The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Open accessAbstract
BACKGROUND: The growing use of imaging procedures in the United States has raised concerns about exposure to low-dose ionizing radiation in the general population. METHODS: We identified 952,420 nonelderly adults (between 18 and 64 years of age) in five health care markets across the United States between January 1, 2005, and December 31, 2007. Utilization data were used to estimate cumulative effective doses of radiation from imaging procedures and to calculate population-based rates of exposure, with annual effective doses defined as low (< or = 3 mSv), moderate (> 3 to 20 mSv), high (> 20 to 50 mSv), or very high (> 50 mSv). RESULTS: During the study period, 655,613 enrollees (68.8%) underwent at least one imaging procedure associated with radiation exposure. The mean (+/-SD) cumulative effective dose from imaging procedures was 2.4+/-6.0 mSv per enrollee per year; however, a wide distribution was noted, with a median effective dose of 0.1 mSv per enrollee per year (interquartile range, 0.0 to 1.7). Overall, moderate effective doses of radiation were incurred in 193.8 enrollees per 1000 per year, whereas high and very high doses were incurred in 18.6 and 1.9 enrollees per 1000 per year, respectively. In general, cumulative effective doses of radiation from imaging procedures increased with advancing age and were higher in women than in men. Computed tomographic and nuclear imaging accounted for 75.4% of the cumulative effective dose, with 81.8% of the total administered in outpatient settings. CONCLUSIONS: Imaging procedures are an important source of exposure to ionizing radiation in the United States and can result in high cumulative effective doses of radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
Brenner, D. J., Doll, R., Goodhead, D. T., Hall, E. J., Land, C. E., Little, J. B., Lubin, J. H., Preston, D. L., Preston, R. J., Puskin, J. S., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2235592100 · Cited by 1,765
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Self-citationBenefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
Rising Use Of Diagnostic Medical Imaging In A Large Integrated Health System
Smith-Bindman, R., Miglioretti, D. L., & Larson, E. B. (2008) · Health Affairs · doi:10.1377/hlthaff.27.6.1491 · Cited by 828
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Self-citation
Cited by
Liquid biopsies come of age: Towards implementation of circulating tumour DNA
Wan, J. C. M., Massie, C., Garcia-Corbacho, J., Mouliere, F., Brenton, J. D., Caldas, C., Pacey, S., Baird, R., & Rosenfeld, N. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.7 · Cited by 2,809
Rappaport, T. S., Xing, Y., Kanhere, O., Ju, S., Madanayake, A., Mandal, S., Alkhateeb, A., & Trichopoulos, G. C. (2019) · IEEE Access · doi:10.1109/access.2019.2921522 · Cited by 2,617
“Ionizing radiation can be used for gauging the thickness of metals, Roentgen Stereophotogrammetry, astronomy, nuclear medicine, sterilizing medical equipment, and pasteurizing certain foods and spices [15].”
BackgroundTrends in Thyroid Cancer Incidence and Mortality in the United States, 1974-2013
Lim, H., Devesa, S. S., Sosa, J. A., Check, D., & Kitahara, C. M. (2017) · JAMA · doi:10.1001/jama.2017.2719 · Cited by 2,159
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Curigliano, G., Lenihan, D., Fradley, M., Ganatra, S., Barac, A., Blaes, A., Herrmann, J., Porter, C., Lyon, A. R., Lancellotti, P., et al. (2020) · Annals of Oncology · doi:10.1016/j.annonc.2019.10.023 · Cited by 1,031
“Non-ionising radiation modalities may be most appropriate due to concerns regarding cumulative radiation dose in cancer patients,(85) as traditional MUGA scanning can expose patients to significant radiation with each exam.(86) It is also recognised that echocardiography provides substantial additional information on…”
BackgroundSmith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898
“For analyses that ignored modality, we estimated the individual radiation dose per year and calculated descriptive statistics in annual radiation exposure, including the percentage of enrollees who underwent a high annual radiation exposure (defined as 20-50 mSv)(11,20) or a very high radiation exposure ( 50 mSv).(11,…”
Association Between MRI Exposure During Pregnancy and Fetal and Childhood Outcomes
Ray, J. G., Vermeulen, M. J., Bharatha, A., Montanera, W. J., & Park, A. L. (2016) · JAMA · doi:10.1001/jama.2016.12126 · Cited by 845
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Alberg, A. J., Brock, M. V., & Samet, J. M. (2016) · Murray and Nadel's Textbook of Respiratory Medicine · doi:10.1016/b978-1-4557-3383-5.00052-x · Cited by 781
Alberg, A. J., Brock, M. V., Ford, J. G., Samet, J. M., & Spivack, S. D. (2013) · Chest · doi:10.1378/chest.12-2345 · Cited by 737
Addressing Overutilization in Medical Imaging
Hendee, W. R., Becker, G. J., Borgstede, J. P., Bosma, J., Casarella, W. J., Erickson, B. A., Maynard, C. D., Thrall, J. H., & Wallner, P. E. (2010) · Radiology · doi:10.1148/radiol.10100063 · Cited by 619
Goldstein, J. A., Chinnaiyan, K. M., Abidov, A., Achenbach, S., Berman, D. S., Hayes, S. W., Hoffmann, U., Lesser, J. R., Mikati, I. A., O'Neil, B. J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.03.068 · Cited by 583
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528
Chou, R., Qaseem, A., Owens, D. K., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-3-201102010-00008 · Cited by 518
Walsh, T. J., Gamaletsou, M. N., McGinnis, M. R., Hayden, R. T., & Kontoyiannis, D. P. (2012) · Clinical Infectious Diseases · doi:10.1093/cid/cir868 · Cited by 386
Pelliccia, A., Caselli, S., Sharma, S., Basso, C., Bax, J. J., Corrado, D., D’Andrea, A., D’Ascenzi, F., Di Paolo, F. M., Edvardsen, T., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx532 · Cited by 368
Rehani, M. M., Ciraj-Bjelac, O., Vañó, E., Miller, D. L., Walsh, S., Giordano, B. D., & Persliden, J. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2012.03.001 · Cited by 344
Quantification of Liver Fat with Magnetic Resonance Imaging
Reeder, S. B., & Sirlin, C. B. (2010) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2010.08.013 · Cited by 342
Korley, F. K., Pham, J. C., & Kirsch, T. D. (2010) · JAMA · doi:10.1001/jama.2010.1408 · Cited by 335
Computed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335
Chronic Coronary Artery Disease: Diagnosis and Management
Cassar, A., Holmes, D. R., Rihal, C. S., & Gersh, B. J. (2009) · Mayo Clinic Proceedings · doi:10.4065/mcp.2009.0391 · Cited by 324
Beyer, J., Albers, P., Altena, R., Aparicio, J., Bokemeyer, C., Busch, J., Cathomas, R., Cavallin-Stahl, E., Clarke, N. W., Claßen, J., et al. (2013) · Annals of Oncology · doi:10.1093/annonc/mds579 · Cited by 320
Valente, A. M., Cook, S., Festa, P., Ko, H. H., Krishnamurthy, R., Taylor, A. M., Warnes, C. A., Kreutzer, J., & Geva, T. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.11.009 · Cited by 317
How I treat common variable immune deficiency
Cunningham-Rundles, C. (2010) · Blood · doi:10.1182/blood-2010-01-254417 · Cited by 316
Radiation safety program for the cardiac catheterization laboratory
E. Chambers, C., A. Fetterly, K., Holzer, R., Paul Lin, P., C. Blankenship, J., Balter, S., & K. Laskey, W. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22867 · Cited by 301
Kussmaul, W. G. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-10-201211200-00015 · Cited by 296
Tian, F., Zhang, S., Liu, C., Han, Z., Liu, Y., Deng, J., Li, Y., Wu, X., Cai, L., Qin, L., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22913-7 · Cited by 291
Kones, R. (2011) · Drug Design, Development and Therapy · doi:10.2147/dddt.s14934 · Cited by 259
Appropriate use of lumbar imaging for evaluation of low back pain
Chou, R., Deyo, R. A., & Jarvik, J. G. (2012) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2012.04.005 · Cited by 165
Perrone-Filardi, P., Achenbach, S., Möhlenkamp, S., Reiner, Z., Sambuceti, G., Schuijf, J. D., Van der Wall, E., Kaufmann, P. A., Knuuti, J., Schroeder, S., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq235 · Cited by 149
Raff, G. L., Chinnaiyan, K. M., Cury, R. C., Garcia, M. T., Hecht, H. S., Hollander, J. E., O'Neil, B., Taylor, A. J., & Hoffmann, U. (2014) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2014.06.002 · Cited by 147
Convolutional auto-encoder for image denoising of ultra-low-dose CT
Nishio, M., Nagashima, C., Hirabayashi, S., Ohnishi, A., Sasaki, K., Sagawa, T., Hamada, M., & Yamashita, T. (2017) · Heliyon · doi:10.1016/j.heliyon.2017.e00393 · Cited by 106
The SINAPSE Collaborative Group, Wardlaw, J. M., Brindle, W., Casado, A. M., Shuler, K., Henderson, M., Thomas, B., Macfarlane, J., Muñoz Maniega, S., Lymer, K., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2500-8 · Cited by 94
Jonas, D. E., Reddy, S., Middleton, J. C., Barclay, C., Green, J., Baker, C., & Asher, G. N. (2018) · JAMA · doi:10.1001/jama.2018.6897 · Cited by 78
Metadata
- Authors
- Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Chen, J., Ting, H. H., Shah, N. D., Nasir, K., Einstein, A. J., & Nallamothu, B. K.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2009-08-27
- Volume
- 361
- Issue
- 9
- Pages
- 849-857
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2041998362
- Cited by
- 1,338
- References
- 27
- FWCI
- 106.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.