Localized cerebral blood flow response at submillimeter columnar resolution
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Functional magnetic resonance imaging (fMRI) has been widely used for imaging brain functions. However, the extent of the fMRI hemodynamic response around the active sites, at submillimeter resolution, remains poorly understood and controversial. With the use of perfusion-based fMRI, we evaluated the hemodynamic response in the cat visual cortex after orientation-specific stimuli. Activation maps obtained by using cerebral blood flow fMRI measurements were predominantly devoid of large draining vein contamination and reproducible at columnar resolution. Stimulus-specific cerebral blood flow responses were spatially localized to individual cortical columns, and columnar layouts were resolved. The periodic spacing of orientation columnar structures was estimated to be 1.1 ± 0.2 mm ( n = 14 orientations, five animals), consistent with previous findings. The estimated cerebral blood flow response at full width at half-maximum was 470 μm under single-stimulus conditions without differential subtraction. These results suggest that hemodynamic-based fMRI can indeed be used to map individual functional columns if large-vessel contributions can be minimized or eliminated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Receptive fields, binocular interaction and functional architecture in the cat’s visual cortex
Hubel, D. H., & Wiesel, T. N. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006837 · Cited by 13,680
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Self-citationMODALITY AND TOPOGRAPHIC PROPERTIES OF SINGLE NEURONS OF CAT'S SOMATIC SENSORY CORTEX
Mountcastle, V. B. (1957) · Journal of Neurophysiology · doi:10.1152/jn.1957.20.4.408 · Cited by 2,400
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
On the Regulation of the Blood‐supply of the Brain
Roy, C. S., & Sherrington, C. S. (1890) · The Journal of Physiology · doi:10.1113/jphysiol.1890.sp000321 · Cited by 1,822
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationRetinotopic organization in human visual cortex and the spatial precision of functional MRI
Engel, S. (1997) · Cerebral Cortex · doi:10.1093/cercor/7.2.181 · Cited by 1,621
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Cited by
What we can do and what we cannot do with fMRI
Logothetis, N. K. (2008) · Nature · doi:10.1038/nature06976 · Cited by 3,612
Representational similarity analysis-connecting the branches of systems neuroscience
Kriegeskorte, N. (2008) · Frontiers in Systems Neuroscience · doi:10.3389/neuro.06.004.2008 · Cited by 3,355
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Self-citationHigh-field fMRI unveils orientation columns in humans
Yacoub, E., Harel, N., & Uğurbil, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804110105 · Cited by 566
Self-citationEmpirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx
Wang, Z., Aguirre, G. K., Rao, H., Wang, J., Fernández-Seara, M. A., Childress, A. R., & Detre, J. A. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.07.003 · Cited by 477
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
“Received 10 July 2008 Revised 6 May 2009 Accepted 14 May 2009 Available online 27 May 2009”
BackgroundMethodSelf-citationNeurometabolic coupling in cerebral cortex reflects synaptic more than spiking activity
Viswanathan, A., & Freeman, R. D. (2007) · Nature Neuroscience · doi:10.1038/nn1977 · Cited by 397
“As technological advances improve the spatial resolution of fMRI, it becomes increasingly important to quantify the relationship between the BOLD signal and the neural activity that it infer”
BackgroundOrigin of Negative Blood Oxygenation Level—Dependent fMRI Signals
Harel, N., Lee, S.-P., Nagaoka, T., Kim, D.-S., & Kim, S.-G. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200208000-00002 · Cited by 369
Self-citationDuong, T. Q., Yacoub, E., Adriany, G., Hu, X., Uǧurbil, K., & Kim, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10472 · Cited by 360
Self-citationNon-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Arterial spin labeling perfusion fMRI with very low task frequency
Wang, J., Aguirre, G. K., Kimberg, D. Y., Roc, A. C., Li, L., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10437 · Cited by 316
“Another possible explanation may lie in the observation that the magnetically labeled blood water is uniformly diffused at the tissue and capillary sites (25,26) and provides more accurate localization than BOLD activation, which depends on tortuous venous vasculature (27).”
BackgroundYacoub, E., Shmuel, A., Logothetis, N., & Uğurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.020 · Cited by 308
Self-citationSpin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10433 · Cited by 308
Self-citationSpatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla
Shmuel, A., Yacoub, E., Chaimow, D., Logothetis, N. K., & Ugurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.030 · Cited by 294
“CBF control does exist in the sub-millimeter scale of columns (Duong et al., 2001; Zhao et al., 2004, 2006).”
BackgroundTechnical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
“It has recently been demonstrated that ASL perfusion fMRI provides equivalent spatial resolution to the ‘initial dip’ for visualizing iso-orientation columns in cat visual cortex (Duong et al., 2001).”
BackgroundLauwers, F., Cassot, F., Lauwers-Cances, V., Puwanarajah, P., & Duvernoy, H. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.024 · Cited by 274
Wang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005) · Radiology · doi:10.1148/radiol.2351031663 · Cited by 271
Analyzing for information, not activation, to exploit high-resolution fMRI
Kriegeskorte, N., & Bandettini, P. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.022 · Cited by 270
Laminar specificity of functional MRI onset times during somatosensory stimulation in rat
Silva, A. C., & Koretsky, A. P. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.222561899 · Cited by 269
In vivo detection of neuroarchitecture in the rodent brain using manganese-enhanced MRI
Aoki, I., Wu, Y.-J. L., Silva, A. C., Lynch, R. M., & Koretsky, A. P. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.031 · Cited by 269
Zhao, F., Wang, P., Hendrich, K., Ugurbil, K., & Kim, S.-G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.013 · Cited by 266
Self-citationSicard, K., Shen, Q., Brevard, M. E., Sullivan, R., Ferris, C. F., King, J. A., & Duong, T. Q. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200304000-00011 · Cited by 263
Self-citationThe future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Ultrahigh field magnetic resonance imaging and spectroscopy
Uğurbil, K., Adriany, G., Andersen, P., Chen, W., Garwood, M., Gruetter, R., Henry, P.-G., Kim, S.-G., Lieu, H., Tkac, I., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.027 · Cited by 252
Self-citationThe Hemo-Neural Hypothesis: On The Role of Blood Flow in Information Processing
Moore, C. I., & Cao, R. (2008) · Journal of Neurophysiology · doi:10.1152/jn.01366.2006 · Cited by 236
“…over the surface of the cortical mantle, which contribute prominently to many imaging techniques, will typically provide artifactually large estimates of the spread of blood delivered to the tissue (Disbrow et al. 2000; Dunn et al. 2005; Duong et al. 2001; Sheth et al. 2004; Vanzetta et al. 2004).”
Representation, Pattern Information, and Brain Signatures: From Neurons to Neuroimaging
Kragel, P. A., Koban, L., Barrett, L. F., & Wager, T. D. (2018) · Neuron · doi:10.1016/j.neuron.2018.06.009 · Cited by 215
Clinical and Macroscopic Correlates of Minicolumnar Pathology in Autism
Casanova, M. F., Buxhoeveden, D. P., & Brown, C. (2002) · Journal of Child Neurology · doi:10.1177/088307380201700908 · Cited by 194
Imaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“…imaging studies conducted on animal models at 9.4 T showing promising results (leading to publications several years later, e.g., (Lee et al., 1999; Duong et al., 2000, 2001; Lee et al., 2002; Harel et al., 2006)), David Rayner and I started discussing the prospect of a high field human system…”
BackgroundInfluentialSelf-citationPhysiological noise reduction for arterial spin labeling functional MRI
Restom, K., Behzadi, Y., & Liu, T. T. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.026 · Cited by 101
“…typically used in fMRI studies, ASL measures have the potential of providing better localization of the sites of neural activity (Luh et al., 2000; Duong et al., 2001) since they reflect the delivery of blood to the capillary beds, whereas BOLD can reflect deoxyhemoglobin in venules that are far…”
BackgroundMethodThe spatial extent of the BOLD response
Saad, Z. S., Ropella, K. M., DeYoe, E. A., & Bandettini, P. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00016-8 · Cited by 78
Perthen, J. E., Bydder, M., Restom, K., & Liu, T. T. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.10.008 · Cited by 32
“Perfusion-based fMRI with arterial spin labeling (ASL) is finding increasing use, in part because perfusion is a fundamental physiological quantity that may provide a more accurate reflection and localization of neural activity as compared to BOLD [5,6].”
Background
Metadata
- Authors
- Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2001-08-28
- Volume
- 98
- Issue
- 19
- Pages
- 10904-10909
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2131996077
- Cited by
- 342
- References
- 37
- FWCI
- 16.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.