2022) · Annual update in intensive care and emergency medicine · doi:10.1007/978-3-030-93433-0_6
A Robust Metric of Heart Rate Signal Quality Using Chest Mounted PhotoplethysmographyPreprint
McLean, M. K., Chandrashekhar, M. V. S., Weaver, R. G., Lane-Cordova, A., Smith, M., Porceng, G., Stone, B., McAninch, J., & Armstrong, B. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4089145
Journal update monthly top five
Chatha, R., Anderson, R., Chatha, H., Cocker, L. M., Connelly, M., Ward, C., & Hirst, R. (2022) · Emergency Medicine Journal · doi:10.1136/emermed-2022-212470
Pediatric pulmonary year in review 2021: Sleep medicine
Okorie, C. U. A., Afolabi‐Brown, O., & Tapia, I. E. (2022) · Pediatric Pulmonology · doi:10.1002/ppul.26047
Sensor technologies for mobile and wearable applications in mobile respiratory management
Wacker, J., Bonnal, B., Braun, F., Chételat, O., Ferrario, D., Lemay, M., Rapin, M., Renevey, P., & Yılmaz, G. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823447-1.00006-3
Delirrad, M., Hasanloei, M. A. V., Zeinali, A., Shirzad, N., & Pashaei, M. R. (2022) · Studies in Medical Sciences · doi:10.52547/umj.32.11.857
Monitoring Strategy for the Operating Room and Intensive Care Unit After Thoracic Injury
Duffy, C. C., Bass, G. A., & Lane-Fall, M. B. (2022) · Springer eBooks · doi:10.1007/978-3-031-06959-8_21
Gonzalez-Ibañez, A. M., Rojas-Salinas, P. A., Frodden, E., Jaureguiberry-Bravo, M., & Jara, M. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4133586
Proof-of-Concept Study for Reflectance Pulse Oximetry Using Optical-Fibre-Based Sensors
Annaheim, S., Braun, F., Bernhard, L., Pfammatter, A., Proença, M., Bonnier, G., Ferrario, D., Lemay, M., & Rossi, R. M. (2022) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2022-1032
Pulse Oximeter in a COVID-19 Pandemic: Challenges for Nonmedical Use
宮坂, 勝., & 東出, 雄. (2022) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/jjmi.92.442
Diversity's Pandemic Distractions.
Kahn, J. (2022) · PubMed
Jain, S., Witt, L. J., & Ferrante, L. E. (2022) · Journal of the American Geriatrics Society · doi:10.1111/jgs.18196
Diagnostic dermatologique sur les peaux fortement pigmentées et/ou dites « noires »
Mahé, A. (2022) · Elsevier eBooks · doi:10.1016/b978-2-294-77570-3.00007-9
Eekhof, J. A., & Claessen, R. J. M. (2022) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-2787-4_7
Chefitz, A. B., Birch, T., Yang, Y., & Hussain, A. (2023) · medRxiv · doi:10.1101/2023.01.19.23284747
Fifteen Patients Who Can Be Helped by Medicare
Johnson, K. G., & Raphaelson, M. (2023) · Neurology Clinical Practice · doi:10.1212/cpj.0000000000200118
Comparison of pulse oximetry measurements between high and low skin pigmentation
Ochoa-Gutierrez, V. J., Guerrero‐Zúñiga, S., Reboud, J., Betancourth, M. P., Harvey, A. R., & Cooper, J. M. (2023) · Design and Quality for Biomedical Technologies · doi:10.1117/12.2651059
Yarnell, C. J., Barrett, K. A., Heath, A., Herridge, M. S., Fowler, R. A., Sung, L., Naimark, D. M. J., & TOMLINSON, G. A. (2023) · medRxiv · doi:10.1101/2023.03.16.23286754
(2023) · Oxford University Press eBooks · doi:10.1093/med/9780197556269.002.0014
Artificial Autonomy or Relational Intelligence
Ho, A. (2023) · Oxford University Press eBooks · doi:10.1093/med/9780197556269.003.0002
Ho, A. (2023) · Oxford University Press eBooks · doi:10.1093/med/9780197556269.003.0004
(2023) · Oxford University Press eBooks · doi:10.1093/med/9780197556269.002.0003
(2023) · Oxford University Press eBooks · doi:10.1093/med/9780197556269.002.0005
(2023) · Oxford University Press eBooks · doi:10.1093/med/9780197556269.002.0007
From One-Way Mirror to Two-Way Street
Ho, A. (2023) · Oxford University Press eBooks · doi:10.1093/med/9780197556269.003.0006
Independent Living With(out) Privacy
Ho, A. (2023) · Oxford University Press eBooks · doi:10.1093/med/9780197556269.003.0003
Jolobe, O. M. P. (2023) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2023.04.026
Hwang, C., Kim, Y., Hyun, J. K., Kim, J., Lee, S., Kim, C., Rho, S., Nam, J., & Kim, E. Y. (2023) · Preprints.org · doi:10.20944/preprints202304.0996.v1
Targeted Oxygen Therapy in Adult Intensive Care Unit Patients
Klitgaard, T. (2022) · doi:10.54337/aau473635979
Larsen, R., & Mathes, A. (2023) · Springer eBooks · doi:10.1007/978-3-662-64536-9_20
Optical characterization of highly turbid samples in the visible and near infrared spectra
da Cruz, L. B. (2023) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.59.2023.tde-27062023-140611
Eekhof, J. A., & Claessen, R. J. M. (2023) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-2931-1_7
Towards Development of Specular Reflection Vascular Imaging
Burton, T., Saiko, G., & Douplik, A. (2023) · doi:10.32920/24092121.v1
Fogarty, A., Crooks, C. J., Adejumo, I., Binegdie, A. B., & Shaw, D. E. (2023) · Journal of the Pan African Thoracic Society · doi:10.25259/jpats_22_2023
Anti-Racist Approach to Pulse Oximetry
Lapum, J. L., Prendergast, N., & Istanboulian, L. (2023) · Nurse Educator · doi:10.1097/nne.0000000000001542
Communication of Uncertainty in AI Regulations
Phutane, A. S. (2023) · Community Change · doi:10.21061/cc.v5i1.a.50
Life Threatening Hypoxemia Associated with COVID-19 (Review)
Ahmed, D. M., & Hashim, S. S. (2023) · Current Research in Microbiology and Infection · doi:10.31559/crmi2023.3.1.1
Development and Preclinical Evaluation of a CPAP-Compatible EtCO2 SamplerPreprint
Sethi, S., Hobbs, G. W., Hubbard, D., Donnelly, K., Grover, J., & Rizvi, I. (2023) · medRxiv · doi:10.1101/2023.10.24.23297493
Rohatgi, N. (2023) · JMIR Perioperative Medicine · doi:10.2196/54344
Fisioterapia na Saúde Coletiva: novas perspectivas
Leite, D. S. (2023) · Editora Científica Digital eBooks · doi:10.37885/978-65-5360-493-3
Yang, B. E., & Moss, J. (2023) · CHEST Journal · doi:10.1016/j.chest.2023.08.017
Pulse Oximeters, why a multi-wavelength approach could be used to detect other biomarkers?
Ochoa-Gutierrez, V. J., Guerrero‐Zúñiga, S., Reboud, J., Harvey, A. R., & Cooper, J. M. (2023) · Frontiers in Optics · doi:10.1364/fio.2023.jm4a.65
Scaling of Algorithmic Bias in Pulse Oximetry with Signal-to-Noise Ratio
Cao, J., Mehta, N. A., Wu, J., Wood, S., Kainerstorfer, J. M., & Grover, P. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10341034
Racial Deviations in Smartphone and Wearable Sensor Measurements of Health BiometricsPreprint
Lam, E., Marais, P., & Leung, H. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4663485
ChromaSense-Empowering Health, Empowering You
Durbha, R., & Koomson, V. J. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388804
Wickerson, G. (2024) · ASEE Annual Conference & Exposition · doi:10.18260/1-2--43255
Mettler, S. K., Charoenngam, N., Jaroenlapnopparat, A., Tern, C., Xanthavanij, N., Economidou, S. C., Strand, M. J., Hobbs, B. D., Moll, M. R., & Cho, M. H. (2024) · medRxiv · doi:10.1101/2024.03.28.24305036
La COVID-19 et le bip du saturomètre de pouls
Ayonrinde, O. (2024) · Canadian Medical Association Journal · doi:10.1503/cmaj.230221-f
Transcutaneous Versus Blood Gas Measurement of CO2 in Neonates: Variation by Method and Racial GroupPreprint
Reichert, L. K., Scott, S. R., Dugan, T., Setzen, S. A., Feustel, P. J., & Pezzano, C. (2024) · Research Square · doi:10.21203/rs.3.rs-4385496/v1
Investigation of skin pigmentation influence on the diffuse reflectance signal and oxygen saturation
Komolibus, K., Jayet, B., Stetson, P., & Andersson‐Engels, S. (2024) · Optics in the Life Sciences · doi:10.1364/translational.2024.tm1b.3
Lovell, N., & Bajwah, S. (2024) · Oxford University Press eBooks · doi:10.1093/med/9780192864741.003.0006
To give or not give corticosteroids; that is the question
Ciarkowski, C. E., & Vaughn, V. M. (2024) · Journal of Hospital Medicine · doi:10.1002/jhm.13444
Introduction to sleep telemedicine
Won, C. H. J., & Kryger, M. H. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-87041-2.00010-5
Algorithmic Bias in Lung Protective Tidal Volume FormulasPreprint
Sarma, A. A., Sullivan, K. M., Baugh, A. D., Bhakta, N. R., & Calfee, C. S. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4898478
Oxygenation targets in critically ill children: the Oxy-PICU trial
Chen, A., Chen, X., Huang, S., & Zheng, X. (2024) · The Lancet · doi:10.1016/s0140-6736(24)01560-5
Monitoring Patients on Long-Term Noninvasive Ventilation
Ackrivo, J. (2024) · Respiratory medicine · doi:10.1007/978-3-031-65335-3_6
Impact of epidermal melanin on peripheral pulse oximetry measurementsPreprint
Rice, J. C., Dixon, J., Renfrew, E., Nemeth, D. V., Finkelstein, A., Gernhofer, Y., Hinckley, S., Chaparro, R., Samson, T., Pizano, C., et al. (2024) · medRxiv · doi:10.1101/2024.09.17.24313822
Acute Respiratory Distress Syndrome: Updates for Critical Care Transport
Roginski, M. A., Atchinson, P. R., Esteves, A. M., Lentz, S. A., Fjeld, K. J., Markwood, J. M., Lauria, M., & Bernardoni, B. (2024) · Air Medical Journal · doi:10.1016/j.amj.2024.09.005
Fair, F. J., Furness, A., Higginbottom, G. A., Oddie, S., & Soltani, H. (2024) · PLoS ONE · doi:10.1371/journal.pone.0311977
Wie die Generation Z die Gesundheitsversorgung von BIPoC verändert
Rick, M. M. (2024) · Springer eBooks · doi:10.1007/978-3-662-69213-4_22
Wojtkiewicz, A. M., Piekarska, M. M., Mamcarz, A., & Śliż, D. (2024) · Folia Cardiologica · doi:10.5603/fc.98299
Weissbrod, R., & Blake, C. (2024) · Medical Devices Evidence and Research · doi:10.2147/mder.s492561
Pulse Oximetry: A Vital Tool with Important Functional Limitations for Patients with Dark Skin Color
Harris, D. E. (2024) · Universal Library of Clinical Nursing · doi:10.70315/uloap.ulcnu.2024.0101005
Assessing Bias in Self-supervised and Supervised Models for Temporal Data
Liatsikou, M., Yfantidou, S., & Vakali, A. I. (2024) · Hellenic Conference on Artificial Intelligence · doi:10.1145/3688671.3688753 · Cited by 1
Oxygen Targets for Mechanically Ventilated Adults with Sepsis: Secondary Analysis of the PILOT Trial
Shapiro, J. C., Casey, J. D., Qian, E. T., Seitz, K. P., Wang, L., Lloyd, B. D., Stollings, J. L., Freundlich, R. E., Self, W. H., Rice, T. W., et al. (2025) · Journal of Intensive Care Medicine · doi:10.1177/08850666241299378
An Overview of the Afferent Limb
Prytherch, D. R., Subbe, C. P., & Psirides, A. J. (2024) · Springer eBooks · doi:10.1007/978-3-031-67951-3_7
कतरम बदधमत क नगरक अधकर पर परभव
-, A. K., & -, P. P. P. (2025) · International Journal For Multidisciplinary Research · doi:10.36948/ijfmr.2025.v07i01.35139
Robertson, M. L., Bouhassira, D. C. G., Bernstein, T., & Iwashyna, T. J. (2025) · Journal of the American Geriatrics Society · doi:10.1111/jgs.19376
Self-citationChefitz, A. B., Singh, R., Birch, T., Yang, Y., Hussain, A., & Chefitz, G. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3010006
Carter, A., Singer, M., & Webb, A. R. (2025) · Oxford University Press eBooks · doi:10.1093/med/9780199688876.003.0009
The skin deep truth: Why pulse oximeters may be misleading
Gupta, S. (2025) · The Journal of the Royal College of Physicians of Edinburgh · doi:10.1177/14782715251327240
Preliminary investigation of partial optical path-lengths in pulse oximetry
Blaney, G. P., Frias, J., Tavakoli, F., Sassaroli, A., & Fantini, S. (2025) · Optical Tomography and Spectroscopy of Tissue · doi:10.1117/12.3042282
Hemkumar, A., Hermann, J., Wilson, B., & Rajbhandary, P. L. (2025) · Design and Quality for Biomedical Technologies · doi:10.1117/12.3042294
Boonya-ananta, T., Rodriguez, A. J., Pei, J., Ajmal, A., Sanchez, A. N., Vasallo, A., Suastegi, C., Paz, N., & Ramella‐Roman, J. C. (2025) · Design and Quality for Biomedical Technologies · doi:10.1117/12.3045961
The Saga of Equitable Oxygen Saturation Measurement Continues: The Role of Arterial Blood Gases
Chesley, C. F., & Anesi, G. L. (2025) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202502-0339ed
Jayaram, K., & Peddu, A. (2025) · American Anthropologist · doi:10.1111/aman.28060
Human Factors and Behavioral Sensing in AI Applications
Constantinides, M., Spathis, D., & Yfantidou, S. (2025) · Human-computer interaction series · doi:10.1007/978-3-031-61375-3_10
Acute Exacerbations of Chronic Obstructive Pulmonary Disease
McNamara, L. C., Reichheld, A. M., & Petri, C. R. (2025) · Springer eBooks · doi:10.1007/978-3-031-77335-8_6
Racial Differences in Temporal Thermometry and Association with Delayed Sepsis Bundle CarePreprint
de Matos, J. C. R. G., Alwakeel, M. I., Hao, S., Martins, I. S., Cardoso, J. S., Gichoya, J. W., Celi, L. A., Lane, A., Krishnamoorthy, V., Bhavani, S. V., et al. (2025) · medRxiv · doi:10.1101/2025.03.31.25324893
Art, K. (2025) · IGI Global eBooks · doi:10.4018/979-8-3693-3683-0.ch005
AI-Driven and Automated Continuous Oxygen Saturation Monitoring and LTOT: A Systematic ReviewPreprint
Niraula, P., Kadariya, S., Poudel, B., & Kadariya, S. (2025) · medRxiv · doi:10.1101/2025.04.20.25326131
Pirzadeh, M., & Mendez, M. P. (2025) · doi:10.1093/med/9780197754153.003.0020
Bose, S., Binda, D. D., Ramachandran, S. K., & Nafiu, O. O. (2025) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000007522
Transport of the Neurocritical Care Patient
Srinivasan, V., & Dangayach, N. S. (2025) · Current Treatment Options in Neurology · doi:10.1007/s11940-025-00843-9
Reducing Diagnostic Bias in Oxygenation Assessments
Terrell, J., Smith, K., Philippe, A. E., & Booker, S. Q. (2025) · AJN American Journal of Nursing · doi:10.1097/ajn.0000000000000086
Multimodal Neuromonitoring and Artificial Intelligence
Hemphill, J. C., & Dhar, R. (2025) · Oxford University Press eBooks · doi:10.1093/med/9780198864714.003.0011
Structural inequalities and chronic disease health outcomes: The role of research and evidence
Weerahandi, H. M., Siddiqui, S. B., & Rollin, F. G. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-23750-8.00028-x
Metadata
- Authors
- Sjoding, M. W., Dickson, R. P., Iwashyna, T. J., Gay, S. E., & Valley, T. S.
- Affiliations
- University of Michigan (US)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2020-12-17
- Volume
- 383
- Issue
- 25
- Pages
- 2477-2478
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- PMC
- PMC7808260
- OpenAlex
- W3111737151
- Cited by
- 1,114
- References
- 3
- Citations by year
- 2026: 191 · 2025: 182 · 2024: 193 · 2023: 227 · 2022: 209 · 2021: 109 · 2020: 1
- FWCI
- 42.90
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Health Services Research and Development (IIR 17-045)
- National Heart, Lung, and Blood Institute (K01 HL136687, K12 HL138039, K23 HL140165, R01 HL144599)
- U.S. National Library of Medicine (R01 LM013325)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Computer Science › Artificial Intelligence › Ethics and Social Impacts of AI
- Social Sciences › Anthropology › Race, Genetics, and Society
- Keywords
- pulse oximetry, racial bias, skin pigmentation, oxygen saturation measurement, measurement error, racial disparities in health care
- MeSH terms
- Adult, Hypoxia, Black or African American, Female, Humans, Male, Oximetry, Oxygen, White People, Organ Dysfunction Scores, Racism
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review