The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary Artery
Open accessAbstract
BACKGROUND: Preliminary reports of studies involving simple coronary lesions indicate that a sirolimus-eluting stent significantly reduces the risk of restenosis after percutaneous coronary revascularization. METHODS: We conducted a randomized, double-blind trial comparing a sirolimus-eluting stent with a standard stent in 1058 patients at 53 centers in the United States who had a newly diagnosed lesion in a native coronary artery. The coronary disease in these patients was complex because of the frequent presence of diabetes (in 26 percent of patients), the high percentage of patients with longer lesions (mean, 14.4 mm), and small vessels (mean, 2.80 mm). The primary end point was failure of the target vessel (a composite of death from cardiac causes, myocardial infarction, and repeated percutaneous or surgical revascularization of the target vessel) within 270 days. RESULTS: The rate of failure of the target vessel was reduced from 21.0 percent with a standard stent to 8.6 percent with a sirolimus-eluting stent (P<0.001)--a reduction that was driven largely by a decrease in the frequency of the need for revascularization of the target lesion (16.6 percent in the standard-stent group vs. 4.1 percent in the sirolimus-stent group, P<0.001). The frequency of neointimal hyperplasia within the stent was also decreased in the group that received sirolimus-eluting stents, as assessed by both angiography and intravascular ultrasonography. Subgroup analyses revealed a reduction in the rates of angiographic restenosis and target-lesion revascularization in all subgroups examined. CONCLUSIONS: In this randomized clinical trial involving patients with complex coronary lesions, the use of a sirolimus-eluting stent had a consistent treatment effect, reducing the rates of restenosis and associated clinical events in all subgroups analyzed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citationMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Angiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Self-citationSousa, J. E., Costa, M. A., Abizaid, A., Abizaid, A. S., Feres, F., Pinto, I. M. F., Seixas, A. C., Staico, R., Mattos, L. A., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.2.192 · Cited by 793
Self-citationStent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Self-citationSousa, J. E., Costa, M. A., Abizaid, A. C., Rensing, B. J., Abizaid, A. S., Tanajura, L. F., Kozuma, K., Van Langenhove, G., Sousa, A. G. M. R., Falotico, R., et al. (2001) · Circulation · doi:10.1161/hc4201.098056 · Cited by 672
Self-citationRoubin, G. S., Cannon, A. D., Agrawal, S. K., Macander, P. J., Dean, L. S., Baxley, W. A., & Breland, J. (1992) · Circulation · doi:10.1161/01.cir.85.3.916 · Cited by 582
Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents
Kimura, T., Yokoi, H., Nakagawa, Y., Tamura, T., Kaburagi, S., Sawada, Y., Sato, Y., Yokoi, H., Hamasaki, N., Nosaka, H., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340903 · Cited by 507
Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement
Elezi, S., Kastrati, A., Pache, J., Wehinger, A., Hadamitzky, M., Dirschinger, J., Neumann, F.-J., & Schömig, A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00467-7 · Cited by 495
Gallo, R., Padurean, A., Jayaraman, T., Marx, S., Roque, M., Adelman, S., Chesebro, J., Fallon, J., Fuster, V., Marks, A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.16.2164 · Cited by 490
Vessel Size and Long-Term Outcome After Coronary Stent Placement
Elezi, S., Kastrati, A., Neumann, F.-J., Hadamitzky, M., Dirschinger, J., & Schömig, A. (1998) · Circulation · doi:10.1161/01.cir.98.18.1875 · Cited by 484
Abizaid, A., Kornowski, R., Mintz, G. S., Hong, M. K., Abizaid, A. S., Mehran, R., Pichard, A. D., Kent, K. M., Satler, L. F., Wu, H., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00286-1 · Cited by 458
Self-citationA Paclitaxel-Eluting Stent for the Prevention of Coronary Restenosis
Park, S.-J., Shim, W. H., Ho, D. S., Raizner, A. E., Park, S.-W., Hong, M.-K., Lee, C. W., Choi, D., Jang, Y., Lam, R., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021007 · Cited by 456
Bench to Bedside: The Development of Rapamycin and Its Application to Stent Restenosis
Marx, S. O., & Marks, A. R. (2001) · Circulation · doi:10.1161/01.cir.104.8.852 · Cited by 447
Heldman, A. W., Cheng, L., Jenkins, G. M., Heller, P. F., Kim, D.-W., Ware, M., Nater, C., Hruban, R. H., Rezai, B., Abella, B. S., et al. (2001) · Circulation · doi:10.1161/01.cir.103.18.2289 · Cited by 435
Drachman, D. E., Edelman, E. R., Seifert, P., Groothuis, A. R., Bornstein, D. A., Kamath, K. R., Palasis, M., Yang, D., Nott, S. H., & Rogers, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01020-2 · Cited by 286
Stented segment length as an independent predictor of restenosis
Kobayashi, Y., De Gregorio, J., Kobayashi, N., Akiyama, T., Reimers, B., Finci, L., Di Mario, C., & Colombo, A. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00303-4 · Cited by 283
Local paclitaxel delivery for the prevention of restenosis: biological effects and efficacy in vivo
Herdeg, C., Oberhoff, M., Baumbach, A., Blattner, A., Axel, D. I., Schröder, S., Heinle, H., & Karsch, K. R. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00614-8 · Cited by 276
Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) Trial
Holmes, D. R., Savage, M., LaBlanche, J.-M., Grip, L., Serruys, P. W., Fitzgerald, P., Fischman, D., Goldberg, S., Brinker, J. A., Zeiher, A. M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000028335.31300.da · Cited by 260
Self-citationInfluence of lesion length on restenosis after coronary stent placement
Kastrati, A., Elezi, S., Dirschinger, J., Hadamitzky, M., Neumann, F.-J., & Schömig, A. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00165-4 · Cited by 210
Rensing, B. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2892 · Cited by 183
Improved Clinical Outcome after Widespread Use of Coronary-Artery Stenting in Canada
Rankin, J. M., Spinelli, J. J., Carere, R. G., Ricci, D. R., Penn, I. M., Hilton, A., Henderson, M. A., HAYDEN, R. I., & Buller, C. E. H. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912233412602 · Cited by 116
Wilensky, R. L., Tanguay, J., Ito, S., Bartorelli, A. L., Moses, J. W., Williams, D. O., Bailey, S. R., Martin, J. L., Bucher, T. A., Gallant, P., et al. (2000) · American Heart Journal · doi:10.1067/mhj.2000.106614 · Cited by 32
Self-citation
Cited by
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
Developed with the special contribution of the European Association for Percutaneous Cardiovascular Interventions (EAPCI), Authors/Task Force Members, Wijns, W., Kolh, P., Danchin, N., Di Mario, C., Falk, V., Folliguet, T., Garg, S., Huber, K., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq277 · Cited by 3,184
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Self-citation
Metadata
- Authors
- Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., Jaeger, J. L., & Kuntz, R. E.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2003-10-02
- Volume
- 349
- Issue
- 14
- Pages
- 1315-1323
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2083630382
- Cited by
- 4,224
- References
- 25
- FWCI
- 316.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.