The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Open accessAbstract
BACKGROUND: Patients with heart failure who receive an implantable cardioverter-defibrillator (ICD) for primary prevention (i.e., prevention of a first life-threatening arrhythmic event) may later receive therapeutic shocks from the ICD. Information about long-term prognosis after ICD therapy in such patients is limited. METHODS: Of 829 patients with heart failure who were randomly assigned to ICD therapy, we implanted the ICD in 811. ICD shocks that followed the onset of ventricular tachycardia or ventricular fibrillation were considered to be appropriate. All other ICD shocks were considered to be inappropriate. RESULTS: Over a median follow-up period of 45.5 months, 269 patients (33.2%) received at least one ICD shock, with 128 patients receiving only appropriate shocks, 87 receiving only inappropriate shocks, and 54 receiving both types of shock. In a Cox proportional-hazards model adjusted for baseline prognostic factors, an appropriate ICD shock, as compared with no appropriate shock, was associated with a significant increase in the subsequent risk of death from all causes (hazard ratio, 5.68; 95% confidence interval [CI], 3.97 to 8.12; P<0.001). An inappropriate ICD shock, as compared with no inappropriate shock, was also associated with a significant increase in the risk of death (hazard ratio, 1.98; 95% CI, 1.29 to 3.05; P=0.002). For patients who survived longer than 24 hours after an appropriate ICD shock, the risk of death remained elevated (hazard ratio, 2.99; 95% CI, 2.04 to 4.37; P<0.001). The most common cause of death among patients who received any ICD shock was progressive heart failure. CONCLUSIONS: Among patients with heart failure in whom an ICD is implanted for primary prevention, those who receive shocks for any arrhythmia have a substantially higher risk of death than similar patients who do not receive such shocks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Self-citationAmiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Self-citationACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Hlatky, M. A., Boineau, R. E., Higginbotham, M. B., Lee, K. L., Mark, D. B., Califf, R. M., Cobb, F. R., & Pryor, D. B. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)90496-7 · Cited by 1,736
Self-citationWILKOFF, B. L., HESS, M., YOUNG, J., & ABRAHAM, W. T. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03625.x · Cited by 835
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zareba, W., Cannom, D. S., McNitt, S., Rosero, S. Z., Wang, P., Schuger, C., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 813
Self-citationWathen, M. S., DeGroot, P. J., Sweeney, M. O., Stark, A. J., Otterness, M. F., Adkisson, W. O., Canby, R. C., Khalighi, K., Machado, C., Rubenstein, D. S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000145610.64014.e4 · Cited by 775
Swedberg, K., Olsson, L. G., Charlesworth, A., Cleland, J., Hanrath, P., Komajda, M., Metra, M., Torp-Pedersen, C., & Poole-Wilson, P. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi166 · Cited by 647
Moss, A. J., Greenberg, H., Case, R. B., Zareba, W., Hall, W. J., Brown, M. W., Daubert, J. P., McNitt, S., Andrews, M. L., & Elkin, A. D. (2004) · Circulation · doi:10.1161/01.cir.0000150390.04704.b7 · Cited by 597
Cited by
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Reduction in Inappropriate Therapy and Mortality through ICD Programming
Moss, A. J., Schuger, C., Beck, C. A., Brown, M. W., Cannom, D. S., Daubert, J. P., Estes, N. A. M., Greenberg, H., Hall, W. J., Huang, D. T., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1211107 · Cited by 1,378
Self-citationGulati, A., Jabbour, A., Ismail, T. F., Guha, K., Khwaja, J., Raza, S., Morarji, K., Brown, T. D. H., Ismail, N. A., Dweck, M. R., et al. (2013) · JAMA · doi:10.1001/jama.2013.1363 · Cited by 1,179
Kuck, K.-H., Schaumann, A., Eckardt, L., Willems, S., Ventura, R., Delacrétaz, E., Pitschner, H.-F., Kautzner, J., Schumacher, B., & Hansen, P. S. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61755-4 · Cited by 799
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citationHindricks, G., Taborsky, M., Glikson, M., Heinrich, U., Schumacher, B., Katz, A., Brachmann, J., Lewalter, T., Goette, A., Block, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61176-4 · Cited by 740
Defibrillator implantation early after myocardial infarction
Steinbeck, G., Andresen, D., Seidl, K., Brachmann, J., Hoffmann, E., Wojciechowski, D., Kornacewicz-Jach, Z., Sredniawa, B., Lupkovics, G., Hofgärtner, F., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901889 · Cited by 690
Nunes, M. C. P., Beaton, A., Acquatella, H., Bern, C., Bolger, A. F., Echeverría, L. E., Dutra, W. O., Gascon, J., Morillo, C. A., Oliveira-Filho, J., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000599 · Cited by 583
Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator
Weiss, R., Knight, B. P., Gold, M. R., Leon, A. R., Herre, J. M., Hood, M., Rashtian, M., Kremers, M., Crozier, I., Lee, K. L., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.003042 · Cited by 557
Self-citationSaxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515
Tung, R., Vaseghi, M., Frankel, D. S., Vergara, P., Di Biase, L., Nagashima, K., Yu, R., Vangala, S., Tseng, C.-H., Choi, E.-K., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.036 · Cited by 499
Self-citationSubcutaneous or Transvenous Defibrillator Therapy
Knops, R. E., Olde Nordkamp, L. R. A., Delnoy, P.-P. H. M., Boersma, L. V. A., Kuschyk, J., El-Chami, M. F., Bonnemeier, H., Behr, E. R., Brouwer, T. F., Kääb, S., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1915932 · Cited by 483
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citationArevalo, H. J., Vadakkumpadan, F., Guallar, E., Jebb, A., Malamas, P., Wu, K. C., & Trayanova, N. A. (2016) · Nature Communications · doi:10.1038/ncomms11437 · Cited by 465
Inappropriate Implantable Cardioverter-Defibrillator Shocks
van Rees, J. B., Borleffs, C. J. W., de Bie, M. K., Stijnen, T., van Erven, L., Bax, J. J., & Schalij, M. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.059 · Cited by 451
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationDi Biase, L., Santangeli, P., Burkhardt, D. J., Bai, R., Mohanty, P., Carbucicchio, C., Dello Russo, A., Casella, M., Mohanty, S., Pump, A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.044 · Cited by 422
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Self-citationGasparini, M., Proclemer, A., Klersy, C., Kloppe, A., Lunati, M., Ferrer, J. B. M., Hersi, A., Gulaj, M., Wijfels, M. C. E. F., Santi, E., et al. (2013) · JAMA · doi:10.1001/jama.2013.4598 · Cited by 407
Whellan, D. J., Ousdigian, K. T., Al-Khatib, S. M., Pu, W., Sarkar, S., Porter, C. B., Pavri, B. B., & O'Connor, C. M. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.089 · Cited by 374
Cardiac Sympathetic Denervation for Refractory Ventricular Arrhythmias
Vaseghi, M., Barwad, P., Malavassi Corrales, F. J., Tandri, H., Mathuria, N., Shah, R., Sorg, J. M., Gima, J., Mandal, K., Sàenz Morales, L. C., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.04.035 · Cited by 348
Stout, K. K., Broberg, C. S., Book, W. M., Cecchin, F., Chen, J. M., Dimopoulos, K., Everitt, M. D., Gatzoulis, M., Harris, L., Hsu, D. T., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000352 · Cited by 346
Sweeney, M. O., Sherfesee, L., DeGroot, P. J., Wathen, M. S., & Wilkoff, B. L. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2009.11.027 · Cited by 345
Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry
Boersma, L., Barr, C., Knops, R., Theuns, D., Eckardt, L., Neuzil, P., Scholten, M., Hood, M., Kuschyk, J., Jones, P., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.06.040 · Cited by 331
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Europace · doi:10.1093/europace/euu194 · Cited by 327
Self-citationWilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.07.024 · Cited by 288
Self-citationVentricular arrhythmias and sudden cardiac death
John, R. M., Tedrow, U. B., Koplan, B. A., Albert, C. M., Epstein, L. M., Sweeney, M. O., Miller, A. L., Michaud, G. F., & Stevenson, W. G. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61413-5 · Cited by 286
Das, M. K., Maskoun, W., Shen, C., Michael, M. A., Suradi, H., Desai, M., Subbarao, R., & Bhakta, D. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2009.09.065 · Cited by 280
Dunbar, S. B., Dougherty, C. M., Sears, S. F., Carroll, D. L., Goldstein, N. E., Mark, D. B., McDaniel, G., Pressler, S. J., Schron, E., Wang, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31825d59fd · Cited by 221
Self-citationNielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
Maytin, M., Love, C. J., Fischer, A., Carrillo, R. G., Garisto, J. D., Bongiorni, M. G., Segreti, L., John, R. M., Michaud, G. F., Albert, C. M., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.03.058 · Cited by 89
Ghezzi, E. S., Sharman, R. L. S., Selvanayagam, J. B., Psaltis, P. J., Sanders, P., Astley, J. M., Knayfati, S., Batra, V., & Keage, H. A. D. (2023) · Europace · doi:10.1093/europace/euad130 · Cited by 73
PEDERSEN, S. S., VAN DEN BROEK, K. C., VAN DEN BERG, M., & THEUNS, D. A. M. J. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02845.x · Cited by 63
Implantable Cardioverter‐Defibrillators for Secondary Prevention of Sudden Cardiac Death: A Review
Borne, R. T., Katz, D., Betz, J., Peterson, P. N., & Masoudi, F. A. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.005515 · Cited by 43
Qintar, M., George, J. J., Panko, M., Bea, S., Broer, K. A., St. John, J., Blissett, K.-A., Ching, E., Sears, S. F., Pedersen, S. S., et al. (2015) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-015-9990-7 · Cited by 30
Ruwald, M. H., Zareba, W., Jons, C., Zhang, C., Ruwald, A.-C. H., Olshansky, B., McNitt, S., Bloch Thomsen, P. E., Shoda, M., Merkely, B., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.002472 · Cited by 30
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28
Metadata
- Authors
- Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R. K., Marchlinski, F. E., Yee, R., Guarnieri, T., Talajic, M., Wilber, D. J., Fishbein, D. P., Packer, D. L., Mark, D. B., Lee, K. L., & Bardy, G. H.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2008-09-04
- Volume
- 359
- Issue
- 10
- Pages
- 1009-1017
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2161984704
- Cited by
- 1,462
- References
- 17
- FWCI
- 54.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.