Chronic, multisite, multielectrode recordings in macaque monkeys
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A paradigm is described for recording the activity of single cortical neurons from awake, behaving macaque monkeys. Its unique features include high-density microwire arrays and multichannel instrumentation. Three adult rhesus monkeys received microwire array implants, totaling 96–704 microwires per subject, in up to five cortical areas, sometimes bilaterally. Recordings 3–4 weeks after implantation yielded 421 single neurons with a mean peak-to-peak voltage of 115 ± 3 μV and a signal-to-noise ratio of better than 5:1. As many as 247 cortical neurons were recorded in one session, and at least 58 neurons were isolated from one subject 18 months after implantation. This method should benefit neurophysiological investigation of learning, perception, and sensorimotor integration in primates and the development of neuroprosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [340]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davies, D. L., & Bouldin, D. W. (1979) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1979.4766909 · Cited by 9,145
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,123
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Self-citationInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Dynamics of neuronal interactions in monkey cortex in relation to behavioural events
Vaadia, E., Haalman, I., Abeles, M., Bergman, H., Prut, Y., Slovin, H., & Aertsen, A. (1995) · Nature · doi:10.1038/373515a0 · Cited by 812
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
Self-citationDynamic organization of motor control within the olivocerebellar system
Welsh, J. P., Lang, E. J., Suglhara, I., & Llinás, R. (1995) · Nature · doi:10.1038/374453a0 · Cited by 685
Research works printed but not linked: 4
- Evarts, E. V. (1960) Fed. Proc. 19, Suppl. 4, 828–837.
- Davies, D. L. & Bouldin, D. W. (1979) IEEE Trans. Pattern Anal. Machine Intell. 1, 224-227.
- Woolsey, C. N., Settlage, P., Meyer, D. R., Sencer, W., Hamuy, T. P. & Travis, A. M. (1952) Res. Publ. Assoc. Res. Nerv. Ment. Dis. 30, 238-264.
- Mitz, A. R., Godschalk, M. & Wise, S. P. (1991) J. Neurosci. 1, 1855-1872.
Cited by
Items 501–600 of 749
Multi‐Functional Adaptive Interfaces for Next‐Generation Wearable and Implantable Bioelectronics
Park, J., Ha, J., Kim, D. G., Lee, S., Jung, H., Koo, J. H., Cha, G. D., & Kim, D. C. (2026) · Advanced Science · doi:10.1002/advs.202600043 · Cited by 10
“Representative examples from the early 2000s include metal microwire arrays for neural recording and stimulation, as well as implantable cardiac devices, such as ventricular assist systems, constructed with substantial metallic components [ 12–15 ].”
Angelov, S. D., Rehbock, C., Ramesh, V., Heissler, H. E., Alam, M., Barcikowski, S., Schwabe, K., & Krauss, J. K. (2024) · Coatings · doi:10.3390/coatings14030352 · Cited by 8
7.32 Engineering the Neural Interface
Kelly, A., Ballerini, L., Lowery, M. M., & Biggs, M. J. P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.09322-x · Cited by 10
Localization of movable electrodes in a multi-electrode microdrive in nonhuman primates
Premereur, E., Decramer, T., Coudyzer, W., Theys, T., & Janssen, P. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108505 · Cited by 8
Blanco, W., & Ribeiro, S. T. G. (2013) · Revista USP · doi:10.11606/issn.2316-9036.v0i98p17-30 · Cited by 9
Tresco, P. A., & Gerhardt, G. A. (2008) · Springer eBooks · doi:10.1007/978-1-4020-8705-9_3 · Cited by 8
“Indeed, one can find discussions in the peer-reviewed literature that draw attention to performance problems with chronic recording electrode arrays where typically the number of functional recording sites and the quality of signals observed diminish over time (Burns et al., 1974; Liu et al., 1999; Ludwig et al., 2006…”
BackgroundOpen-source automated system for assembling a high-density microwire neural recording array
Massey, T. L., Lee, J. H., Ray, M., Sathe, N., Liu, X., Pister, K. S. J., & Maharbiz, M. M. (2016) · International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS) · doi:10.1109/marss.2016.7561750 · Cited by 9
“Among planar arrays [7], silicon shank Michigan style probes [8], monolithic Utah arrays [9], and microwire arrays [10], the four major classes of neural recording arrays, microwire arrays are”
BackgroundCarter, M. E., & Shieh, J. C. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-374849-2.00004-5 · Cited by 9
IMPROVED FLEXIBLE MICROWIRE ARRAY ELECTRODE FOR INTRACORTICAL SIGNALS RECORDING
Lo, R.-C., & Yu, Y. (2009) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237209001076 · Cited by 8
An Open Source 3-D Printed Modular Micro-Drive System for Acute Neurophysiology
Patel, S. R., Ghose, K., & Eskandar, E. N. (2014) · PLoS ONE · doi:10.1371/journal.pone.0094262 · Cited by 7
“Chronically implanted micro-electrode arrays have also come to the fore as a means of simultaneously recording from populations of neurons [6,7].”
BackgroundBuilding Brain–Machine Interfaces to Restore Neurological Functions
Nicolelis, M. A. L. (2007) · CRC Press eBooks · doi:10.1201/9781420006414-16 · Cited by 7
Self-citationPredicting Spike Trains from PMd to M1 Using Discrete Time Rescaling Targeted GLM
Xing, D., Qian, C., Li, H., Zhang, S., Zhang, Q., Hao, Y., Zheng, X., Wu, Z., Wang, Y., & Pan, G. (2017) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2017.2707466 · Cited by 7
“and the method of Offline Sorter [1] (Plexon Inc.”
BackgroundMethodInfluentialNeurologic Medical Device Overview for Pathologists
Cramer, S. D., Lee, J. S., Butt, M. T., Paulin, J., & Stoffregen, W. C. (2019) · Toxicologic Pathology · doi:10.1177/0192623318816685 · Cited by 7
“…in neurologic medical devices include PEDOT (as mentioned above), sputter-coated iridium oxide (Wilks et al. 2017), polytetrafluoroethylene (teflon; Bijak et al. 2001; Nicolelis et al. 2003), polyimide (Hachmann et al. 2013; Rousche et al. 2001), hydrogels, and polyurethane (Rizzi et al. 2015).”
BackgroundSurgical Techniques for Chronic Implantation of Microwire Arrays in Rodents and Primates
Dimitrov, D. F., & Oliveira, L. (2007) · Frontiers in neuroscience · doi:10.1201/9781420006414.ch2 · Cited by 7
Self-citationSilicon-based wire electrode array for neural interfaces
Pei, W., Zhao, H., Zhao, S., Fang, X., Chen, S., Gui, Q., Tang, R., Chen, Y., Hong, B., Gao, X., et al. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/9/095015 · Cited by 8
“This type of electrode array is composed of flat-end, commercially available, and insulated metal wires [4, 18].”
BackgroundA novel paraplegia model in awake behaving macaques
Krucoff, M. O., Zhuang, K., MacLeod, D. B., Yin, A. S., Byun, Y. W., Manson, R. J., Turner, D. A., Oliveira, L., & Lebedev, M. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00327.2017 · Cited by 7
“…© 2017 the American Physiological Society www.jn.org issues are especially important in high-value (both in monetary cost and time invested) animals with chronic implants that otherwise might be able to generate years of data (Krüger et al. 2010; Nicolelis et al. 2003; Schwarz et al. 2014).”
BackgroundHealthcare Applications of 3D Printing in Human Implants: A Review
Singh, S., Urooj, S., Batra, N., & Kalathil, S. (2020) · IEEE India Conference · doi:10.1109/indicon49873.2020.9342316 · Cited by 7
Bossi, S., Benvenuto, A., Wieringa, P. A., Pino, G. D., Guglielmelli, E., Boretius, T., Stieglitz, T., Navarro, X., & Micera, S. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626831 · Cited by 7
“Silicon [3,4], teflon [ 5 ], epoxy resin [6] or polyimide [7] are the most common biocompatible non-toxic materials employed for development of neural interfaces.”
BackgroundMicroelectrode arrays fabricated using a novel hybrid microfabrication method
Merlo, M. W., Snyder, R. L., Middlebrooks, J. C., & Bachman, M. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9597-4 · Cited by 7
“Two common electrode types are microwire MEAs (Nicolelis et al. 1997; Nicolelis et al. 2003; Schmidt et al. 1976; Williams et al. 1999) and lithographically defined MEAs (Kipke et al. 2003; Mercanzini et al. 2008; Wise et al. 1970).”
BackgroundLee, Y., & Jun, S. B. (2014) · Biomedical Engineering Letters · doi:10.1007/s13534-014-0134-2 · Cited by 7
Chakrabarti, S., Hebert, P. D. N., Wolf, M. T., Campos, M., Burdick, J. W., & Gail, A. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.12.018 · Cited by 7
Invasive Brain–Computer Interfaces for Functional Restoration
Ajiboye, A. B., & Kirsch, R. F. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00027-9 · Cited by 9
In Situ Measurement of Stimulus Induced pH Changes Using ThinFilm Embedded IrOx pH Electrodes
Pfau, J., Ordonez, J. A. L., & Stieglitz, T. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513441 · Cited by 7
“technology of multi-channel recording and stimulation arrays for chronic applications is already at an advanced and well established stage of design and development, many chronic in vivo studies have faced a degeneration in signal stability and in some instances a complete breakdown of a high number of electrode chann…”
BackgroundLee, J., An, B., & Choi, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-90530-x · Cited by 7
Limits of brain–computer interface
Bakay, R. A. E. (2006) · Neurosurgical FOCUS · doi:10.3171/foc.2006.20.5.7 · Cited by 7
Structural and Functional Designs of Advanced Neural Electrodes
Cheng, J., Xiao, M., & Li, Z. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c15407 · Cited by 6
Electrode–Neural Tissue Interactions: Immune Responses, Current Technologies, and Future Directions
Kim, G. B., Fattahi, P., & Abidian, M. R. (2013) · Wiley eBooks · doi:10.1002/9783527649600.ch19 · Cited by 6
MEMS-based microelectrode technologies capable of penetrating neural tissues
Chou, N., Byun, D., & Kim, S. (2014) · Biomedical Engineering Letters · doi:10.1007/s13534-014-0133-3 · Cited by 7
“Since then, metal wires in diameters of 2580 μm have been used as neural electrodes, which are made of stainless steel [32-34], tungsten [35], platinum [36], gold”
BackgroundMethodZhu, Y., Yang, Y., Ni, G., Li, S., Liu, W., Gao, Z., Zhang, X., Zhang, Q., Wang, C., & Zhou, J. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1284927 · Cited by 6
Flexible Electrode for Implantable Neural Devices
Tsang, W. M., & Je, M. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_6 · Cited by 6
Aguiar, L. A. A., de Vasconcelos, N. A. P., Tunes, G. C., Fontenele, A. J., Nogueira, R. D. A., Reyes, M. B., & Carelli, P. V. (2020) · HardwareX · doi:10.1016/j.ohx.2020.e00132 · Cited by 6
Boosted and Linked Mixtures of HMMs for Brain-Machine Interfaces
Darmanjian, S., & Príncipe, J. C. (2008) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2008/216453 · Cited by 6
“For the rat experiment, the dataset consists of 13000 × 16 time bins [1, 7].”
BackgroundMethodWarwick, K. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-373932-2.00028-4 · Cited by 6
Near field non-invasive electrophysiology of retrotrapezoid nucleus using amperometric cation sensor
Gupta, S., Otero, J. J., Sundaresan, V.-B., & Czeisler, C. M. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111975 · Cited by 5
Piozin, C., Altamira, G. H., Simon, C., Lavrard, B., Audran, J.-Y., Waszak, F., & Eskiizmirliler, S. (2022) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/bci53720.2022.9734823 · Cited by 6
Dong, T., Chen, L., Patel, P. R., Richie, J. M., Chestek, C. A., & Shih, A. J. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acd279 · Cited by 5
Mathematical modeling of chemotaxis and glial scarring around implanted electrodes
Silchenko, A. N., & Tass, P. A. (2015) · New Journal of Physics · doi:10.1088/1367-2630/17/2/023009 · Cited by 5
Determination of the arm orientation for brain-machine interface prosthetics
Clanton, S. T., Laws, J., & Matsuoka, Y. (2006) · IEEE RO-MAN · doi:10.1109/roman.2005.1513815 · Cited by 5
Zhuang, L., Guo, T., & Zhang, B. (2015) · Springer eBooks · doi:10.1007/978-94-017-7333-1_9 · Cited by 6
Single Neurons and Primate Behavior
Wurtz, R. H., & Sommer, M. A. (2006) · The MIT Press eBooks · doi:10.7551/mitpress/4576.003.0007 · Cited by 5
“One method of obtaining these multiple recordings is to insert chronic wire electrodes into the brain (see deCharms, Blake, and Merzenich, 1999; Nicolelis et al., 2003), and this has been used to compare activity between areas along the somatosensory pathway (see, for example, Faggin et al.”
MethodA neural recording amplifier based on adaptive SNR optimization technique for long-term implantation
Lee, T., Jang, D., Jung, Y., Jeon, H., Hong, S., Han, S., Chu, J., Lee, J., & Je, M. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325150 · Cited by 5
“In most cases, however, the signal-to-noise ratio (SNR) of the recorded neural signal degrades significantly over several months after implantation, even though the systems work well initially [1].”
BackgroundVisual epidural field potentials possess high functional specificity in single trials
Fischer, B., Schander, A., Kreiter, A. K., Lang, W., & Wegener, D. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00510.2019 · Cited by 6
Multielectrode Recording in Behaving Monkeys
Crist, R. E., & Lebedev, M. (2007) · Frontiers in neuroscience · doi:10.1201/9781420006414.ch9 · Cited by 5
Self-citationNadin, M. (2006) · Springer eBooks · doi:10.1007/3-540-28611-x_2 · Cited by 6
“1. The “mind” driving the machine (see the experiments, so far performed with monkeys [ 26 ]), which avoids the “bottleneck” of current user interfaces, which are notoriously asynchronic.”
BackgroundLeblois, A., & Pouzat, C. (2017) · Wiley eBooks · doi:10.1002/9781118873397.ch3 · Cited by 5
Thin-Film Microelectrode Arrays for Biomedical Applications
Cheung, K. C. (2010) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_6 · Cited by 5
“They are extremely robust and have demonstrated recording ability for more than 18 months [ 11 ] (Fig. 2). One commonly used configuration is the tetrode, which comprises a bundle of four wires [12].”
BackgroundInfluentialBrain–machine interfaces and transcranial stimulation
Carmena, J. M., & Cohen, L. G. (2012) · Handbook of clinical neurology · doi:10.1016/b978-0-444-52137-8.00027-9 · Cited by 4
“Thus far, studies have reported high quality recordings up to 18 months after surgery (Nicolelis et al., 2003).”
BackgroundSelf-citationNeural circuits and in vivo monitoring using diamond
Fox, K. E., & Prawer, S. (2014) · Elsevier eBooks · doi:10.1533/9780857096685.2.291 · Cited by 4
Lee, H. C., Gaire, J., McDowell, S. P., & Otto, K. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943629 · Cited by 5
Badi, M., Borgognon, S., O’Doherty, J. E., & Shokur, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00008-3 · Cited by 5
Experimental enhancement of neurphysiological function
Deca, D., & Koene, R. A. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00189 · Cited by 4
“…have enabled control of prosthetic limbs through chronic multi-site neural interfaces in non-human primates (Nicolelis, 2001; Graziano et al., 2002; Nicolelis et al., 2003; Gilja et al., 2012) and human experiments with implantable devices that enable control of a cursor, a wheel chair, a TV…”
BackgroundSurgeon responsibility in the era of “outrageous science”
Satava, R. M. (2006) · Surgical Endoscopy · doi:10.1007/s00464-006-0799-4 · Cited by 4
“A number of universities have performed research with implantation of a ‘‘chip’’ (BrainGate is the commercial product) into the motor strip of a monkey s brain to record its ‘‘thoughts’’ [10].”
BackgroundMiyakawa, N., Katsumata, N., Blake, D. T., Merzenich, M. M., & Tanifuji, M. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.08.019 · Cited by 4
“Multiple electrode arrays are only the available technique so far to investigate population neural activities with high temporal and spatial resolution (Blake and Merzenich, 2002; deCharms et al., 1999; Nicolelis et al., 2003; Hochberg et al., 2006).”
BackgroundStieglitz, T. (2012) · Cambridge University Press eBooks · doi:10.1017/cbo9780511979958.002 · Cited by 4
Hidden Markov Models Predict the Future Choice Better Than a PSTH-Based Method
Marcos, E., Londei, F., & Genovesio, A. (2019) · Neural Computation · doi:10.1162/neco_a_01216 · Cited by 4
“New recording techniques allow for the simultaneous recording of much larger numbers of neurons, in some cases up to hundreds of neurons and across several brain regions (Dotson, Hoffman, Goodell, & Gray, 2017; Nicolelis et al., 2003).”
BackgroundSomatosensory cortex of macaque monkeys is designed for opposable thumb
Lazar, L., Chand, P., Rajan, R., Mohammed, H., & Jain, N. (2022) · Cerebral Cortex · doi:10.1093/cercor/bhac061 · Cited by 4
Brain-machine interfaces as the new frontier in extreme miniaturization
Rabaey, J. M. (2011) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2011.6044909 · Cited by 4
Therapeutic potential of computer to cerebral cortex implantable devices
Warwick, K., Gasson, M. N., & Spiers, A. J. (2007) · Springer eBooks · doi:10.1007/978-3-211-33081-4_61 · Cited by 4
“from the same set of implanted electrodes [3, 16].”
BackgroundYu, Y., & Lo, R.-C. (2010) · Journal of the Chinese Institute of Engineers · doi:10.1080/02533839.2010.9671595 · Cited by 4
“The wires are cut to suitable length with sharp surgical scissors, exposing a single recording surface per wire (Nicolelis et al., 2003).”
BackgroundChhatbar, P. Y., & Francis, J. T. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626832 · Cited by 4
The jobs of others: “speculative interdisciplinarity” as a pitfall for impact analysis
Rader, M. (2012) · Journal of Information Communication and Ethics in Society · doi:10.1108/14779961211210621 · Cited by 7
Wang, Y., Sanchez, J. C., Príncipe, J. C., Mitzelfelt, J. D., & Gunduz, A. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260516 · Cited by 4
Spatial-Temporal Clustering of Neural Data Using Linked-Mixtures of Hidden Markov Models
Darmanjian, S., & Príncipe, J. C. (2010) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2009/892461 · Cited by 4
“Overlaid in blue is the original angular tunings of some of the neurons.”
BackgroundMethodA stimulus-dependent connectivity analysis of neuronal networks
Nykamp, D. Q. (2008) · Journal of Mathematical Biology · doi:10.1007/s00285-008-0224-9 · Cited by 4
“There is also a large literature focused on analyzing interactions among neurons [1,4,5,7,9–11,16,17,19–21,25,27].”
BackgroundMicera, S., Carpaneto, J., Umiltà, M. A., Rochat, M. J., Escola, L., Gallese, V., Carrozza, M. C., Krueger, J., Rizzolatti, G., & Dario, P. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419572 · Cited by 4
“The first eight PCs usually accounted for more than 80% of the variance of the waveforms accordingly to [15].”
BackgroundXiao, D., & Hu, J. (2008) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2008.880 · Cited by 4
“A brain–computer interface is a way of using an individual’s thought processes to control computer or electromechanical hardware without using overt muscle activities [1-3].”
BackgroundSystem and Circuit Design for Biologically-Inspired Intelligent Learning
Temel, T. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-018-1 · Cited by 4
Independently Coupled HMM Switching Classifier for a Bimodel Brain-Machine Interface
Darmanjian, S., Kim, S.-P., Nechyba, M. C., Príncipe, J. C., Wessberg, J., & Nicolelis, M. (2006) · Machine learning for signal processing ... · doi:10.1109/mlsp.2006.275579 · Cited by 4
“Within the neurological community, the question of whether the motor cortex encodes the arm's velocity, position, or other kinematic encodings (joint angle, muscle activity, muscle synergy, etc), continues to be debated [8, 13, 11].”
BackgroundSelf-citationHasan, M. N., Radwan, A. N., Kim, M., Kucukal, E., Maji, D., Pashaei, V., Chung, C.-Y., Kakkar, A., & Gurkan, U. A. (2019) · TECHNOLOGY · doi:10.1142/s2339547819300014 · Cited by 4
Building Brain–Machine Interfaces to Restore Neurological Functions
Crist, R. E., Lebedev, M., & Nicolelis, M. A. L. (2007) · Frontiers in neuroscience · doi:10.1201/9781420006414.ch11 · Cited by 7
Self-citationEstimation of neural energy in microelectrode signals
Gaumond, R. P., Clement, R. S., Silva, R., & Sander, D. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/3/001 · Cited by 4
Long-term cortical recordings with microactuated microelectrodes
Jackson, N., Stice, P., Okandan, M., & Muthuswamy, J. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369632 · Cited by 5
Implanted intracortical electrodes as chronic neural interfaces to the central nervous systemPreprint
Henderson, P. (2015) · doi:10.7287/peerj.preprints.1255v1 · Cited by 5
“performed a study of in vivo implantation of low-density microwire arrays and found that viability ranged from 3 months to greater than 18 months [78].”
BackgroundInvasive Brain Signal Acquisition Techniques: SUA, MUA, LFP, ECoG in Neuroimaging and Recording
Chaudhary, U. (2025) · Springer eBooks · doi:10.1007/978-3-031-76081-5_3 · Cited by 3
Li, M., Zhang, X., He, Q., Chen, D., Chen, F., Wang, X., Sun, S., Sun, Y., Li, Y., Zhu, Z., et al. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.800159 · Cited by 5
“Putative spike activity was isolated with previously described spike sorting procedures (Nicolelis et al., 2003; Isomura et al., 2009; Kaufman et al., 2013; Saiki et al., 2014; Wang et al., 2016; Li et al., 2021).”
MethodSankar, R. T., & Li, K. (2010) · Digital Commons - University of South Florida (University of South Florida) · Cited by 4
Neurointerfaces: Review and development
Rechkunov, S. N., Prinz, A. V., Seleznev, V. A., Golod, S. V., Soots, R. A., Ivanov, A. I., Ratushnyak, A. S., & Prinz, V. Y. (2015) · Russian Journal of Genetics Applied Research · doi:10.1134/s2079059715060143 · Cited by 3
“High density MEA devices make it pos sible to record simultaneously the activity of dozens of neurons in the ensemble at the cellular level (Nicolelis et al., 2003; Schwartz, 2004).”
BackgroundTetrODrive: an open-source microdrive for combined electrophysiology and optophysiology
Brosch, M., Vlasenko, A., Ohl, F. W., & Lippert, M. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf608 · Cited by 4
Mejoras cognitivas y el problema de la inequidad: entre bioconservadurismo y bioliberalismo
López‐Silva, P. (2021) · Persona y Derecho · doi:10.15581/011.84.009 · Cited by 3
State-dependent complexity of the local field potential in the primary visual cortex
Jungmann, R. M., Feliciano, T., Aguiar, L. A. A., Soares‐Cunha, C., Coimbra, B., Rodrigues, A. J., Copelli, M., Matias, F. S., de Vasconcelos, N. A. P., & Carelli, P. V. (2024) · Physical review. E · doi:10.1103/physreve.110.014402 · Cited by 6
Neural Ensemble Recordings from Central Gustatory-Reward Pathways in Awake and Behaving Animals
Simon, S. A., Nicolelis, M. A. L., & Oliveira-Maia, A. J. (2007) · Frontiers in neuroscience · doi:10.1201/9781420006414.ch10 · Cited by 3
Self-citationAssessing Spike Sorting contribution to neural implant reliability
Furno, L., Rigosa, J., Panarese, A., & Micera, S. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696210 · Cited by 3
A computational model of early visual cortex using konio-cellular pathway projections
Rao, A. R., & Xiao, Y. (2012) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2012.6252425 · Cited by 3
“In order to obtain a larger number of measurements, either multi-electrode arrays [12] or twophoton calcium imaging methods [37] may be used.”
MethodDesign and analysis of generative models for brain machine interfaces
Darmanjian, S. (2009) · Cited by 3
Comparison of Three Motor Imagery EEG Signal Processing Methods
Xiao, D. (2011) · Advances in intelligent and soft computing · doi:10.1007/978-3-642-25986-9_79 · Cited by 4
Nanotechnologies for the Bioelectronic Interface
Avants, B. W., Park, H., & Robinson, J. T. (2016) · Wiley eBooks · doi:10.1002/9783527801312.ch6 · Cited by 3
Controlling Attention with Neurofeedback
Ordikhani-Seyedlar, M., & Lebedev, M. (2017) · Springer series in cognitive and neural systems · doi:10.1007/978-3-319-29674-6_25 · Cited by 3
Issues Impairing the Success of Neural Implant Technology
Spiers, A. J., Warwick, K., Gasson, M. N., & Ruiz, V. (2006) · Applied Bionics and Biomechanics · doi:10.1155/2006/154724 · Cited by 6
SiC for Brain–Machine Interface (BMI)
Frewin, C. L., Abbati, L., Weeber, E. J., & Saddow, S. E. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-385906-8.00007-6 · Cited by 3
Nanoelectronics for Neuroscience
Rastogi, S. K., & Cohen‐Karni, T. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99893-3 · Cited by 3
Fares, H., Ronchini, M., Zamani, M., Farkhani, H., Chiappalone, M., Neftci, E., & Moradi, F. (2026) · npj Biomedical Innovations. · doi:10.1038/s44385-026-00074-w · Cited by 2
“Yet, rigid probes may lead to tissue damage and in fl ammation, which may degrade the recorded neural signal 82 .”
A model design of a 2560-channel neural spike detection platform
Elaraby, N., & Obeid, I. (2012) · International Conference on ReConFigurable Computing and FPGAs (ReConFig) · doi:10.1109/reconfig.2012.6416762 · Cited by 2
A Biomimetic Adaptive Algorithm and Micropower Circuit Architecture for Implantable Neural Decoders
Rapoport, B. I., & Sarpeshkar, R. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-018-1.ch010 · Cited by 3
Neural correlates of learning in a linear discriminant analysis brain-computer interface paradigm
Lo, Y. T., Premchand, B., Libedinsky, C., & So, R. Q. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac985f · Cited by 2
“BCI systems only sample a very small subpopulation of this complex network of neurons, commonly those in the primary motor cortex (M1) and sometimes the supplementary motor area [8, 9].”
BackgroundОрлов, А. А., & Филатова, Е. В. (2011) · Neuroscience and Behavioral Physiology · doi:10.1007/s11055-011-9540-4 · Cited by 2
Brain Computer Interface (BCI) Tools Developed in a Clinical Environment
Anderson, N., & DeVries, E. M. (2010) · American Journal of Electroneurodiagnostic Technology · doi:10.1080/1086508x.2010.11079773 · Cited by 2
“Developed largely in parallel to the EEG interfaces, microelectrodes, which are, surgically placed directly into the brain tissue, have proven to be a successful recording modality for BCis as well (Fetz and Finocchio 1971, Schwartz et al. 1988, Georgopoulos 1995, Nicolelis et al. 2003).”
MethodDeveloping Chitosan-based Biomaterials for Brain Repair and Neuroprosthetics
Cao, Z. H. (2010) · Cited by 3
Neural Interfaces: from Human Nerves to Electronics
Falcone, J., Birjiniuk, J., Kretschmar, R., & Bellamkonda, R. V. (2014) · Wiley eBooks · doi:10.1002/9783527673148.ch6 · Cited by 2
Chronic Recordings in Transgenic Mice
Nicolelis, M. A. L. (2007) · CRC Press eBooks · doi:10.1201/9781420006414-10 · Cited by 2
Self-citationNanograss Boron Doped Diamond microelectrode arrays for recording and stimulating neuronal tissues
Kiran, R., Cottance, M., Joucla, S., Rousseau, L., Bongrain, A., Yvert, B., Scorsone, E., Bendali, A., Lissorgues, G., Picaud, S. A., et al. (2013) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2013.6626874 · Cited by 2
Metadata
- Authors
- Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P.
- Affiliations
- Duke University (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-09-05
- Volume
- 100
- Issue
- 19
- Pages
- 11041-11046
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC196923
- OpenAlex
- W2095504054
- Cited by
- 740
- References
- 28
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 13 · 2023: 12 · 2022: 28 · 2021: 24 · 2020: 28 · 2019: 31 · 2018: 26 · 2017: 31 · 2016: 26 · 2015: 39 · 2014: 49 · 2013: 45 · 2012: 36
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Hispana (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- single-unit recording, macaque, rhesus monkeys, microwire arrays, multi-electrode recording, cortical neurons, neuroprosthetics, sensorimotor integration
- MeSH terms
- Action Potentials, Animals, Cerebral Cortex, Electrodes, Female, Macaca mulatta, Male
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.