Chronic, multisite, multielectrode recordings in macaque monkeys
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A paradigm is described for recording the activity of single cortical neurons from awake, behaving macaque monkeys. Its unique features include high-density microwire arrays and multichannel instrumentation. Three adult rhesus monkeys received microwire array implants, totaling 96–704 microwires per subject, in up to five cortical areas, sometimes bilaterally. Recordings 3–4 weeks after implantation yielded 421 single neurons with a mean peak-to-peak voltage of 115 ± 3 μV and a signal-to-noise ratio of better than 5:1. As many as 247 cortical neurons were recorded in one session, and at least 58 neurons were isolated from one subject 18 months after implantation. This method should benefit neurophysiological investigation of learning, perception, and sensorimotor integration in primates and the development of neuroprosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [340]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davies, D. L., & Bouldin, D. W. (1979) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1979.4766909 · Cited by 9,145
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,123
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Self-citationInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Dynamics of neuronal interactions in monkey cortex in relation to behavioural events
Vaadia, E., Haalman, I., Abeles, M., Bergman, H., Prut, Y., Slovin, H., & Aertsen, A. (1995) · Nature · doi:10.1038/373515a0 · Cited by 812
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
Self-citationDynamic organization of motor control within the olivocerebellar system
Welsh, J. P., Lang, E. J., Suglhara, I., & Llinás, R. (1995) · Nature · doi:10.1038/374453a0 · Cited by 685
Research works printed but not linked: 4
- Evarts, E. V. (1960) Fed. Proc. 19, Suppl. 4, 828–837.
- Davies, D. L. & Bouldin, D. W. (1979) IEEE Trans. Pattern Anal. Machine Intell. 1, 224-227.
- Woolsey, C. N., Settlage, P., Meyer, D. R., Sencer, W., Hamuy, T. P. & Travis, A. M. (1952) Res. Publ. Assoc. Res. Nerv. Ment. Dis. 30, 238-264.
- Mitz, A. R., Godschalk, M. & Wise, S. P. (1991) J. Neurosci. 1, 1855-1872.
Cited by
Items 301–400 of 749
High‐density implantable neural electrodes and chips for massive neural recordings
Wang, L., Suo, Y., Wang, J., Wang, X., Xue, K., An, J., Sun, X., Chen, Q., Tang, X., Zhao, Y., et al. (2024) · Brain‐X · doi:10.1002/brx2.65 · Cited by 36
Sub-meninges implantation reduces immune response to neural implants
Markwardt, N. T., Stokol, J., & Rennaker II, R. L. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.01.020 · Cited by 33
“This is similar to materials which have been used to construct microwire recording arrays (Nicolelis et al., 2003; Williams et al., 1999).”
MethodParalikar, K. J., & Clement, R. S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923150 · Cited by 35
“These include hand-fabricated microwire designs [2], [ 3 ], micromachined arrays [4], [5], and planar thin-film structures with multiple recording sites along the shanks [6]–[8].”
MethodEnhancing biocompatibility of the brain-machine interface: A review
Villa, J., Cury, J., Kessler, L., Tan, X., & Richter, C. (2024) · Bioactive Materials · doi:10.1016/j.bioactmat.2024.08.034 · Cited by 45
“Following the implantation of the BMI, micromotions between the implanted devices and the neural tissue may occur from differences in Young ’ s modulus and lead to tissue reactions, limiting biocompatibility and affecting performance [6 – 8].”
MethodMagnetically Inserted Neural Electrodes: Tissue Response and Functional Lifetime
Dryg, I. D., Ward, M. P., Qing, K. Y., Mei, H., Schaffer, J. E., & Irazoqui, P. P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2399856 · Cited by 32
Stochastic Facilitation of Artificial Tactile Sensation in Primates
Medina, L. E., Lebedev, M., O’Doherty, J. E., & Nicolelis, M. A. L. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.3115-12.2012 · Cited by 34
“Two rhesus monkeys, M (male) and N (female), were chronically implanted with cortical stainless steel microelectrode arrays in M1 and S1 in both hemispheres (Nicolelis et al., 2003) (Fig.”
MethodSelf-citationHypoxia-Ischemia Disrupts Directed Interactions within Neonatal Prefrontal-Hippocampal Networks
Brockmann, M. D., Kukovic, M., Schönfeld, M. H., Sedlacik, J., & Hanganu‐Opatz, I. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0083074 · Cited by 37
“As detailed previously [48] the stored signals were”
BackgroundPolikov, V. S., Su, E. C., Ball, M. A., Hong, J., & Reichert, W. M. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.05.002 · Cited by 33
“Most neural recording arrays fail to record the adequate number of high signal to noise ratio unit potentials necessary to generate a control signal after several weeks to months (Rousche and Normann, 1998;Williams et al., 1999;Liu et al., 1999;Nicolelis et al., 2003;Schwartz, 2004).”
BackgroundObaid, A., Hanna, M.-E., Huang, S.-W., Hu, Y.-T., Jáidar, O., Nix, W. D., Ding, J., Melosh, N. A., & Wu, Y. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2529147123 · Cited by 34
Transmission Latencies in a Telemetry-Linked Brain-Machine Interface
Bossetti, C. A., Carmena, J. M., Nicolelis, M. A. L., & Wolf, P. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827090 · Cited by 33
Self-citationA bio-friendly and economical technique for chronic implantation of multiple microelectrode arrays
Chhatbar, P. Y., von Kraus, L. M., Semework, M., & Francis, J. T. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.02.006 · Cited by 32
Horiuchi, H., Agetsuma, M., Ishida, J., Nakamura, Y., Cheung, D. L., Nanasaki, S., Kimura, Y., Iwata, T., Takahashi, K., Sawada, K., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-14571-y · Cited by 32
He, W. J., & Bellamkonda, R. V. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.pt4 · Cited by 34
A novel multisite silicon probe for high quality laminar neural recordings
Grand, L., Pongracz, A., Vázsonyi, É. B., Márton, G., Gubán, D., Fiáth, R., Kerekes, B. P., Karmos, G., Ulbert, I., & Battistig, G. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.12.019 · Cited by 33
Classification of Motor Imagery EEG Signals Based on Energy Entropy
Xiao, D., Mu, Z., & Hu, J. (2009) · International Symposium on Intelligent Ubiquitous Computing and Education (IUCE) · doi:10.1109/iuce.2009.57 · Cited by 34
“A brain–computer interface is a way of using an individual’s thought processes to control computer or electromechanical hardware without using overt muscle activities [1-3].”
BackgroundFiáth, R., Beregszászi, P., Horváth, D., Wittner, L., Aarts, A. A. A., Ruther, P., Neves, H. P., Bokor, H., Acsády, L., & Ulbert, I. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00318.2016 · Cited by 33
“…monitor the activity of hundreds of neurons simultaneously both in anesthetized and in freely moving animals (Berényi et al. 2014; Ifft et al. 2013; Nicolelis et al. 2003; Vandecasteele et al. 2012), which is fundamental for the understanding of complex neuronal computations and higher order…”
BackgroundLearning Mappings in Brain Machine Interfaces with Echo State Networks
Rao, Y. N., Kim, S.-P., Sanchez, J. C., Deniz Erdogmus, B., Príncipe, J. C., Carmena, J. M., Lebedev, M., & Nicolelis, M. A. L. (2005) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2005.1416283 · Cited by 32
“Microwire electrode arrays [13] were chronically implanted in the dorsal premotor cortex, supplementary motor area, primary motor cortex and primary somatosensory cortex of an adult female monkey while performing a hand-reaching task.”
BackgroundSelf-citationPhouphetlinthong, O., Partiot, E., Bernou, C., Sebban, A., Gaudin, R., & Charlot, B. (2023) · Lab on a Chip · doi:10.1039/d3lc00294b · Cited by 33
Transistor needle chip for recording in brain tissue
Felderer, F., & Fromherz, P. (2011) · Applied Physics A · doi:10.1007/s00339-011-6392-2 · Cited by 31
Kübler, A. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374168-4.00017-4 · Cited by 34
Bioactive anti‐inflammatory coating for chronic neural electrodes
Taub, A. H., Hogri, R., Magal, A., Mintz, M., & Shacham‐Diamand, Y. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34152 · Cited by 35
Bayesian machine learning applied in a brain-computer interface for disabled users
Hoffmann, U. (2007) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-3924 · Cited by 38
Optimizing the automatic selection of spike detection thresholds using a multiple of the noise level
Rizk, M., & Wolf, P. D. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0451-2 · Cited by 34
“Voltage thresholding is used widely to perform neural spike detection in many different contexts [9,11,14,15,17,18,19,23,26,29,30,31,32,33,35,36,37,40,41].”
MethodPlasticity of Fear and Safety Neurons of the Amygdala in Response to Fear Extinction
Sangha, S. (2015) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2015.00354 · Cited by 31
“High J3 values and low DB values are indicative of good single unit isolation (Davies and Bouldin, 1979; Nicolelis et al., 2003; Herry et al., 2008; Sangha et al., 2013).”
Dunlap, C. F., Colachis, S. C., Meyers, E., Bockbrader, M. A., & Friedenberg, D. A. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.558987 · Cited by 33
Bioactive polymer-enabled conformal neural interface and its application strategies
Hu, Z., Niu, Q., Hsiao, B. S., Yao, X., & Zhang, Y. (2023) · Materials Horizons · doi:10.1039/d2mh01125e · Cited by 30
Carbon‐Nanotube‐Modified Electrodes for Highly Efficient Acute Neural Recording
Shin, J. H., Kim, G. B., Lee, E. J., An, T., Shin, K., Lee, S. E., Choi, W., Lee, S., Latchoumane, C.-F. V., Shin, H., et al. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300183 · Cited by 31
Functional and Histological Effects of Chronic Neural Electrode Implantation
Sahyouni, R., Chang, D. T., Moshtaghi, O., Mahmoodi, A., Djalilian, H. R., & Lin, H. W. (2017) · Laryngoscope Investigative Otolaryngology · doi:10.1002/lio2.66 · Cited by 33
“Other coatings that decrease the inflammatory response include a variety of inert compounds, including Teflon, which has been shown to reduce the immune response to wire electrode implants in rat(51) and monkey cortex.(52) More recently, Rousche et al.”
BackgroundObaid, A., Wu, Y., Hanna, M., Nix, W. D., Ding, J., & Melosh, N. A. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/454520 · Cited by 31
Lifetime engineering of bioelectronic implants with mechanically reliable thin film encapsulations
Niemiec, M., & Kim, K. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0b19 · Cited by 32
Neural vs Neuromorphic Interfaces: Where Are We Standing?
Rana, D., Babushkina, N., Gini, M., Cáceres, A., Li, H., Maybeck, V., Criscuolo, V., Mayer, D., Ienca, M., Musall, S., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00862 · Cited by 30
Cho, Y. K., Zheng, G., Augustine, G. J., Hochbaum, D. R., Cohen, A. E., Knöpfel, T., Pisanello, F., Pavone, F. S., Vellekoop, I. M., Booth, M. J., et al. (2016) · Journal of Optics · doi:10.1088/2040-8978/18/9/093007 · Cited by 29
Soft tissue reactions evoked by implanted gallium phosphide
Linsmeier, C. E., Wallman, L., Faxius, L., Schouenborg, J., Bjursten, L. M., & Danielsen, N. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.08.028 · Cited by 30
Single trial neuronal activity dynamics of attentional intensity in monkey visual area V4
Ghosh, S., & Maunsell, J. H. R. (2021) · Nature Communications · doi:10.1038/s41467-021-22281-2 · Cited by 35
Electrothermal Microactuators With Peg Drive Improve Performance for Brain Implant Applications
Anand, S., Sutanto, J., Baker, M. S., Okandan, M., & Muthuswamy, J. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2012.2203789 · Cited by 30
“The longevity of current microelectrode implants in the brain is highly variable [18], [19], and there is significant degradation in neural signal quality after a few weeks of implantation [20], [21].”
BackgroundPowering mm-Size Wireless Implants for Brain-Machine Interfaces
Michael, M. (2011) · UC Berkeley · Cited by 30
Rennaker, R. L., Ruyle, A. M., Street, S. E., & Sloan, A. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.07.018 · Cited by 35
“Second, the use of low i nnector on a DIP socket s s. Electrodes w r 6 weeks.”
BackgroundMethodLuczak, A., & Narayanan, N. S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.009 · Cited by 28
“nally, as ensemble recordings gain in popularity, spike sorting becomes a limiting step in the analysis of neuronal data, particularly when several hundred neurons are recorded in a single experiment [17]. Here, we propose a new method for the analysis of extracellularly recorded neuronal ensemble data, which does not…”
Methodde Kamps, M., Baier, V., Drever, J., Dietz, M., Mösenlechner, L., & van der Velde, F. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.07.006 · Cited by 36
“Technological advances have allowed the development of novel ways of connecting electronic readout to neurons, leading to bigger multi-electrode arrays (MEAs) (Nicolelis et al., 2003; Navarro et al., 2005) or to neuron-on-silico chips (Fromherz, 2003; Schoen & Fromherz, 2007).”
Flexible Polymer Electrodes for Stable Prosthetic Visual Perception in Mice
Orlemann, C., Boehler, C., Kooijmans, R. N., Li, B., Asplund, M., & Roelfsema, P. R. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202304169 · Cited by 27
Santos, L. M., Opriș, I. C., Fuqua, J. L., Hampson, R. E., & Deadwyler, S. A. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.01.006 · Cited by 27
“…processor (MAP Spike Sorter by Plexon, Inc. Dallas, TX) was employed for tetrode and hexatrode wire recordings with statistical cluster dissection principal component analysis (PCA) in 2D/ 3D via standard parametric multivariate analyses of variance (MANOVA) procedures (Nicolelis et al., 2003).”
MethodInfluentialCao, Y., & He, W. J. (2010) · Biomacromolecules · doi:10.1021/bm100095t · Cited by 29
Galashan, F. O., Rempel, H. C., Meyer, A., Gruber-Dujardin, E., Kreiter, A. K., & Wegener, D. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00508.2010 · Cited by 30
Ultra-long term stability of single units using chronically implanted multielectrode arrays
Vaidya, M., Dickey, A. S., Best, M. D., Coles, J., Balasubramanian, K., Suminski, A. J., & Hatsopoulos, N. G. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944715 · Cited by 27
“Initial attempts to track neurons involved visually inspecting the waveform shape across days [1], by computing the correlation between average waveforms [2], or by comparing the clustering in principal component space [3].”
Biomimetic Sensors for the Senses: Towards Better Understanding of Taste and Odor Sensation
Wu, C., Du, Y.-W., Huang, L., Shoshan-Galeczki, Y. B., Dagan‐Wiener, A., Naim, M., Niv, M. Y., & Wang, P. (2017) · Sensors · doi:10.3390/s17122881 · Cited by 30
“In addition, in vivo biosensing approaches have been able to perform continuous extracellular recordings for up to 18 months [113,114].”
BackgroundA new planar multielectrode array: recording from a rat auditory cortex
Tsytsarev, V., Taketani, M., Schottler, F., Tanaka, S., & Hara, M. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/006 · Cited by 26
“The cranium above the auditory cortex was removed (Sally and Kelly 1988) using a dental drill, the dura mater was also removed (Nicolelis and Ribeiro 2002, Nicolelis et al 2003, Knerom et al 2000, Kudrimoti et al 1999).”
MethodDistinct neural patterns enable grasp types decoding in monkey dorsal premotor cortex
Hao, Y., Zhang, Q., Controzzi, M., Cipriani, C., Li, Y., Li, J., Zhang, S., Wang, Y., Chen, W., Carrozza, M. C., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066011 · Cited by 28
“Neural spikes from each electrode were resorted using commercial software (Offline Sorter, Plexon, USA) session by session to isolate single units [22].”
MethodOpriș, I. C., Fuqua, J. L., Gerhardt, G. A., Hampson, R. E., & Deadwyler, S. A. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.05.029 · Cited by 27
Zhang, H., Vecchio, D. A., Emre, A. E., Rahmani, S., Cheng, C., Zhu, J. G., Misra, A. C., Lahann, J., & Kotov, N. A. (2021) · MRS Bulletin · doi:10.1557/s43577-021-00071-x · Cited by 27
Fear learning induces synaptic potentiation between engram neurons in the rat lateral amygdala
Abatis, M., Perin, R., Niu, R., van den Burg, E., Hegoburu, C., Kim, R., Okamura, M., Bito, H., Markram, H., & Stoop, R. (2024) · Nature Neuroscience · doi:10.1038/s41593-024-01676-6 · Cited by 29
“For further confirmation, we also measured cluster stability across recording sessions using J3 and Davies–Bouldin statistics 59,60 .”
InfluentialIfft, P. J., Lebedev, M., & Nicolelis, M. A. L. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00016 · Cited by 26
“…stage of the BMI field, up to several hundred neurons in the brain can be recorded simultaneously by chronically implanted multielectrode arrays (Nicolelis et al., 2003; Chapin, 2004; Churchland et al., 2007; Miller and Wilson, 2008; Lebedev and Nicolelis, 2011; Lebedev et al., 2011; Stevenson…”
BackgroundMethodSelf-citationA low-cost, scalable, current-sensing digital headstage for high channel count μ ECoG
Trumpis, M., Insanally, M., Zou, J., Elsharif, A., Ghomashchi, A., Sertac Artan, N., Froemke, R. C., & Viventi, J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a82 · Cited by 23
Biological Considerations of Optical Interfaces for Neuromodulation
Hart, W. L., Kameneva, T., Wise, A. K., & Stoddart, P. R. (2019) · Advanced Optical Materials · doi:10.1002/adom.201900385 · Cited by 26
Minnikanti, S., Pereira, M. G. A. G., Jaraiedi, S., Jackson, K., Costa-Neto, C. M., Li, Q., & Peixoto, N. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/1/016002 · Cited by 28
General principles of machine learning for brain-computer interfacing
Iturrate, I., Chavarriaga, R., & Millán, J. D. R. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00023-8 · Cited by 26
Long-term flexible penetrating neural interfaces: materials, structures, and implantation
Gu, C., Jiang, J., Tao, T. H., Wei, X., & Sun, L. (2021) · Science China Information Sciences · doi:10.1007/s11432-021-3321-7 · Cited by 24
Emerging Penetrating Neural Electrodes: In Pursuit of Large Scale and Longevity
Luan, L., Yin, R., Zhu, H., & Xie, C. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-090622-050507 · Cited by 28
Methods, caveats and the future of large-scale microelectrode recordings in the non-human primate
Dotson, N. M., Goodell, B., Salazar, R. F., Hoffman, S. J., & Gray, C. M. (2015) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2015.00149 · Cited by 26
Controlling Assistive Machines in Paralysis Using Brain Waves and Other Biosignals
Ribeiro, P. R. D. A., Brasil, F. L., Witkowski, M., Shiman, F., Cipriani, C., Vitiello, N., Carrozza, M. C., & Soekadar, S. R. (2013) · Advances in Human-Computer Interaction · doi:10.1155/2013/369425 · Cited by 26
“Firing patterns acquired through single cell recordings from the motor cortex [77] or parietal neuronal pools [78] in animals were remarkably successful for reconstruction of movement trajectories.”
BackgroundXu, S., Zhang, Y., Zhang, S., Xiao, G., Wang, M., Song, Y., Gao, F., Li, Z., Zhuang, P., Chan, P., et al. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.04.015 · Cited by 24
“…between them, which are of great significance to PD. Non-human primates, whose brains are the similar to humans’, have a natural edge in the study of neural mechanisms, and have been used for neurological studies for decades (Miguel et al., 2003; Suner et al., 2005; Bergman, et al., 1994).”
The Impact of Neurotechnology on Rehabilitation
Berger, T. W., Gerhardt, G. A., Liker, M. A., & Soussou, W. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008687 · Cited by 27
“In fact, over 1 1/2 years of recording have been reported in 2003 using micro-wire arrays [166].”
BackgroundCortical Correlates of Fitts’ Law
Ifft, P. J., Lebedev, M., & Nicolelis, M. A. L. (2011) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2011.00085 · Cited by 26
“Two rhesus monkeys (one male and one female, monkeys M and N, respectively) were chronically implanted with multielectrode arrays in M1 and S1 of both right and left hemispheres using previously described surgical methods (Nicolelis et al., 2003).”
MethodSelf-citationYi, D., Yao, Y., Wang, Y., & Chen, L. (2022) · Journal of Micro and Nano-Manufacturing · doi:10.1115/1.4063179 · Cited by 29
Liu, K., Zhang, H., Hu, M., Li, Z., Xu, K., Chen, D., Cui, W., Lv, C., Ding, R., Geng, X., et al. (2024) · Materials Advances · doi:10.1039/d3ma01105d · Cited by 26
Lo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Ahmed, I., Coffey, K. R., Barker, D., Saste, K., Kals, K., Kaplan, H. M., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9fad · Cited by 24
“microwires, Blackrock Microsystems (Utah) arrays, or NeuroNexus (Michigan) arrays) can often sustain recording performance for several months (6–12 months with good signal-to-noise ratio) before the signal quality begins to drop significantly approximately 18–24 months after device implantation [20, 24, 25] until the…”
BackgroundChen, L., Hartner, J. P., Dong, T., Li, A. D. R., Watson, B. O., & Shih, A. J. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3070781 · Cited by 24
Qi, H., Reed, J. L., Gharbawie, O. A., Burish, M. J., & Kaas, J. H. (2014) · Journal of Neuroscience · doi:10.1523/jneurosci.4954-13.2014 · Cited by 23
Thin-film epidural microelectrode arrays for somatosensory and motor cortex mapping in rat
Hosp, J. A., Molina-Luna, K., Hertler, B., Atiemo, C. O., Stett, A., & Luft, A. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.05.010 · Cited by 29
“704 electrodes in large animals like monkeys) was demonstrated for (1) high-density microwire array-designs (Williams et al., 1999; Nicolelis et al., 2003), (2) silicone-based electrode arrays like the Utah electrode array (UIEA; Rousche and Normann, 1998), the Bionic silicone probe (Suner et al.,…”
Easy-to-Prepare Assembly Array of Tungsten Microelectrodes
Takahashi, H., Suzurikawa, J., Nakao, M., Mase, F., & Kaga, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845224 · Cited by 27
“In fact, numerous novel arrays have been developed to date, such as spike arrays [7]–[12], surface arrays [13], [14], and depth arrays [15]–[17].”
BackgroundCarter, M. E., & Shieh, J. C. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-800511-8.00004-6 · Cited by 30
Development of an invasive brain-machine interface with a monkey model
Zhang, Q., Zhang, S., Hao, Y., Zhang, H., Zhu, J., Zhao, T., Zhang, J., Wang, Y., Zheng, X., & Chen, W. (2012) · Chinese Science Bulletin · doi:10.1007/s11434-012-5096-0 · Cited by 22
Neuronal Assemblies Evidence Distributed Interactions within a Tactile Discrimination Task in Rats
Deolindo, C. S., Kunicki, A. C. B., da Silva, M. I., Brasil, F. L., & Moioli, R. C. (2018) · Frontiers in Neural Circuits · doi:10.3389/fncir.2017.00114 · Cited by 25
“Signal acquisition was performed using the 64-channel OmniPlex Neural Data Acquisition System (Plexon Neurotechnology Research Systems, Dallas, TX), as described previously by Nicolelis et al. (2003).”
MethodOn variability and use of rat primary motor cortex responses in behavioral task discrimination
Jensen, W., & Rousche, P. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/l02 · Cited by 24
Hernández, A., Nácher, V., Luna, R., Álvarez, M., Zainos, A., Cordero, S., Camarillo, L., Vázquez, Y., Lemus, L., & Romo, R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0808702105 · Cited by 22
An investigation of Hebbian phase sequences as assembly graphs
Filho, D. A., Lopes‐dos‐Santos, V., de Vasconcelos, N. A. P., Miranda, J. G. V., Tort, A. B. L., & Ribeiro, S. T. G. (2014) · Frontiers in Neural Circuits · doi:10.3389/fncir.2014.00034 · Cited by 25
“…in the past two decades, the detection and tracking of assemblies became feasible due to major improvements in multi-electrode recording techniques (Nicolelis et al., 2003; Buzsáki, 2004; Schrader et al., 2008), as well as the development of adequate mathematical frameworks for the identification…”
BackgroundEngineering Neural Interfaces for Rehabilitation of Lower Limb Function in Spinal Cord Injured
He, J., Ma, C., & Herman, R. M. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922593 · Cited by 25
Microelectrode Array Recordings from the Ventral Roots in Chronically Implanted Cats
Debnath, S., Bauman, M. J., Fisher, L. E., Weber, D. J., & Gaunt, R. A. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2014.00104 · Cited by 23
Victor, J. D., Goldberg, D. H., & Gardner, D. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.11.001 · Cited by 22
Thin flexible arrays for long-term multi-electrode recordings in macaque primary visual cortex
Merken, L., Schelles, M., Ceyssens, F., Kraft, M. D., & Janssen, P. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac98e2 · Cited by 21
“Currently, most chronic intracorticalMEA are rigid (table 1) although some arrays are flexible such as the microwire arrays [11, 12] and the Neuralink [13] probes.”
BackgroundDevelopment of speech prostheses: current status and recent advances
Brumberg, J. S., & Guenther, F. H. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.34 · Cited by 26
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Marzullo, T., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/049801 · Cited by 21
Advanced Electrical and Optical Microsystems for Biointerfacing
Obaid, S. N., Chen, Z., & Lu, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000091 · Cited by 22
Sharon, A., Jankowski, M. M., Shmoel, N., Erez, H., & Spira, M. E. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.646914 · Cited by 21
Sommakia, S., Rickus, J. L., & Otto, K. J. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332456 · Cited by 21
“This is usually accompanied by a gradual loss of neural density and signal strength over time[ 8 , 9].”
BackgroundStatistical analysis of large-scale neuronal recording data
Reed, J. L., & Kaas, J. H. (2010) · Neural Networks · doi:10.1016/j.neunet.2010.04.005 · Cited by 25
Eleryan, A., Vaidya, M., Southerland, J., Badreldin, I. S., Balasubramanian, K., Fagg, A. H., Hatsopoulos, N., & Oweiss, K. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00023 · Cited by 20
“…assessed by visual inspection of the similarity between units’ waveforms to average waveforms from datasets collected across multiple days of recording (Rousche and Normann, 1998; Nicolelis et al., 2003; Carmena et al., 2005; Linderman et al., 2006; Chestek et al., 2007; Ganguly and Carmena, 2009).”
MethodReed, J. L., Qi, H., Pouget, P., Burish, M. J., Bonds, A. B., & Kaas, J. H. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00566.2010 · Cited by 20
Electrical microstimulation evokes saccades in posterior parietal cortex of common marmosets
Ghahremani, M., Johnston, K., Ma, L., Hayrynen, L. K., & Everling, S. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00417.2019 · Cited by 21
Penetrating multichannel stimulation and recording electrodes in auditory prosthesis research
Anderson, D. J. (2008) · Hearing Research · doi:10.1016/j.heares.2008.01.010 · Cited by 22
Márton, G., Baracskay, P., Cseri, B., Plósz, B., Juhász, G. D., Fekete, Z., & Pongracz, A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026025 · Cited by 21
“where n is the number of clusters, Sn(Q) is the average distances of the elements of cluster Q to the center of cluster Q and d(Qk,Ql) gives the distance between the center of the Qk and Ql clusters [50].”
BackgroundLehmkuhle, M. J., Normann, R. A., & Maynard, E. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01334.2004 · Cited by 20
Ultrasonically actuated neural probes for reduced trauma and inflammation in mouse brain
Chen, P., Young, C. G., Schaffer, C. B., & Lal, A. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00438-3 · Cited by 19
Saniotis, A., Henneberg, M., & Sawalma, A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00153 · Cited by 19
“Signal attenuation of chronic implanted electrodes is primarily caused by host brain tissue response to a foreign object which can lead to microglial activated inflammation and glial scarring (Nicolelis et al., 2003; Polikov et al., 2005), resulting in displacement of proximal neurons from the implanted electrode’s su…”
BackgroundRoles of Motor Cortex Neuron Classes in Reach-Related Modulation for Hemiparkinsonian Rats
Li, M., Wang, X., Yao, X., Wang, X., Chen, F., Zhang, X., Sun, S., He, F., Jia, Q., Guo, M., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.645849 · Cited by 20
“Identification and Classification of Neurons We used the same methods to detect and sort spikes from the saved raw recording data as those used in previous studies (Nicolelis et al., 2003; Dodson et al., 2016; Geng et al., 2016b; Wang et al., 2016).”
MethodHigh-Side Digitally Current Controlled Biphasic Bipolar Microstimulator
Hanson, T., Omarsson, B., O’Doherty, J. E., Peikon, I. D., Lebedev, M., & Nicolelis, M. A. L. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2187219 · Cited by 19
“5–2 ) electrodes are used [10]; [11]; [12].”
Self-citationUrbanchek, M. G., Wei, B. P. C., Egeland, B. M., Abidian, M. R., Kipke, D. R., & Cederna, P. S. (2011) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3182268ac8 · Cited by 21
Nonlinear Modeling of Neural Interaction for Spike Prediction Using the Staged Point-Process Model
Qian, C., Sun, X., Zhang, S., Xing, D., Li, H., Zheng, X., Pan, G., & Wang, Y. (2018) · Neural Computation · doi:10.1162/neco_a_01137 · Cited by 19
Chauvière, L., Pothof, F., Gansel, K. S., Klon-Lipok, J., Aarts, A. A. A., Holzhammer, T., Paul, O., Singer, W., & Ruther, P. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00464 · Cited by 20
Characterization of neural activity recorded from the descending tracts of the rat spinal cord
Prasad, A., & Şahin, M. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00021 · Cited by 22
“, 1999) and later in non-human primates (Baker et al., 1999; Decharms et al., 1999; Wessberg et al., 2000; Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Nicolelis et al., 2003; Hatsopoulos et al., 2004; Musallam et al., 2004; Lebedev et al., 2005; Santhanam et al., 2006; Jackson and Fetz, 2007).”
BackgroundCoupling layers regularizes wave propagation in stochastic neural fields
Kilpatrick, Z. P. (2014) · Physical Review E · doi:10.1103/physreve.89.022706 · Cited by 19
Metadata
- Authors
- Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P.
- Affiliations
- Duke University (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-09-05
- Volume
- 100
- Issue
- 19
- Pages
- 11041-11046
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC196923
- OpenAlex
- W2095504054
- Cited by
- 740
- References
- 28
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 13 · 2023: 12 · 2022: 28 · 2021: 24 · 2020: 28 · 2019: 31 · 2018: 26 · 2017: 31 · 2016: 26 · 2015: 39 · 2014: 49 · 2013: 45 · 2012: 36
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Hispana (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- single-unit recording, macaque, rhesus monkeys, microwire arrays, multi-electrode recording, cortical neurons, neuroprosthetics, sensorimotor integration
- MeSH terms
- Action Potentials, Animals, Cerebral Cortex, Electrodes, Female, Macaca mulatta, Male
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.