Chronic, multisite, multielectrode recordings in macaque monkeys
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A paradigm is described for recording the activity of single cortical neurons from awake, behaving macaque monkeys. Its unique features include high-density microwire arrays and multichannel instrumentation. Three adult rhesus monkeys received microwire array implants, totaling 96–704 microwires per subject, in up to five cortical areas, sometimes bilaterally. Recordings 3–4 weeks after implantation yielded 421 single neurons with a mean peak-to-peak voltage of 115 ± 3 μV and a signal-to-noise ratio of better than 5:1. As many as 247 cortical neurons were recorded in one session, and at least 58 neurons were isolated from one subject 18 months after implantation. This method should benefit neurophysiological investigation of learning, perception, and sensorimotor integration in primates and the development of neuroprosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [340]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davies, D. L., & Bouldin, D. W. (1979) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1979.4766909 · Cited by 9,145
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,123
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Self-citationInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Dynamics of neuronal interactions in monkey cortex in relation to behavioural events
Vaadia, E., Haalman, I., Abeles, M., Bergman, H., Prut, Y., Slovin, H., & Aertsen, A. (1995) · Nature · doi:10.1038/373515a0 · Cited by 812
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
Self-citationDynamic organization of motor control within the olivocerebellar system
Welsh, J. P., Lang, E. J., Suglhara, I., & Llinás, R. (1995) · Nature · doi:10.1038/374453a0 · Cited by 685
Research works printed but not linked: 4
- Evarts, E. V. (1960) Fed. Proc. 19, Suppl. 4, 828–837.
- Davies, D. L. & Bouldin, D. W. (1979) IEEE Trans. Pattern Anal. Machine Intell. 1, 224-227.
- Woolsey, C. N., Settlage, P., Meyer, D. R., Sencer, W., Hamuy, T. P. & Travis, A. M. (1952) Res. Publ. Assoc. Res. Nerv. Ment. Dis. 30, 238-264.
- Mitz, A. R., Godschalk, M. & Wise, S. P. (1991) J. Neurosci. 1, 1855-1872.
Cited by
Items 401–500 of 749
Billard, M. W., Bahari, F., Kimbugwe, J., Alloway, K. D., & Gluckman, B. J. (2018) · eNeuro · doi:10.1523/eneuro.0261-18.2018 · Cited by 18
“Although static electrode implants are used for large-scale multisite recordings (Nicolelis et al., 2003; Xie et al., 2016), their yields and stability are limited by the accuracy of electrode placement.”
BackgroundVandekerckhove, B., Missinne, J., Vonck, K. E. J., Bauwens, P., Verplancke, R., Boon, P., Raedt, R., & Vanfleteren, J. (2020) · Micromachines · doi:10.3390/mi12010038 · Cited by 20
“Usually, these systems contain a single [43,44] or a few (micro)wires [45–48], although microwire probes containing dozens [49,50] up to hundreds [51] of microwires have been reported.”
BackgroundKennedy, P. (2011) · Neurocase · doi:10.1080/13554794.2010.532137 · Cited by 20
Debnath, S., Prins, N. W., Pohlmeyer, E. A., Mylavarapu, R. V., Geng, S., Sanchez, J. C., & Prasad, A. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aada67 · Cited by 19
MEMS-Actuated Carbon Fiber Microelectrode for Neural Recording
Zoll, R. S., Schindler, C. B., Massey, T. L., Drew, D., Maharbiz, M. M., & Pister, K. S. J. (2019) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2019.2905505 · Cited by 18
“to unique depths to maximize recorded unit activity on each electrode [5], [6].”
BackgroundXu, K., Wang, Y., Wang, F., Liao, Y., Zhang, Q., Li, H., & Zheng, X. (2014) · BioMed Research International · doi:10.1155/2014/685492 · Cited by 17
“Due to the great development of the neural recording technology in the last decade, hundreds of neurons can be simultaneously recorded to build a high-dimensional data space [33].”
BackgroundLudwig, K. A., Miriani, R. M., Langhals, N. B., Marzullo, T. C., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046009 · Cited by 17
He, F., Sun, Y., Jin, Y., Yin, R., Zhu, H., Rathore, H., Xie, C., & Luan, L. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121905 · Cited by 20
Brain-machine interfaces as the new frontier in extreme miniaturization
Rabaey, J. M. (2011) · European Solid-State Device Research Conference · doi:10.1109/essderc.2011.6044240 · Cited by 18
Single-unit activity in marmoset posterior parietal cortex in a gap saccade task
Ma, L., Selvanayagam, J., Ghahremani, M., Hayrynen, L. K., Johnston, K., & Everling, S. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00614.2019 · Cited by 17
Electrode Arrays for Detecting and Modulating Deep Brain Neural Information in Primates: A Review
Zhang, S., Song, Y., Lv, S., Jing, L., Wang, M., Liu, Y., Xu, W., Jiao, P., Zhang, S., Wang, M., et al. (2025) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0249 · Cited by 16
“Nicolelis et al. [ 47 ] implanted microwire array composed of hundreds of stainless steel microwires into the monkey cerebral cortex for long-term multi-site recording.”
Sanchez, J. C., Príncipe, J. C., Carmena, J. M., Lebedev, M., & Nicolelis, M. A. L. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404486 · Cited by 16
“Microwire electrode arrays [7] were chronically implanted in the dorsal premotor cortex (PMd), supplementary motor area (SMA), primary motor cortex (M1, both hemispheres) and primary somatosensory cortex (S1) of an adult female”
MethodSelf-citationFailure Modes of Implanted Neural Interfaces
Delbeke, J., Haesler, S., & Prodanov, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_6 · Cited by 17
Zhang, X., Zhang, R. L., Zhang, Z. G., & Chopp, M. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.12.012 · Cited by 17
Pais-Vieira, M., Kunicki, C., Tseng, P.-H., Martin, J. R., Lebedev, M., & Nicolelis, M. A. L. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00108.2015 · Cited by 16
“These cumulative criteria were complemented with inspection of metrics of the quality of single-unit isolation in freely behaving animals (J3, Davis-Bouldin, F, and Pseudo-F) (Nicolelis et al. 2003).”
Self-citationDesign and application of brain-computer interface web browser based on VEP
Yin, J., Jiang, D., & Hu, J. (2009) · International Conference on Future BioMedical Information Engineering · doi:10.1109/fbie.2009.5405788 · Cited by 16
Tunable nanostructured conducting polymers for neural interface applications
Antensteiner, M., & Abidian, M. R. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037214 · Cited by 18
“[4] Furthermore, attempts to increase electrode sites per implant device in an effort to increase selectivity will reduce the surface area, resulting in higher impedance or lower sensitivity at electrode-tissue interface.”
Flexible kirigami microelectrode arrays for neuronal activity recordings in non-human primate brains
FANG, R., Tian, H., Du, Y., Zhao, Y., Yang, Y., Guan, S., Li, S., Liu, M., Xu, K., & Fang, Y. W. (2026) · Nature Electronics · doi:10.1038/s41928-025-01560-6 · Cited by 17
Wireless interfaces for brain neurotechnologies
Kim, H., & Ho, J. S. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0020 · Cited by 18
Bidirectional mechanisms and emerging strategies for implantable bioelectronic interfaces
Yan, Z., Gao, W., Duan, Y.-Y., Zhou, H., Ni, C., Huang, L., & Ye, Z. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.06.014 · Cited by 16
“This could be associated with the type of implanted device, the relative movement of brain tissue in the subjects, and species differences in terms of glial responses [31].”
Surgical Techniques for Chronic Implantation of Microwire Arrays in Rodents and Primates
Nicolelis, M. A. L. (2007) · CRC Press eBooks · doi:10.1201/9781420006414-7 · Cited by 15
Self-citationIn Vivo Neural Interfaces—From Small- to Large-Scale Recording
Zhang, B., Deng, C., Cai, C., & Li, X. (2022) · Frontiers in Nanotechnology · doi:10.3389/fnano.2022.885411 · Cited by 15
“For the application of microwire electrodes in large-scale recording, it is necessary to solve the problem of connecting the electrode array composed of a large number of microwires to the amplifier array (Mal et al., 2003).”
BackgroundQi, H., Reed, J. L., Franca, J. G., Jain, N., Kajikawa, Y., & Kaas, J. H. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00634.2015 · Cited by 16
Binless Kernel Machine: Modeling Spike Train Transformation for Cognitive Neural Prostheses
Qian, C., Sun, X., Wang, Y., Zheng, X., Wang, Y., & Pan, G. (2020) · Neural Computation · doi:10.1162/neco_a_01306 · Cited by 18
“) to restore the spike timings for further processing (Nicolelis et al., 2003).”
BackgroundMethodXu, L., Li, Q., Ke, Y., & Yung, W. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2021.784045 · Cited by 16
“Significant changes in the gray matter and white matter are often found in the hippocampal area in both adult and children OSA subjects (Macey et al., 2002; Morrell et al., 2010; Torelli et al., 2011; Cha et al., 2017; Song et al., 2018; Owen et al., 2019).”
BackgroundSatava, R. M. (2009) · Cited by 15
Tremblay, S., Pieper, F., Sachs, A. J., Joober, R., & Martínez-Trujillo, J. (2019) · eNeuro · doi:10.1523/eneuro.0371-18.2018 · Cited by 15
“More recently, new technologies that allow recording the activity of multiple neurons simultaneously in behaving animals (Nicolelis et al., 2003; Buzsáki, 2004) have shined a new light on those mechanisms.”
BackgroundComparison of TDNN training algorithms in brain machine interfaces
Wang, Y., Kim, S.-P., & Príncipe, J. C. (2006) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2005.1556288 · Cited by 15
“An adult, female monkey was instrumented with high-density microelectrode arrays [11], implanted stereotaxically in seven cortical neural structures that are involved in the controlling fine arm and hand movements.”
MethodMueller, N. N., Ocoko, M. Y. M., Kim, Y., Li, K., Gisser, K., Glusauskas, G., Lugo, I., Dernelle, P., Hermoso, A. C., Wang, J., et al. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00440-5 · Cited by 15
Gerboni, G., John, S. E., Rind, G. S., Ronayne, S. M., May, C. N., Oxley, T. J., Grayden, D. B., Opie, N. L., & Wong, Y. T. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aad714 · Cited by 14
“Similar characterizations of chronic signal quality of invasive neural interfacing systems have been reported by other groups (Nicolelis et al 2003, Suner et al 2005, Chestek et al 2011).”
BackgroundMarmosets in Auditory Research
Eliades, S. J., & Tsunada, J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811829-0.00025-x · Cited by 14
Electronic Interfacing with Living Cells
Fleming, J. T. (2009) · Springer eBooks · doi:10.1007/10_2009_5 · Cited by 19
“For example, one study using rhesus monkeys reported a 40% drop in the number of functional brain implanted electrodes over a period of 18 months [17] .”
BackgroundA high sensitive in vivo biosensing detection for odors by multiunit in rat olfactory bulb
Zhuang, L., Hu, N., Dong, Q., Liu, Q., & Wang, P. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.06.032 · Cited by 14
Paralikar, K. J., Lawrence, J. K., & Clement, R. S. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260302 · Cited by 15
“Varied solutions are available: bundles of microwires [1, 2 ], micro-machined tines of silicon [3], and planar multi-site/shank structures [4].”
MethodMonitoring Insertion Force and Electrode Impedance during Implantation of Microwire Electrodes
Tian, C., & He, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616205 · Cited by 14
“activities for decades [1], yet successful implantation of microwire electrodes still remains largely as an art, not a”
BackgroundA biodegradable porous silicon and polymeric hybrid probe for electrical neural signal recording
Xue, N., Wang, D., Liu, C., Ke, Z., Elia, P., Li, T., Chi, C., Cheng, Y., & Sun, J. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.06.001 · Cited by 15
Geng, X., Wang, X., He, F., Zhang, X., Xie, J., Gao, G., Han, H., Yao, X., Zhang, H., Gao, Y., et al. (2019) · Neuroscience · doi:10.1016/j.neuroscience.2019.01.044 · Cited by 14
Ma, J., Zhao, Z., Cui, S., Liu, F., Yi, M., & Wan, Y. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01322 · Cited by 14
Wong, Y. T., Ahnood, A., Maturana, M. I., Kentler, W. G., Ganesan, K., Grayden, D. B., Meffin, H., Prawer, S., Ibbotson, M. R., & Burkitt, A. N. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00085 · Cited by 14
“N-UNCD Multi-Electrode Arrays for Neural Recordings In the last two decades, there has been a large push to record from larger areas of cortex, as well as to increase the recording density in a given area (Nicolelis et al., 2003; Kipke et al., 2008; Viventi et al., 2011; Dotson et al., 2015).”
BackgroundBraving New Worlds: To Conquer, to Endure
Moffat, M. (2004) · Physical Therapy · doi:10.1093/ptj/84.11.1056 · Cited by 14
Nanofibrous PEDOT-Carbon Composite on Flexible Probes for Soft Neural Interfacing
Vajrala, V. S., Saunier, V., Nowak, L. G., Flahaut, E., Bergaud, C., & Maziz, A. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.780197 · Cited by 14
LiCl-induced sickness modulates rat gustatory cortical responses
Stone, B. T., Lin, J.-Y., Mahmood, A., Sanford, A. J., & Katz, D. B. (2022) · PLoS Biology · doi:10.1371/journal.pbio.3001537 · Cited by 14
“To evaluate whether a neuron was “held,” we performed a spike shape analysis the likes of which has been brought to bear in several previous studies [33,35,56,57].”
MethodDecoder remapping to counteract neuron loss in brain-machine interfaces
Héliot, R., Venkatraman, S., & Carmena, J. M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626694 · Cited by 13
“Despite of the impressive recording capabilities of the chronic, multi-site, multi-electrode technique [ 12 ], realworld BMI applications will require mechanisms to compensate for variability and loss of neurons over time.”
BackgroundSelf-citationOn linking human and machine brains
Warwick, K., & Ruiz, V. F. (2008) · Neurocomputing · doi:10.1016/j.neucom.2007.06.017 · Cited by 13
“The subject was asked to think about moving his hand and the operated unidirectionally [1,8].”
BackgroundFunctional dynamics of primate cortico-striatal networks during volitional movements
Santos, L. M., Opriș, I. C., Hampson, R. E., Godwin, D. W., Gerhardt, G. A., & Deadwyler, S. A. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00027 · Cited by 13
“…with task events (Figure 1A) were recorded simultaneously with the cells and synchronized on the same clock, using previously established methodology for cell and behavioral recordings (Nicolelis et al., 2003; Hampson et al., 2004; Dzirasa et al., 2006; Fetz, 2007; Santos et al., 2008, 2012).”
MethodDesign of a high-density multi-channel electrode for multi-structure parallel recordings in rodents
Ivica, N., Tamté, M., Ahmed, M., Richter, U., & Petersson, P. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943611 · Cited by 13
Qiao, S., Odoemene, O., & Yoshida, K. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0930-8 · Cited by 14
“Examining the similarity of spike waveform shape [13, 24, 27] combined with tracking interspike interval [5, 9] has been commonly used for the assessment of the chronic stability of singleunit recordings.”
MethodA WIRELESS MULTICHANNEL NEURAL RECORDING PLATFORM FOR REAL-TIME BRAIN MACHINE INTERFACES
Obeid, I. (2004) · Cited by 20
Decoding locomotion speed and slope from local field potentials of rat motor cortex
Mirfathollahi, A., Ghodrati, M. T., Shalchyan, V., & Daliri, M. R. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106961 · Cited by 12
Neural pathway connectivity and discharge changes between M1 and STN in hemiparkinsonian rats
Sun, S., Wang, X., Shi, X., Fang, H., Sun, Y., Li, M., Han, H., He, Q., Wang, X., Zhang, X., et al. (2023) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2023.03.002 · Cited by 12
“, Dallas, United States) and based on standard “spike sorting” procedures in previously published criteria (Nicolelis et al. 2003; Dodson et al. 2016; Geng, Xie, et al. 2016; Wang et al. 2016; Li et al. 2021; Pasquereau and Turner 2011b), including K-means supervised clustering algorithm , principle-component analysis…”
MethodSPKtool: An open source toolbox for electrophysiological data processing
Liu, X., Wu, X., & Liu, C. (2011) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2011.6098451 · Cited by 12
“A large amount of researches in Neuroscience is based on the study of the activity of neurons recorded extracellularly with microelectrodes implanted in animals’ brains [1-5].”
BackgroundStochastic Models for Multivariate Neural Point Processes: Collective Dynamics and Neural Decoding
Truccolo, W. (2010) · Springer eBooks · doi:10.1007/978-1-4419-5675-0_15 · Cited by 12
“…2003), retina and primary visual cortex (Pillow et al. , 2008; Jermakowicz et al. , 2009), and cortical sensorimotor areas in behaving non-human primates (Hatsopoulos et al. , 1998; Nicolelis et al. , 2003; Riehle et al. , 1997) and humans (Hochberg et al. , 2006; Truccolo et al. , 2008a,b, 2009).”
BackgroundTooker, A., Liu, D. F., Anderson, E. B., Felix, S. H., Shah, K. G., Lee, K. Y., Chung, J. E., Pannu, S. S., Frank, L. M., & Tolosa, V. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945197 · Cited by 12
“Traditionally, these micro-fabricated electrode arrays have been fabricated out of either silicon [5-7] or polymers [8-16], such as polyimide or parylene, since these materials are compatible with the MEMS-based fabrication processes needed to create the arrays.”
MethodAnalysis of Hippocampal Memory Replay Using Neural Population Decoding
Kloosterman, F. (2011) · Neuromethods · doi:10.1007/7657_2011_8 · Cited by 13
Neurosurgical access to cortical areas in the lateral fissure of primates
Hackett, T. A., Karmos, G., Schroeder, C. E., Ulbert, I., Sterbing-D’Angelo, S. J., D’Angelo, W. R., Kajikawa, Y., Blumell, S., & de la Mothe, L. A. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.06.001 · Cited by 12
McGie, S. C., Nagai, M. K., & Artinian-Shaheen, T. (2013) · IEEE Pulse · doi:10.1109/mpul.2013.2242014 · Cited by 13
“[14] have also strongly suggested that the use of softer, more flexible materials, such as stainless steel microwires [17], could further reduce mechanical damage.”
Pais, J. C., & Harvey, J. (2012) · CRC Press eBooks · doi:10.1201/b12767 · Cited by 17
Coupled variability in primary sensory areas and the hippocampus during spontaneous activity
de Vasconcelos, N. A. P., Soares‐Cunha, C., Rodrigues, A. J., Ribeiro, S. T. G., & Sousa, N. (2017) · Scientific Reports · doi:10.1038/srep46077 · Cited by 13
Nano-scale transistors for interfacing with brain: design criteria, progress and prospect
El‐Atab, N., Shaikh, S. F., & Hussain, M. M. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab3534 · Cited by 13
Multielectrode Recordings in the Somatosensory System
Wiest, M., Meloy, J., & Thomson, E. E. (2007) · Frontiers in neuroscience · doi:10.1201/9781420006414.ch6 · Cited by 12
Statistical characterization of an ensemble of functional neural networks
Silva, B. B. M., Miranda, J. G. V., Corso, G., Copelli, M., de Vasconcelos, N. A. P., Ribeiro, S. T. G., & Andrade, R. F. S. (2012) · The European Physical Journal B · doi:10.1140/epjb/e2012-30481-7 · Cited by 12
Chronic calcium imaging in neuronal development and disease
Aramuni, G., & Griesbeck, O. (2012) · Experimental Neurology · doi:10.1016/j.expneurol.2012.02.008 · Cited by 13
“electrode recordings for up to several months (Nicolelis et al., 2003).”
BackgroundOgnjanovski, N., Schaeffer, S., Wu, J., Mofakham, S., Maruyama, D., Żochowski, M., & Aton, S. J. (2017) · Nature Communications · doi:10.1038/ncomms16120 · Cited by 14
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Bansal, M., Vyas, Y., Aqrawe, Z., Raos, B. J., Cheah, E., Montgomery, J. M., Wu, Z., & Svirskis, D. M. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00231 · Cited by 13
Hayn, L., & Koch, M. (2015) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2015.08.001 · Cited by 12
A statistical description of neural ensemble dynamics
Long, J. D., & Carmena, J. M. (2011) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2011.00052 · Cited by 11
“generating datasets that record the output of ever increasing numbers of neurons (Nicolelis et al., 2003; Suner et al., 2005; Nicolelis, 2008).”
BackgroundSelf-citationAdhikari, S., Mukunda, N., Kumar, M. C. S., Sadhana, N., Narayanan, S. N., Kapgal, K. V., Avinash, H., Chandrashekar, B. R., Rao, K. R., & Nayak, S. B. (2013) · Brain Injury · doi:10.3109/02699052.2013.831121 · Cited by 11
Rogers, L. S., Wert, J. C. V., & Mensinger, A. F. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.06.012 · Cited by 11
Reed, J. L., Pouget, P., Qi, H., Zhou, Z., Bernard, M. R., Burish, M. J., & Kaas, J. H. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00414.2011 · Cited by 11
Nonlinear elastic brain tissue model for neural probe-tissue mechanical interaction
Hamzavi, N., Tsang, W. M., & Shim, V. P. W. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696134 · Cited by 11
“For example, a steady decrease in the number of remaining functional microwires electrodes over time has been reported [4] and may be caused by tissue response to the implants.”
An Actuated Neural Probe Architecture for Reducing Gliosis-Induced Recording Degradation
Massey, T. L., Kuo, L. S., Fan, J. L., & Maharbiz, M. M. (2019) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2019.2905468 · Cited by 12
Su, C., Chiang, C., Lee, C.-M., Fan, Y., Ho, C., & Shyu, L.-Y. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00149 · Cited by 13
“…recording techniques have been shown as a powerful tool to elucidate functional operations of cerebral cortical neurons (deCharms et al., 1999; Nicolelis et al., 2003; Tsytsarev et al., 2006; Galashan et al., 2011) and exemplify ensemble neuronal activities underlying somatic moto-sensory…”
MethodNeuron selection and visual training for population vector based cortical control
Wahnoun, R., Tillery, S. I. H., & He, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404277 · Cited by 11
“A significant effort in implementing cortical control of evices to date has been devoted to recording from as many eurons as possible [5, 6] and designing algorithms which xtract as much information from those neurons as possible 7].”
MethodEthical considerations for engineers working in cybernetic implants
Fox, K. E. (2013) · IEEE International Conference on Cybernetics (CYBCONF) · doi:10.1109/cybconf.2013.6617452 · Cited by 22
Shin, C. J., Lee, K., Langford, L., & Bai, W. (2025) · Small Methods · doi:10.1002/smtd.202501330 · Cited by 10
Slippery Epidural ECoG Electrode for High-Performance Neural Recording and Interface
Alahi, M. E. E., Liu, Y., Khademi, S., Nag, A., Wang, H., Wu, T., & Mukhopadhyay, S. C. (2022) · Biosensors · doi:10.3390/bios12111044 · Cited by 10
“Secondly, the glial scar can increase the electrode’s impedance and reduce the SNR, positively correlated with the noise [21,22].”
BackgroundDecoding grasp movement from monkey premotor cortex for real-time prosthetic hand control
Hao, Y., Zhang, Q., Zhang, S., Zhao, T., Wang, Y., Chen, W., & Zheng, X. (2013) · Chinese Science Bulletin · doi:10.1007/s11434-013-5840-0 · Cited by 11
Spatially Controlling Neuronal Adhesion and Inflammatory Reactions on Implantable Diamond
Regan, E. M., Taylor, A. C., Uney, J. B., Dick, A. D., May, P. W., & McGeehan, J. P. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174469 · Cited by 14
“Typically, around 40%–60% reductions in the number of active electrodes have been demonstrated in multiple animal studies over a six month period [4]–[7].”
BackgroundHuang, S.-H., Shmoel, N., Jankowski, M. M., Erez, H., Sharon, A., Abu-Salah, W., Nelken, I., Weiss, A. M., & Spira, M. E. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00926 · Cited by 12
“, 2015), the deterioration of the recording yield and quality is primarily attributed to inflammatory processes triggered and perpetuated by the implants that culminates histologically in chronic encapsulation of the probe by up to a 50–400 μm thick glial scar (Gray et al., 1995; Rousche and Normann, 1998; Kipke et al…”
BackgroundMultielectrode Recording in Behaving Monkeys
Nicolelis, M. A. L. (2007) · CRC Press eBooks · doi:10.1201/9781420006414-14 · Cited by 10
Self-citationCan histology solve the riddle of the nonfunctioning electrode?
Linsmeier, C. E., Thelin, J., & Danielsen, N. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00008-x · Cited by 11
Park, J. H., Kim, C.-E., Shin, J., Im, C., Koh, C. S., Seo, I. S., Kim, S. J., & Shin, H. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056009 · Cited by 10
“In chronic multi-channel recording, not all recorded unit activities can be expected to be stable during long-term (months to years) recording sessions (Nicolelis et al 2003).”
BackgroundBansal, A. K., Singer, J. M., Anderson, W. S., Golby, A. J., Madsen, J. R., & Kreiman, G. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00458.2012 · Cited by 10
“Several investigators have begun to use chronic multi-electrode arrays to record action potentials over periods spanning days or, in some cases, even months (e.g., Nicolelis et al. 2003; Porada et al. 2000).”
BackgroundFreire, M. A. M., Faber, J., Lemos, N. A. M., dos Santos, J. R., Cavalcanti, P. F., Lima, R. H., & Morya, E. (2015) · PLoS ONE · doi:10.1371/journal.pone.0130354 · Cited by 10
A high-sensitive detection method for carvone odor by implanted electrodes in rat olfactory bulb
Zhuang, L., Hu, N., Tian, F., Dong, Q., Hu, L., Li, R., & Wang, P. (2013) · Chinese Science Bulletin · doi:10.1007/s11434-013-0044-1 · Cited by 10
Miller, S. R., Yu, S. P., Pajevic, S., & Plenz, D. (2021) · Network Neuroscience · doi:10.1162/netn_a_00188 · Cited by 11
“…in neuronal activity using cellular resolution approaches (Dickey et al., 2009; Fraser and Schwartz, 2011; Jackson and Fetz, 2007; Li et al., 2017; Nicolelis et al., 2003; Tolias et al., 2007), cellular approaches suffer from spatial subsampling (Levina and Priesemann, 2017; Petermann et al.,…”
BackgroundMethodHow To Record a Million Synaptic Weights in a Hippocampal Slice
Bhalla, U. S. (2008) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000098 · Cited by 11
“Implanted extracellular electrodes have also been used to record from hundreds of isolated single units [18,19].”
BackgroundA Linear Discrimination Method Used in Motor Imagery EEG Classification
Xiao, D., Mu, Z., & Hu, J. (2009) · International Conference on Natural Computation (ICNC) · doi:10.1109/icnc.2009.252 · Cited by 10
“A brain– computer interface is a way of using an individual’s thought processes to control computer or electromechanical hardware without using overt muscle activities [1-3].”
MethodGuida, R., & Melodia, T. (2025) · Ad Hoc Networks · doi:10.1016/j.adhoc.2024.103748 · Cited by 9
Jiang, X., Sun, M., Yan, Y., Wang, Y., Fan, X., Wei, J., Wang, K., Liang, P., Wang, Z., Wang, J., et al. (2024) · Clinical and Translational Medicine · doi:10.1002/ctm2.70117 · Cited by 10
“28,29”
Wang, C., Yang, L., Lu, D., Lü, Y.-F., Chen, X., Yu, Y., Li, Z., Zhang, F.-K., Li, H., & Chen, J. (2011) · Behavioural Brain Research · doi:10.1016/j.bbr.2011.04.032 · Cited by 10
Férézou, I., Petersen, C. C. H., & Mátyás, F. (2009) · Frontiers in neuroscience · doi:10.1201/9781420076851.ch6 · Cited by 11
Conceptual and Technical Approaches to Human Neural Ensemble Recordings
Patil, P. G., Nicolelis, M. A. L., & Turner, D. A. (2007) · Frontiers in neuroscience · doi:10.1201/9781420006414.ch12 · Cited by 9
Self-citationGraudejus, O., Barton, C. D., Wong, R. D. P., Rowan, C. C., Oswalt, D. N., & Greger, B. E. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb4a5 · Cited by 9
Boergens, K. M., Tadić, A., Hopper, M. S., McNamara, I., Fell, D., Sahasrabuddhe, K., Kong, Y., Straka, M., Sohal, H. S., & Angle, M. R. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0585 · Cited by 9
Robotic multi-probe single-actuator inchworm neural microdrive
Smith, R. D., Kolb, I., Tanaka, S., Lee, A. K., Harris, T. D., & Barbic, M. (2022) · eLife · doi:10.7554/elife.71876 · Cited by 10
In Vivo Voltammetry with Telemetry
Garris, P. A., Greco, P. G., Sandberg, S. G., Howes, G., Pongmaytegul, S., Heidenreich, B. A., Casto, J. M., Ensman, R. E., Poehlman, J., Alexander, A., et al. (2006) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420005868.ch12 · Cited by 12
International Journal of Ethics in Engineering & Management Education
vision-i, P. (2014) · ADVANCED SCIENCES INDEX · Cited by 9
Héliot, R., & Carmena, J. M. (2010) · Elsevier eBooks · doi:10.1016/b978-0-08-045396-5.00209-8 · Cited by 9
Self-citation
Metadata
- Authors
- Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P.
- Affiliations
- Duke University (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-09-05
- Volume
- 100
- Issue
- 19
- Pages
- 11041-11046
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC196923
- OpenAlex
- W2095504054
- Cited by
- 740
- References
- 28
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 13 · 2023: 12 · 2022: 28 · 2021: 24 · 2020: 28 · 2019: 31 · 2018: 26 · 2017: 31 · 2016: 26 · 2015: 39 · 2014: 49 · 2013: 45 · 2012: 36
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Hispana (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- single-unit recording, macaque, rhesus monkeys, microwire arrays, multi-electrode recording, cortical neurons, neuroprosthetics, sensorimotor integration
- MeSH terms
- Action Potentials, Animals, Cerebral Cortex, Electrodes, Female, Macaca mulatta, Male
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.