Isolation of circulating tumor cells using a microvortex-generating herringbone-chip
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Rare circulating tumor cells (CTCs) present in the bloodstream of patients with cancer provide a potentially accessible source for detection, characterization, and monitoring of nonhematological cancers. We previously demonstrated the effectiveness of a microfluidic device, the CTC-Chip, in capturing these epithelial cell adhesion molecule (EpCAM)-expressing cells using antibody-coated microposts. Here, we describe a high-throughput microfluidic mixing device, the herringbone-chip, or “HB-Chip,” which provides an enhanced platform for CTC isolation. The HB-Chip design applies passive mixing of blood cells through the generation of microvortices to significantly increase the number of interactions between target CTCs and the antibody-coated chip surface. Efficient cell capture was validated using defined numbers of cancer cells spiked into control blood, and clinical utility was demonstrated in specimens from patients with prostate cancer. CTCs were detected in 14 of 15 (93%) patients with metastatic disease (median = 63 CTCs/mL, mean = 386 ± 238 CTCs/mL), and the tumor-specific TMPRSS2-ERG translocation was readily identified following RNA isolation and RT-PCR analysis. The use of transparent materials allowed for imaging of the captured CTCs using standard clinical histopathological stains, in addition to immunofluorescence-conjugated antibodies. In a subset of patient samples, the low shear design of the HB-Chip revealed microclusters of CTCs, previously unappreciated tumor cell aggregates that may contribute to the hematogenous dissemination of cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Self-citationChaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
de Bono, J. S., Scher, H. I., Montgomery, R. B., Parker, C., Miller, M. C., Tissing, H., Doyle, G. V., Terstappen, L. W. W. M., Pienta, K. J., & Raghavan, D. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-0872 · Cited by 2,182
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Self-citationIsolation by Size of Epithelial Tumor Cells
Vona, G., Sabile, A., Louha, M., Sitruk, V., Romana, S., Schütze, K., Capron, F., Franco, D., Pazzagli, M., Vekemans, M., et al. (2000) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64706-2 · Cited by 1,069
Chiang, A. C., & Massagué, J. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0805239 · Cited by 1,054
Al-Mehdi, A. B., Tozawa, K., Fisher, A. B., Shientag, L., Lee, A., & Muschel, R. J. (2000) · Nature Medicine · doi:10.1038/71429 · Cited by 706
Circulating Tumor Cell Number and Prognosis in Progressive Castration-Resistant Prostate Cancer
Danila, D. C., Heller, G., Gignac, G. A., Gonzalez-Espinoza, R., Anand, A., Tanaka, E., Lilja, H., Schwartz, L., Larson, S., Fleisher, M., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-1506 · Cited by 665
Scher, H. I., Jia, X., de Bono, J. S., Fleisher, M., Pienta, K. J., Raghavan, D., & Heller, G. (2009) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70340-1 · Cited by 611
Cited by
Items 101–178 of 178
Microfluidics and Circulating Tumor Cells
Dong, Y., Skelley, A. M., Merdek, K. D., Sprott, K. M., Jiang, C., Pierceall, W. E., Lin, J., Stocum, M., Carney, W. P., & Smirnov, D. A. (2013) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2012.09.004 · Cited by 219
Circulating Tumor Cell Isolation and Diagnostics: Toward Routine Clinical Use
van de Stolpe, A., Pantel, K., Sleijfer, S., Terstappen, L. W., & den Toonder, J. M. J. (2011) · Cancer Research · doi:10.1158/0008-5472.can-11-1254 · Cited by 218
“channels (25) coated with EpCAM antibodies, generating flow patterns to optimize cell antibody contact while preserving cell viability.”
Circulating tumor cell clusters: What we know and what we expect (Review)
Hong, Y., Fang, F., & Zhang, Q. (2016) · International Journal of Oncology · doi:10.3892/ijo.2016.3747 · Cited by 218
A Novel Platform for Detection of CK+ and CK− CTCs
Pecot, C. V., Bischoff, F. Z., Mayer, J. A., Wong, K. L., Pham, T., Bottsford-Miller, J., Stone, R. L., Lin, Y. G., Jaladurgam, P., Roh, J. W., et al. (2011) · Cancer Discovery · doi:10.1158/2159-8290.cd-11-0215 · Cited by 217
Lee, M. G., Shin, J. H., Bae, C. Y., Choi, S., & Park, J.-K. (2013) · Analytical Chemistry · doi:10.1021/ac4006149 · Cited by 216
Grover, P. K., Cummins, A. G., Price, T. J., Roberts-Thomson, I. C., & Hardingham, J. E. (2014) · Annals of Oncology · doi:10.1093/annonc/mdu018 · Cited by 214
“technologies [18–24].”
BackgroundMicrofluidics for Manipulating Cells
Mu, X., Zheng, W., Sun, J., Zhang, W., & Jiang, X. (2013) · Small · doi:10.1002/smll.201200996 · Cited by 214
Huang, S.-B., Wu, M.-H., Lin, Y.-H., Hsieh, C.-H., Yang, C.-L., Lin, H.-C., Tseng, C.-P., & Lee, G.-B. (2013) · Lab on a Chip · doi:10.1039/c3lc41256c · Cited by 213
Scher, H. I., Morris, M. J., Basch, E., & Heller, G. (2011) · Journal of Clinical Oncology · doi:10.1200/jco.2011.35.8648 · Cited by 213
Kirby, B. J., Jodari, M., Loftus, M. S., Gakhar, G., Pratt, E. D., Chanel-Vos, C., Gleghorn, J. P., Santana, S. M., Liu, H., Smith, J. P., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035976 · Cited by 212
“Other microdevices have also reported increased sensitivity and detection levels in microfluidic geometries with anti-EpCAM capture relative to CellSearchH [7–9], so these data alone do not indicate that anti-PSMA capture leads to higher cell counts than anti-EpCAM capture.”
BackgroundMethodHou, S., Zhao, L., Shen, Q., Yu, J., Ng, C., Kong, X., Wu, D., Song, M., Shi, X., Xu, X., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201208452 · Cited by 211
Pallaoro, A., Hoonejani, M. R., Braun, G. B., Meinhart, C. D., & Moskovits, M. (2015) · ACS Nano · doi:10.1021/acsnano.5b00750 · Cited by 209
A rapid and label-free platform for virus capture and identification from clinical samples
Yeh, Y.-T., Gulino, K., Zhang, Y., Sabestien, A., Chou, T.-W., Zhou, B., Lin, Z., Albert, I., Lu, H., Swaminathan, V., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1910113117 · Cited by 209
“Previous studies have shown that herringbone patterns, made of PDMS (polydimethylsiloxane), enhance mixing of the samples inside a microfluidic channel by inducing a chaotic flow (29, 30).”
Zhang, P., Chen, L., Xu, T., Liu, H., Liu, X., Meng, J., Yang, G., Jiang, L., & Wang, S. (2013) · Advanced Materials · doi:10.1002/adma.201300888 · Cited by 209
Expansion of CTCs from early stage lung cancer patients using a microfluidic co-culture model
Zhang, Z., Shiratsuchi, H., Lin, J., Chen, G., Reddy, R. M., Azizi, E., Fouladdel, S., Chang, A. C., Lin, L., Jiang, H., et al. (2014) · Oncotarget · doi:10.18632/oncotarget.2592 · Cited by 207
Self-citationCirculating Tumor Cells: A Multifunctional Biomarker
Yap, T. A., Lorente, D., Omlin, A., Olmos, D., & de Bono, J. S. (2014) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-13-2664 · Cited by 206
“HerringboneChip Daniel Haber and Mehmet Toner, Dana-Farber and MGH Microvortices are used to significantly increase the number of interactions between target CTCs and the antibody-coated chip surface (15)”
Khoo, B. L., Warkiani, M. E., Tan, D. S.-W., Bhagat, A. A. S., Irwin, D., Lau, D. P., Lim, A. S. T., Lim, K. H., Krisna, S. S., Lim, W.-T., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099409 · Cited by 206
“Also, a negligible amount of double positive CK+/CD45+cells (,5%, data not reported) were detected in our enriched samples, as was similarly reported elsewhere [21].”
ResultYoon No, D., Lee, K.-H., Lee, J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c5lc00611b · Cited by 205
Do Circulating Tumor Cells, Exosomes, and Circulating Tumor Nucleic Acids Have Clinical Utility?
Gold, B., Cankovic, M., Furtado, L. V., Meier, F., & Gocke, C. D. (2015) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2015.02.001 · Cited by 205
Resistance to Fluid Shear Stress Is a Conserved Biophysical Property of Malignant Cells
Barnes, J. M., Nauseef, J. T., & Henry, M. D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050973 · Cited by 203
Nima, Z. A., Mahmood, M., Xu, Y., Mustafa, T., Watanabe, F., Nedosekin, D. A., Juratli, M. A., Fahmi, T., Galanzha, E. I., Nolan, J. P., et al. (2014) · Scientific Reports · doi:10.1038/srep04752 · Cited by 200
Chen, K., & Hugh Fan, Z. (2016) · Circulating Tumor Cells · doi:10.1002/9781119244554.ch2 · Cited by 200
Advanced liquid biopsy technologies for circulating biomarker detection
Soda, N., Rehm, B. H. A., Sonar, P., Nguyen, N.-T., & Shiddiky, M. J. A. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb01490j · Cited by 198
Characterization of circulating tumor cell aggregates identified in patients with epithelial tumors
Cho, E. H., Wendel, M., Luttgen, M., Yoshioka, C., Marrinucci, D., Lazar, D., Schram, E., Nieva, J., Bazhenova, L., Morgan, A., et al. (2012) · Physical Biology · doi:10.1088/1478-3975/9/1/016001 · Cited by 198
“Occasional CTC aggregation has been observed by others using alternative methods [6]; however, this is the first time a significant number of CTC aggregates have been reported.”
MethodA Review of Circulating Tumour Cell Enrichment Technologies
Rushton, A. J., Nteliopoulos, G., Shaw, J. A., & Coombes, R. C. (2021) · Cancers · doi:10.3390/cancers13050970 · Cited by 197
“The LPCTC-iChip may be of significant importance since the chip has been designed to efficiently process leukapheresis products where CTC numbers are ultimately greater due to the much larger volume of blood sampled.”
BackgroundMethodInfluentialDetection of circulating tumor cells: opportunities and challenges
Ju, S., Chen, C., Zhang, J., Xu, L., Zhang, X., Li, Z., Chen, Y., Zhou, J., Ji, F., & Wang, L. (2022) · Biomarker Research · doi:10.1186/s40364-022-00403-2 · Cited by 196
“The HB-Chip design applies passive mixing of blood cells through the generation of microvortices to significantly increase the interactions between the target CTCs and the antibody-coated chip surface [98].”
BackgroundHarouaka, R., Kang, Z., Zheng, S.-Y., & Cao, L. (2014) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2013.10.004 · Cited by 195
DNA Framework-Programmed Cell Capture via Topology-Engineered Receptor–Ligand Interactions
Li, M., Ding, H., Lin, M., Yin, F., Song, L., Mao, X., Li, F., Ge, Z., Wang, L., Zuo, X., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b11015 · Cited by 194
Tumor Dissemination: An EMT Affair
Thiery, J. P., & Lim, C. T. (2013) · Cancer Cell · doi:10.1016/j.ccr.2013.03.004 · Cited by 194
“CTCs can be enriched by loading a blood sample through a high-throughput microfluidic herringbone-chip or HbCTCChip (Stott et al., 2010).”
MethodAn ultra-high-throughput spiral microfluidic biochip for the enrichment of circulating tumor cells
Warkiani, M. E., Khoo, B. L., Tan, D. S.-W., Bhagat, A. A. S., Lim, W.-T., Yap, Y. S., Lee, S. C., Soo, R. A., Han, J., & Lim, C. T. (2014) · The Analyst · doi:10.1039/c4an00355a · Cited by 191
Challenges in the Enumeration and Phenotyping of CTC
Coumans, F. A. W., Ligthart, S. T., Uhr, J. W., & Terstappen, L. W. M. M. (2012) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-12-1585 · Cited by 190
Detection and isolation of circulating tumor cells: Principles and methods
Esmaeilsabzali, H., Beischlag, T. V., Cox, M. E., Parameswaran, A. M., & Park, E. J. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.08.016 · Cited by 189
“10B) (Stott et al., 2010).”
BackgroundSeparation of tumor cells with dielectrophoresis-based microfluidic chip
Alshareef, M., Metrakos, N., Juarez Perez, E., Azer, F., Yang, F., Yang, X., & Wang, G. (2013) · Biomicrofluidics · doi:10.1063/1.4774312 · Cited by 188
Lim, L. S., Hu, M., Huang, M. C., Cheong, W. C., Gan, A. T. L., Looi, X. L., Leong, S. M., Koay, E. S.-C., & Li, M.-H. (2012) · Lab on a Chip · doi:10.1039/c2lc20750h · Cited by 187
Circulating tumor cells: advances in detection methods, biological issues, and clinical relevance
Sun, Y.-F., Yang, X.-R., Zhou, J., Qiu, S.-J., Fan, J., & Xu, Y. (2011) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-011-0988-y · Cited by 184
Antfolk, M., & Laurell, T. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.02.017 · Cited by 184
CTC clusters in cancer progression and metastasis
Fabisiewicz, A., & Grzybowska, E. (2017) · Medical Oncology · doi:10.1007/s12032-016-0875-0 · Cited by 182
“Their presence in the circulation has been observed in patients with various epithelial cancers [43, 50], e.”
BackgroundMethodPoor Prognosis Indicated by Venous Circulating Tumor Cell Clusters in Early-Stage Lung Cancers
Murlidhar, V., Reddy, R. M., Fouladdel, S., Zhao, L., Ishikawa, M. K., Grabauskiene, S., Zhang, Z., Lin, J., Chang, A. C., Carrott, P., et al. (2017) · Cancer Research · doi:10.1158/0008-5472.can-16-2072 · Cited by 181
“CTC clusters or microemboli have been observed rarely in breast, prostate and lung cancers 416 (27,37,49).”
Self-citationDharmasiri, U., Njoroge, S. K., Witek, M. A., Adebiyi, M. G., Kamande, J. W., Hupert, M. L., Barany, F., & Soper, S. A. (2011) · Analytical Chemistry · doi:10.1021/ac103172y · Cited by 181
Armstrong, A. J., Eisenberger, M. A., Halabi, S., Oudard, S., Nanus, D. M., Petrylak, D. P., Sartor, A. O., & Scher, H. I. (2012) · European Urology · doi:10.1016/j.eururo.2011.11.009 · Cited by 181
“Thus improvements in methods for CTC capture through novel CTC chip designs, capture antibodies (mesenchymal antigens, based on prostate-specific membrane antigen), or flow cytometric approaches for improved characterization may enable exploration of CTCs as predictive biomarkers [52–54].”
MethodWang, S., Zheng, L., Cai, G., Liu, N., Liao, M., Li, Y., Zhang, X., & Lin, J. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111333 · Cited by 180
Filter Characteristics Influencing Circulating Tumor Cell Enrichment from Whole Blood
Coumans, F. A. W., van Dalum, G., Beck, M., & Terstappen, L. W. M. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061770 · Cited by 179
“While some assays only perform an erythrocyte lysis or density separation [11–15] other assays achieve enhanced enrichment by leukocyte depletion [16,17], size based filtration [18–24] or antibody based enrichment [25–31].”
MethodHosokawa, M., Kenmotsu, H., Koh, Y., Yoshino, T., Yoshikawa, T., Naito, T., Takahashi, T., Murakami, H., Nakamura, Y., Tsuya, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067466 · Cited by 178
Circulating Tumor Cell Enrichment Based on Physical Properties
Harouaka, R. A., Nisic, M., & Zheng, S.-Y. (2013) · SLAS Technology · doi:10.1177/2211068213494391 · Cited by 174
“Smaller CTC-positive particles (defined as CKCD45 DAPI) were reported after immunological CTC enrichment.(18) CellSearch excludes CTC-positive particles smaller than 4 μm and regards them as cell fragments.”
SpyLigase peptide–peptide ligation polymerizes affibodies to enhance magnetic cancer cell capture
Fierer, J. O., Veggiani, G., & Howarth, M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1315776111 · Cited by 173
“A range of innovative approaches have been taken to enhance CTC capture, including microvortex-generating herringbone chips (37) and microfluidic devices enabling capture of lower expressing cells (38), although magnetic separation has advantages over microfluidics in terms of simplicity and throughput (18, 19).”
BackgroundEngineering fluid flow using sequenced microstructures
Amini, H., Sollier, E., Masaeli, M., Xie, Y., Ganapathysubramanian, B., Stone, H. A., & Di Carlo, D. (2013) · Nature Communications · doi:10.1038/ncomms2841 · Cited by 173
Khoo, B. L., Grenci, G., Lim, Y. B., Lee, S. C., Han, J., & Lim, C. T. (2018) · Nature Protocols · doi:10.1038/nprot.2017.125 · Cited by 172
Jackson, J. M., Witek, M. A., Kamande, J. W., & Soper, S. A. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00016b · Cited by 172
Monolithic Chip for High-throughput Blood Cell Depletion to Sort Rare Circulating Tumor Cells
Fachin, F., Spuhler, P., Martel-Foley, J. M., Edd, J. F., Barber, T. A., Walsh, J., Karabacak, M., Pai, V., Yu, M., Smith, K., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-11119-x · Cited by 171
Self-citationMishra, A., Dubash, T. D., Edd, J. F., Jewett, M. K., Garre, S. G., Karabacak, N. M., Rabe, D. C., Mutlu, B. R., Walsh, J. R., Kapur, R., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2006388117 · Cited by 171
“Various microfluidic platforms have been developed, selecting for CTCs based on their physical attributes, size (13–15) and deformability (16, 17), and immunochemical cell surface markers (18).”
MethodSelf-citationProbing circulating tumor cells in microfluidics
Li, P., Stratton, Z. S., Dao, M., Ritz, J., & Huang, T. J. (2013) · Lab on a Chip · doi:10.1039/c2lc90148j · Cited by 170
Dendrimer‐Mediated Multivalent Binding for the Enhanced Capture of Tumor Cells
Myung, J. H., Gajjar, K. A., Saric, J., Eddington, D. T., & Hong, S. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201105508 · Cited by 169
A Review of Secondary Flow in Inertial Microfluidics
Zhao, Q., Yuan, D., Zhang, J., & Li, W. (2020) · Micromachines · doi:10.3390/mi11050461 · Cited by 168
“proposed the herringbone-chip (HB-chip) utilizing geometry-induced secondary flow to enhance the mixing performance of blood samples [95].”
BackgroundEnrichment, detection and clinical significance of circulating tumor cells
Arya, S. K., Lim, B., & Rahman, A. R. A. (2013) · Lab on a Chip · doi:10.1039/c3lc00009e · Cited by 168
Enrichment and single-cell analysis of circulating tumor cells
Song, Y., Tian, T., Shi, Y., Liu, W., Zou, Y., Khajvand, T., Wang, S., Zhu, Z., & Yang, C. (2017) · Chemical Science · doi:10.1039/c6sc04671a · Cited by 167
Microfluidic technologies for circulating tumor cell isolation
Cho, H., Kim, J., Song, H., Sohn, K. Y., Jeon, M., & Han, K.-H. (2018) · The Analyst · doi:10.1039/c7an01979c · Cited by 167
Tao, J. J., Castel, P., Radosevic-Robin, N., Elkabets, M., Auricchio, N., Aceto, N., Weitsman, G., Barber, P., Vojnovic, B., Ellis, H., et al. (2014) · Science Signaling · doi:10.1126/scisignal.2005125 · Cited by 167
Self-citationEarhart, C. M., Hughes, C. E., Gaster, R. S., Ooi, C. C., Wilson, R. J., Zhou, L. Y., Humke, E. W., Xu, L., Wong, D. J., Willingham, S. B., et al. (2014) · Lab Chip · doi:10.1039/c3lc50580d · Cited by 165
Microfluidic: An innovative tool for efficient cell sorting
Autebert, J., Coudert, B., Bidard, F.-C., Pierga, J.-Y., Descroix, S., Malaquin, L., & Viovy, J.-L. (2012) · Methods · doi:10.1016/j.ymeth.2012.07.002 · Cited by 163
“To increase the probability that cells interact with the surface, chaotic micromixers[106] and “herringbonelike”[107] mixers that createmicrovortices were developed.”
BackgroundCirculating tumour cells, their role in metastasis and their clinical utility in lung cancer
O’Flaherty, J. D., Gray, S., Richard, D., Fennell, D., O’Leary, J. J., Blackhall, F. H., & O’Byrne, K. J. (2012) · Lung Cancer · doi:10.1016/j.lungcan.2011.10.018 · Cited by 163
“Indeed, membrane filtration technology and the HB Chip microfluidic filter are to date the only CTC detection techniques shown to reliably isolate CTMs [74,97].”
BackgroundMethodInfluentialIn vivo capture and label-free detection of early metastatic cells
Azarin, S. M., Yi, J., Gower, R. M., Aguado, B. A., Sullivan, M. E., Goodman, A. G., Jiang, E. J., Rao, S. S., Ren, Y., Tucker, S. L., et al. (2015) · Nature Communications · doi:10.1038/ncomms9094 · Cited by 161
“CTCs are present at low numbers in the blood, and technologies such as microfluidic devices have been designed to capture and quantify the number of CTCs from patient blood samples 2,3 .”
Ahmed, M. G., Abate, M. F., Song, Y., Zhu, Z., Yan, F., Xu, Y., Wang, X., Li, Q., & Yang, C. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201702675 · Cited by 160
Antfolk, M., Magnusson, C., Augustsson, P., Lilja, H., & Laurell, T. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02023 · Cited by 160
Microfluidic Blood Cell Sorting: Now and Beyond
Yu, Z. T. F., Aw Yong, K. M., & Fu, J. (2014) · Small · doi:10.1002/smll.201302907 · Cited by 159
Reátegui, E., Aceto, N., Lim, E. J., Sullivan, J. P., Jensen, A. E., Zeinali, M., Martel, J. M., Aranyosi, A. J., Li, W., Castleberry, S., et al. (2015) · Advanced Materials · doi:10.1002/adma.201404677 · Cited by 159
Self-citationKhoo, B. L., Grenci, G., Jing, T., Lim, Y. B., Lee, S. C., Thiery, J. P., Han, J., & Lim, C. T. (2016) · Science Advances · doi:10.1126/sciadv.1600274 · Cited by 147
Nanotechnology: emerging tools for biology and medicine
Wong, I. Y., Bhatia, S. N., & Toner, M. (2013) · Genes & Development · doi:10.1101/gad.226837.113 · Cited by 132
Self-citationCirculating Tumor Cells: Fluid Surrogates of Solid Tumors
Thiele, J.-A., Bethel, K., Králíčková, M., & Kuhn, P. (2017) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-052016-100256 · Cited by 107
Hyun, K.-A., Lee, T. Y., & Jung, H.-I. (2013) · Analytical Chemistry · doi:10.1021/ac3037766 · Cited by 102
An integrated microfluidic chip for one-step isolation of circulating tumor cells
Lee, T. Y., Hyun, K.-A., Kim, S.-I., & Jung, H.-I. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.05.163 · Cited by 94
Organ-Tumor-on-a-Chip for Chemosensitivity Assay: A Critical Review
Kashaninejad, N., Nikmaneshi, M., Moghadas, H., Kiyoumarsi Oskouei, A., Rismanian, M., Barisam, M., Saidi, M., & Firoozabadi, B. (2016) · Micromachines · doi:10.3390/mi7080130 · Cited by 79
Bhagwat, N., Dulmage, K., Pletcher, C. H., Wang, L., DeMuth, W., Sen, M., Balli, D., Yee, S. S., Sa, S., Tong, F., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-23217-5 · Cited by 75
Microfluidic platform for negative enrichment of circulating tumor cells
Sajay, B. N. G., Chang, C.-P., Ahmad, H., Khuntontong, P., Wong, C. C., Wang, Z., Puiu, P. D., Soo, R., & Rahman, A. R. A. (2014) · Biomedical Microdevices · doi:10.1007/s10544-014-9856-2 · Cited by 56
Rethinking liquid biopsy: Microfluidic assays for mobile tumor cells in human body fluids
Neoh, K. H., Hassan, A. A., Chen, A., Sun, Y., Liu, P., Xu, K.-F., Wong, A. S. T., & Han, R. P. S. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.006 · Cited by 44
Rayavarapu, R. R., Heiden, B., Pagani, N., Shaw, M. M., Shuff, S., Zhang, S., & Schafer, Z. T. (2015) · Journal of Biological Chemistry · doi:10.1074/jbc.m114.612754 · Cited by 42
“Given the aforementioned link between circulating tumor cells and multicellular aggregates (29), we postulated that these aggregates may facilitate the survival of cells that lack proper ECM-attachment.”
BackgroundSelective killing of circulating tumor cells prevents metastasis and extends survival
Kim, Y. R., Yoo, J. K., Jeong, C. W., & Choi, J. W. (2018) · Journal of Hematology & Oncology · doi:10.1186/s13045-018-0658-5 · Cited by 34
Liao, C.-J., Hsieh, C.-H., Wang, H.-M., Chou, W.-P., Chiu, T.-K., Chang, J.-H., Chao, A.-C., & Wu, M.-H. (2017) · RSC Advances · doi:10.1039/c7ra03663a · Cited by 20
Nectin‐4 and p63 immunohistochemical expression in canine prostate tumourigenesis
Della Salda, L., Massimini, M., Romanucci, M., Palmieri, C., Perillo, A., Grieco, V., Malatesta, D., Spinillo, M. A., Passantino, G., Dondi, F., et al. (2019) · Veterinary and Comparative Oncology · doi:10.1111/vco.12469 · Cited by 13
Metadata
- Authors
- Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., Floyd, F. P., Gilman, A. J., Lord, J. B., Winokur, D., Springer, S., Irimia, D., Nagrath, S., Sequist, L. V., Lee, R. J., Isselbacher, K. J., Maheswaran, S., Haber, D. A., & Toner, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-10-07
- Volume
- 107
- Issue
- 43
- Pages
- 18392-18397
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2050827942
- Cited by
- 1,634
- References
- 28
- FWCI
- 60.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.