Three-dimensional cellular microarray for high-throughput toxicology assays
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
We have developed a miniaturized 3D cell-culture array (the Data Analysis Toxicology Assay Chip or DataChip) for high-throughput toxicity screening of drug candidates and their cytochrome P450-generated metabolites. The DataChip consists of human cells encapsulated in collagen or alginate gels (as small as 20 nl) arrayed on a functionalized glass slide for spatially addressable screening against multiple compounds. A single DataChip containing 1,080 individual cell cultures, used in conjunction with the complementary human P450-containing microarray (the Metabolizing Enzyme Toxicology Assay Chip or MetaChip), simultaneously provided IC 50 values for nine compounds and their metabolites from CYP1A2, CYP2D6, and CYP3A4 and a mixture of the three P450s designed to emulate the human liver. Similar responses were obtained with the DataChip and conventional 96-well plate assays, demonstrating that the near 2,000-fold miniaturization does not influence the cytotoxicity response. The DataChip may therefore enable toxicity analyses of drug candidates and their metabolites at throughputs compatible with the availability of compounds at early-stage drug discovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ADMET in silico modelling: towards prediction paradise?
van de Waterbeemd, H., & Gifford, E. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1032 · Cited by 1,863
Common and Uncommon Cytochrome P450 Reactions Related to Metabolism and Chemical Toxicity
Guengerich, F. P. (2001) · Chemical Research in Toxicology · doi:10.1021/tx0002583 · Cited by 1,655
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
Dobson, C. M. (2004) · Nature · doi:10.1038/nature03192 · Cited by 1,003
Diversity-oriented synthesis: Exploring the intersections between chemistry and biology
Tan, D. S. (2005) · Nature Chemical Biology · doi:10.1038/nchembio0705-74 · Cited by 605
Acetaminophen activation by human liver cytochromes P450IIE1 and P450IA2
Raucy, J. L., Lasker, J. M., Lieber, C. S., & Black, M. (1989) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(89)90278-6 · Cited by 478
HER2/PI-3K/Akt activation leads to a multidrug resistance in human breast adenocarcinoma cells
Knuefermann, C., Lu, Y., Liu, B., Jin, W., Liang, K., Wu, L., Schmidt, M., Mills, G. B., Mendelsohn, J., & Fan, Z. (2003) · Oncogene · doi:10.1038/sj.onc.1206394 · Cited by 452
Natural products — The future scaffolds for novel antibiotics?
Butler, M. S., & Buss, A. D. (2006) · Biochemical Pharmacology · doi:10.1016/j.bcp.2005.10.012 · Cited by 337
The Role of Absorption, Distribution, Metabolism, Excretion and Toxicity in Drug Discovery
Lin, J., Sahakian, D., de Morais, S., Xu, J., Polzer, R., & Winter, S. (2003) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026033452096 · Cited by 327
Inhibition of Cytochromes P450 by Antifungal Imidazole Derivatives
Zhang, W., Ramamoorthy, Y., Kilicarslan, T., Nolte, H., Tyndale, R. F., & Sellers, E. M. (2002) · Drug Metabolism and Disposition · doi:10.1124/dmd.30.3.314 · Cited by 249
Cited by
Designing materials to direct stem-cell fate
Lutolf, M. P., Gilbert, P. M., & Blau, H. M. (2009) · Nature · doi:10.1038/nature08602 · Cited by 1,393
Mannoor, M. S., Jiang, Z., James, T., Kong, Y. L., Malatesta, K. A., Soboyejo, W. O., Verma, N., Gracias, D. H., & McAlpine, M. C. (2013) · Nano Letters · doi:10.1021/nl4007744 · Cited by 874
Laser assisted bioprinting of engineered tissue with high cell density and microscale organization
Guillotin, B., Souquet, A., Catros, S., Duocastella, M., Pippenger, B., Bellance, S., Bareille, R., Rémy, M., Bordenave, L., Amédée, J., et al. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.055 · Cited by 832
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
Three-dimensional in vitro tumor models for cancer research and drug evaluation
Xu, X., Farach-Carson, M. C., & Jia, X. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.07.009 · Cited by 461
Alessandri, K., Sarangi, B. R., Gurchenkov, V. V., Sinha, B., Kießling, T. R., Fetler, L., Rico, F., Scheuring, S., Lamaze, C., Simon, A., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1309482110 · Cited by 460
Adaptation of High-Throughput Screening in Drug Discovery—Toxicological Screening Tests
Szymański, P., Markowicz, M., & Mikiciuk-Olasik, E. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms13010427 · Cited by 454
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Sung, J. H., & Shuler, M. L. (2009) · Lab on a Chip · doi:10.1039/b901377f · Cited by 431
Weigelt, B., Ghajar, C. M., & Bissell, M. J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.01.001 · Cited by 335
Cell and tissue engineering for liver disease
Bhatia, S. N., Underhill, G. H., Zaret, K. S., & Fox, I. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3005975 · Cited by 309
Fernandes, T. G., Diogo, M. M., Clark, D. S., Dordick, J. S., & Cabral, J. M. S. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.02.009 · Cited by 285
Self-citationMicrofluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
“Lee et al. [66] developed a miniaturized 3D cell-culture array (called DataChip) for high-throughput toxicity screening of drug candidates, illustrated in Fig.”
Cell viability assessment using the Alamar blue assay: A comparison of 2D and 3D cell culture models
Bonnier, F., Keating, M. E., Wróbel, T. P., Majzner, K., Baranska, M., Garcia-Munoz, A., Blanco, A., & Byrne, H. J. (2015) · Toxicology in Vitro · doi:10.1016/j.tiv.2014.09.014 · Cited by 276
Modelling tissues in 3D: the next future of pharmaco-toxicology and food research?
Mazzoleni, G., Di Lorenzo, D., & Steimberg, N. (2009) · Genes & Nutrition · doi:10.1007/s12263-008-0107-0 · Cited by 253
Cellular Chemosensitivity Assays: An Overview
Sumantran, V. N. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-61779-080-5_19 · Cited by 166
Lee, J. B., & Sung, J. H. (2013) · Biotechnology Journal · doi:10.1002/biot.201300086 · Cited by 92
“Metabolites were formed by the reaction of a drug with P450 enzyme, which were subsequently incubated with target cells to test cytotoxicity [48].”
MethodControlled 3D culture in Matrigel microbeads to analyze clonal acinar development
Dolega, M. E., Abeille, F., Picollet-D'hahan, N., & Gidrol, X. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.042 · Cited by 91
Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces
Ben-Yoav, H., Melamed, S., Freeman, A., Shacham-Diamand, Y., & Belkin, S. (2011) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2010.532767 · Cited by 52
A study of electrochemical biosensor for analysis of three-dimensional (3D) cell culture
Jeong, S. H., Lee, D. W., Kim, S., Kim, J., & Ku, B. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.02.039 · Cited by 33
“And more importantly, this result explains that 3D culturing increased drug resistance (Tung et al., 2011; Lee et al., 2008b; dit Faute et al., 2002).”
BackgroundAdvances in cell‐based biosensors using three‐dimensional cell‐encapsulating hydrogels
Zhou, L., Huang, G., Wang, S., Wu, J., Lee, W. G., Chen, Y., Xu, F., & Lu, T. (2011) · Biotechnology Journal · doi:10.1002/biot.201100098 · Cited by 17
High-throughput transfection of interfering RNA into a 3D cell-culture chip
Zhang, H., Lee, M., Hogg, M. G., Dordick, J. S., & Sharfstein, S. T. (2012) · Small · doi:10.1002/smll.201102205 · Cited by 16
Self-citationDrug susceptibility of matrix‐encapsulated Candida albicans nano‐biofilms
Srinivasan, A., Gupta, C. M., Agrawal, C. M., Leung, K. P., Lopez‐Ribot, J. L., & Ramasubramanian, A. K. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25120 · Cited by 11
“To this cell suspension,1.8 mg/mL collagen or 1.5% (w/v in water) alginate was added, and 50 nL of this solution was printed by noncontact deposition using a robotic microarrayer (Microsys, Digilab Inc., Marlborough, MA) on to PS-MA-modified glass slides (Lee et al. 2008; Srinivasan et al. 2012).”
BackgroundMethodInfluential
Metadata
- Authors
- Lee, M.-Y., Kumar, R. A., Sukumaran, S. M., Hogg, M. G., Clark, D. S., & Dordick, J. S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-01-08
- Volume
- 105
- Issue
- 1
- Pages
- 59-63
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2090124541
- Cited by
- 314
- References
- 31
- FWCI
- 10.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.