Abstract
The unprecedented stability and accuracy of optical atomic clocks extend their role not only in frequency metrology but also in fundamental physics and geodesy. In particular, excellent stability of optical lattice clocks accessing a fractional uncertainty of 10−18 in less than an hour opens a new avenue for chronometric leveling, which resolves a height difference of one cm in a short averaging time. However, for field use of such clocks, there remains a challenge in developing a transportable system that can operate outside the laboratory. In this Perspective, we describe transportable optical lattice clocks and discuss their future applications to chronometric leveling.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The geodetic potential difference between reference points at PTB [59] and at MPQ [60] was computed by the GNSS/geoid approach, which is expected to be more accurate than geometric leveling for large distances, as it is not affected by systematic leveling errors.”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [59]
Citations
Cites
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Colloquium: Femtosecond optical frequency combs
Cundiff, S. T., & Ye, J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.325 · Cited by 1,083
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Self-citationVisible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Self-citationMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Self-citationGeodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Deformation cycles of subduction earthquakes in a viscoelastic Earth
Wang, K., Hu, Y., & He, J. (2012) · Nature · doi:10.1038/nature11032 · Cited by 488
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Monoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Santarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314
8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Geopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245
Self-citationTransportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Superradiance on the millihertz linewidth strontium clock transition
Norcia, M. A., Winchester, M. N., Cline, J. R. K., & Thompson, J. K. (2016) · Science Advances · doi:10.1126/sciadv.1601231 · Cited by 226
GRACE, time-varying gravity, Earth system dynamics and climate change
Wouters, B., Bonin, J. A., Chambers, D. P., Riva, R. E. M., Sasgen, I., & Wahr, J. (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/11/116801 · Cited by 223
Gravitational Redshift Test Using Eccentric Galileo Satellites
Delva, P., Puchades, N., Schönemann, E., Dilssner, F., Courde, C., Bertone, S., Gonzalez, F., Hees, A., Le Poncin-Lafitte, C., Meynadier, F., et al. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.231101 · Cited by 210
Trapping of Neutral Mercury Atoms and Prospects for Optical Lattice Clocks
Hachisu, H., Miyagishi, K., Porsev, S. G., Derevianko, A., Ovsiannikov, V. D., Pal’chikov, V. G., Takamoto, M., & Katori, H. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.053001 · Cited by 182
Self-citationTest of the Gravitational Redshift with Galileo Satellites in an Eccentric Orbit
Herrmann, S., Finke, F., Lülf, M., Kichakova, O., Puetzfeld, D., Knickmann, D., List, M., Rievers, B., Giorgi, G., Günther, C., et al. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.231102 · Cited by 175
Recoil-Free Spectroscopy of Neutral Sr Atoms in the Lamb-Dicke Regime
Ido, T., & Katori, H. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.053001 · Cited by 172
Self-citationBjerhammar, A. (1985) · Bulletin Géodésique · doi:10.1007/bf02520327 · Cited by 165
Frequency comparison of optical lattice clocks beyond the Dick limit
Takamoto, M., Takano, T., & Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.34 · Cited by 154
Self-citationOriglia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the10−17Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.210801 · Cited by 137
Operational Magic Intensity for Sr Optical Lattice Clocks
Ushijima, I., Takamoto, M., & Katori, H. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.263202 · Cited by 111
Self-citationFrequency Ratio ofHg199andSr87Optical Lattice Clocks beyond the SI Limit
Yamanaka, K., Ohmae, N., Ushijima, I., Takamoto, M., & Katori, H. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.230801 · Cited by 104
Self-citationHyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101
Inner-shell clock transition in atomic thulium with a small blackbody radiation shift
Golovizin, A. A., Fedorova, E., Tregubov, D. O., Sukachev, D., Khabarova, K. Y., Sorokin, V., & Kolachevsky, N. (2019) · Nature Communications · doi:10.1038/s41467-019-09706-9 · Cited by 101
Development of a strontium optical lattice clock for the SOC mission on the ISS
Bongs, K., Singh, Y., Smith, L., He, W., Kock, O., Świerad, D., Hughes, J., Schiller, S., Alighanbari, S., Origlia, S., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.009 · Cited by 94
Ohmae, N., Takamoto, M., Takahashi, Y., Kokubun, M., Araki, K., Hinton, A., Ushijima, I., Muramatsu, T., Furumiya, T., Sakai, Y., et al. (2021) · Advanced Quantum Technologies · doi:10.1002/qute.202100015 · Cited by 79
Self-citationStrategies for reducing the light shift in atomic clocks
Katori, H., Ovsiannikov, V. D., Marmo, S. I., & Palchikov, V. G. (2015) · Physical Review A · doi:10.1103/physreva.91.052503 · Cited by 74
Self-citationDetermination of the5d6s3D1state lifetime and blackbody-radiation clock shift in Yb
Beloy, K., Sherman, J. A., Lemke, N. D., Hinkley, N., Oates, C. W., & Ludlow, A. D. (2012) · Physical Review A · doi:10.1103/physreva.86.051404 · Cited by 69
Narrow-line Cooling and Determination of the Magic Wavelength of Cd
Yamaguchi, A., Safronova, M. S., Gibble, K., & Katori, H. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.113201 · Cited by 65
Self-citationKulosa, A. P., Fim, D., Zipfel, K. H., Rühmann, S., Sauer, S., Jha, N., Gibble, K., Ertmer, W., Rasel, E. M., Safronova, M. S., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.240801 · Cited by 64
Compact, thermal-noise-limited reference cavity for ultra-low-noise microwave generation
Davila-Rodriguez, J., Baynes, F. N., Ludlow, A. D., Fortier, T. M., Leopardi, H., Diddams, S. A., & Quinlan, F. (2017) · Optics Letters · doi:10.1364/ol.42.001277 · Cited by 57
Ground-based optical atomic clocks as a tool to monitor vertical surface motion
Bondarescu, R., Schärer, A., Lundgren, A., Hetényi, G., Houlié, N., Jetzer, P., & Bondarescu, M. (2015) · Geophysical Journal International · doi:10.1093/gji/ggv246 · Cited by 56
Optical frequency distribution using laser repeater stations with planar lightwave circuits
Akatsuka, T., Goh, T., Imai, H., Oguri, K., Ishizawa, A., Ushijima, I., Ohmae, N., Takamoto, M., Katori, H., Hashimoto, T., et al. (2020) · Optics Express · doi:10.1364/oe.383526 · Cited by 55
Self-citationVallet, G., Bookjans, E., Eismann, U., Bilicki, S., Targat, R. L., & Lodewyck, J. (2017) · New Journal of Physics · doi:10.1088/1367-2630/aa7c84 · Cited by 51
Voigt, C., Denker, H., & Timmen, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1365 · Cited by 50
Phase Locking a Clock Oscillator to a Coherent Atomic Ensemble
Kohlhaas, R., Bertoldi, A., Cantin, E., Aspect, A., Landragin, A., & Bouyer, P. (2015) · Physical Review X · doi:10.1103/physrevx.5.021011 · Cited by 47
The unit of time: Present and future directions
Bize, S. (2019) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2019.02.002 · Cited by 47
Transportable interrogation laser system with an instability of mod σy = 3 × 10−16
Häfner, S., Herbers, S., Vogt, S., Lisdat, C., & Sterr, U. (2020) · Optics Express · doi:10.1364/oe.390105 · Cited by 37
Blackbody radiation shift in strontium lattice clocks revisited
Lisdat, C., Dörscher, S., Nosske, I., & Sterr, U. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.l042036 · Cited by 36
Frequency Standards and Metrology
(2002) · doi:10.1142/4927 · Cited by 32
Stadnik, Y. V. (2020) · Physical Review D · doi:10.1103/physrevd.102.115016 · Cited by 31
Longitudinal Ramsey spectroscopy of atoms for continuous operation of optical clocks
Katori, H. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac0e16 · Cited by 31
Self-citationExploring potential applications of optical lattice clocks in a plate subduction zone
Tanaka, Y., & Katori, H. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01548-y · Cited by 31
Self-citationHigher-order effects on the precision of clocks of neutral atoms in optical lattices
Ovsiannikov, V. D., Marmo, S. I., Pal'chikov, V. G., & Katori, H. (2016) · Physical Review A · doi:10.1103/physreva.93.043420 · Cited by 28
Self-citationCavity-enhanced non-destructive detection of atoms for an optical lattice clock
Hobson, R., Bowden, W., Vianello, A., Hill, I. R., & Gill, P. (2019) · Optics Express · doi:10.1364/oe.27.037099 · Cited by 25
McFerran, J. J., Yi, L., Mejri, S., Zhang, W., Manno, S. D., Abgrall, M., Guéna, J., Coq, Y. L., & Bize, S. (2014) · Physical Review A · doi:10.1103/physreva.89.043432 · Cited by 16
Research works printed but not linked: 3
- 2006, Physical Geodesy
- 2019, Chronometric Geodesy: Methods and Applications, Relativistic Geodesy, Foundations and Applications
- 2013, Atmospheric Effects in Space Geodesy
Cited by
Long-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
“4, we achieve a height resolution below 30 cm and a corresponding fractional frequency resolution of 3 × 10 − 17 within one hour of measurement, and 6 cm within one day.”
Xiong, C., Liu, D., Wu, L., Bao, L., & Zhang, P. (2022) · Remote Sensing · doi:10.3390/rs14174141 · Cited by 3
Metadata
- Authors
- Takamoto, M., Tanaka, Y., & Katori, H.
- Affiliations
- RIKEN (JP)
- The University of Tokyo (JP)
- Corresponding author
- Katori, H.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2022-04-04
- Volume
- 120
- Issue
- 14
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W4225746206
- Cited by
- 40
- References
- 60
- Citations by year
- 2026: 3 · 2025: 13 · 2024: 11 · 2023: 11 · 2022: 2
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Funders
- JST-Mirai Program (JPMJMI18A1)
- Japan Society for the Promotion of Science (JP16H06284)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- optical lattice clock, frequency metrology, geodesy, height difference measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.