The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Single-molecule high-resolution imaging with photobleaching
Open accessAbstract
Conventional light microscopy is limited in its resolving power by the Rayleigh limit to length scales on the order of 200 nm. On the other hand, spectroscopic techniques such as fluorescence resonance energy transfer cannot be used to measure distances >10 nm, leaving a “gap” in the ability of optical techniques to measure distances on the 10- to 100-nm scale. We have previously demonstrated the ability to localize single dye molecules to a precision of 1.5 nm with subsecond time resolution. Here we locate the position of two dyes and determine their separation with 5-nm precision, using the quantal photobleaching behavior of single fluorescent dye molecules. By fitting images both before and after photobleaching of one of the dyes, we may localize both dyes simultaneously and compute their separation. Hence, we have circumvented the Rayleigh limit and achieved nanometer-scale resolution. Specifically, we demonstrate the technique by measuring the distance between single fluorophores separated by 10–20 nm via attachment to the ends of double-stranded DNA molecules immobilized on a surface. In addition to bridging the gap in optical resolution, this technique may be useful for biophysical or genomic applications, including the generation of super-high-density maps of single-nucleotide polymorphisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Entropic Elasticity of λ-Phage DNA
Bustamante, C., Marko, J. F., Siggia, E. D., & Smith, S. (1994) · Science · doi:10.1126/science.8079175 · Cited by 2,154
Fluorescence Spectroscopy of Single Biomolecules
Weiss, S. (1999) · Science · doi:10.1126/science.283.5408.1676 · Cited by 2,046
Energy transfer: a spectroscopic ruler.
Stryer, L., & Haugland, R. P. (1967) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.58.2.719 · Cited by 1,957
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization
Yildiz, A., Forkey, J. N., McKinney, S. A., Ha, T., Goldman, Y. E., & Selvin, P. R. (2003) · Science · doi:10.1126/science.1084398 · Cited by 1,837
Self-citationFunatsu, T., Harada, Y., Tokunaga, M., Saito, K., & Yanagida, T. (1995) · Nature · doi:10.1038/374555a0 · Cited by 1,047
The renaissance of fluorescence resonance energy transfer.
Selvin, P. R. (2000) · Nature Structural Biology · doi:10.1038/78948 · Cited by 1,018
Self-citationYildiz, A., Tomishige, M., Vale, R. D., & Selvin, P. R. (2004) · Science · doi:10.1126/science.1093753 · Cited by 965
Self-citationImaging of single molecule diffusion.
Schmidt, T., Schütz, G. J., Baumgartner, W., Gruber, H. J., & Schindler, H. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.7.2926 · Cited by 613
Asphaltene Molecular Size and Structure
Groenzin, H., & Mullins, O. C. (1999) · The Journal of Physical Chemistry A · doi:10.1021/jp992609w · Cited by 537
Proposed method for molecular optical imaging
Betzig, E. (1995) · Optics Letters · doi:10.1364/ol.20.000237 · Cited by 444
Kao, H. P., & Verkman, A. S. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80601-0 · Cited by 420
Focal Spots of Size λ / 23 Open Up Far-Field Florescence Microscopy at 33 nm Axial Resolution
Dyba, M., & Hell, S. W. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.163901 · Cited by 364
Ultrahigh-resolution multicolor colocalization of single fluorescent probes
Lacoste, T. D., Michalet, X., Pinaud, F., Chemla, D. S., Alivisatos, A. P., & Weiss, S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170286097 · Cited by 285
Automated high resolution optical mapping using arrayed, fluid-fixed DNA molecules
Jing, J., Reed, J., Huang, J., Hu, X., Clarke, V., Edington, J., Housman, D., Anantharaman, T. S., Huff, E. J., Mishra, B., et al. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.14.8046 · Cited by 277
Imaging and Tracking of Single GFP Molecules in Solution
Kubitscheck, U., Kückmann, O., Kues, T., & Peters, R. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76764-6 · Cited by 244
Imaging Three-Dimensional Single Molecule Orientations
Bartko, A. P., & Dickson, R. M. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp993364q · Cited by 225
Hindered Rotational Diffusion and Rotational Jumps of Single Molecules
Ha, T., Glass, J., Enderle, T., Chemla, D. S., & Weiss, S. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.2093 · Cited by 177
Self-citationThose Blinking Single Molecules
Moerner, W. E. (1997) · Science · doi:10.1126/science.277.5329.1059 · Cited by 107
Far-field fluorescence microscopy beyond the diffraction limit
van Oijen, A. M., Köhler, J. R., Schmidt, J., Mueller, M., & Brakenhoff, G. J. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.000909 · Cited by 96
RNA Conformation and Folding Studied with Fluorescence Resonance Energy Transfer
Klostermeier, D., & Millar, D. P. (2001) · Methods · doi:10.1006/meth.2000.1135 · Cited by 66
Interhead Distance Measurements in Myosin VI via SHRImP Support a Simplified Hand-Over-Hand Model
Balci, H., Ha, T., Sweeney, H. L., et al. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.060608 · Cited by 46
Self-citation
Cited by
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
Breaking the Diffraction Barrier: Super-Resolution Imaging of Cells
Huang, B., Babcock, H., & Zhuang, X. (2010) · Cell · doi:10.1016/j.cell.2010.12.002 · Cited by 1,156
Metadata
- Authors
- Gordon, M. P., Ha, T., & Selvin, P. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-04-19
- Volume
- 101
- Issue
- 17
- Pages
- 6462-6465
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2070142943
- Cited by
- 372
- References
- 22
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.