The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Diagnosing breast cancer by using Raman spectroscopy
Open accessAbstract
We employ Raman spectroscopy to diagnose benign and malignant lesions in human breast tissue based on chemical composition. In this study, 130 Raman spectra are acquired from ex vivo samples of human breast tissue (normal, fibrocystic change, fibroadenoma, and infiltrating carcinoma) from 58 patients. Data are fit by using a linear combination model in which nine basis spectra represent the morphologic and chemical features of breast tissue. The resulting fit coefficients provide insight into the chemical/morphological makeup of the tissue and are used to develop diagnostic algorithms. The fit coefficients for fat and collagen are the key parameters in the resulting diagnostic algorithm, which classifies samples according to their specific pathological diagnoses, attaining 94% sensitivity and 96% specificity for distinguishing cancerous tissues from normal and benign tissues. The excellent results demonstrate that Raman spectroscopy has the potential to be applied in vivo to accurately classify breast lesions, thereby reducing the number of excisional breast biopsies that are performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELSTON, C. W., & ELLIS, I. O. (1991) · Histopathology · doi:10.1111/j.1365-2559.1991.tb00229.x · Cited by 6,175
Firminger, H. I. (1968) · Armed Forces Institute of Pathology eBooks · Cited by 3,044
A New Type of Secondary Radiation
RAMAN, C. V., & KRISHNAN, K. S. (1928) · Nature · doi:10.1038/121501c0 · Cited by 2,647
Robbins pathologic basis of disease
Cotran, R. S., Kumar, V., & Collins, T. (1989) · Medical Entomology and Zoology · Cited by 1,944
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Self-citationConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Curtiss, J. H., & Kenney, J. F. (1940) · American Mathematical Monthly · doi:10.2307/2302695 · Cited by 487
Raman Spectroscopy of Normal and Diseased Human Breast Tissues
Frank, C. J., McCreery, R. L., & Redd, D. C. B. (1995) · Analytical Chemistry · doi:10.1021/ac00101a001 · Cited by 400
Applied Multivariate Techniques
Marcucci, M. (1997) · Technometrics · doi:10.1080/00401706.1997.10485444 · Cited by 376
Haka, A. S., Shafer‐Peltier, K., Fitzmaurice, M., Crowe, J. P., Dasari, R. R., & Feld, M. S. (2002) · PubMed · Cited by 302
Self-citation
Cited by
Huang, X., & El-Sayed, M. A. (2010) · Journal of Advanced Research · doi:10.1016/j.jare.2010.02.002 · Cited by 2,192
Gold Nanorods: From Synthesis and Properties to Biological and Biomedical Applications
Huang, X., Neretina, S., & El‐Sayed, M. A. (2009) · Advanced Materials · doi:10.1002/adma.200802789 · Cited by 1,921
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
Raman Techniques: Fundamentals and Frontiers
Jones, R. R., Hooper, D. C., Zhang, L., Wolverson, D., & Valev, V. K. (2019) · Nanoscale Research Letters · doi:10.1186/s11671-019-3039-2 · Cited by 804
Raman Spectroscopy of Biological Tissues
Talari, A. C. S., Movasaghi, Z., Rehman, S., & Rehman, I. U. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.923902 · Cited by 739
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Kong, K., Kendall, C., Stone, N., & Notingher, I. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.009 · Cited by 653
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Noninvasive molecular imaging of small living subjects using Raman spectroscopy
Keren, S., Zavaleta, C., Cheng, Z., de la Zerda, A., Gheysens, O., & Gambhir, S. S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710575105 · Cited by 604
Chemically sensitive bioimaging with coherent Raman scattering
Camp Jr, C. H., & Cicerone, M. T. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.60 · Cited by 472
High-speed coherent Raman fingerprint imaging of biological tissues
Camp Jr, C. H., Lee, Y. J., Heddleston, J. M., Hartshorn, C. M., Walker, A. R. H., Rich, J. N., Lathia, J. D., & Cicerone, M. T. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.145 · Cited by 469
In vivo Margin Assessment during Partial Mastectomy Breast Surgery Using Raman Spectroscopy
Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Lyons, J., Hicks, D., Fitzmaurice, M., Dasari, R. R., Crowe, J. P., & Feld, M. S. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-2815 · Cited by 424
Self-citationMetabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Applications of Raman spectroscopy in cancer diagnosis
Auner, G. W., Koya, S. K., Huang, C., Broadbent, B., Trexler, M., Auner, Z., Elias, A., Mehne, K. C., & Brusatori, M. A. (2018) · Cancer and Metastasis Reviews · doi:10.1007/s10555-018-9770-9 · Cited by 385
Using single-vesicle technologies to unravel the heterogeneity of extracellular vesicles
Bordanaba-Florit, G., Royo, F., Kruglik, S. G., & Falcón-Pérez, J. M. (2021) · Nature Protocols · doi:10.1038/s41596-021-00551-z · Cited by 325
Smith, Z. J., Lee, C., Rojalin, T., Carney, R. P., Hazari, S., Knudson, A., Lam, K., Saari, H., Ibañez, E. L., Viitala, T., et al. (2015) · Journal of Extracellular Vesicles · doi:10.3402/jev.v4.28533 · Cited by 321
Vibrational spectroscopy: a clinical tool for cancer diagnostics
Kendall, C., Isabelle, M., Bazant-Hegemark, F., Hutchings, J., Orr, L., Babrah, J., Baker, R., & Stone, N. (2009) · The Analyst · doi:10.1039/b822130h · Cited by 293
Raman and CARS microspectroscopy of cells and tissues
Krafft, C., Dietzek, B., & Popp, J. (2009) · The Analyst · doi:10.1039/b822354h · Cited by 271
Tissue refractive index as marker of disease
Wang, Z., Popescu, G., Tangella, K. V., & Balla, A. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3656732 · Cited by 271
Zavaleta, C., de la Zerda, A., Liu, Z., Keren, S., Cheng, Z., Schipper, M., Chen, X., Dai, H., & Gambhir, S. S. (2008) · Nano Letters · doi:10.1021/nl801362a · Cited by 268
Nachabe, R., Hendriks, B. H., Lucassen, G. W., van der Voort, M., Evers, D. J., Rutgers, E. J., Peeters, M.-J. V., Van der Hage, J. A., Oldenburg, H. S., Ruers, T. J., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3611010 · Cited by 161
Full range characterization of the Raman spectra of organs in a murine model
Huang, N., Short, M., Zhao, J., Wang, H., Lui, H., Korbelik, M., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.022892 · Cited by 131
Li, X., Zhou, R., Xu, Y., Wei, X., & He, Y. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1226183 · Cited by 13
Metadata
- Authors
- Haka, A. S., Shafer-Peltier, K. E., Fitzmaurice, M., Crowe, J., Dasari, R. R., & Feld, M. S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-08-22
- Volume
- 102
- Issue
- 35
- Pages
- 12371-12376
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2039897852
- Cited by
- 630
- References
- 22
- FWCI
- 12.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.