High-strength silk protein scaffolds for bone repair
Open accessThe DOI matches its Crossref record; 59 of the 61 references it cites were found in a registry or an index.
Abstract
Biomaterials for bone tissue regeneration represent a major focus of orthopedic research. However, only a handful of polymeric biomaterials are utilized today because of their failure to address critical issues like compressive strength for load-bearing bone grafts. In this study development of a high compressive strength (~13 MPa hydrated state) polymeric bone composite materials is reported, based on silk protein-protein interfacial bonding. Micron-sized silk fibers (10–600 µm) obtained utilizing alkali hydrolysis were used as reinforcement in a compact fiber composite with tunable compressive strength, surface roughness, and porosity based on the fiber length included. A combination of surface roughness, porosity, and scaffold stiffness favored human bone marrow-derived mesenchymal stem cell differentiation toward bone-like tissue in vitro based on biochemical and gene expression for bone markers. Further, minimal in vivo immunomodulatory responses suggested compatibility of the fabricated silk-fiber-reinforced composite matrices for bone engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Recently, Mandal et al., reported that SF microfiber incorporation would potentially enhance the stability of scaffolds [31].”
From Development of silk microfiber-reinforced bioink for muscle tissue engineering and in situ printing by a handheld 3D printer (2025) · cites this paper as [31]
The cited source says what the claim attributes to it.
In the citing paper
“Previous studies have highlighted the influence of fiber length on scaffold properties and cell behavior, with medium fiber lengths (150-200 μm) yielding noticeable outcomes [31].”
From Development of silk microfiber-reinforced bioink for muscle tissue engineering and in situ printing by a handheld 3D printer (2025) · cites this paper as [31]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Moreover, medium sized fiber length played an important role in enhancing the mechanical strength with higher concentration of fibers as well as cell-biomaterial interaction positively [31].”
From Development of silk microfiber-reinforced bioink for muscle tissue engineering and in situ printing by a handheld 3D printer (2025) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Bone Tissue Engineering: State of the Art and Future Trends
Salgado, A. J., Coutinho, O. P., & Reis, R. L. (2004) · Macromolecular Bioscience · doi:10.1002/mabi.200400026 · Cited by 1,681 · cited 2×
“However, many challenges remain to satisfy an optimally functional bone regeneration scaffold system (19).”
BackgroundBiomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642 · cited 1×
“approach in engineering to enhance composite strength and has been reported for silk (14, 16, 36, 37).”
New Opportunities for an Ancient Material
Omenetto, F. G., & Kaplan, D. L. (2010) · Science · doi:10.1126/science.1188936 · Cited by 1,457 · cited 2×
“Results and Discussion Previous in vivo and in vitro studies using porous silk scaffolds have shown potential toward reconstruction of bone and bonerelated grafts due to the intrinsic high mechanical strength and robustness (17, 18, 21, 22, 26, 27).”
BackgroundSelf-citationNanoconfinement controls stiffness, strength and mechanical toughness of β-sheet crystals in silk
Keten, S., Xu, Z., Ihle, B., & Buehler, M. J. (2010) · Nature Materials · doi:10.1038/nmat2704 · Cited by 1,391 · cited 1×
“Utilizing these weaker hydrogen bonds within β-sheet nanocrystals, nanoconfinement of such smaller β-sheet nanocrystals in silk achieved higher stiffness, strength, and mechanical toughness as elucidated previously (41, 42).”
BackgroundWei, G., & Ma, P. X. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.005 · Cited by 1,271
Biodegradable polymeric scaffolds for musculoskeletal tissue engineering
Agrawal, C. M., & Ray, R. B. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<141::aid-jbm1000>3.0.co;2-j · Cited by 1,052
Chitosan–alginate hybrid scaffolds for bone tissue engineering
Li, Z., Ramay, H. R., Hauch, K. D., Xiao, D., & Zhang, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.062 · Cited by 1,044 · cited 1×
“1MPa when tested in the dry state (45).”
BackgroundSurprising strength of silkworm silk
Shao, Z., & Vollrath, F. (2002) · Nature · doi:10.1038/418741a · Cited by 1,003
Stem cell-based tissue engineering with silk biomaterials
Wang, Y., Kim, H.-J., Vunjak-Novakovic, G., & Kaplan, D. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.008 · Cited by 968 · cited 2×
“Results and Discussion Previous in vivo and in vitro studies using porous silk scaffolds have shown potential toward reconstruction of bone and bonerelated grafts due to the intrinsic high mechanical strength and robustness (17, 18, 21, 22, 26, 27).”
BackgroundSelf-citationPorous 3-D Scaffolds from Regenerated Silk Fibroin
Nazarov, R., Jin, H.-J., & Kaplan, D. L. (2004) · Biomacromolecules · doi:10.1021/bm034327e · Cited by 888 · cited 1×
“In comparison, control HFIP scaffolds without microfibers showed lower compressive values of approximately 85 kPa, related to the presence of intermolecular hydrogen bonds between silk chains in the β-sheets induced due to methanol treatment (14, 16, 40).”
BackgroundSelf-citationSilk matrix for tissue engineered anterior cruciate ligaments
Altman, G. H., Horan, R. L., Lu, H. H., Moreau, J., Martin, I., Richmond, J. C., & Kaplan, D. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00156-4 · Cited by 863 · cited 2×
“The unique β-sheet (crystalline)-rich structure imparts high stiffness and toughness to silk biomaterials, making it a useful biopolymer for bone engineering applications (23).”
BackgroundSelf-citationIn vivo degradation of three-dimensional silk fibroin scaffolds
Wang, Y., Rudym, D. D., Walsh, A., Abrahamsen, L., Kim, H.-J., Kim, H. S., Kirker-Head, C., & Kaplan, D. L. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.002 · Cited by 789 · cited 2×
“Results and Discussion Previous in vivo and in vitro studies using porous silk scaffolds have shown potential toward reconstruction of bone and bonerelated grafts due to the intrinsic high mechanical strength and robustness (17, 18, 21, 22, 26, 27).”
BackgroundSelf-citationThe inflammatory responses to silk films in vitro and in vivo
Meinel, L., Hofmann, S., Karageorgiou, V., Kirker-Head, C., McCool, J., Gronowicz, G., Zichner, L., Langer, R., Vunjak-Novakovic, G., & Kaplan, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.047 · Cited by 786 · cited 2×
“Further, immune compatibility of pure silk films has already been demonstrated in vivo, inducing a lower inflammatory response than collagen films and PLA films (24).”
BackgroundMethodSelf-citationDeveloping bioactive composite materials for tissue replacement
Wang, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00037-1 · Cited by 753
Müller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., & Rüegsegger, P. (1998) · Bone · doi:10.1016/s8756-3282(98)00068-4 · Cited by 656 · cited 1×
“Further, using salt leaching, control over the range of pore sizes and geometry can be attained by choosing the appropriate salt grain size (in this study 800 μm grains were used) to mimic bone features related to distinct anatomical bone sites (34, 35).”
MethodOsteopontin: a versatile regulator of inflammation and biomineralization
Giachelli, C. M., & Steitz, S. (2000) · Matrix Biology · doi:10.1016/s0945-053x(00)00108-6 · Cited by 583 · cited 1×
“Higher OP and BSP transcript levels are indicative of the maturity of the mineralized matrix where OP is specifically responsible for cell attachment at bone modeling sites, regulation of crystal formation, and growth due to its ability to bind to hydroxyapatite, whereas, BSP enhances nucleation of hydroxyapatite crys…”
BackgroundCell proliferation and migration in silk fibroin 3D scaffolds
Mandal, B. B., & Kundu, S. C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.006 · Cited by 583
Self-citationA critical review on nanotube and nanotube/nanoclay related polymer composite materials
Lau, K.-T., Gu, C., & Hui, D. (2006) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2006.02.020 · Cited by 498 · cited 1×
“approach in engineering to enhance composite strength and has been reported for silk (14, 16, 36, 37).”
BackgroundGanss, B., Kim, R. H., & Sodek, J. (1999) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411990100010401 · Cited by 489
Tissue Engineering of Bone: Material and Matrix Considerations
Khan, Y., Yaszemski, M. J., Mikos, A. G., & Laurencin, C. T. (2008) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.01260 · Cited by 481 · cited 2×
“However, toward, this goal several biological parameters need to be met including biocompatibility, biodegradability, surface roughness, porosity, osteoconductivity, and above all high mechanical integrity (4, 14, 15).”
BackgroundOliveira, J. M., Rodrigues, M. T., Silva, S. S., Malafaya, P. B., Gomes, M. E., Viegas, C. A., Dias, I. R., Azevedo, J. T., Mano, J. F., & Reis, R. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.034 · Cited by 448
Nova, A., Keten, S., Pugno, N. M., Redaelli, A., & Buehler, M. J. (2010) · Nano Letters · doi:10.1021/nl101341w · Cited by 414
Influence of macroporous protein scaffolds on bone tissue engineering from bone marrow stem cells
Kim, H. J., Kim, U.-J., Vunjak-Novakovic, G., Min, B.-H., & Kaplan, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.013 · Cited by 301 · cited 1×
“This enhancement of roughness is an added advantage for these new composite scaffolds as interconnected porous structures are important for new bone tissue regeneration, allowing integration via adequate neovascularization and nutrient/metabolic waste diffusion (19, 27, 33).”
BackgroundSelf-citationPHAGOCYTOSIS: At the Crossroads of Innate and Adaptive Immunity
Jutras, I., & Desjardins, M. (2005) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.20.010403.102755 · Cited by 235 · cited 1×
“One explanation for these differences could be associated with the size of the foreign materials (10– 20 μm silk fibers) inducing greater adhesion and effective phagocytosis by surrounding macrophages compared to larger particles less susceptible to phagocytosis (58).”
BackgroundDe novo engineering of reticular connective tissue in vivo by silk fibroin nonwoven materials
Dal Pra, I., Freddi, G., Minic, J., Chiarini, A., & Armato, U. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.036 · Cited by 210 · cited 1×
“Similarly, studies with silk nonwoven mats implanted subcutaneously in rats induced a weak foreign body response and no fibrosis with little upregulation of inflammatory pathways at the implantation site and no invasion by lymphocytes after 6 mo in vivo (25).”
BackgroundHu, X., Park, S.-H., Gil, E. S., Xia, X.-X., Weiss, A. S., & Kaplan, D. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.037 · Cited by 206
Self-citationXu, C., Su, P., Chen, X., Meng, Y., Yu, W., Xiang, A. P., & Wang, Y. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.068 · Cited by 203
Tissue engineering for bone defect healing: An update on a multi-component approach
Drosse, I., Volkmer, E., Capanna, R., Biase, P. D., Mutschler, W., & Schieker, M. (2008) · Injury · doi:10.1016/s0020-1383(08)70011-1 · Cited by 202
Zhou, Y., Chen, F., Ho, S. T., Woodruff, M. A., Lim, T. M., & Hutmacher, D. W. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.032 · Cited by 202 · cited 1×
“Perhaps the biggest challenge is the need for polymer biomaterials to meet the high compressive properties of bone, a prerequisite to function in vivo (14, 15, 20).”
BackgroundRelationships between degradability of silk scaffolds and osteogenesis
Park, S.-H., Gil, E. S., Shi, H., Kim, H. J., Lee, K., & Kaplan, D. L. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.028 · Cited by 196
Self-citationMechanics of the interface for carbon nanotube–polymer composites
Desai, A. V., & Haque, M. A. (2005) · Thin-Walled Structures · doi:10.1016/j.tws.2005.07.003 · Cited by 193
Multilayered silk scaffolds for meniscus tissue engineering
Mandal, B. B., Park, S.-H., Gil, E. S., & Kaplan, D. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.115 · Cited by 193
Self-citationPolyphosphazene/Nano-Hydroxyapatite Composite Microsphere Scaffolds for Bone Tissue Engineering
Nukavarapu, S. P., Kumbar, S. G., Brown, J. L., Krogman, N. R., Weikel, A. L., Hindenlang, M. D., Nair, L. S., Allcock, H. R., & Laurencin, C. T. (2008) · Biomacromolecules · doi:10.1021/bm800031t · Cited by 189 · cited 1×
“Studies using partially dissolved polyphosphazene have shown a similar effect after binding to nano-hydroxyapatite forming stronger reinforced scaffolds (39).”
BackgroundBone Regeneration on Macroporous Aqueous‐Derived Silk 3‐D Scaffolds
Kim, H. J., Kim, U., Leisk, G. G., Bayan, C., Georgakoudi, I., & Kaplan, D. L. (2007) · Macromolecular Bioscience · doi:10.1002/mabi.200700030 · Cited by 145
Self-citationNihouannen, D. L., Guéhennec, L. L., Rouillon, T., Pilet, P., Bilban, M., Layrolle, P., & Daculsi, G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.038 · Cited by 137
Mandal, B. B., & Kundu, S. C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.064 · Cited by 135
Self-citationYoung's modulus, density and material properties in cancellous bone over a large density range
Hodgskinson, R., & Currey, J. D. (1992) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00705371 · Cited by 129
Reinforcing Silk Scaffolds with Silk Particles
Rajkhowa, R., Gil, E. S., Kluge, J., Numata, K., Wang, L., Wang, X., & Kaplan, D. L. (2010) · Macromolecular Bioscience · doi:10.1002/mabi.200900358 · Cited by 124
Self-citationKang, Y., Scully, A. C., Young, D. A., Kim, S., Tsao, H. W., Sen, M., & Yang, Y. (2011) · European Polymer Journal · doi:10.1016/j.eurpolymj.2011.05.004 · Cited by 121 · cited 1×
“19 MPa, respectively, much lower than our current values with biodegradable silk scaffolds in the hydrated state (46, 47).”
BackgroundThe osteogenic properties of CaP/silk composite scaffolds
Zhang, Y., Wu, C., Friis, T., & Xiao, Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.049 · Cited by 120
Rockwood, D. N., Gil, E. S., Park, S.-H., Kluge, J. A., Grayson, W., Bhumiratana, S., Rajkhowa, R., Wang, X., Kim, S. J., Vunjak-Novakovic, G., et al. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.07.020 · Cited by 119 · cited 4×
“However, toward, this goal several biological parameters need to be met including biocompatibility, biodegradability, surface roughness, porosity, osteoconductivity, and above all high mechanical integrity (4, 14, 15).”
BackgroundResultInfluentialSelf-citationKane, R. J., & Roeder, R. K. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.09.010 · Cited by 119
Porous polymer/bioactive glass composites for soft‐to‐hard tissue interfaces
Zhang, K., Ma, Y., & Francis, L. F. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10227 · Cited by 111
Ultra-fine silk powder preparation through rotary and ball milling
Rajkhowa, R., Wang, L., & Wang, X. (2008) · Powder Technology · doi:10.1016/j.powtec.2008.01.005 · Cited by 108
Dawson, J. I., Wahl, D. A., Lanham, S. A., Kanczler, J. M., Czernuszka, J. T., & Oreffo, R. O. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.040 · Cited by 101
Bone cells-biomaterials interactions
Marquis, M.-È., Lord, É., Bergeron, É., Drevelle, O., Park, H., Cabana, F., Senta, H., & Faucheux, N. (2009) · Frontiers in bioscience · doi:10.2741/3293 · Cited by 88 · cited 1×
“However, current treatments mostly rely on autografts or allografts but have associated risks, with autografts needing an additional surgical site and limits to supply, and allografts having potential risks of disease transmission and longterm complications (3, 4).”
BackgroundFabrication of ultrafine powder from eri silk through attritor and jet milling
Rajkhowa, R., Wang, L., Kanwar, J. R., & Wang, X. (2008) · Powder Technology · doi:10.1016/j.powtec.2008.10.004 · Cited by 88
Wang, Y., Dai, J., Zhang, Q., Xiao, Y., & Lang, M. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2010.03.127 · Cited by 86
Ochi, K., Chen, G., Ushida, T., Gojo, S., Segawa, K., Tai, H., Ueno, K., Ohkawa, H., Mori, T., Yamaguchi, A., et al. (2002) · Journal of Cellular Physiology · doi:10.1002/jcp.10185 · Cited by 80
Mechanical improvements to reinforced porous silk scaffolds
Gil, E. S., Kluge, J. A., Rockwood, D. N., Rajkhowa, R., Wang, L., Wang, X., & Kaplan, D. L. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33158 · Cited by 73 · cited 19×
“Currently, bone graft/scaffold engineering using silk biomaterials has received increasing interest as an alternative option (14, 15, 17, 18).”
BackgroundInfluentialSelf-citationBalloni, S., Calvi, E. M., Damiani, F., Bistoni, G., Calvitti, M., Locci, P., Becchetti, E., & Marinucci, L. (2009) · PubMed · Cited by 63
Decontaminating particles exposed to bacterial endotoxin (LPS)
Hitchins, V. M., & Merritt, K. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990905)46:3<434::aid-jbm17>3.0.co;2-l · Cited by 57
Coleman, D., & Howitt, F. O. (1947) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1947.0067 · Cited by 57
Mandal, B. B., & Kundu, S. C. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.02.033 · Cited by 54
Self-citationThein-Han, W. W., Shah, J. S., & Misra, R. D. K. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.04.029 · Cited by 46
Coleman, D., & Howitt, F. O. (1947) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1947.0031 · Cited by 9 · cited 1×
“, arginine (1% in silk) and serine (13% in silk)] are destroyed in the process, but others are racemized (31).”
Background
Research works printed but not linked: 2
- Hutmacher DW, et al. Mechanical properties and cell cultural response of polycaprolactone scaffolds designed and fabricated via fused deposition modeling. J Biomed Mater Res. 2001;55:203–216. doi: 10.1002/1097-4636(200105)55:2<203::aid-jbm1007>3.0.co;2-7. [DOI] [PubMed] [Google Scholar] · DOI · Paper page
- Santin M, Motta A, Freddi G, Cannas M. In vitro evaluation of the inflammatory potential of the silk fibroin. J Biomed Mater Res. 1999;46:382–389. doi: 10.1002/(sici)1097-4636(19990905)46:3<382::aid-jbm11>3.0.co;2-r. [DOI] [PubMed] [Google Scholar] · DOI · Paper page
Cited by
Silk fibroin biomaterials for tissue regenerations
Kundu, B., Rajkhowa, R., Kundu, S. C., & Wang, X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.043 · Cited by 1,391
“Further modifications to scaffolds include reinforcement with fine silk fibers to gain further improvement in modulus to about 13 MPa [105].”
MethodInfluential3D bioactive composite scaffolds for bone tissue engineering
Turnbull, G., Clarke, J., Picard, F., Riches, P., Jia, L., Han, F., Li, B., & Shu, W. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.10.001 · Cited by 1,332
The Biomedical Use of Silk: Past, Present, Future
Holland, C., Numata, K., Rnjak‐Kovacina, J., & Seib, F. P. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201800465 · Cited by 815
Silk fibroin as biomaterial for bone tissue engineering
Melke, J., Midha, S., Ghosh, S., Ito, K., & Hofmann, S. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.09.005 · Cited by 789
“Removal of the water-soluble sericin protein coat from the cocoon yields degummed silk fibers with a similar Young’s modulus but an altered tensile strength of 450 to 700 MPa at an elongation of 12-24% [62].”
BackgroundInfluentialQi, Y., Wang, H., Wei, K., Yang, Y., Zheng, R.-Y., Kim, I., & Zhang, K.-Q. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18030237 · Cited by 547
“Due to their excellent performance, SF-based biomaterials have been found suitable for a variety of applications, including drug delivery [9], vascular tissue regeneration [10], skin wound dressing [11], and bone tissue scaffolds [12].”
Background
Metadata
- Authors
- Mandal, B. B., Grinberg, A., Seok Gil, E., Panilaitis, B., & Kaplan, D. L.
- Affiliations
- Tufts University (US)
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155;
- Corresponding author
- Kaplan, David L.
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2012-05-02
- Volume
- 109
- Issue
- 20
- Pages
- 7699-7704
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC3356671
- OpenAlex
- W1981076043
- Cited by
- 401
- References
- 61
- Citations by year
- 2026: 17 · 2025: 18 · 2024: 22 · 2023: 17 · 2022: 25 · 2021: 29 · 2020: 34 · 2019: 33 · 2018: 36 · 2017: 49 · 2016: 38 · 2015: 26 · 2014: 35 · 2013: 16 · 2012: 6
- FWCI
- 10.76
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (EB002520)
- National Institute of Biomedical Imaging and Bioengineering (EB-002520, EB 003210, R01EB003210, P41EB002520)
- National Institute of Dental and Craniofacial Research (DE017207, R01DE017207)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Keywords
- bone tissue engineering, bone regeneration, silk fibers, alkaline hydrolysis, fiber-reinforced composites, compressive strength, mesenchymal stem cells, osteogenic differentiation, porosity, surface roughness, scaffold stiffness, immunocompatibility, bone grafting
- MeSH terms
- Analysis of Variance, Animals, Biocompatible Materials, Biomechanical Phenomena, Bone Regeneration, Cell Differentiation, Female, Materials Testing, Mice, Inbred BALB C, Microscopy, Electron, Scanning, Bombyx, Compressive Strength, Tissue Engineering, Regenerative Medicine, Silk, Mice, Tissue Scaffolds, Mesenchymal Stem Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.