The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Racial Bias in Pulse Oximetry Measurement
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Related work on pulse oximetry, which relies on the same optical principles, has also documented skin-pigmentation-linked measurement errors [14,15]”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Patients with darker skin pigmentation are more likely than patients with lighter skin color to have overestimated SpO2 readings”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“leading to lower hospital admission; higher occult hypoxemia; and delayed or no access to dexamethasone, therapeutic oxygen, and COVID-19 therapies, resulting in increased hospital readmission, organ dysfunction, and mortality [11-18].”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Results from a large study [17] that includes 1333 white patients and 276 black patients indicated that the incidence of hypoxemia can be 3 times higher among patients self-reported as Black vs White because the oxygen saturation readings of black patients tend to be overestimated at a low SpO2 range.”
From Investigating the accuracy of blood oxygen saturation measurements in common consumer smartwatches (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“For example, racial bias can lead to undetected hidden hypoxemia.”
From Investigating the accuracy of blood oxygen saturation measurements in common consumer smartwatches (2023) · cites this paper as [17]
In the citing paper
“As a result, Black patients are three times more likely to suffer from an occult hypoxemia that remains undetected by pulse oximeters compared with white patients.”
From Addressing bias in big data and AI for health care: A call for open science (2021) · cites this paper as [1]
In the citing paper
“Imbalanced samples are a form of bias that the medical community has historically and still currently struggles to address [42].”
From Bias in medical AI: Implications for clinical decision-making (2024) · cites this paper as [42]
In the citing paper
“Bias in clinical parameters such as glomerular filtration rate, pulse oximetry (with undiagnosed hidden hypoxemia for historically underserved patients), 35 differences in ICU severity scoring 36 shape radiology data sets for machine learning through a cascade effect as they affect ordering patterns for medical images.”
From AI pitfalls and what not to do: mitigating bias in AI (2023) · cites this paper as [35]
In the citing paper
“At the same time, people of colour are consistently misclassified by health sensors such as oximeters as they were validated on predominantly white populations [191].”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [191]
In the citing paper
“there is evidence that pulse oximeters also have increased error rates based on skin tone11,12”
From Response To: Investigating sources of inaccuracy in wearable optical heart rate sensors (2021) · cites this paper as [12]
In the citing paper
“Besides, they found overestimations in dark-skinned patients with an increased risk of occult hypoxemia [50].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“An important finding of this study is that the probability of dark-skinned patients with SpO2 reading between 92% and 96% having an arterial oxygen saturation of less than 88% was 3 times higher (11.7%) than light-skinned patients (3.6%) with the same SpO2 measurement.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“They conducted this study in two large cohorts at the University of Michigan Hospital comparing measurements of SpO2 and arterial blood gas of a sample of over 10,000 people with 14–20% of dark-skinned patients in both cohorts.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“More recent studies have also revealed that dark skin pigmentation influences the accuracy and performance of pulse oximeters devices, resulting in overestimations [17,49,50,51,52,53] with increased incidence in the risk for occult hypoxemia (SO2<88% despite normal SpO2>92%) [54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“and other subjective scales were employed in 13 studies (35.14%) [30,42,43,44,45,50,52,56,72,78,80,87,88].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [50]
In the citing paper
“Specifically, in the first cohort (n = 10,789), 11.4% Black patients had undetected hypoxemia (pulse oximetry > 92% and arterial oxygen saturation < 88%), compared to 3.6% white patients, and in the second cohort (n = 37,308), 17.0% Black patients had undetected hypoxemia, compared to 6.2% white patients.”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [6]
In the citing paper
“A recent study by Sjoding et al. found that when compared to white patients, Black patients had a threefold increased frequency of undetected hypoxemia when using pulse oximeters [6].”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [6]
In the citing paper
“Specifically, in the first cohort (n = 10,789), 11.4% Black patients had undetected hypoxemia (pulse oximetry > 92% and arterial oxygen saturation < 88%), compared to 3.6% white patients, and in the second cohort (n = 37,308), 17.0% Black patients had undetected hypoxemia, compared to 6.2% white patients.”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [6]
In the citing paper
“A racial discrepancy has been established in pulse oximeters, which rely on transmission PPG, a slightly different form of the technology.”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [6]
In the citing paper
“Results showed people described as Black had ‘nearly three times the frequency of occult hypoxemia that was not detected by pulse oximetry’ as those described as White [7].”
From The effects of skin pigmentation on the accuracy of pulse oximetry in measuring oxygen saturation: a systematic review and meta-analysis (2022) · cites this paper as [7]
In the citing paper
“Two recent diagnostic studies provide evidence on clinical implications resulting from the bias in pulse oximetry for blood oxygen saturation levels [7, 57].”
From The effects of skin pigmentation on the accuracy of pulse oximetry in measuring oxygen saturation: a systematic review and meta-analysis (2022) · cites this paper as [7]
In the citing paper
“At least two studies used diagnostic accuracy design and only presented proportions of participants with specific ranges of SpO2 in relation to specific SaO2 values, again rather than SpO2 and SaO2 data [7, 57].”
From The effects of skin pigmentation on the accuracy of pulse oximetry in measuring oxygen saturation: a systematic review and meta-analysis (2022) · cites this paper as [7]
In the citing paper
“In these studies, people described as Black had a higher risk of ‘occult hypoxemia that was not detected by pulse oximetry’ compared with those described as White [7].”
From The effects of skin pigmentation on the accuracy of pulse oximetry in measuring oxygen saturation: a systematic review and meta-analysis (2022) · cites this paper as [7]
In the citing paper
“Racial bias has been observed in the measurement of oxygen saturation level by pulse oximetry devices.”
From Unlocking Tomorrow’s Health Care: Expanding the Clinical Scope of Wearables by Applying Artificial Intelligence (2024) · cites this paper as [48]
In the citing paper
“Because of the greater presence of melanin, Black patients have falsely elevated peripheral oxygen saturation detected via pulse oximetry compared with arterial oxygen saturation measured in arterial blood gas.48”
From Unlocking Tomorrow’s Health Care: Expanding the Clinical Scope of Wearables by Applying Artificial Intelligence (2024) · cites this paper as [48]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pollard, T. J., Johnson, A. E. W., Raffa, J. D., Celi, L. A., Mark, R. G., & Badawi, O. (2018) · Scientific Data · doi:10.1038/sdata.2018.178 · Cited by 1,993
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427
Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and Motion
Louie, A., Feiner, J. R., Bickler, P. E., Rhodes, L., Bernstein, M., & Lucero, J. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002002 · Cited by 106
Flagged first, then by citations
Research works printed but not linked: 1
- Moran-Thomas A. How a popular medical device encodes racial bias. Boston Review. August 5 2020 (http://bostonreview.net/science-nature-race/amy-moran-thomas-how-popular-medical-device-encodes-racial-bias).
Cited by
Sorted by citations
Items 201–300 of 1,000
Benedetti, D., Olcese, U., Bruno, S., Barsotti, M., Maestri, M., Bonanni, E., Siciliano, G., & Faraguna, U. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s352335 · Cited by 23
Accuracy of the Apple Watch Oxygen Saturation Measurement in Adults: A Systematic Review
Windisch, P. Y., Schröder, C., Forster, R. E., Čihorić, N., & Zwahlen, D. R. (2023) · Cureus · doi:10.7759/cureus.35355 · Cited by 23
Participant flow diagrams for health equity in AI
Ellen, J., de Matos, J. C. R. G., Viola, M., Gallifant, J., Quion, J. M., Celi, L. A., & Hussein, N. S. A. (2024) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2024.104631 · Cited by 22
Richards, D. M., Tweardy, M. J., Steinhubl, S. R., Chestek, D. W., Hoek, T. L. V., Larimer, K. A., & Wegerich, S. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00527-z · Cited by 23
Non‐invasive hemoglobin estimation for preoperative anemia screening
Hornedo, K., Jacob, A. K., Burt, J. M., Higgins, A. A., Engel, E. M., Hanson, A. C., Belch, L. M., Kor, D. J., & Warner, M. A. (2023) · Transfusion · doi:10.1111/trf.17237 · Cited by 22
Skin color influences transcutaneous bilirubin measurements: a systematic in vitro evaluation
Dam-Vervloet, A. J., Morsink, C. F., Krommendijk, M. E., Nijholt, I. M., Straaten, H. L. M. V., Poot, L., & Bosschaart, N. (2024) · Pediatric Research · doi:10.1038/s41390-024-03081-y · Cited by 22
Critical care trainees call for pulse oximetry reform
Hidalgo, D. C., Olusanya, O., & Harlan, E. (2021) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(21)00102-8 · Cited by 21
Farmer, M. J. S., Callahan, C. D., Hughes, A. M., Riska, K. L., & Hill, N. S. (2024) · CHEST Journal · doi:10.1016/j.chest.2024.02.040 · Cited by 21
Gueye‐Ndiaye, S., & Redline, S. S. (2024) · Annual Review of Medicine · doi:10.1146/annurev-med-070323-103130 · Cited by 21
Yarnell, C. J., Angriman, F., Ferreyro, B. L., Liu, K., de Grooth, H., Burry, L. D., Munshi, L., Mehta, S., Celi, L. A., Elbers, P., et al. (2023) · Critical Care · doi:10.1186/s13054-023-04307-x · Cited by 22
Hess, M. W. (2023) · Respiratory Care · doi:10.4187/respcare.10876 · Cited by 21
A scoping review exploring the confidence of healthcare professionals in assessing all skin tones
Harrison, J. (2023) · British Paramedic Journal · doi:10.29045/14784726.2023.9.8.2.18 · Cited by 21
Parr, N. J., Beech, E. H., Young, S., & Valley, T. S. (2024) · Journal of General Internal Medicine · doi:10.1007/s11606-024-08852-1 · Cited by 22
Self-citationIntroduction: medicine’s shadowside: revisiting clinical iatrogenesis
Varley, E., & Varma, S. (2021) · Anthropology and Medicine · doi:10.1080/13648470.2021.1937514 · Cited by 21
Miller, I., Lamer, S., Brougham‐Cook, A., Jensen, K., & Golecki, H. M. (2022) · Biomedical Engineering Education · doi:10.1007/s43683-021-00060-1 · Cited by 21
Albert, K., & Delano, M. K. (2022) · Patterns · doi:10.1016/j.patter.2022.100534 · Cited by 25
Oxygen saturation targets for children with respiratory distress: a systematic review
Louman, S., van Stralen, K. J., Pijnenburg, M. W. H., Koppelman, G. H., & Boehmer, A. L. M. (2023) · ERJ Open Research · doi:10.1183/23120541.00256-2023 · Cited by 20
Inclusive and Accurate Clinical Diagnostics Using Intelligent Computation and Smartphone Imaging
Chen, J., Zhao, D., Shi, H. C., Duan, Q., Jajesniak, P., Li, Y., Shen, W., Zhang, J., Reboud, J., Cooper, J. M., et al. (2024) · ACS Sensors · doi:10.1021/acssensors.4c01588 · Cited by 20
Lederer, V., Messing, K., & Sultan‐Taïeb, H. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20010019 · Cited by 22
Sheikh, M., Ahmad, H., Ibrahim, R., Nisar, M. I., & Jehan, F. (2023) · Pneumonia · doi:10.1186/s41479-023-00108-6 · Cited by 20
Savorgnan, F., Hassan, A. M., Borges, N., & Acosta, S. I. (2023) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003208 · Cited by 20
Holder, T. M., Hooper, F. S. W., Yates, D., Tse, Z. T. H., Patil, S. B., Moussa, A., Batten, L., Radhakrishnan, V., Allison, M., Hewitt, C. E., et al. (2023) · Clinical Medicine · doi:10.7861/clinmed.2022-0252 · Cited by 20
ARTIFICIAL INTELLIGENCE (AI) BIAS IMPACTS: CLASSIFICATION FRAMEWORK FOR EFFECTIVE MITIGATION
(2023) · Issues in Information Systems · doi:10.48009/4_iis_2023_128 · Cited by 21
Tandon, A. A., Silva, J. N. A., Bhatt, A. B., Drummond, C. K., Hill, A. C., Paluch, A. E., Waits, S., Zablah, J. E., & Harris, K. C. (2024) · Circulation · doi:10.1161/cir.0000000000001225 · Cited by 20
Glucocorticoid therapy for acute respiratory distress syndrome: Current concepts
Zhao, Y., Yao, Z., Xu, S., Yao, L., & Yu, Z. (2024) · Journal of Intensive Medicine · doi:10.1016/j.jointm.2024.02.002 · Cited by 20
Patterns of Knowing and Being in the COVIDicene
Brown, B. B., Dillard‐Wright, J., Hopkins‐Walsh, J., Littzen, C. O. R., & Vo, T. (2021) · Advances in Nursing Science · doi:10.1097/ans.0000000000000387 · Cited by 20
Insights into Artificial Intelligence Bias: Implications for Agriculture
Mayuravaani, M., Ramanan, A., Perera, M., Senanayake, D., & Vidanaarachchi, R. (2024) · Digital Society · doi:10.1007/s44206-024-00142-x · Cited by 19
Pulse Oximetry and Skin Pigmentation—New Guidance From the FDA
Lipnick, M. S., Ehie, O. A., Igaga, E. N., & Bicker, P. (2025) · JAMA · doi:10.1001/jama.2025.1959 · Cited by 19
Fiske, A., Blacker, S., Geneviève, L. D., Willem, T., Fritzsche, M.-C., Buyx, A., Celi, L. A., & McLennan, S. (2025) · The Lancet Digital Health · doi:10.1016/j.landig.2025.01.003 · Cited by 21
Algorithmic fairness in pandemic forecasting: lessons from COVID-19
Tsai, T. C., Arık, S. Ö., Jacobson, B. H., Yoon, J., Yoder, N. C., Sava, D., Mitchell, M., Graham, G. N., & Pfister, T. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00602-z · Cited by 21
High risk and low prevalence diseases: Acute chest syndrome in sickle cell disease
Koehl, J. L., Koyfman, A., Hayes, B. D., & Long, B. (2022) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2022.06.018 · Cited by 19
Social determinants of recovery
Jain, S., Hauschildt, K. E., & Scheunemann, L. P. (2022) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000982 · Cited by 19
Nathan, S. D., Fernandes, P., Psotka, M. A., Vitulo, P., Piccari, L., Antoniou, K., Nikkho, S. M., & Stockbridge, N. (2022) · Pulmonary Circulation · doi:10.1002/pul2.12178 · Cited by 19
The Problem With Race-Based Medicine
Roberts, D. E. (2023) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000002251 · Cited by 19
Consumer Wearable Sleep Trackers
Chiang, A. A.-P., & Khosla, S. (2023) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2023.05.005 · Cited by 19
The burden of sleep disordered breathing in children with sickle cell disease
Liguoro, I., Arigliani, M., Tan, H., & Gupta, A. K. (2021) · Pediatric Pulmonology · doi:10.1002/ppul.25632 · Cited by 19
Rai, B., Malmberg, R., Srinivasan, V., Ganesh, K. M., Kambhampati, N. S. V., Andar, A. U., Rao, G., Sanjeevi, C. B., Venkatesan, K., & Ramamurthy, S. S. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01665 · Cited by 19
Crooks, C. J., West, J., Morling, J. R., Simmonds, M., Juurlink, I., Briggs, S., Cruickshank, S., Hammond-Pears, S., Shaw, D., Card, T. R., et al. (2022) · QJM · doi:10.1093/qjmed/hcac218 · Cited by 19
Phan, T., Rowland, R. A., Ponticorvo, A., Le, B. C., Sharif, S. A., Kennedy, G. T., Wilson, R. H., & Durkin, A. J. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.3.036002 · Cited by 18
Douville, N. J., Smolkin, M. E., Naik, B. I., Mathis, M. R., Colquhoun, D. A., Kheterpal, S., Collins, S. R., Martin, L. W., Popescu, W. M., Pace, N. L., et al. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.08.005 · Cited by 18
Origins of Racial and Ethnic Bias in Pulmonary Technologies
Sjoding, M. W., Ansari, S., & Valley, T. S. (2022) · Annual Review of Medicine · doi:10.1146/annurev-med-043021-024004 · Cited by 18
Self-citationPulse oximetry values from 33,080 participants in the Apple Heart & Movement Study
Shapiro, I., Stein, J., MacRae, C. A., & OReilly, M. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00851-6 · Cited by 18
Open datasets in perioperative medicine: a narrative review
Lim, L., & Lee, H. (2023) · Anesthesia and Pain Medicine · doi:10.17085/apm.23076 · Cited by 18
The role of payment and financing in achieving health equity
Eschliman, B. H., Pham, H. H., Navathe, A. S., Dale, K. M., & Harris, J. (2023) · Health Services Research · doi:10.1111/1475-6773.14219 · Cited by 18
Association Between Patient Race and Ethnicity and Use of Invasive Ventilation in the United States
Abdelmalek, F. M., Angriman, F., Moore, J. E., Liu, K., Burry, L. D., Seyyed-Kalantari, L., Mehta, S., Gichoya, J. W., Celi, L. A., TOMLINSON, G. A., et al. (2023) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202305-485oc · Cited by 18
Remote Hub Lab – RHL: Broadly Accessible Technologies for Education and Telehealth
Hussein, R., Chap, B., Inoñan, M., Guo, M., Monroy, F. L., Maloney, R. C., Ferreria, S. A., & Kalisi, S. J. (2023) · Lecture notes in networks and systems · doi:10.1007/978-3-031-42467-0_7 · Cited by 18
Determining factors of pulse oximetry accuracy: a literature review
Valladares, D. L., Mateu, L. A. B., Cortés-Carmona, N., Fuentes-Lizana, G., Cabanas, A. M., Latorre-Progulakis, K., Fuentes‐Guajardo, M., & Martín-Escudero, P. (2024) · Revista Clínica Española (English Edition) · doi:10.1016/j.rceng.2024.04.005 · Cited by 20
Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study
Hao, S., Dempsey, K., de Matos, J. C. R. G., Cox, C. E., Rotemberg, V. M., Gichoya, J. W., Kibbe, W. A., Hong, C., & Wong, A.-K. I. (2024) · Critical Care Explorations · doi:10.1097/cce.0000000000001133 · Cited by 18
ROY, S. K., Wu, J., Cao, J., Disu, J. D. K., Bharadwaj, S., Meinert-Spyker, E., Grover, P., Kainerstorfer, J. M., & Wood, S. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s3.s33310 · Cited by 17
Ten simple rules in biomedical engineering to improve healthcare equity
Lanier, O. L., Green, M. D., Barabino, G. A., & Cosgriff‐Hernandez, E. (2022) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1010525 · Cited by 17
Oxygen Targets in Neonatal Pulmonary Hypertension
Lakshminrusimha, S., & Abman, S. H. (2023) · Clinics in Perinatology · doi:10.1016/j.clp.2023.12.003 · Cited by 17
Al-Halawani, R., Qassem, M., & Kyriacou, P. A. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s3.s33305 · Cited by 17
Pini, N., Fifer, W. P., Oh, J., Nebeker, C., Croff, J. M., & Smith, B. A. (2024) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2024.101446 · Cited by 20
Cho, H. J., Smith, D. M., Hart, A. L., Prasad, R., Sata, S. S., Clarke, K., Arole, O., Beurlein, J., George, M. C., Moore, C., et al. (2022) · Journal of General Internal Medicine · doi:10.1007/s11606-021-07269-4 · Cited by 17
Playing hide and seek with structural racism
Gopal, D. P., & Rao, M. (2021) · BMJ · doi:10.1136/bmj.n988 · Cited by 17
Racial bias in pulse oximetry: More statistical detail may help tackle the problem
Philip, K. E. J., Tidswell, R., & McFadyen, C. (2021) · BMJ · doi:10.1136/bmj.n298 · Cited by 16
Sarma, A. A., Sullivan, K. M., Baugh, A. D., Bhakta, N. R., & Calfee, C. S. (2025) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(25)00126-2 · Cited by 16
Monte Carlo based simulations of racial bias in pulse oximetry
Arefin, M. S., Dumont, A. P., & Patil, C. A. (2022) · doi:10.1117/12.2610483 · Cited by 16
First- and Second-Level Bias in Automated Decision-making
Franke, U. (2022) · Philosophy & Technology · doi:10.1007/s13347-022-00500-y · Cited by 16
Ethnic disparities in publicly-available pulse oximetry databases
Sinaki, F. Y., Ward, R. K., Abbott, D., Allen, J., Fletcher, R., Menon, C., & Elgendi, M. (2022) · Communications Medicine · doi:10.1038/s43856-022-00121-8 · Cited by 18
Rea, M. S., & Bierman, A. (2023) · British Journal of Anaesthesia · doi:10.1016/j.bja.2023.04.018 · Cited by 16
Pulse oximetry to detect paediatric hypoxaemia—the fifth vital sign
Zar, H. J., & McCollum, E. D. (2023) · The Lancet Global Health · doi:10.1016/s2214-109x(23)00380-7 · Cited by 16
Verma, A. A., Trbovich, P., Mamdani, M., & Shojania, K. G. (2023) · BMJ Quality & Safety · doi:10.1136/bmjqs-2022-015713 · Cited by 17
Constantinides, M., Bogucka, E., Šćepanović, S., & Quercia, D. (2024) · Proc. ACM Hum. Comput. Interact. · doi:10.1145/3676507 · Cited by 21
Feasibility of Specular Reflection Imaging for Extraction of Neck Vessel Pressure Waveforms
Saiko, G., Burton, T., & Douplik, A. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.830231 · Cited by 16
Nachman, D., Eisenkraft, A., Goldstein, N., Ishay, A. B., Fons, M., Merin, R., & Gepner, Y. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.911544 · Cited by 16
Charpignon, M., Carrel, A., Jiang, Y., Kwaga, T., Cantada, B., Hyslop, T., Cox, C. E., Haines, K., Koomson, V. J., Dumas, G., et al. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000244 · Cited by 17
Alderman, J. E., Palmer, J., Laws, E., McCradden, M. D., Ordish, J., Ghassemi, M., Pfohl, S. R., Rostamzadeh, N., Cole-Lewis, H. J., Glocker, B., et al. (2024) · NEJM AI · doi:10.1056/aip2401088 · Cited by 16
Bias in Federated Learning: A Comprehensive Survey
Benarba, N., & Bouchenak, S. (2025) · ACM Computing Surveys · doi:10.1145/3735125 · Cited by 17
Comparison of methods for characterizing skin pigment diversity in research cohorts
Lipnick, M. S., Chen, D., Law, T. J., Moore, K., Lester, J., Monk, E. P., Hendrickson, C. M., Chou, Y., Hughes, C., Behnke, E., et al. (2025) · British Journal of Dermatology · doi:10.1093/bjd/ljaf397 · Cited by 15
Nguyen, L. S., Helias, M., Raia, L., Nicolas, E., Jaubert, P., Benghanem, S., Hamou, Z. A., Dupland, P., Charpentier, J., Pène, F., et al. (2022) · Scientific Reports · doi:10.1038/s41598-021-02634-z · Cited by 15
Multiwavelength tissue-mimicking phantoms with tunable vessel pulsation
Jenne, S., & Zappe, H. P. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.28.4.045003 · Cited by 15
Towards a Race-Neutral System of Pulmonary Function Test Results Interpretation
Baugh, A. D., Adegunsoye, A., Connolly, M., Croft, D. P., Pew, K., McCormack, M. C., & Georas, S. N. (2023) · CHEST Journal · doi:10.1016/j.chest.2023.06.005 · Cited by 15
Sharma, Y., Saha, A., & Goldsack, J. C. (2024) · JMIR Public Health and Surveillance · doi:10.2196/51980 · Cited by 15
Wong, A., Robinson, L., Soroush, S., Suresh, A., Yang, D., Madu, K., Harhay, M. N., & Pourrezaei, K. (2021) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545821500164 · Cited by 15
Chew, R., Zhang, M., Chandna, A., & Lubell, Y. (2021) · BMJ Global Health · doi:10.1136/bmjgh-2021-007282 · Cited by 16
Associations between provider-assigned Apgar score and neonatal race
Edwards, S., Wheatley, C., Sutherland, M. B., & Class, Q. A. (2022) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.07.055 · Cited by 15
Fobiri, G. K., Howard, E. K., Crentsil, T., Frimpong, C., & Hughes‐Riley, T. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500008 · Cited by 14
Human Skin Models in Biophotonics: Materials, Methods, and Applications
Bajrami, D., Spano, F., Wei, K., Bonmarin, M., & Rossi, R. M. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202501894 · Cited by 14
Allado, E., Poussel, M., Moussu, A., Hily, O., Temperelli, M., Cherifi, A., Saunier, V., Bernard, Y., Albuisson, É., & Chenuel, B. J. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11206101 · Cited by 14
Optical Properties of Human Skin Phototypes and Their Correlation with Individual Angle Typology
da Cruz, L. B., Girasol, C. E., Coltro, P. S., Guirro, R. R. D. J., & Bachmann, L. (2023) · Photobiomodulation Photomedicine and Laser Surgery · doi:10.1089/photob.2022.0111 · Cited by 14
Ananny, M. (2023) · Osiris · doi:10.1086/725146 · Cited by 16
Racial effects on masimo pulse oximetry: impact of low perfusion index
Sharma, V., Barker, S. J., Sorci, R., Park, L., & Wilson, W. C. (2024) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-01113-2 · Cited by 14
Alderman, J. E., Charalambides, M., Sachdeva, G. S., Laws, E., Palmer, J., Lee, E., Menon, V., Malik, Q., Vadera, S., Calvert, M., et al. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00146-8 · Cited by 15
Rectifying COVID-19 disparities with treatment and vaccination
Carethers, J. M. (2021) · JCI Insight · doi:10.1172/jci.insight.147800 · Cited by 15
Re‐examining our roots: Queer history and anatomy
Smith, T. C. (2022) · The Anatomical Record · doi:10.1002/ar.24859 · Cited by 14
Wojtasz, I., Cofta, S., Czudaj, P., Jaracz, K., & Kaźmierski, R. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19031397 · Cited by 14
de Carvalho, E. B., Leite, T. R. S., Sacramento, R. F. D. M., do Nascimento, P. R. L., Samary, C. S., Rocco, P. R. M., & Silva, P. L. (2022) · Revista Brasileira de Terapia Intensiva · doi:10.5935/0103-507x.20220013-pt · Cited by 14
Variation in Clinical Treatment and Outcomes by Race Among US Veterans Hospitalized With COVID-19
Castro, A. D., Mayr, F., Talisa, V. B., Shaikh, O. S., Omer, S. B., Yende, S. P., & Butt, A. A. (2022) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.38507 · Cited by 14
Garnet, B., Lankenau, R. D., Jean, E., & Campos, M. (2023) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202209-837oc · Cited by 15
Kalra, A., Shou, B. L., Zhao, D. X., Wilcox, C. J., Keller, S. P., Kim, B. S., Whitman, G. J. R., Cho, S., Leng, A., Geeza, A., et al. (2023) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2023.09.019 · Cited by 14
The Global Definition of Acute Respiratory Distress Syndrome: Ready for Prime Time?
Smit, M. R., Brower, R. G., Parsons, P. E., Phua, J., & Bos, L. D. J. (2023) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202308-1369ed · Cited by 14
Pulse oximetry may underestimate hypoxaemia in black patients, study finds
Dyer, O. (2020) · BMJ · doi:10.1136/bmj.m4926 · Cited by 13
Taking the time for our bodies: How wearables can be used to assess circadian physiology
Shandhi, M. M. H., Wang, W. K., & Dunn, J. (2021) · Cell Reports Methods · doi:10.1016/j.crmeth.2021.100067 · Cited by 13
Interpretation of Oxygen Saturation in Congenital Heart Disease: Fact and Fallacy
Olsen, J., & Puri, K. (2022) · Pediatrics in Review · doi:10.1542/pir.2020-005364 · Cited by 13
Evaluation of a novel device to assess obstructive sleep apnea and body position
Raphelson, J. R., Ahmed, I. M., Ancoli‐Israel, S., Ojile, J. M., Pearson, S., Bennett, N., Uhles, M., Rohrscheib, C. E., & Malhotra, A. (2023) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10644 · Cited by 13
Uncovering Bias in Personal Informatics
Yfantidou, S., Sermpezis, P., Vakali, A. I., & Baeza-Yates, R. A. (2023) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3610914 · Cited by 16
Racial and ethnic minority participants in clinical trials of acute respiratory distress syndrome
Papoutsi, E., Kremmydas, P., Tsolaki, V., Kyriakoudi, A., Routsi, C., Kotanidou, A. N., & Siempos, I. Ι. (2023) · Intensive Care Medicine · doi:10.1007/s00134-023-07238-x · Cited by 13
Identifying and reducing barriers to having a racially and ethnically diverse research population
Harris, M. T., Statler, M. C., Montague, E. N. H., Oduor, K. F., & Stonewall, J. H. (2023) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2023.103527 · Cited by 14
Hearables: In-Ear Multimodal Data Fusion for Robust Heart Rate Estimation
Żyliński, M., Nassibi, A., Occhipinti, E., Malik, A., Bermond, M., Davies, H. J., & Mandic, D. P. (2024) · BioMedInformatics · doi:10.3390/biomedinformatics4020051 · Cited by 13
Metadata
- Authors
- Sjoding, M. W., Dickson, R. P., Iwashyna, T. J., Gay, S. E., & Valley, T. S.
- Affiliations
- University of Michigan (US)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2020-12-17
- Volume
- 383
- Issue
- 25
- Pages
- 2477-2478
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- PMC
- PMC7808260
- OpenAlex
- W3111737151
- Cited by
- 1,114
- References
- 3
- Citations by year
- 2026: 191 · 2025: 182 · 2024: 193 · 2023: 227 · 2022: 209 · 2021: 109 · 2020: 1
- FWCI
- 42.90
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Health Services Research and Development (IIR 17-045)
- National Heart, Lung, and Blood Institute (K01 HL136687, K12 HL138039, K23 HL140165, R01 HL144599)
- U.S. National Library of Medicine (R01 LM013325)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Computer Science › Artificial Intelligence › Ethics and Social Impacts of AI
- Social Sciences › Anthropology › Race, Genetics, and Society
- Keywords
- pulse oximetry, racial bias, skin pigmentation, oxygen saturation measurement, measurement error, racial disparities in health care
- MeSH terms
- Adult, Hypoxia, Black or African American, Female, Humans, Male, Oximetry, Oxygen, White People, Organ Dysfunction Scores, Racism
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review