‘MINFLUX monitors rapid molecular jumps with superior spatiotemporal resolution’
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Significance: Popular localization of single molecules through calculating the centroid of the diffraction pattern produced by molecular fluorescence on a camera is typically limited to spatiotemporal resolutions of >10 nm per >10 milliseconds. By requiring at least 10–100 times fewer detected photons and being free of bias due to molecular orientation, the localization concept called MINFLUX propels molecular tracking to the hitherto-unachievable regime of single-digit nanometer precision within substantially less than a millisecond. Our experiments herald the feasibility to detect molecular interactions and conformational changes at microsecond timescales.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, advanced MINFLUX microscopy from the Hell lab enables the tracking of particles as small as 1–2 nm for 100 s of microseconds (Eilers et al., 2018; Schmidt et al., 2021).”
From Molecular dynamics simulation of an entire cell (2023) · cites this paper as Eilers et al., 2018
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Folding DNA to create nanoscale shapes and patterns
Rothemund, P. W. K. (2006) · Nature · doi:10.1038/nature04586 · Cited by 7,354 · cited 1×
“Two extended ssDNA attached to a modified Rothemund rectangle (31) were base paired with a DNA bridge strand.”
BackgroundHell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065 · cited 1×
“F nanoscopy methods such as those called stimulated emission depletion (STED)/reversible saturable optical linear fluorescence transitions (RESOLFT) microscopy (1, 2) and photoactivated localization microscopy (PALM)/stochastic optical reconstruction microscopy (STORM) (3–5) routinely achieve 20- to 50-nm spatial reso…”
MethodSelf-citationEvidence for the Formation of Symmetric and Asymmetric DLPC-DAPC Lipid Bilayer Domains
Ritter, M., Schmidt, S., Jakab, M., Paulmichl, M., & Henderson, R. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350122 · Cited by 3,923
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Self-citationPrecise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
A practical guide to single-molecule FRET
Roy, R., Hohng, S., & Ha, T. (2008) · Nature Methods · doi:10.1038/nmeth.1208 · Cited by 2,152 · cited 1×
“Besides, unlike FRET, MINFLUX does not entail a photophysically constrained range of action (32) nor does it require multiple labels.”
BackgroundFluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869 · cited 1×
“F nanoscopy methods such as those called stimulated emission depletion (STED)/reversible saturable optical linear fluorescence transitions (RESOLFT) microscopy (1, 2) and photoactivated localization microscopy (PALM)/stochastic optical reconstruction microscopy (STORM) (3–5) routinely achieve 20- to 50-nm spatial reso…”
MethodSelf-citation
Cited by
MINFLUX nanoscopy delivers 3D multicolor nanometer resolution in cells
Gwosch, K. C., Pape, J. K., Balzarotti, F., Hoess, P., Ellenberg, J., Ries, J., & Hell, S. W. (2020) · Nature Methods · doi:10.1038/s41592-019-0688-0 · Cited by 585
Self-citationSchmidt, R., Weihs, T., Wurm, C. A., Jansen, I., Rehman, J., Sahl, S. J., & Hell, S. W. (2021) · Nature Communications · doi:10.1038/s41467-021-21652-z · Cited by 306
Self-citationFluorescent Nanoparticles for Super-Resolution Imaging
Li, W., Kaminski Schierle, G. S., Lei, B., Liu, Y., & Kaminski, C. F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00050 · Cited by 278
Müller, D. J., Dumitru, A. C., Lo Giudice, C., Gaub, H. E., Hinterdorfer, P., Hummer, G., De Yoreo, J. J., Dufrêne, Y. F., & Alsteens, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00617 · Cited by 259
Super-Resolution Microscopy for Structural Cell Biology
Liu, S., Hoess, P., & Ries, J. (2022) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-102521-112912 · Cited by 220
MINFLUX dissects the unimpeded walking of kinesin-1
Wolff, J. O., Scheiderer, L., Engelhardt, T., Engelhardt, J., Matthias, J., & Hell, S. W. (2023) · Science · doi:10.1126/science.ade2650 · Cited by 188
“For a given NN, MINFLUX (17-20) typically renders a STR of σσ √ττ ⁄ with about 10-fold”
BackgroundSelf-citationDirect observation of motor protein stepping in living cells using MINFLUX
Deguchi, T., Iwanski, M. K., Schentarra, E.-M., Heidebrecht, C., Schmidt, L., Heck, J., Weihs, T., Schnorrenberg, S., Hoess, P., Liu, S., et al. (2023) · Science · doi:10.1126/science.ade2676 · Cited by 167
“By efficiently utilizing the limited photon budget of single fluorophores, MINFLUX has reached unprecedented spatial resolution for imaging ( 10 – 12 ) and temporal resolution for fluorophore tracking ( 13 , 14 ).”
MethodMolecular dynamics simulation of an entire cell
Stevens, J. A., Grünewald, F., van Tilburg, P. A. M., König, M., Gilbert, B. R., Brier, T. A., Thornburg, Z. R., Luthey-Schulten, Z., & Marrink, S. J. (2023) · Frontiers in Chemistry · doi:10.3389/fchem.2023.1106495 · Cited by 156
“For example, advanced MINFLUX microscopy from the Hell lab enables the tracking of particles as small as 1 – 2 nm for 100 s of microseconds (Eilers et al., 2018; Schmidt et al., 2021).”
MethodPan, A., Zuo, C., & Yao, B. (2020) · Reports on Progress in Physics · doi:10.1088/1361-6633/aba6f0 · Cited by 163
Technological advances in super-resolution microscopy to study cellular processes
Bond, C., Santiago-Ruiz, A. N., Tang, Q., & Lakadamyali, M. (2022) · Molecular Cell · doi:10.1016/j.molcel.2021.12.022 · Cited by 135
Ostersehlt, L. M., Jans, D. C., Wittek, A., Keller‐Findeisen, J., Inamdar, K., Sahl, S. J., Hell, S. W., & Jakobs, S. (2022) · Nature Methods · doi:10.1038/s41592-022-01577-1 · Cited by 116
Self-citationOne-step nanoscale expansion microscopy reveals individual protein shapes
Shaib, A. H., Chouaib, A. A., Chowdhury, R., Altendorf, J., Mihaylov, D., Zhang, C., Krah, D., Imani, V., Spencer, R. K. W., Georgiev, S. V., et al. (2025) · Nature Biotechnology · doi:10.1038/s41587-024-02431-9 · Cited by 104
Circumvention of common labelling artefacts using secondary nanobodies
Sograte-Idrissi, S., Schlichthaerle, T., Duque-Afonso, C. J., Alevra, M., Strauss, S., Moser, T., Jungmann, R., Rizzoli, S. O., & Opazo, F. (2020) · Nanoscale · doi:10.1039/d0nr00227e · Cited by 108
Masullo, L. A., Steiner, F., Zähringer, J., Lopez, L. F., Bohlen, J., Richter, L., Cole, F., Tinnefeld, P., & Stefani, F. D. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c04600 · Cited by 107
Chemical Analysis of Single Cells
Oomen, P. E., Amiri-Aref, M., Kaya, I., Phan, N. T. N., & Ewing, A. G. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04732 · Cited by 102
Direct observation of water-mediated single-proton transport between hBN surface defects
Comtet, J., Grosjean, B., Glushkov, E., Avşar, A., Watanabe, K., Taniguchi, T., Vuilleumier, R., Bocquet, M., & Radenovic, A. (2020) · Nature Nanotechnology · doi:10.1038/s41565-020-0695-4 · Cited by 99
Super-resolution Microscopy for Nanomedicine Research
Pujals, S., & Albertazzi, L. (2019) · ACS Nano · doi:10.1021/acsnano.9b05289 · Cited by 85
Direct optical measurement of intramolecular distances with angstrom precision
Sahl, S. J., Matthias, J., Inamdar, K., Weber, M., Khan, T. A., Brüser, C., Jakobs, S., Becker, S., Griesinger, C., Broichhagen, J., et al. (2024) · Science · doi:10.1126/science.adj7368 · Cited by 90
Self-citationSIMPLE: Structured illumination based point localization estimator with enhanced precision
Reymond, L., Ziegler, J., Knapp, C., Wang, F.-C., Huser, T. R., Ruprecht, V., & Wieser, S. (2019) · Optics Express · doi:10.1364/oe.27.024578 · Cited by 80
Mau, A., Friedl, K., Leterrier, C., Bourg, N., & Lévêque‐Fort, S. (2021) · Nature Communications · doi:10.1038/s41467-021-23405-4 · Cited by 79
Transcription Factor Dynamics: One Molecule at a Time
Wagh, K., Stavreva, D. A., Upadhyaya, A., & Hager, G. L. (2023) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-022823-013847 · Cited by 73
Jahr, W., Velicky, P., & Danzl, J. G. (2019) · Methods · doi:10.1016/j.ymeth.2019.07.019 · Cited by 67
Single-molecule methods in structural DNA nanotechnology
Platnich, C. M., Rizzuto, F. J., Cosa, G., & Sleiman, H. F. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00776h · Cited by 52
Khater, I. M., Liu, Q., Chou, K. C., Hamarneh, G., & Nabi, I. R. (2019) · Scientific Reports · doi:10.1038/s41598-019-46174-z · Cited by 55
An alternative to MINFLUX that enables nanometer resolution in a confocal microscope
Masullo, L. A., Szalai, A. M., Lopez, L. F., Pilo‐Pais, M., Acuna, G. P., & Stefani, F. D. (2022) · Light Science & Applications · doi:10.1038/s41377-022-00896-4 · Cited by 57
Development of ultrafast camera-based single fluorescent-molecule imaging for cell biology
Fujiwara, T. K., Takeuchi, S., Kalay, Z., Nagai, Y., Tsunoyama, T. A., Kalkbrenner, T., Iwasawa, K., Ritchie, K. P., Suzuki, K. G. N., & Kusumi, A. (2023) · The Journal of Cell Biology · doi:10.1083/jcb.202110160 · Cited by 49
“However, improving the temporal resolution is critically important (Balzarotti et al., 2017; Eilers et al., 2018; Koyama-Honda et al., 2020; Schmidt et al., 2021) for observing living cells, and particularly for investigating the dynamic movements and interactions of molecules at the single molecule level (Baboolal et…”
BackgroundTwo-photon MINFLUX with doubled localization precision
Zhao, K., Xu, X., Ren, W., Jin, D., & Xi, P. (2022) · eLight · doi:10.1186/s43593-021-00011-x · Cited by 49
“This may be of use not only for nanometer-precision localization microscopy [11, 12], but also simultaneous tracking [10] of several fluorophores.”
BackgroundDeep learning-driven adaptive optics for single-molecule localization microscopy
Zhang, P., Ma, D., Cheng, X., Tsai, A. P., Tang, Y., Gao, H.-C., Fang, L., Bi, C., Landreth, G. E., Chubykin, A. A., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-02029-0 · Cited by 42
Modulation-enhanced localization microscopy
Reymond, L., Huser, T. R., Ruprecht, V., & Wieser, S. (2020) · Journal of Physics Photonics · doi:10.1088/2515-7647/ab9eac · Cited by 43
“MINFLUX can achieve better localization than the theoretical limit of SMLMmethods and was extended to isotropic 3D localization precision [33, 34].”
BackgroundAccelerated MINFLUX Nanoscopy, through Spontaneously Fast‐Blinking Fluorophores
Remmel, M., Scheiderer, L., Butkevich, A. N., Bossi, M. L., & Hell, S. W. (2023) · Small · doi:10.1002/smll.202206026 · Cited by 44
Self-citationFluorescence microscopy: A statistics-optics perspective
Fazel, M., Grußmayer, K. S., Ferdman, B., Rađenović, A., Shechtman, Y., Enderlein, J., & Pressé, S. (2024) · Reviews of Modern Physics · doi:10.1103/revmodphys.96.025003 · Cited by 47
Considerations of Antibody Geometric Constraints on NK Cell Antibody Dependent Cellular Cytotoxicity
Murin, C. D. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.01635 · Cited by 50
MINFLUX achieves molecular resolution with minimal photons
Scheiderer, L., Marin, Z., & Ries, J. (2025) · Nature Photonics · doi:10.1038/s41566-025-01625-0 · Cited by 51
“4a), MINFLUX tracking achieved a localization precision of ~2 nm with a 400 µs time resolution using 100 fluorescent photons per localization 39 (Fig.”
Super-resolved FRET and co-tracking in pMINFLUX
Cole, F., Zähringer, J., Bohlen, J., Schröder, T., Steiner, F., Pfeiffer, M., Schüler, P., Stefani, F. D., & Tinnefeld, P. (2024) · Nature Photonics · doi:10.1038/s41566-024-01384-4 · Cited by 38
“MINFLUX can reach submillisecond temporal resolution ideal for tracking applications with strikingly optimized photon budg-ets 21,22 .”
Anselmo, S., Bonaccorso, E., Gangemi, C. M. A., Sancataldo, G., Nibali, V. C., & D’Angelo, G. (2025) · Membranes · doi:10.3390/membranes15010006 · Cited by 34
“This technique can provide groundbreaking insights, such as the direct tracking of individual lipid molecules, helping to unravel the intricate dynamics of membrane rafts in living cells [165].”
Diaspro, A., & Bianchini, P. (2020) · Rivista Del Nuovo Cimento · doi:10.1007/s40766-020-00008-1 · Cited by 37
Chasing Uptake: Super-Resolution Microscopy in Endocytosis and Phagocytosis
Baranov, M. V., Olea, A. R., & van den Bogaart, G. (2019) · Trends in Cell Biology · doi:10.1016/j.tcb.2019.05.006 · Cited by 34
Shedding light on membrane rafts structure and dynamics in living cells
Nieto‐Garai, J. A., Lorizate, M., & Contreras, F. ‐. (2021) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2021.183813 · Cited by 40
Label-Free Super-Resolution Imaging Techniques
Leighton, R., Alperstein, A. M., & Frontiera, R. R. (2022) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061020-014723 · Cited by 38
A guide to small fluorescent probes for single-molecule biophysics
Leake, M. C., & Quinn, S. D. (2023) · Chemical Physics Reviews · doi:10.1063/5.0131663 · Cited by 30
Kohler, L., Mader, M., Kern, C., Wegener, M., & Hunger, D. (2021) · Nature Communications · doi:10.1038/s41467-021-26719-5 · Cited by 28
“Their further development enables the tracking of individual nanosystems [4–6].”
BackgroundHigh-Resolution 3D Light Microscopy with STED and RESOLFT
Sahl, S. J., & Hell, S. W. (2019) · Springer eBooks · doi:10.1007/978-3-030-16638-0_1 · Cited by 38
Self-citationHeat denaturation enables multicolor X10-STED microscopy
Saal, K. A., Shaib, A., Mougios, N., Crzan, D., Opazo, F., & Rizzoli, S. O. (2023) · Scientific Reports · doi:10.1038/s41598-023-32524-5 · Cited by 35
The Decade of Super-Resolution Microscopy of the Presynapse
Nosov, G., Kahms, M., & Klingauf, J. (2020) · Frontiers in Synaptic Neuroscience · doi:10.3389/fnsyn.2020.00032 · Cited by 29
Shedding New Lights Into STED Microscopy: Emerging Nanoprobes for Imaging
Liu, Y., Peng, Z., Peng, X., Yan, W., Yang, Z., & Qu, J. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.641330 · Cited by 26
Fluorescence nanoscopy at the sub-10 nm scale
Masullo, L. A., Szalai, A. M., Lopez, L. F., & Stefani, F. D. (2021) · Biophysical Reviews · doi:10.1007/s12551-021-00864-z · Cited by 31
Zdańkowski, P., Trusiak, M., McGloin, D., & Swedlow, J. R. (2019) · ACS Nano · doi:10.1021/acsnano.9b05891 · Cited by 28
Super‐resolution imaging: when biophysics meets nanophotonics
Koenderink, A. F., Tsukanov, R., Enderlein, J., Izeddin, I., & Krachmalnicoff, V. (2021) · Nanophotonics · doi:10.1515/nanoph-2021-0551 · Cited by 31
“With MINFLUX, it is indeed possible to localize single molecules with sub-nanometer accuracy by detecting as few as some hundred photons [65, 84].”
Background4D Single-particle tracking with asynchronous read-out single-photon avalanche diode array detector
Bucci, A., Tortarolo, G., Held, M. O., Bega, L., Perego, E., Castagnetti, F., Bozzoni, I., Slenders, E., & Vicidomini, G. (2024) · Nature Communications · doi:10.1038/s41467-024-50512-9 · Cited by 29
Li, C., Le, V., Wang, X., Hao, X., Liu, X., & Kuang, C. (2020) · Laser & Photonics Review · doi:10.1002/lpor.201900084 · Cited by 25
Achimovich, A. M., Ai, H., & Gahlmann, A. (2019) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2019.05.001 · Cited by 23
“In a recent demonstration of MINFLUX tracking, the DNAtethered dye ATTO647N yielded a count rate of 350 kHz, when excited slightly below its excitation saturation threshold [13].”
BackgroundIntroduction to Fluorescence Microscopy
Macháň, R. (2022) · Springer series on fluorescence · doi:10.1007/4243_2022_34 · Cited by 21
Díaz, Y. D. L. M. Z., & Arnspang, E. C. (2024) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2024.1455153 · Cited by 25
Microscope-Cockpit: Python-based bespoke microscopy for bio-medical science
Phillips, M. A., Pinto, D. M. S., Hall, N., Langerak, J. M., Parton, R. M., Titlow, J., Stoychev, D., Parks, T., Pinto, T. S., Sedat, J. W., et al. (2021) · Wellcome Open Research · doi:10.12688/wellcomeopenres.16610.1 · Cited by 19
Application of STED imaging for chromatin studies
Kostiuk, G., Bucevičius, J., Gerasimaitė, R., & Lukinavičius, G. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab4410 · Cited by 19
Super-Resolution Microscopy to Study Interorganelle Contact Sites
Nieto‐Garai, J. A., Olazar‐Intxausti, J., Anso, I., Lorizate, M., Terrones, O., & Contreras, F. ‐. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232315354 · Cited by 20
Advanced optical imaging for the rational design of nanomedicines
Ortiz‐Perez, A., Zhang, M., Fitzpatrick, L. W., Izquierdo-Lozano, C., & Albertazzi, L. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.115138 · Cited by 19
Wang, L., Chen, Y., Guo, J., Weng, X., Yan, W., Song, J., Ye, T., & Qu, J. (2025) · Light Science & Applications · doi:10.1038/s41377-024-01711-y · Cited by 22
Low-power STED nanoscopy based on temporal and spatial modulation
Wang, L., Chen, Y., Guo, Y., Xie, W., Yang, Z., Weng, X., Yan, W., & Qu, J. (2021) · Nano Research · doi:10.1007/s12274-021-3874-1 · Cited by 19
Liu, J., Liu, Z., Mi, F., Yao, Z., Fang, X., Wang, Y., Zhao, Z., & Wu, C. (2023) · Chemical & Biomedical Imaging · doi:10.1021/cbmi.3c00058 · Cited by 19
MINFLUX reveals dynein stepping in live neurons
Schleske, J. M., Hubrich, J., Wirth, J. O., D’Este, E., Engelhardt, J., & Hell, S. W. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2412241121 · Cited by 23
“In contrast, popular fluorophore localization methods that rely on the identification of the maximum of the fluorescence diffraction pattern produced by the fluorophore on a camera (i.e., centroid calculation) require about one hundred times more detected photons per fluorophore ( 26 ).”
Self-citationMINSTED tracking of single biomolecules
Scheiderer, L., von der Emde, H., Hesselink, M., Weber, M., & Hell, S. W. (2024) · Nature Methods · doi:10.1038/s41592-024-02209-6 · Cited by 16
“A way out of this catch is offered by localization through optical coordinate-targeting as realized in the methods called MINFLUX 5,6 and MINSTED 7 .”
MethodSelf-citationMINFLUX nanoscopy enhanced with high-order vortex beams
Tan, X.-J., & Huang, Z. (2025) · Light Science & Applications · doi:10.1038/s41377-025-01822-0 · Cited by 15
“…controllable fl uorescence excitation, MINFLUX has delivered exceptionally high resolution for the observation of various biological samples and processes, facilitating a deeper understanding of cellular dynamics, protein interactions, and complex biological mechanisms at a molecular level 5 – 17 .”
Staudt, T., Aspelmeier, T., Laitenberger, O., Geisler, C., Egner, A., & Munk, A. (2020) · Statistical Science · doi:10.1214/19-sts753 · Cited by 15
“Other methodologies, like MINFLUX [3, 15], rely on a statistical treatment by design.”
MethodReal-time single-molecule 3D tracking in E. coli based on cross-entropy minimization
Amselem, E., Broadwater, D. W. B., Hävermark, T., Johansson, M., & Elf, J. (2023) · Nature Communications · doi:10.1038/s41467-023-36879-1 · Cited by 18
“(8), a more dynamic but tighter constraint is of interest for the fluorophore photon efficiency.”
BackgroundInfluentialImaging Endocytosis Dynamics in Health and Disease
Tagliatti, E., & Cortese, K. (2022) · Membranes · doi:10.3390/membranes12040393 · Cited by 18
MINFLUX nanoscopy: Visualising biological matter at the nanoscale level
Carsten, A., Failla, A. V., & Aepfelbacher, M. (2024) · Journal of Microscopy · doi:10.1111/jmi.13306 · Cited by 18
“…was included in the latter publication and is now provided in Figure 3 Besides the first MINFLUX tracking results described above, 21 further tracking experiments on lipid diffusion in a supported lipid bilayer 27 and thermally fluctuating DNA strands 30 in model systems have been performed.”
Hoboth, P., Šebesta, O., & Hozák, P. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22136694 · Cited by 13
“As a result, MINFLUX and its derived fluorescence nanoscopy techniques require up to orders of magnitude fewer photon emissions to deliver single‐digit nanometer spatial resolution and 100‐times improved temporal resolution as compared to its parent imaging approaches [50].”
BackgroundIn-Cell Dynamics: The Next Focus of All-Atom Simulations
Samuel, P. P., Alaeen, S., & Pogorelov, T. V. (2023) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.3c05166 · Cited by 15
Can single molecule localization microscopy detect nanoclusters in T cells?
Feher, K., Halstead, J. M., Goyette, J., & Gaus, K. (2019) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2019.05.019 · Cited by 14
New advances in the research of stimulated emission depletion super-resolution microscopy
Wang, J.-L., Yan, W., Zhang, J., Wang, L., Yang, Z., & Qu, J. (2020) · Acta Physica Sinica · doi:10.7498/aps.69.20200168 · Cited by 12
Through the Eyes of Creators: Observing Artificial Molecular Motors
Unksov, I. N., Korosec, C. S., Surendiran, P., Verardo, D., Lyttleton, R. W., Forde, N. R., & Linke, H. (2022) · ACS Nanoscience Au · doi:10.1021/acsnanoscienceau.1c00041 · Cited by 14
4Pi MINFLUX arrangement maximizes spatio-temporal localization precision of fluorescence emitter
Rickert, J. D., Held, M. O., Engelhardt, J., & Hell, S. W. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2318870121 · Cited by 11
Self-citationRudinskiy, M., Morone, D., & Molinari, M. (2024) · Traffic · doi:10.1111/tra.12957 · Cited by 11
“…Stimulation Emission Depletion (STED) [198] and its derivatives RESOLFT (Reversible Saturable OpticaL Fluorescence Transitions) [199], MINFLUX [200, 201] and MINSTED [202, 203], achieve the goal by sequentially turning on/off portions of the sample with laser scanning ( on/off at different…”
Nanoscale imaging of biological systems via expansion and super-resolution microscopy
Aristova, D., Kylies, D., Rosario, M. D., Heil, H. S., Schwerk, M., Kuehl, M. B., Wong, M. N., Henriques, R., & Puelles, V. G. (2025) · Applied Physics Reviews · doi:10.1063/5.0240464 · Cited by 11
Reina, F., Saavedra, L. A., Eggeling, C., & Barrantes, F. J. (2025) · Nature Communications · doi:10.1038/s41467-025-61489-4 · Cited by 11
“In particular, if there are some new phenomena that was not observed before, if there are experiments or data analysis performed for the first time here, that were not possible before due to limitations of classical techniques, and which results and measured parameters agree or not with previous…”
Modulated illumination localization microscopy-enabled sub-10 nm resolution
Sun, Y., Yin, L., Cai, M., Wu, H., Hao, X., Kuang, C., & Liu, X. (2022) · Journal of Innovative Optical Health Sciences · doi:10.1142/s179354582230004x · Cited by 10
“22 To overcome the shortcomings of MINFLUX and retaining its ultra-high resolution, several single molecule localization wide-¯eld microscopies based on modulated illumination have been proposed in recent years (Fig.”
BackgroundPrindle, J. R., de Cuba, O., & Gahlmann, A. (2023) · The Journal of Chemical Physics · doi:10.1063/5.0155638 · Cited by 12
Fluorescence Nanoscopy in Neuroscience
Wang, Y., Lin, J., Zhang, Q., Chen, X., Luan, H., & Gu, M. (2021) · Engineering · doi:10.1016/j.eng.2020.11.010 · Cited by 11
Molecular probes for super-resolution imaging of drug dynamics
Fang, H., Wang, M., Wei, P., Liu, Q., Su, Y. R., Liu, H., Chen, Y., Su, Z. G., & He, W. (2024) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2024.115330 · Cited by 10
Effects of optical aberrations on localization of MINFLUX super-resolution microscopy
He, C., Zhan, Z., Li, C., Sun, X., Liu, Y., Kuang, C., & Liu, X. (2022) · Optics Express · doi:10.1364/oe.475425 · Cited by 9
Uncovering kinesin dynamics in neurites with MINFLUX
Wirth, J. O., Schentarra, E.-M., Scheiderer, L., Macarrón‐Palacios, V., Tarnawski, M., & Hell, S. W. (2024) · Communications Biology · doi:10.1038/s42003-024-06358-4 · Cited by 13
“Iterative matching of this minimal intensity center with the position of the fl uorophore substantially reduces the number of photon detections requiredforattainingacertainlocalizationprecision,typicallybyabout100-fold 14 .”
BackgroundSelf-citationSimple and robust 3D MINFLUX excitation with a variable phase plate
Deguchi, T., & Ries, J. (2024) · Light Science & Applications · doi:10.1038/s41377-024-01487-1 · Cited by 9
Fluorescence Microscopy with Nanometer Resolution
Sahl, S. J., Schönle, A., & Hell, S. W. (2019) · Springer handbooks · doi:10.1007/978-3-030-00069-1_22 · Cited by 10
Self-citationEmerging Research on Gene Delivery to the Nucleus via DNA Origami
Sterling, S. A., Wei, Y., Arya, G., Castro, C. E., & Ke, Y. (2025) · JACS Au · doi:10.1021/jacsau.5c00737 · Cited by 8
Surpassing the Diffraction Limit in Label-Free Optical Microscopy
Palounek, D., Vala, M., Bujak, Ł., Kopal, I., Jiříková, K., Shaidiuk, Y., & Piliarik, M. (2024) · ACS Photonics · doi:10.1021/acsphotonics.4c00745 · Cited by 10
Chan, C. Y., Faragalla, Y., & Wu, L. (2022) · Biochemical Society Transactions · doi:10.1042/bst20210263 · Cited by 9
Fluorescence microscopy at the molecular scale
Alvelid, J., & Testa, I. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.09.009 · Cited by 8
Quantitative single-molecule imaging of protein assembly in membranes
Jenner, A., Shalaby, R., & Cosentino, K. (2020) · Advances in biomembranes and lipid self-assembly · doi:10.1016/bs.abl.2020.02.004 · Cited by 8
Chip-compatible wide-field 3D nanoscopy through tunable spatial frequency shift effect
Liu, X., Tang, M., Meng, C., Pang, C., Kuang, C., Chen, W., Kaminski, C. F., Yang, Q., & Liu, X. (2021) · Science China Physics Mechanics and Astronomy · doi:10.1007/s11433-020-1682-1 · Cited by 9
Ultra high-speed single-molecule fluorescence imaging
Huang, Z., & Kanchanawong, P. (2023) · The Journal of Cell Biology · doi:10.1083/jcb.202306136 · Cited by 7
Computational Proposal for Tracking Multiple Molecules in a Multifocus Confocal Setup
Jazani, S., Xu, L. W. Q., Sgouralis, I., Shepherd, D. P., & Pressé, S. (2022) · ACS Photonics · doi:10.1021/acsphotonics.2c00614 · Cited by 7
Dong, B., Song, K.-H., Davis, J. L., Zhang, H. F., & Sun, C. (2020) · Advanced Photonics Research · doi:10.1002/adpr.202000038 · Cited by 7
WITHDRAWN: Dual-color MINFLUX: Kinesin-1 takes Chassé-Inchworm stepsPreprint
Scheiderer, L., Wirth, J. O., Tarnawski, M., & Hell, S. W. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.03.05.583551 · Cited by 7
“MINFLUX fluorophore tracking[10, 11] is a comparatively recent but promising addition to the toolbox for measuring conformational changes of proteins.”
Self-citationCD16a pairs form the basal molecular subunit for the NK-cell ADCC lytic synapse
Ross, P. A., Cid, T., Quintero, M. F., Loeffler, J. R., Fatima, H., Leaman, D. P., Matthias, J., Spencer, K. S. R., Zwick, M. B., Henderson, S. C., et al. (2025) · The Journal of Immunology · doi:10.1093/jimmun/vkaf077 · Cited by 6
Cellular optical imaging techniques: a dynamic advancing frontier
Li, Y., Li, C., Zhou, C., Wang, J., Li, W., Pan, T., He, C., Guan, X., Wang, Y., Huang, Y., et al. (2025) · Science China Life Sciences · doi:10.1007/s11427-024-2916-5 · Cited by 6
Seeing the Unseen: Super-Resolution Microscopy in Protein Aggregation Research
Turner, M. J. M., Chen, J., Hatzakis, N. S., & Zhang, M. (2025) · Chemical & Biomedical Imaging · doi:10.1021/cbmi.5c00041 · Cited by 7
Wei, A., Chengbing, 秦. Q., Shuai, 董. D., Xinqin, 孟. M., Yunrui, 宋. S., Xiangdong, 李. L., Xilong, 梁. L., Guofeng, 张. Z., Ruiyun, 陈. C., Jianyong, 胡. H., et al. (2023) · Laser & Optoelectronics Progress · doi:10.3788/lop230749 · Cited by 6
Quantitative Synaptic Biology: A Perspective on Techniques, Numbers and Expectations
Reshetniak, S., Fernández‐Busnadiego, R., Müller, M., Rizzoli, S. O., & Tetzlaff, C. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21197298 · Cited by 6
“This results in a measurement resolution of 1–4 nm in biological samples [87,88], even in multiple color channels [89], and has recently entered the synapse domain (Figure 5A–C).”
BackgroundTheoretical comparison of real-time feedback-driven single-particle tracking techniques
van Heerden, B., & Krüger, T. P. J. (2022) · The Journal of Chemical Physics · doi:10.1063/5.0096729 · Cited by 7
Metadata
- Authors
- Eilers, Y., Ta, H., Gwosch, K. C., Balzarotti, F., & Hell, S. W.
- Affiliations
- Max Planck Institute for Biophysical Chemistry (DE)
- Max Planck Institute for Medical Research (DE)
- Corresponding author
- Hell, Stefan W.
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2018-05-29
- Volume
- 115
- Issue
- 24
- Pages
- 6117-6122
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC6004438
- OpenAlex
- W2806414412
- Cited by
- 188
- References
- 35
- Citations by year
- 2026: 15 · 2025: 24 · 2024: 28 · 2023: 27 · 2022: 30 · 2021: 24 · 2020: 21 · 2019: 17 · 2018: 2
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Max Planck Digital Library (submittedVersion)
- Max Planck Digital Library (submittedVersion, other-oa)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion, cc-by-nc-nd)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- MINFLUX, single-molecule localization, fluorescence nanoscopy, thermal fluctuations, spatiotemporal resolution, single-molecule tracking, fluorophores
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.