The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Power spectrum analysis for optical tweezers
Abstract
The force exerted by an optical trap on a dielectric bead in a fluid is often found by fitting a Lorentzian to the power spectrum of Brownian motion of the bead in the trap. We present explicit functions of the experimental power spectrum that give the values of the parameters fitted, including error bars and correlations, for the best such χ2 fit in a given frequency range. We use these functions to determine the information content of various parts of the power spectrum, and find, at odds with lore, much information at relatively high frequencies. Applying the method to real data, we obtain perfect fits and calibrate tweezers with less than 1% error when the trapping force is not too strong. Relatively strong traps have power spectra that cannot be fitted properly with any Lorentzian, we find. This underscores the need for better understanding of the power spectrum than the Lorentzian provides. This is achieved using old and new theory for Brownian motion in an incompressible fluid, and new results for a popular photodetection system. The trap and photodetection system are then calibrated simultaneously in a manner that makes optical tweezers a tool of precision for force spectroscopy, local viscometry, and probably other applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of chemistry and physics
(1930) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(30)91499-8 · Cited by 11,721
Numerical Recipes, The Art of Scientific Computing
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., & Gould, H. (1987) · American Journal of Physics · doi:10.1119/1.14981 · Cited by 10,024
Smith, S. B., Cui, Y., & Bustamante, C. (1996) · Science · doi:10.1126/science.271.5250.795 · Cited by 2,770
Biological Applications of Optical Forces
Svoboda, K., & Block, S. M. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.001335 · Cited by 1,792
Stretching DNA with optical tweezers
Wang, M. D., Yin, H., Landick, R., Gelles, J., & Block, S. M. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78780-0 · Cited by 1,481
Optical trapping and manipulation of neutral particles using lasers
Ashkin, A. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.10.4853 · Cited by 1,474
Low Reynolds number hydrodynamics: with special applications to particulate media
Happel, J., & Brenner, H. (1983) · Mechanics of fluids and transport processes · doi:10.1007/978-94-009-8352-6 · Cited by 1,354
Folding-Unfolding Transitions in Single Titin Molecules Characterized with Laser Tweezers
Kellermayer, M. S. Z., Smith, S. B., Granzier, H. L., & Bustamante, C. (1997) · Science · doi:10.1126/science.276.5315.1112 · Cited by 1,217
Single kinesin molecules studied with a molecular force clamp
Visscher, K., Schnitzer, M. J., & Block, S. M. (1999) · Nature · doi:10.1038/22146 · Cited by 1,027
Force and Velocity Measured for Single Molecules of RNA Polymerase
Wang, M. D., Schnitzer, M. J., Yin, H., Landick, R., Gelles, J., & Block, S. M. (1998) · Science · doi:10.1126/science.282.5390.902 · Cited by 892
Kinesin hydrolyses one ATP per 8-nm step
Schnitzer, M. J., & Block, S. M. (1997) · Nature · doi:10.1038/41111 · Cited by 771
Single-Molecule Biomechanics with Optical Methods
Mehta, A. D., Rief, M., Spudich, J. A., Smith, D. A., & Simmons, R. M. (1999) · Science · doi:10.1126/science.283.5408.1689 · Cited by 666
Interference model for back-focal-plane displacement detection in optical tweezers
Gittes, F., & Schmidt, C. F. (1998) · Optics Letters · doi:10.1364/ol.23.000007 · Cited by 623
Microscopic Viscoelasticity: Shear Moduli of Soft Materials Determined from Thermal Fluctuations
Gittes, F., Schnurr, B., Olmsted, P. D., MacKintosh, F. C., & Schmidt, C. F. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.3286 · Cited by 550
Quantitative measurements of force and displacement using an optical trap
Simmons, R. M., Finer, J. T., Chu, S., & Spudich, J. A. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79746-1 · Cited by 506
Construction of multiple-beam optical traps with nanometer-resolution position sensing
Visscher, K., Gross, S. P., & Block, S. M. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577338 · Cited by 419
Schnurr, B., Gittes, F., MacKintosh, F. C., & Schmidt, C. F. (1997) · Macromolecules · doi:10.1021/ma970555n · Cited by 379
Three-dimensional high-resolution particle tracking for optical tweezers by forward scattered light
Pralle, A., Prummer, M., Florin, E.-L., Stelzer, E. H. K., & H�rber, J. K. H. (1999) · Microscopy Research and Technique · doi:10.1002/(sici)1097-0029(19990301)44:5<378::aid-jemt10>3.0.co;2-z · Cited by 331
The motor protein myosin-I produces its working stroke in two steps
Veigel, C., Coluccio, L. M., Jontes, J. D., Sparrow, J. C., Milligan, R. A., & Molloy, J. E. (1999) · Nature · doi:10.1038/19104 · Cited by 317
Photonic force microscope calibration by thermal noise analysis
Florin, E., Pralle, A., Stelzer, E. H. K., & Hörber, J. K. H. (1998) · Applied Physics A · doi:10.1007/s003390051103 · Cited by 238
Veigel, C., Bartoo, M. L., White, D. C. S., Sparrow, J. C., & Molloy, J. E. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74061-5 · Cited by 238
Chapter 8 Signals and Noise in Micromechanical Measurements
Gittes, F., & Schmidt, C. F. (1997) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)60406-9 · Cited by 219
Measurement of small forces using an optical trap
Ghislain, L. P., Switz, N. A., & Webb, W. W. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144613 · Cited by 213
Brownian motion and fluctuating hydrodynamics
Bedeaux, D., & Mazur, P. (1974) · Physica · doi:10.1016/0031-8914(74)90198-0 · Cited by 160
[38] Versatile optical traps with feedback control
Visscher, K. M., & Block, S. M. (1998) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(98)98040-5 · Cited by 154
Calibration of optical tweezers with differential interference contrast signals
Capitanio, M., Romano, G., Ballerini, R., Giuntini, M., Pavone, F. S., Dunlap, D. D., & Finzi, L. (2002) · Review of Scientific Instruments · doi:10.1063/1.1460929 · Cited by 106
Unintended filtering in a typical photodiode detection system for optical tweezers
Berg‐Sørensen, K., Oddershede, L. B., Florin, E., & Flyvbjerg, H. (2003) · Journal of Applied Physics · doi:10.1063/1.1554755 · Cited by 101
Self-citationBlock, S. M. (1997) · Nature · doi:10.1038/386217a0 · Cited by 50
Oddershede, L. B., Flyvbjerg, H., & rensen, K. B.-S. (2003) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/15/18/307 · Cited by 11
Self-citation
Cited by
Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
Neuman, K. C., & Block, S. M. (2004) · Review of Scientific Instruments · doi:10.1063/1.1785844 · Cited by 2,165
Recent Advances in Optical Tweezers
Moffitt, J. R., Chemla, Y. R., Smith, S. B., & Bustamante, C. (2008) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.043007.090225 · Cited by 1,084
Optical trapping and manipulation of nanostructures
Maragò, O. M., Jones, P. H., Gucciardi, P. G., Volpe, G., & Ferrari, A. C. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.208 · Cited by 1,043
Optimized localization analysis for single-molecule tracking and super-resolution microscopy
Mortensen, K. I., Churchman, L. S., Spudich, J. A., & Flyvbjerg, H. (2010) · Nature Methods · doi:10.1038/nmeth.1447 · Cited by 871
Self-citation
Metadata
- Authors
- Berg-Sørensen, K., & Flyvbjerg, H.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2004-03-01
- Volume
- 75
- Issue
- 3
- Pages
- 594-612
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2033257199
- Cited by
- 918
- References
- 29
- FWCI
- 15.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.