Chronic, multisite, multielectrode recordings in macaque monkeys
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A paradigm is described for recording the activity of single cortical neurons from awake, behaving macaque monkeys. Its unique features include high-density microwire arrays and multichannel instrumentation. Three adult rhesus monkeys received microwire array implants, totaling 96–704 microwires per subject, in up to five cortical areas, sometimes bilaterally. Recordings 3–4 weeks after implantation yielded 421 single neurons with a mean peak-to-peak voltage of 115 ± 3 μV and a signal-to-noise ratio of better than 5:1. As many as 247 cortical neurons were recorded in one session, and at least 58 neurons were isolated from one subject 18 months after implantation. This method should benefit neurophysiological investigation of learning, perception, and sensorimotor integration in primates and the development of neuroprosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [340]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davies, D. L., & Bouldin, D. W. (1979) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1979.4766909 · Cited by 9,145
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,123
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Self-citationInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Dynamics of neuronal interactions in monkey cortex in relation to behavioural events
Vaadia, E., Haalman, I., Abeles, M., Bergman, H., Prut, Y., Slovin, H., & Aertsen, A. (1995) · Nature · doi:10.1038/373515a0 · Cited by 812
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
Self-citationDynamic organization of motor control within the olivocerebellar system
Welsh, J. P., Lang, E. J., Suglhara, I., & Llinás, R. (1995) · Nature · doi:10.1038/374453a0 · Cited by 685
Research works printed but not linked: 4
- Evarts, E. V. (1960) Fed. Proc. 19, Suppl. 4, 828–837.
- Davies, D. L. & Bouldin, D. W. (1979) IEEE Trans. Pattern Anal. Machine Intell. 1, 224-227.
- Woolsey, C. N., Settlage, P., Meyer, D. R., Sencer, W., Hamuy, T. P. & Travis, A. M. (1952) Res. Publ. Assoc. Res. Nerv. Ment. Dis. 30, 238-264.
- Mitz, A. R., Godschalk, M. & Wise, S. P. (1991) J. Neurosci. 1, 1855-1872.
Cited by
Items 101–200 of 749
Sparse and Selective Odor Coding by Mitral/Tufted Neurons in the Main Olfactory Bulb
Davison, I. G., & Katz, L. C. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3779-06.2007 · Cited by 161
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
Self-citationDetecting Neural-State Transitions Using Hidden Markov Models for Motor Cortical Prostheses
Kemere, C., Santhanam, G., Yu, B. M., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00924.2007 · Cited by 157
Nanoscale neuro-integrative coatings for neural implants
He, W., & Bellamkonda, R. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.021 · Cited by 156
Neuronal coherence during selective attentional processing and sensory–motor integration
Womelsdorf, T., & Fries, P. (2006) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2007.01.005 · Cited by 156
Implantable intracortical microelectrodes: reviewing the present with a focus on the future
Wang, Y., Yang, X., Zhang, X., Wang, Y., & Pei, W. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00451-6 · Cited by 163
Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design
Prodanov, D., & Delbeke, J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00011 · Cited by 147
“The recording longevity of implanted electrodes is highly variable (see for example for wire electrodes—Liu et al., 1999; Nicolelis et al., 2003 and for silicon-based electrodes and multi-wire arrays—Ward et al., 2009).”
BackgroundReconstructing neuronal circuitry from parallel spike trains
Kobayashi, R., Kurita, S., Kurth, A. C., Kitano, K., Mizuseki, K., Diesmann, M., Richmond, B. J., & Shinomoto, S. (2019) · Nature Communications · doi:10.1038/s41467-019-12225-2 · Cited by 172
“Over the past decade it has become possible to record from much larger numbers of neurons than in the past (Wilson and McNaughton, 1993; Nicolelis et al., 2003; Smith and Kohn, 2008; Schwarz et al., 2014; Mitz et al., 2017), even though this number is still a mere shadow of the total number of…”
BackgroundLuan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
“For instance, Utah or microwire arrays, which have enabled relatively large-scale recordings (hundreds of neurons) from primates (Dickey et al., 2009; Dotson et al., 2015; Nicolelis et al., 2003; Suner et al., 2005), typically carry only one recording site on the tip of each wire, and usually have contact spacings of…”
BackgroundKong, Y. L., Gupta, M. K., Johnson, B. N., & McAlpine, M. C. (2016) · Nano Today · doi:10.1016/j.nantod.2016.04.007 · Cited by 147
Voigts, J., Siegle, J. H., Pritchett, D. L., & Moore, C. I. (2013) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2013.00008 · Cited by 147
“METHODS ARTICLE published: 13 May 2013 doi: 10.3389/fnsys.2013.00008 The flexDrive: an ultra-light implant for optical control and highly parallel chronic recording of neuronal ensembles in freely moving mice Jakob Voigts1,2, Joshua H. Siegle1,2, Dominique L. Pritchett 2,3 and Christopher I. Moore2* 1 Department of Br…”
BackgroundInfluentialWearable and Implantable Electroceuticals for Therapeutic Electrostimulations
Long, Y., Li, J., Yang, F., Wang, J., & Wang, X. (2021) · Advanced Science · doi:10.1002/advs.202004023 · Cited by 149
3D-nanostructured boron-doped diamond for microelectrode array neural interfacing
Piret, G., Hébert, C., Mazellier, J.-P., Rousseau, L., Scorsone, E., Cottance, M., Lissorgues, G., Heuschkel, M. O., Picaud, S., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.021 · Cited by 135
Nanostructures: a platform for brain repair and augmentation
Vidu, R., Rahman, M., Mahmoudi, M., Enăchescu, M., Potecă, T. D., & Opriș, I. C. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00091 · Cited by 171
Long-term changes in the material properties of brain tissue at the implant–tissue interface
Sridharan, A., Rajan, S. D., & Muthuswamy, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066001 · Cited by 132
Safety Encoding in the Basal Amygdala
Sangha, S., Chadick, J. Z., & Janak, P. H. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.3302-12.2013 · Cited by 133
Using multi-neuron population recordings for neural prosthetics
Chapin, J. K. (2004) · Nature Neuroscience · doi:10.1038/nn1234 · Cited by 139
Ribeiro, S. (2007) · Frontiers in Neuroscience · doi:10.3389/neuro.01.1.1.003.2007 · Cited by 128
“The correlation between arc mRNA levels and LFP amplitude in the spindle-range suggests that arc expression may be proportional to specific parts of the fMRI BOLD signal, which is also strongly proportional to LFP amplitudes (Logothetis et al., 2001; Niessing et al., 2005).”
BackgroundSelf-citationClinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Moxon, K. A., Kalkhoran, N. M., Markert, M., Sambito, M. A., McKenzie, J. L., & Webster, J. T. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827465 · Cited by 135
“However, the yield for single unit recordings from Si probes has been very low [16] compared with microwires [17], [18] and the Utah array [19].”
Otto, K. J., Johnson, M. D., & Kipke, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862530 · Cited by 131
Future developments in brain-machine interface research
Lebedev, M. A., Tate, A. J., Hanson, T. L., Li, Z., O'Doherty, J. E., Winans, J. A., Ifft, P. J., Zhuang, K. Z., Fitzsimmons, N. A., Schwarz, D. A., et al. (2011) · Clinics · doi:10.1590/s1807-59322011001300004 · Cited by 130
“In these studies, we implant multielectrode arrays in multiple cortical areas of the rhesus monkey’s brain.(30) The present generation of chronic multielectrode implants is capable of recording the extracellular electrical activity of hundreds of cortical cells.”
BackgroundMethodSelf-citationPillow, J. W., Ahmadian, Y., & Paninski, L. (2010) · Neural Computation · doi:10.1162/neco_a_00058 · Cited by 133
Responses of Trigeminal Ganglion Neurons during Natural Whisking Behaviors in the Awake Rat
Leiser, S. C., & Moxon, K. A. (2007) · Neuron · doi:10.1016/j.neuron.2006.10.036 · Cited by 141
Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration
Kuo, J. T. W., Kim, B. J., Hara, S. A., Lee, C. D., Gutierrez, C. A., Hoang, T. Q., & Meng, E. (2013) · Lab Chip · doi:10.1039/c2lc40935f · Cited by 127
Ultrasound-induced wireless energy harvesting: from materials strategies to functional applications
Jiang, L., Yang, Y., Chen, Y., & Zhou, Q. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105131 · Cited by 131
Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances
Johnson, M. D., Otto, K. J., & Kipke, D. R. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847373 · Cited by 130
Converging Cognitive Enhancements
Sandberg, A., & Bostrom, N. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1382.015 · Cited by 154
Continuous Shared Control for Stabilizing Reaching and Grasping With Brain-Machine Interfaces
Kim, H. K., Biggs, S. J., Schloerb, D. W., Carmena, J. M., Lebedev, M. A., Nicolelis, M. A. L., & Srinivasan, M. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870235 · Cited by 123
Self-citationThe Argo: a high channel count recording system for neural recording in vivo
Sahasrabuddhe, K., Khan, A. A., Singh, A. P., Stern, T. M., Ng, Y., Tadić, A., Orel, P., LaReau, C., Pouzzner, D., Nishimura, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd0ce · Cited by 124
Morphological Development of Thick-Tufted Layer V Pyramidal Cells in the Rat Somatosensory Cortex
Romand, S., Wang, Y., Toledo-Rodriguez, M., & Markram, H. (2011) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2011.00005 · Cited by 122
“In addition to extrinsic cues such as neurotrophins, differential developmental changes in localized multiple compartments of a neuron may also depend on other factors, including different electrical inputs, neurons’ own distinct electrical properties, and molecular compositions (such as ion channels, receptors, and s…”
BackgroundSuperlinear Population Encoding of Dynamic Hand Trajectory in Primary Motor Cortex
Paninski, L., Shoham, S., Fellows, M. R., Hatsopoulos, N. G., & Donoghue, J. P. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.0919-04.2004 · Cited by 121
“As expected, this kinematic overlap was a strong predictor of the information one cell would carry about another (Spearman’s rank correlation test), and the informativeness of the network alone, I(spike; a n ) was positively correlated with the number of cells observed (Nicolelis et al., 2003; Paninski et al., 2004).”
BackgroundResultAdvances in nanowire bioelectronics
Zhou, W., Dai, X., & Lieber, C. M. (2017) · Reports on Progress in Physics · doi:10.1088/0034-4885/80/1/016701 · Cited by 117
Spatiotemporal Coupling between Hippocampal Acetylcholine Release and Theta Oscillations In Vivo
Zhang, H., Lin, S.-C., & Nicolelis, M. A. L. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.1144-10.2010 · Cited by 117
“Single units were identified with their distinctive waveforms, separation from noise clusters, and clear refractory period ( 1 ms) based on the interspike interval histogram (Nicolelis et al., 2003).”
MethodSelf-citationA comparison of optimal MIMO linear and nonlinear models for brain–machine interfaces
Kim, S.-P., Sanchez, J. C., Rao, Y. N., Erdogmus, D., Carmena, J. M., Lebedev, M. A., Nicolelis, M. A. L., & Principe, J. C. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/009 · Cited by 118
Self-citationBrumberg (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00065 · Cited by 114
“Two well known designs include the planar (or Michigan) array (Wise et al., 1970; Hoogerwerf and Wise, 1994) and microwire array (Williams et al., 1999; Taylor et al., 2002; Nicolelis et al., 2003), though these devices are not approved for human use.”
Toward a self-deploying shape memory polymer neuronal electrode
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/l02 · Cited by 113
Naïve coadaptive cortical control
Gage, G. J., Ludwig, K. A., Otto, K. J., Ionides, E. L., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/2/006 · Cited by 109
Steady or changing? Long-term monitoring of neuronal population activity
Lütcke, H., Margolis, D. J., & Helmchen, F. (2013) · Trends in Neurosciences · doi:10.1016/j.tins.2013.03.008 · Cited by 126
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111
Ascertaining the Importance of Neurons to Develop Better Brain-Machine Interfaces
Sanchez, J. C., Carmena, J. M., Lebedev, M. A., Nicolelis, M. A. L., Harris, J. G., & Principe, J. C. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827061 · Cited by 111
Self-citationBridging the divide between neuroprosthetic design, tissue engineering and neurobiology
Leach, J. (2010) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.018.2009 · Cited by 112
“…or robotic (Maynard et al., 2000; Csicsvari et al., 2003; Nicolelis et al., 2003; Szarowski et al., 2003)], speed of insertion (Edell et al., 1992; Nicolelis et al., 2003; Bjornsson et al., 2006), and most importantly, implantation approach (Biran et al., 2007) all have been reported to affect…”
InfluentialInvasive or Noninvasive: Understanding Brain-Machine Interface Technology [Conversations in BME
del R. Milan, J., & Carmena, J. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2009.935475 · Cited by 100
Self-citationThe sinusoidal probe: a new approach to improve electrode longevity
Sohal, H. S., Jackson, A., Jackson, R., Clowry, G. J., Vassilevski, K., O’Neill, A., & Baker, S. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00010 · Cited by 106
“…electrode materials include silicon (e.g., the“Utah”array, Rousche and Normann, 1998 and “Michigan” probe, Kipke et al., 2003) and metal microwires (Nicolelis et al., 2003; Jackson and Fetz, 2007) which have a higher Young’s modulus (YM, ∼150 GPa) than brain tissue (5–30 KPa; Miller et al.,…”
InfluentialMulti-channel fiber photometry for population neuronal activity recording
Guo, Q., Zhou, J., Feng, Q., Lin, R., Gong, H., Luo, Q., Zeng, S., Luo, M., & Fu, L. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003919 · Cited by 105
Minnikanti, S., Diao, G., Pancrazio, J. J., Xie, X., Rieth, L. W., Solzbacher, F., & Peixoto, N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.031 · Cited by 114
“Microwire arrays typically fail 18 months after implantation [7].”
BackgroundCommon-input models for multiple neural spike-train data
Kulkarni, J. E., & Paninski, L. (2007) · Network: Computation in Neural Systems · doi:10.1080/09548980701625173 · Cited by 113
“There is a large body of literature tackling the problem of developing statistical models for largescale simultaneous spike-train recordings (Chornoboy et al. 1988; Utikal 1997; Martignon et al. 2000; Iyengar 2001; Schnitzer and Meister 2003; Nicolelis et al. 2003; Cossart et al. 2003; Paninski et al. 2004; Truccolo e…”
3D printing and modelling of customized implants and surgical guides for non-human primates.
Chen, X., Possel, J. K., Wacongne, C., van Ham, A. F., Klink, P. C., & Roelfsema, P. R. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.05.013 · Cited by 106
Modeling the impact of common noise inputs on the network activity of retinal ganglion cells
Vidne, M., Ahmadian, Y., Shlens, J., Pillow, J. W., Kulkarni, J., Litke, A. M., Chichilnisky, E. J., Simoncelli, E., & Paninski, L. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0376-2 · Cited by 110
“2005), motor cortex (Nicolelis et al. 2003; Wu et al. 2008), visual cortex (Ohki et al.”
Extraction of Network Topology From Multi-Electrode Recordings: Is there a Small-World Effect?
Gerhard, F., Pipa, G., Lima, B., Neuenschwander, S., & Gerstner, W. (2011) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2011.00004 · Cited by 114
“Since GLMs are set up on the basis of maximum-likelihood estimation, the threshold can be chosen by cross-validation and is therefore not a free parameter of the estimation procedure.”
BackgroundLind, G., Linsmeier, C. E., Thelin, J., & Schouenborg, J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046005 · Cited by 98
“5 μm wire is about 2000 times more flexible than a 50 μm wire of the same material, which is a very commonly used dimension [5, 13, 14, 31].”
BackgroundUltraflexible Neural Electrodes for Long-Lasting Intracortical Recording
He, F., Lycke, R., Ganji, M., Xie, C., & Luan, L. (2020) · iScience · doi:10.1016/j.isci.2020.101387 · Cited by 105
Freire, M. A. M., Morya, E., Faber, J., Santos, J. R., Guimaraes, J. S., Lemos, N. A. M., Sameshima, K., Pereira, A., Ribeiro, S., & Nicolelis, M. A. L. (2011) · PLoS ONE · doi:10.1371/journal.pone.0027554 · Cited by 97
“Tungsten is a good choice of material for chronic implants since it is a stable and inert metal, and has been successfully used to simultaneously record neuronal populations for several months and even years [3,19,35,39].”
BackgroundSelf-citationA biodegradable and self-deployable electronic tent electrode for brain cortex interfacing
Bae, J., Hwang, G., Kim, Y.-S., Jeon, J., Chae, M., Kim, J., Lee, S., Kim, S., Lee, S.-H., Choi, S., et al. (2024) · Nature Electronics · doi:10.1038/s41928-024-01216-x · Cited by 109
Casanova, F., Carney, P. R., & Sarntinoranont, M. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.08.012 · Cited by 100
“In contrast, electrodes inserted at slower speeds have shown better performance, which is thought to be due in part to less initial tissue damage (Nicolelis et al., 2003).”
BackgroundLu, Y., Li, Y., Pan, J., Wei, P., Liu, N., Wu, B., Cheng, J., Lu, C., & Wang, L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.09.083 · Cited by 102
“[37].”
A system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96
“HE DEVELOPMENT of multielectrode recording techniques [ 1 ]–[3] has led to rapid advances in cortical brain– machine interfaces (BMIs) [4]–[10].”
MethodSelf-citationIntracortical Recording Interfaces: Current Challenges to Chronic Recording Function
Gunasekera, B., Saxena, T., Bellamkonda, R., & Karumbaiah, L. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn5002864 · Cited by 93
Electrode materials for brain–machine interface: A review
Wu, N., Wan, S., Su, S., Huang, H., Dou, G., & Sun, L. (2021) · InfoMat · doi:10.1002/inf2.12234 · Cited by 100
Stimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95
Conducting polymers for neuronal microelectrode array recording and stimulation
Aqrawe, Z., Montgomery, J. M., Travaš‐Sejdić, J., & Svirskis, D. M. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.023 · Cited by 102
Leung, B. K., Biran, R., Underwood, C. J., & Tresco, P. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.045 · Cited by 97
House, P. A., MacDonald, J. D., Tresco, P. A., & Normann, R. A. (2006) · Neurosurgical Focus · doi:10.3171/foc.2006.20.5.5 · Cited by 89
Injectable Biomedical Devices for Sensing and Stimulating Internal Body Organs
Jung, Y. H., Kim, J. U., Lee, J. S., Shin, J. H., Jung, W., Ok, J., & Kim, T. (2020) · Advanced Materials · doi:10.1002/adma.201907478 · Cited by 87
Elastomeric and soft conducting microwires for implantable neural interfaces
Kolarcik, C. L., Luebben, S. D., Sapp, S. A., Hanner, J., Snyder, N., Kozai, T. D. Y., Chang, E., Nabity, J. A., Nabity, S. T., Lagenaur, C. F., et al. (2015) · Soft Matter · doi:10.1039/c5sm00174a · Cited by 88
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
The Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 87
Reincke, S. A. J., & Hanganu-Opatz, I. L. (2017) · Scientific Reports · doi:10.1038/srep42042 · Cited by 80
Brain-Machine Interfaces: Powerful Tools for Clinical Treatment and Neuroscientific Investigations
Slutzky, M. W. (2019) · The Neuroscientist · doi:10.1177/1073858418775355 · Cited by 81
Bennett, C., Mohammed, F. S., Álvarez-Ciara, A., Nguyen, M. A., Dietrich, W. D., Rajguru, S. M., Streit, W. J., & Prasad, A. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.040 · Cited by 90
Evaluation of the stability of intracortical microelectrode arrays
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.870495 · Cited by 84
Progress in conducting polymers for biointerfacing and biorecognition applications
Maziz, A., Özgür, E., Bergaud, C., & Uzun, L. (2021) · Sensors and Actuators Reports · doi:10.1016/j.snr.2021.100035 · Cited by 94
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 92
Fuentes, R., Petersson, P., & Nicolelis, M. A. L. (2010) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2010.07417.x · Cited by 85
“The neural correlate can be obtained using chronic multi-structure electrophysiological recordings in behaving animals (Nicolelis et al., 2003), and detailed quantitative and qualitative aspects of locomotive behavior can be acquired through video image analysis (Fitzsimmons et al., 2009; Liu et…”
BackgroundSelf-citationCarbon nanofiber-PEDOT composite films as novel microelectrode for neural interfaces and biosensing
Saunier, V., Emmanuel Flahaut, B., Blatché, M.-C., Bergaud, C., & Maziz, A. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112413 · Cited by 88
Spatiotemporal pH dynamics following insertion of neural microelectrode arrays
Johnson, M. D., Kao, O. E., & Kipke, D. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.023 · Cited by 94
Low-latency multi-threaded processing of neuronal signals for brain-computer interfaces
Fischer, J., Milekovic, T., Schneider, G., & Mehring, C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00001 · Cited by 79
Homayoun, H., & Moghaddam, B. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0842-06.2006 · Cited by 80
“These included parametric F statistics of multivariate ANOVA, the J3 and pseudo-F statistics, and the Davies–Bouldin (DB) validity index (Nicolelis et al., 2003).”
Physiological Challenges for Intracortical Electrodes
Groothuis, J., Ramsey, N. F., Ramakers, G. M. J., & Plasse, G. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.07.001 · Cited by 86
“Similarly, the quality of recordings using microwire arrays in macaque monkeys stabilized 4e6 weeks after implantation [27], which again seems to correlate to the consolidation of the FBR in these animals.”
Scalable batch fabrication of ultrathin flexible neural probes using a bioresorbable silk layer
Cointe, C., Laborde, A., Nowak, L. G., Arvanitis, D. N., Bourrier, D., Bergaud, C., & Maziz, A. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00353-7 · Cited by 78
“acetate deposition, (2) silk fibroin deposition, (3) parylene base layer deposition, (4) gold microelectrode patterning, (5) parylene top layer deposition”
BackgroundRecording of brain activity across spatial scales
Lewis, C., Bosman, C., & Fries, P. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2014.12.007 · Cited by 76
“Further work in non-human primates has extended these findings to correlate information flow with task state and performance [13 ,14,16,17,50 ,73–78].”
Welkenhuysen, M., Andrei, A., Ameye, L., Eberle, W., & Nuttin, B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2166963 · Cited by 85
In vivo evaluation of a neural stem cell-seeded prosthesis
Purcell, E. K., Seymour, J. P., Yandamuri, S., & Kipke, D. R. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026005 · Cited by 76
Can One Concurrently Record Electrical Spikes from Every Neuron in a Mammalian Brain?
Kleinfeld, D., Luan, L., Mitra, P. P., Robinson, J. T., Sarpeshkar, R., Shepard, K. L., Xie, C., & Harris, T. D. (2019) · Neuron · doi:10.1016/j.neuron.2019.08.011 · Cited by 83
Seven years of recording from monkey cortex with a chronically implanted multiple microelectrode
Krüger, J. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00006 · Cited by 73
Recent progress in multi-electrode spike sorting methods
Lefebvre, B., Yger, P., & Marre, O. (2016) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2017.02.005 · Cited by 83
Ince, N. F., Gupta, R., Arica, S., Tewfik, A. H., Ashe, J., & Pellizzer, G. (2010) · PLoS ONE · doi:10.1371/journal.pone.0014384 · Cited by 74
“5 years [32,33].”
Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications
Hashemi, P., Walsh, P. L., Guillot, T. S., Gras-Najjar, J., Takmakov, P. A., Crews, F. T., & Wightman, R. M. (2011) · ACS Chemical Neuroscience · doi:10.1021/cn2000684 · Cited by 82
Reagentless aptamer based impedance biosensor for monitoring a neuro-inflammatory cytokine PDGF
Liao, W., & Cui, X. T. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.04.004 · Cited by 78
Melatonin improves quality and longevity of chronic neural recording
Golabchi, A., Wu, B., Li, X., Carlisle, D. L., Kozai, T. D. Y., Friedlander, R. M., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.026 · Cited by 82
“[11] Nicolelis MAL, Dimitrov D, Carmena JM, Crist R, Lehew G, Kralik JD, et al.”
InfluentialWidespread spatial integration in primary somatosensory cortex
Reed, J. L., Pouget, P., Qi, H.-X., Zhou, Z., Bernard, M. R., Burish, M. J., Haitas, J., Bonds, A. B., & Kaas, J. H. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0803800105 · Cited by 74
“05 for multivariate ANOVA related to cluster separation, and distinct waveform amplitudes and shapes when compared with other activity on the same electrode (40).”
BackgroundChronic multi-electrode neural recording in free-roaming monkeys
Eliades, S. J., & Wang, X. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.04.029 · Cited by 72
Fast Modulation of Prefrontal Cortex Activity by Basal Forebrain Noncholinergic Neuronal Ensembles
Lin, S.-C., Gervasoni, D., & Nicolelis, M. A. L. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00524.2006 · Cited by 71
“Single-unit activities with 3:1 signal-to-noise ratio were sorted on-line and later confirmed with an off-line sorting algorithm (Plexon) as previously described (Nicolelis et al. 2003).”
MethodSelf-citationCortical neurons multiplex reward-related signals along with sensory and motor information
Ramakrishnan, A., Byun, Y. W., Rand, K., Pedersen, C. E., Lebedev, M., & Nicolelis, M. A. L. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1703668114 · Cited by 74
Self-citationRizk, M., Obeid, I., Callender, S. H., & Wolf, P. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/016 · Cited by 71
“As a result, a value of 1 to 2 is realistic for the ratio of total units to electrodes [1, 16].”
BackgroundInfluentialSantucci, D. M., Kralik, J. D., Lebedev, M. A., & Nicolelis, M. A. L. (2005) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2005.04320.x · Cited by 69
“Arrays of 16 or 32 50-lm-diameter stainless steel microwires were chronically implanted (Kralik et al., 2001; Nicolelis et al., 2003) under isoflurane anesthesia in the hand ⁄ arm regions of PMd, M1 and area 3b of S1, and in the dorsolateral aspect of the superior parietal lobule of PPC in each…”
MethodSelf-citationRennaker, R. L., Street, S. E., Ruyle, A. M., & Sloan, A. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.08.009 · Cited by 70
“Several authors have reported the use of microwire igns (Schmidt et al., 1976, 1988; Westby and Wang, 19 enkatachalam et al., 1999; Williams et al., 1999a, b; Kr t al., 2001; Nicolelis et al., 2003).”
Electrophysiological recordings from behaving animals—going beyond spikes
Chorev, E., Epsztein, J., Houweling, A. R., Lee, A. K., & Brecht, M. (2009) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2009.08.005 · Cited by 80
“Previously, recording stability across days was claimed on the basis of similarity between action potential waveforms [19,20] or waveform features [21].”
Ouyang, L., Shaw, C. L., Kuo, C.-C., Griffin, A. L., & Martin, D. C. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026005 · Cited by 73
Neurofeedback Therapy for Enhancing Visual Attention: State-of-the-Art and Challenges
Ordikhani-Seyedlar, M., Lebedev, M., Sørensen, H. B. D., & Puthusserypady, S. K. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00352 · Cited by 80
Metadata
- Authors
- Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P.
- Affiliations
- Duke University (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-09-05
- Volume
- 100
- Issue
- 19
- Pages
- 11041-11046
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC196923
- OpenAlex
- W2095504054
- Cited by
- 740
- References
- 28
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 13 · 2023: 12 · 2022: 28 · 2021: 24 · 2020: 28 · 2019: 31 · 2018: 26 · 2017: 31 · 2016: 26 · 2015: 39 · 2014: 49 · 2013: 45 · 2012: 36
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Hispana (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- single-unit recording, macaque, rhesus monkeys, microwire arrays, multi-electrode recording, cortical neurons, neuroprosthetics, sensorimotor integration
- MeSH terms
- Action Potentials, Animals, Cerebral Cortex, Electrodes, Female, Macaca mulatta, Male
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.