The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bile canaliculi formation by aligning rat primary hepatocytes in a microfluidic device
Open accessAbstract
In this study, we propose a microfluidic cell culture device mimicking the microscopic structure in liver tissue called hepatic cords. The cell culture area of the device was designed to align hepatocytes in two lines in a similar way to hepatic cords. Thanks to the structural design together with a cell seeding procedure, rat primary hepatocytes were successfully aligned in two lines and cultured under perfusion condition. It is shown that aligned hepatocytes gradually self-organize and form bile canaliculi along the hepatic cord-like structure. The present technique to culture hepatocytes with functional bile canaliculi could be used as an alternative to animal testing in the field of drug discovery and toxicological studies, and also be beneficial to tissue engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Microfabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Recent advances in bioprinting techniques: approaches, applications and future prospects
Li, J., Chen, M., Fan, X., & Zhou, H. (2016) · Journal of Translational Medicine · doi:10.1186/s12967-016-1028-0 · Cited by 608
Organ/body-on-a-chip based on microfluidic technology for drug discovery
Kimura, H., Sakai, Y., & Fujii, T. (2018) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2017.11.003 · Cited by 435
Self-citationAchberger, K., Probst, C., Haderspeck, J., Bolz, S., Rogal, J., Chuchuy, J., Nikolova, M., Cora, V., Antkowiak, L., Haq, W., et al. (2019) · eLife · doi:10.7554/elife.46188 · Cited by 380
Towards artificial tissue models: past, present, and future of 3D bioprinting
Arslan-Yildiz, A., Assal, R. E., Chen, P., Guven, S., Inci, F., & Demirci, U. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014103 · Cited by 301
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Organs-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Ma, C., Zhao, L., Zhou, E.-M., Xu, J., Shen, S., & Wang, J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03869 · Cited by 145
Bioengineering approaches to guide stem cell-based organogenesis
Gjorevski, N., Ranga, A., & Lutolf, M. P. (2014) · Development · doi:10.1242/dev.101048 · Cited by 137
An On-Chip Small Intestine–Liver Model for Pharmacokinetic Studies
Kimura, H., Ikeda, T., Nakayama, H., Sakai, Y., & Fujii, T. (2015) · SLAS Technology · doi:10.1177/2211068214557812 · Cited by 136
Self-citationEngineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90
“To eliminate the endothelial cells altogether, some groups have developed devices that simulate the endothelial fenestrations with artificial barrier slits [37,53,54]; however, such devices are devoid of PHH-LSEC crosstalk, which is important in liver diseases [55].”
BackgroundThree Dimensional Microfluidic Cell Arrays for ex Vivo Drug Screening with Mimicked Vascular Flow
Dereli-Korkut, Z., Akaydin, H. D., Ahmed, A. H. R., Jiang, X., & Wang, S. (2014) · Analytical Chemistry · doi:10.1021/ac403899j · Cited by 62
Shinha, K., Nihei, W., Nakamura, H., Goto, T., Kawanishi, T., Ishida, N., Yamazaki, N., Imakura, Y., Mima, S., Inamura, K., et al. (2021) · Micromachines · doi:10.3390/mi12091007 · Cited by 36
Self-citationBiotechnological advances and applications of human pluripotent stem cell-derived heart models
Muniyandi, P., O’Hern, C., Popa, M. A., & Aguirre, A. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1214431 · Cited by 14
Metadata
- Authors
- Nakao, Y., Kimura, H., Sakai, Y., & Fujii, T.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2011-06-01
- Volume
- 5
- Issue
- 2
- Pages
- 22212-22212
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2038427820
- Cited by
- 162
- References
- 1
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.