Skin-on-a-chip models: General overview and future perspectives
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Over the last few years, several advances have been made toward the development and production of in vitro human skin models for the analysis and testing of cosmetic and pharmaceutical products. However, these skin models are cultured under static conditions that make them unable to accurately represent normal human physiology. Recent interest has focused on the generation of in vitro 3D vascularized skin models with dynamic perfusion and microfluidic devices known as skin-on-a-chip. These platforms have been widely described in the literature as good candidates for tissue modeling, as they enable a more physiological transport of nutrients and permit a high-throughput and less expensive evaluation of drug candidates in terms of toxicity, efficacy, and delivery. In this Perspective, recent advances in these novel platforms for the generation of human skin models under dynamic conditions for in vitro testing are reported. Advances in vascularized human skin equivalents (HSEs), transferred skin-on-a-chip (introduction of a skin biopsy or a HSE in the chip), and in situ skin-on-a-chip (generation of the skin model directly in the chip) are critically reviewed, and currently used methods for the introduction of skin cells in the microfluidic chips are discussed. An outlook on current applications and future directions in this field of research are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Anatomy and Physiology of the Skin
Kolarsick, P. A. J., Kolarsick, M. A., & Goodwin, C. (2011) · Journal of the Dermatology Nurses' Association · doi:10.1097/jdn.0b013e3182274a98 · Cited by 578
Schmook, F. P., Meingassner, J. G., & Billich, A. (2001) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(00)00665-7 · Cited by 529
Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476
Skin-on-a-chip model simulating inflammation, edema and drug-based treatment
Wufuer, M., Lee, G., Hur, W., Jeon, B., Kim, B. J., Choi, T. H., & Lee, S. (2016) · Scientific Reports · doi:10.1038/srep37471 · Cited by 356
Research works printed but not linked: 68
- 2016, Skin: Structure and function, 1
- 2013, Junqueira's Basic Histology
- 2019, Skin thickness dimensions in histological section measurement during late-fetal and neonatal developmental period: A systematic review, Ski. Res. Technol., 25, 793, 10.1111/srt.12719 · DOI
- 2020, Microfluidic skin-on-a-chip models: Toward biomimetic artificial skin, Small, 16, 1, 10.1002/smll.202002515 · DOI · Paper page
- 2008, Aging alters functionally human dermal papillary fibroblasts but not reticular fibroblasts: A new view of skin morphogenesis and aging, PLoS One, 3, e4066, 10.1371/journal.pone.0004066 · DOI · Paper page
- 2009, Skin Cancer
- 2011, Re-epithelialization of wounds, Endod. Top., 24, 59, 10.1111/etp.12007 · DOI
- 2019, Skin tissue engineering, 59, 10.1016/B978-0-08-102546-8.00003-0 · DOI
- 2015, Andrews' Diseases of the Skin: Clinical Dermatology, 12e
- 2006, Extracellular matrix | basement membranes, 157, 10.1016/B0-12-370879-6/00143-5 · doi:10.1016/b0-12-370879-6/00143-5
- 1989, Extracellular matrix of the skin: 50 years of progress, J. Invest. Dermatol., 92, 61, 10.1111/1523-1747.ep13075039 · DOI
- 1990, Α6Β4 integrin heterodimer is a component of hemidesmosomes, Proc. Natl. Acad. Sci. U. S. A., 87, 8970, 10.1073/pnas.87.22.8970 · DOI · Paper page
- 2016, Thickness of skin and subcutaneous tissue of the free flap donor sites: A histologic study, Microsurgery, 36, 54, 10.1002/micr.30000 · doi:10.1002/micr.30000
- 2018, 3D human skin bioprinting: A view from the bio side, J. 3D Print. Med., 2, 141, 10.2217/3dp-2018-0008 · DOI
- 2003, In Vitro skin equivalent models for toxicity testing, 229
- 2017, Insights on in vitro models for safety and toxicity assessment of cosmetic ingredients, Int. J. Pharm., 519, 178, 10.1016/j.ijpharm.2017.01.024 · DOI
- 2011, Alternatives to animal testing: Current status and future perspectives, Arch. Toxicol., 85, 841, 10.1007/s00204-011-0718-x · DOI
- 2019, Engineered skin tissue equivalents for product evaluation and therapeutic applications, Biotechnol. J., 14, 1900022, 10.1002/biot.201900022 · DOI · Paper page
- 2011, Skin tissue engineering – In vivo and in vitro applications, Adv. Drug Deliv. Rev., 63, 352, 10.1016/j.addr.2011.01.005 · DOI · Paper page
- 2017, Polymer-based hydrogel scaffolds for skin tissue engineering applications: A mini-review, J. Polym. Res., 24, 112, 10.1007/s10965-017-1278-4 · DOI
- 2018, Property characterization of reconstructed human epidermis equivalents, and performance as a skin irritation model, Toxicol. Vitr., 53, 45, 10.1016/j.tiv.2018.07.005 · DOI
- 2011, Three-dimensional skin models as tools for transdermal drug delivery: Challenges and limitations, Expert Opin. Drug Deliv., 8, 705, 10.1517/17425247.2011.568937 · DOI · Paper page
- 2012, Epithelial and stromal developmental patterns in a novel substitute of the human skin generated with fibrin-agarose biomaterials, Cells Tissues Organs, 196, 1, 10.1159/000330682 · DOI
- 2006, Epidermal homeostasis in long-term scaffold-enforced skin equivalents, J. Investig. Dermatol. Symp. Proc., 11, 93, 10.1038/sj.jidsymp.5650015 · DOI
- 2017, Advances in skin regeneration using tissue engineering, Int. J. Mol. Sci., 18, 789, 10.3390/ijms18040789 · DOI · Paper page
- 2019, Non-animal models in dermatological research, ALTEX, 36, 177, 10.14573/altex.1808022 · DOI · Paper page
- 2010, Tissue engineering of skin, Burns, 36, 450, 10.1016/j.burns.2009.08.016 · DOI · Paper page
- 2019, A new dynamic culture device suitable for rat skin culture, Cell Tissue Res., 375, 723, 10.1007/s00441-018-2945-4 · DOI
- 2003, A tissue-engineered endothelialized dermis to study the modulation of angiogenic and angiostatic molecules on capillary-like tube formation in vitro, Br. J. Dermatol., 148, 1094, 10.1046/j.1365-2133.2003.05298.x · DOI · Paper page
- 2005, In vitro evaluation of the angiostatic potential of drugs using an endothelialized tissue-engineered connective tissue, J. Pharmacol. Exp. Ther., 315, 510, 10.1124/jpet.105.089524 · DOI
- 2015, Modelling the metastatic cascade by in vitro microfluidic platforms, Prog. Histochem. Cytochem., 49, 21, 10.1016/j.proghi.2015.01.001 · DOI
- Quantitative evaluation of human umbilical vein and induced pluripotent stem cell-derived endothelial cells as an alternative cell source to skin-specific endothelial cells in engineered skin grafts, Adv. Wound Care., 10.1089/wound.2020.1163 · DOI
- 2016, Human skin constructs with spatially controlled vasculature using primary and iPSC-derived endothelial cells, Adv. Healthcare Mater., 5, 1800, 10.1002/adhm.201500936 · DOI · Paper page
- 2017, Skin integrated with perfusable vascular channels on a chip, Biomaterials, 116, 48, 10.1016/j.biomaterials.2016.11.031 · DOI · Paper page
- 2019, Perfusable and stretchable 3D culture system for skin-equivalent, Biofabrication, 11, 011001, 10.1088/1758-5090/aaed12 · DOI
- 2019, 3D cell printing of perfusable vascularized human skin equivalent composed of epidermis, dermis, and hypodermis for better structural recapitulation of native skin, Adv. Healthcare Mater., 8, 1, 10.1002/adhm.201801019 · DOI · Paper page
- 2014, Microfluidic organs-on-chips, Nat. Biotechnol., 32, 760, 10.1038/nbt.2989 · DOI · Paper page
- 2014, Microfabricated mammalian organ systems and their integration into models of whole animals and humans, Lab Chip, 13, 1201, 10.1039/c3lc41017j · DOI · Paper page
- 2018, Microsensor systems for cell metabolism-from 2D culture to organ-on-chip, Lab Chip, 18, 1274, 10.1039/C7LC00942A · DOI · Paper page
- 2020, Organ-on-a-chip: Recent breakthroughs and future prospects, Biomed. Eng. Online, 19, 1, 10.1186/s12938-020-0752-0 · DOI · Paper page
- 2016, Skin diseases modeling using combined tissue engineering and microfluidic technologies, Adv. Healthcare Mater., 5, 2459, 10.1002/adhm.201600439 · DOI · Paper page
- 2013, Cells, tissues, and organs on chips: Challenges and opportunities for the cancer tumor microenvironment, Integr. Biol. (United Kingdom), 5, 1096, 10.1039/c3ib40076j · DOI · Paper page
- 2013, Microfluidic heart on a chip for higher throughput pharmacological studies, Lab Chip, 13, 3599, 10.1039/c3lc50350j · DOI · Paper page
- 2007, Acoustically detectable cellular-level lung injury induced by fluid mechanical stresses in microfluidic airway systems, Proc. Natl. Acad. Sci. U. S. A., 104, 18886, 10.1073/pnas.0610868104 · DOI · Paper page
- 2012, On chip porous polymer membranes for integration of gastrointestinal tract epithelium with microfluidic ‘body-on-a-chip’ devices, Biomed. Microdev., 14, 895, 10.1007/s10544-012-9669-0 · DOI · Paper page
- 2013, Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment, Integr. Biol. (United Kingdom), 5, 1119, 10.1039/c3ib40049b · DOI · Paper page
- 2010, A microfluidic hepatic coculture platform for cell-based drug metabolism studies, Biochem. Pharmacol., 79, 1036, 10.1016/j.bcp.2009.11.010 · DOI · Paper page
- 2016, A microfluidics-based in vitro model of the gastrointestinal human-microbe interface, Nat. Commun., 7, 11535, 10.1038/ncomms11535 · DOI · Paper page
- 2016, Pumpless microfluidic platform for drug testing on human skin equivalents, Lab Chip, 15, 882, 10.1039/C4LC00999A · DOI · Paper page
- 2015, Microfluidic organ/body-on-a-chip devices at the convergence of biology and microengineering, Sensors (Switzerland), 15, 31142, 10.3390/s151229848 · DOI · Paper page
- 2014, Bone marrow-on-a-chip replicates hematopoietic niche physiology in vitro, Nat. Methods, 11, 663, 10.1038/nmeth.2938 · DOI · Paper page
- 2013, Electrofluidic pressure sensor embedded microfluidic device: A study of endothelial cells under hydrostatic pressure and shear stress combinations, Lab Chip, 13, 1743, 10.1039/c3lc41414k · DOI
- 2018, Current advances in skin-on-a-chip models for drug testing, Microphysiol. Syst., 2, 1, 10.21037/mps.2018.08.01 · DOI · Paper page
- 2019, A microscale, full-thickness, human skin on a chip assay simulating neutrophil responses to skin infection and antibiotic treatments, Lab Chip, 19, 3094, 10.1039/C9LC00399A · DOI · Paper page
- 2018, Skin-on-a-chip: Transepithelial electrical resistance and extracellular acidification measurements through an automated air-liquid interface, Genes (Basel), 9, 114, 10.3390/genes9020114 · DOI · Paper page
- 2013, Skin and hair on-a-chip: In vitro skin models versus ex vivo tissue maintenance with dynamic perfusion, Lab Chip, 13, 3555, 10.1039/c3lc50227a · DOI · Paper page
- 2017, Construction of 3D multicellular microfluidic chip for an in vitro skin model, Biomed. Microdev., 19, 22, 10.1007/s10544-017-0156-5 · DOI
- 2017, Fabrication of a pumpless, microfluidic skin chip from different collagen sources, J. Ind. Eng. Chem., 56, 375, 10.1016/j.jiec.2017.07.034 · DOI
- 2018, Development of 3D skin-equivalent in a pump-less microfluidic chip, J. Ind. Eng. Chem., 60, 355, 10.1016/j.jiec.2017.11.022 · DOI
- 2020, Side-effect test of sorafenib using 3-D skin equivalent based on microfluidic skin-on-a-chip, J. Ind. Eng. Chem., 82, 71, 10.1016/j.jiec.2019.09.044 · DOI · Paper page
- 2020, Testing the effectiveness of curcuma longa leaf extract on a skin equivalent using a pumpless skin-on-a-chip model, Int. J. Mol. Sci., 21, 1, 10.3390/ijms21228475 · DOI
- 2018, Development of wrinkled skin-on-a-chip (WSOC) by cyclic uniaxial stretching, J. Ind. Eng. Chem., 68, 238, 10.1016/j.jiec.2018.07.050 · DOI
- 2008, Characterization of microfluidic human epidermal keratinocyte culture, Cytotechnology, 56, 197, 10.1007/s10616-008-9149-9 · DOI
- 2018, Full-thickness human skin-on-chip with enhanced epidermal morphogenesis and barrier function, Mater Today, 21, 326, 10.1016/j.mattod.2017.11.002 · DOI · Paper page
- 2019, Photolithography-free skin-on-a-chip for parallel permeation assays, Sens. Mater., 31, 107, 10.18494/SAM.2019.2125 · DOI
- 2016, In vitro micro-physiological immune-competent model of the human skin, Lab Chip, 16, 1899, 10.1039/C6LC00229C · DOI · Paper page
- Generation of a simplified three-dimensional skin-on-a-chip model in a micromachined microfluidic platform, J. Vis. Exp., 2021, e62353, 10.3791/62353 · DOI
- 2021, Monolithic digital patterning of polydimethylsiloxane with successive laser pyrolysis, Nat. Mater., 20, 100, 10.1038/s41563-020-0769-6 · DOI
Cited by
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Bento-Lopes, L., Cabaço, L. C., Charneca, J., Neto, M. V., Seabra, M. C., & Barral, D. C. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241411289 · Cited by 114
Replacing Animal Testing with Stem Cell-Organoids : Advantages and Limitations
Park, G., Rim, Y. A., Sohn, Y., Nam, Y., & Ju, J. H. (2024) · Stem Cell Reviews and Reports · doi:10.1007/s12015-024-10723-5 · Cited by 92
Modeling human HSV infection via a vascularized immune-competent skin-on-chip platform
Sun, S., Jin, L., Zheng, Y., & Zhu, J. (2022) · Nature Communications · doi:10.1038/s41467-022-33114-1 · Cited by 78
Ahn, J., Ohk, K., Won, J., Choi, D.-H., Jung, Y. H., Yang, J. H., Jun, Y., Kim, J.-A., Chung, S., & Lee, S.-H. (2023) · Nature Communications · doi:10.1038/s41467-023-37187-4 · Cited by 65
Portugal-Cohen, M., Cohen, D., Kohen, R., & Oron, M. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1215266 · Cited by 24
“The chamber is connected to channels that allow for the flow of nutrients, oxygen, and other factors to capture the complex interactions between the skin and other organs or systems in the body, such as the immune system or the nervous system (Risueño Rojo et al., 2021).”
BackgroundIn Vitro and Ex Vivo Models for Screening Topical Anti-Inflammatory Drugs
Pérez-Salas, J. L., Moreno-Jiménez, M. R., Rocha-Guzmán, N. E., González-Laredo, R. F., Medina-Torres, L., & Gallegos-Infante, J. A. (2023) · Scientia Pharmaceutica · doi:10.3390/scipharm91020020 · Cited by 22
Bioengineered Efficacy Models of Skin Disease: Advances in the Last 10 Years
Stanton, D. N., Ganguli-Indra, G., Indra, A. K., & Karande, P. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14020319 · Cited by 22
Skin models of cutaneous toxicity, transdermal transport and wound repair
Vilela de Sousa, I., Ferreira, M. J. S., Bebiano, L. B., Simões, S., Matos, A. F., Pereira, R. F., & Granja, P. L. (2023) · Burns & Trauma · doi:10.1093/burnst/tkad014 · Cited by 17
Recreating Human Skin In Vitro: Should the Microbiota Be Taken into Account?
Galvan, A., Pellicciari, C., & Calderan, L. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25021165 · Cited by 11
Metadata
- Authors
- Risueño, I., Valencia, L., Jorcano, J. L., & Velasco, D.
- Venue
- APL Bioengineering
- Publisher
- AIP Publishing
- Published
- 2021-07-08
- Volume
- 5
- Issue
- 3
- Pages
- 030901-030901
- ISSN
- 2473-2877 (ISSN-L)
- OpenAlex
- W3181676144
- Cited by
- 137
- References
- 17
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Update notices
- correction (2021-10-14)
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0/ (vor)
- creativecommons.org/licenses/by/4.0/ (tdm)
- Funders
- Porgrama de Actividades de I+D entre Grupos de Investigación de la Comunidad de Madrid (S2018/BAA-4480)
- Cátedra Fundación Ramón Areces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.