Chronic, multisite, multielectrode recordings in macaque monkeys
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A paradigm is described for recording the activity of single cortical neurons from awake, behaving macaque monkeys. Its unique features include high-density microwire arrays and multichannel instrumentation. Three adult rhesus monkeys received microwire array implants, totaling 96–704 microwires per subject, in up to five cortical areas, sometimes bilaterally. Recordings 3–4 weeks after implantation yielded 421 single neurons with a mean peak-to-peak voltage of 115 ± 3 μV and a signal-to-noise ratio of better than 5:1. As many as 247 cortical neurons were recorded in one session, and at least 58 neurons were isolated from one subject 18 months after implantation. This method should benefit neurophysiological investigation of learning, perception, and sensorimotor integration in primates and the development of neuroprosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [340]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davies, D. L., & Bouldin, D. W. (1979) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1979.4766909 · Cited by 9,145
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,123
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Self-citationInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Dynamics of neuronal interactions in monkey cortex in relation to behavioural events
Vaadia, E., Haalman, I., Abeles, M., Bergman, H., Prut, Y., Slovin, H., & Aertsen, A. (1995) · Nature · doi:10.1038/373515a0 · Cited by 812
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
Self-citationDynamic organization of motor control within the olivocerebellar system
Welsh, J. P., Lang, E. J., Suglhara, I., & Llinás, R. (1995) · Nature · doi:10.1038/374453a0 · Cited by 685
Research works printed but not linked: 4
- Evarts, E. V. (1960) Fed. Proc. 19, Suppl. 4, 828–837.
- Davies, D. L. & Bouldin, D. W. (1979) IEEE Trans. Pattern Anal. Machine Intell. 1, 224-227.
- Woolsey, C. N., Settlage, P., Meyer, D. R., Sencer, W., Hamuy, T. P. & Travis, A. M. (1952) Res. Publ. Assoc. Res. Nerv. Ment. Dis. 30, 238-264.
- Mitz, A. R., Godschalk, M. & Wise, S. P. (1991) J. Neurosci. 1, 1855-1872.
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“The number of wires used in a single implanted array has ranged from 4 (Yuen and Agnew, 1995) to over 100 (Nicolelis et al., 2003).”
BackgroundMethodInfluentialBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Self-citationLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
“of the population remained stable for several weeks and, in some cases, months (Nicolelis et al. 2003).”
BackgroundMethodInfluentialSelf-citationAn Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206
Truccolo, W., Eden, U. T., Fellows, M. R., Donoghue, J. P., & Brown, E. N. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00697.2004 · Cited by 1,049
“Third, current capabilities to record the simultaneous activity of multiple single neurons (Csicsvari et al. 2003; Donoghue 2002; Nicolelis et al. 2003; Wilson and McNaughton 1993) make it possible to study the extent to which spiking activity in a given neuron is related to concurrent ensemble…”
BackgroundSwitching on and off fear by distinct neuronal circuits
Herry, C., Ciocchi, S., Senn, V., Demmou, L., Müller, C., & Lüthi, A. (2008) · Nature · doi:10.1038/nature07166 · Cited by 950
Encoding of conditioned fear in central amygdala inhibitory circuits
Ciocchi, S., Herry, C., Grenier, F., Wolff, S. B. E., Letzkus, J. J., Vlachos, I., Ehrlich, I., Sprengel, R., Deisseroth, K., Stadler, M. B., et al. (2010) · Nature · doi:10.1038/nature09559 · Cited by 924
Sensory substitution and the human-machine interface
Bach-y-Rita, P., & W. Kercel, S. (2003) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2003.10.013 · Cited by 858
“individual neurons in the brain, as required to understand complex neuronal processing [ 38 ].”
BackgroundGenetic dissection of an amygdala microcircuit that gates conditioned fear
Haubensak, W., Kunwar, P. S., Cai, H., Ciocchi, S., Wall, N. R., Ponnusamy, R., Biag, J., Dong, H.-W., Deisseroth, K., Callaway, E. M., et al. (2010) · Nature · doi:10.1038/nature09553 · Cited by 840
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Cognitive Enhancement: Methods, Ethics, Regulatory Challenges
Bostrom, N., & Sandberg, A. (2009) · Science and Engineering Ethics · doi:10.1007/s11948-009-9142-5 · Cited by 741
“…hardware side, where multielectrode recordings from more than 300 electrodes permanently implanted in the brain are currently state-of-the art, and on the software side, with computers learning to interpret the signals and commands (Nicolelis et al. 2003; Shenoy et al. 2003; Carmena et al. 2003).”
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
“The modern era of BMIs emerged precisely at the time the methods for chronic multi-electrode recordings were consolidated in rodents and started to make their transition to primates, first to New World monkeys (582, 852) and then to rhesus monkeys (114, 463, 580).”
BackgroundMethodSelf-citationUltraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
How advances in neural recording affect data analysis
Stevenson, I. H., & Kording, K. P. (2011) · Nature Neuroscience · doi:10.1038/nn.2731 · Cited by 582
“With current multiple-electrode technology, signals from hundreds of individual neurons can be recorded simultaneousl”
BackgroundA Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Emergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578
Self-citationSpontaneous cortical activity in awake monkeys composed of neuronal avalanches
Petermann, T., Thiagarajan, T. C., Lebedev, M. A., Nicolelis, M. A. L., Chialvo, D. R., & Plenz, D. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904089106 · Cited by 568
“Arrays of monopolar tungsten electrodes (30 m in diameter, 1 M impedance; 1-mm spacing) were chronically implanted into the cortex of two adult rhesus monkeys (Macaca mulatta) (33).”
MethodSelf-citationSchwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
Hazan, L., Zugaro, M., & Buzsáki, G. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.01.017 · Cited by 503
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Principles of neural ensemble physiology underlying the operation of brain–machine interfaces
Nicolelis, M. A. L., & Lebedev, M. A. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2653 · Cited by 483
Self-citationMaximum likelihood estimation of cascade point-process neural encoding models
Paninski, L. (2004) · Network: Computation in Neural Systems · doi:10.1088/0954-898x/15/4/002 · Cited by 481
“…power of this type of multineuronal model, even in the case of relatively few cells (by the most recent simultaneous recording standards (Warland et al 1997, Harris et al 2003, Nicolelis et al 2003)); we expect these techniques to play a larger role in future studies of population coding in vivo .”
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
“, [12], [33], and [34]) because of notable differences in animal models, surgical techniques, spike sorting techniques, and measurements of signal quality.”
BackgroundUsing a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode Arrays
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Joseph, M. D., Anderson, D. J., & Kipke, D. R. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90989.2008 · Cited by 420
Multifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
Abidian, M. R., Corey, J. M., Kipke, D. R., & Martin, D. C. (2010) · Small · doi:10.1002/smll.200901868 · Cited by 405
Control of Basal Ganglia Output by Direct and Indirect Pathway Projection Neurons
Freeze, B. S., Kravitz, A. V., Hammack, N., Berke, J. D., & Kreitzer, A. C. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1278-13.2013 · Cited by 405
“High-quality unit isolation was achieved, as assessed by measures of spike-sorting quality (Nicolelis et al., 2003; Davies–Bouldin index 0.30 0.02, J3 statistic 3.5 1.1, n 10 wires with multiple single units).”
MethodInfluentialThree-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
“The most common neural electrical probes are fabricated from metal 18 and silicon 19, 20 , materials that have very different structural and mechanical properties compared to brain tissue 21 .”
BackgroundSubbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
“We specifically focused on the microenvironment immediately adjacent to a microelectrode inserted in the cerebral cortex within the context of performance analysis of implantable microelectrode arrays used in research animals [4, 5, 13, 14, 26].”
MethodNanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K., Donoghue, J. P., Fraser, S. E., Lippincott-Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 356
Chronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys
Schwarz, D. A., Lebedev, M. A., Hanson, T. L., Dimitrov, D. F., Lehew, G., Meloy, J., Rajangam, S., Subramanian, V., Ifft, P. J., Li, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2936 · Cited by 348
Self-citationChallenges and opportunities for large-scale electrophysiology with Neuropixels probes
Steinmetz, N. A., Koch, C., Harris, K. D., & Carandini, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.009 · Cited by 333
“However, if the displacement of tissue and consequent damage to neurons and glia is deemed acceptable, a possible strategy is to insert dozens or hundreds of microwires, thus recording from large populations of neurons [9,10].”
BackgroundGlobal Forebrain Dynamics Predict Rat Behavioral States and Their Transitions
Gervasoni, D., Lin, S.-C., Ribeiro, S., Soares, E. S., Pantoja, J., & Nicolelis, M. A. L. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3524-04.2004 · Cited by 333
“Implants were guided by standard stereotaxic coordinates (Paxinos and Watson, 1998) and concurrent physiological recordings, as described previously (Nicolelis et al., 1997, 2003).”
MethodSelf-citationSelecting the signals for a brain–machine interface
Andersen, R. A., Musallam, S., & Pesaran, B. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.10.005 · Cited by 332
“Nonetheless, advances in electrode design are showing promising results in extending single-cell recording time [37–39].”
BackgroundBjornsson, C. S., Oh, S. J., Al-Kofahi, Y. A., Lim, Y. J., Smith, K. L., Turner, J. N., De, S., Roysam, B., Shain, W., & Kim, S. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/002 · Cited by 330
An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J., & Nurmikko, A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 321
Therapeutic Deep Brain Stimulation in Parkinsonian Rats Directly Influences Motor Cortex
Li, Q., Ke, Y., Chan, D. C. W., Qian, Z.-M., Yung, K. K. L., Ko, H., Arbuthnott, G. W., & Yung, W.-H. (2012) · Neuron · doi:10.1016/j.neuron.2012.09.032 · Cited by 312
“These evaluation indexes included the classic parametric F statistics of multivariate analysis of variance (MANOVA), the J3 and the Davies-Bouldin (DB) validity index (Nicolelis et al., 2003).”
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
“Keywords: Microelectrode Signal-to-noise ratio Disease Prosthesis Inflammation Epilepsy”
BackgroundInfluentialLebedev, M. A., Carmena, J. M., O'Doherty, J. E., Zacksenhouse, M., Henriquez, C. S., Principe, J. C., & Nicolelis, M. A. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4088-04.2005 · Cited by 290
Self-citationAdvanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
“Proof of concept for obtaining high-quality unit recordings for more than several months has been established through independent studies from several labs that collectively cover diverse types of microelectrode arrays implanted in rat, cat, and nonhuman primate (Rousche and Normann, 1998; Liu et al., 1999; Kipke et a…”
BackgroundInfluentialPhysical principles for scalable neural recording
Marblestone, A. H., Zamft, B. M., Maguire, Y. G., Shapiro, M. G., Cybulski, T. R., Glaser, J. I., Amodei, D., Stranges, P. B., Kalhor, R., Dalrymple, D. A., et al. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00137 · Cited by 240
“For example, the recording sites at the tip of a Utah or Duke multi-electrode array are typically viable in chronic recordings of up to 18 months in primates [61, 68], whereas in array formats with multiple electrodes along each shaft, such as the Michigan array, chronic recordings of up to 4 months have been reported…”
BackgroundSelf-citationBrain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
“Chronic implantation BCI investigations in monkeys and humans currently comprise four major classes of multi-unit electrodes: microwire arrays (Nicolelis et al., 2003; Taylor et al., 2002; Williams et al., 1999), silicon planar arrays (Hoogerwerf and Wise, 1994; Wise et al.”
BackgroundMethodInfluentialStrong adhesion of wet conducting polymers on diverse substrates
Inoue, A., Yuk, H., Lu, B., & Zhao, X. (2020) · Science Advances · doi:10.1126/sciadv.aay5394 · Cited by 260
Reversible large-scale modification of cortical networks during neuroprosthetic control
Ganguly, K., Dimitrov, D. F., Wallis, J. D., & Carmena, J. M. (2011) · Nature Neuroscience · doi:10.1038/nn.2797 · Cited by 259
Self-citationOkatan, M., Wilson, M. A., & Brown, E. N. (2005) · Neural Computation · doi:10.1162/0899766054322973 · Cited by 256
“With the advent of the multielectrode recording technology, it is now possible to record the activity of several hundred neurons simultaneously (Wilson & McNaughton, 1993; Nicolelis et al., 2003).”
BackgroundAbidian, M. R., Ludwig, K. A., Marzullo, T. C., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200900887 · Cited by 255
Brain–computer interface using fMRI: spatial navigation by thoughts
Yoo, S.-S., Fairneny, T., Chen, N.-K., Choo, S.-E., Panych, L. P., Park, H., Lee, S.-Y., & Jolesz, F. A. (2004) · NeuroReport · doi:10.1097/01.wnr.0000133296.39160.fe · Cited by 252
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
“Miniaturization of implants to mm and sub-mm dimensions can also open up the possibility of having a network of sensor nodes in body for applications such as multisite neural recording and stimulation [3], [4].”
BackgroundOgnjanovski, N., Schaeffer, S., Wu, J., Mofakham, S., Maruyama, D., Zochowski, M., & Aton, S. J. (2017) · Nature Communications · doi:10.1038/ncomms15039 · Cited by 229
“…clusters (across all groups) was 0.36 ± 0.02 ( for spike clusters versus spike clusters) and 0.46 ± 0.02 (for spike clusters versus noise), which compares favourably with DB values from single-unit data used in other studies 44,45 (distributions of discrimination values shown in Supplementary Fig.”
InfluentialRelationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Flexible polyimide microelectrode array for in vivo recordings and current source density analysis
Cheung, K. C., Renaud, P., Tanila, H., & Djupsund, K. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.035 · Cited by 230
“Using microwire rrays, Nicolelis et al. (2003) reported a steady drop in the umber of functional electrodes remaining over time, decreasing rom ∼100 initially implanted microwires to 421 recorded neuons after 3–4 weeks, ending with 58 neurons after 18 months in ne subject.”
Single-Unit Stability Using Chronically Implanted Multielectrode Arrays
Dickey, A. S., Suminski, A., Amit, Y., & Hatsopoulos, N. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90920.2008 · Cited by 234
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231
“scaling up from single to multi-channel electrodes, it is now possible to record spikes from well over 100 neurons [4], with the number of”
BackgroundIncorporating Feedback from Multiple Sensory Modalities Enhances Brain–Machine Interface Control
Suminski, A. J., Tkach, D. C., Fagg, A. H., & Hatsopoulos, N. G. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.3967-10.2010 · Cited by 231
“Over the past decade, substantial advances have been made in cortically controlled brain–machine interfaces (BMIs) in both animals and humans (Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Nicolelis et al., 2003; Kennedy et al., 2004; Musallam et al., 2004; Hochberg et al., 2006).”
BackgroundLewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
A new look at state-space models for neural data
Paninski, L., Ahmadian, Y., Ferreira, D. G., Koyama, S., Rahnama Rad, K., Vidne, M., Vogelstein, J., & Wu, W. (2010) · Journal of Computational Neuroscience · doi:10.1007/s10827-009-0179-x · Cited by 220
“.3 Example: inferring common input effects in multineuronal spike train recordings Recent developments in multi-electrode recording technology (Nicolelis et al. 2003; Litke et al. 2004) and fluorescence microscopy (Cossart et al. 2003; Ohki et al. 2005; Nikolenko et al. 2008) enable the…”
Elastocapillary self-assembled neurotassels for stable neural activity recordings
Guan, S., Wang, J., Gu, X., Zhao, Y., Hou, R., Fan, H., Zou, L., Gao, L., Du, M., Li, C., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav2842 · Cited by 222
Biomaterials for the central nervous system
Zhong, Y., & Bellamkonda, R. V. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0071 · Cited by 221
“These devices lose the ability to record neural activity within a few days or weeks after implantation (Edell et al. 1992; Liu et al. 1999; Cui et al. 2003; Nicolelis et al. 2003).”
BackgroundInfluentialStem cell-biomaterial interactions for regenerative medicine
Martino, S., D'Angelo, F., Armentano, I., Kenny, J. M., & Orlacchio, A. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.015 · Cited by 218
“Microfabricated electrodes for stimulating and recording signals from individual neurons that have facilitated direct electrical connections with living tissue is another important application (Nicolelis et al., 2003; Rousche and Normann, 1998).”
BackgroundKozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215
“This reactive tissue response degrades the functional performance of the electrode sites over time (Polikov et al 2005, Williams et al 1999, Rousche and Normann 1998, Ward et al 2009, Schwartz et al 2006, Nicolelis et al 2003, Liu et al 1999, 2006).”
BackgroundUltrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Patil, P. G., Carmena, J. M., Nicolelis, M. A. L., & Turner, D. A. (2004) · Neurosurgery · doi:10.1227/01.neu.0000126872.23715.e5 · Cited by 208
“These designs include silicon-based chip electrodes (20), the neurotrophic electrode (14, 15), and either fixed grid arrays of microwires (23) or loose microwires inserted as a bundle (10, 16).”
BackgroundMethodInfluentialSelf-citationPlasticity and stability of visual field maps in adult primary visual cortex
Wandell, B. A., & Smirnakis, S. M. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2741 · Cited by 207
Implantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
BSMART: A Matlab/C toolbox for analysis of multichannel neural time series
Cui, J., Xu, L., Bressler, S. L., Ding, M., & Liang, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.05.007 · Cited by 193
Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 191
“Electrodes implanted in humans are expected to function for a very long time, in some cases nearly a whole lifetime and human and primate studies have shown that electrodes can function for several years [12,13].”
BackgroundNeuronal encoding of the switch from specific to generalized fear
Ghosh, S., & Chattarji, S. (2015) · Nature Neuroscience · doi:10.1038/nn.3888 · Cited by 190
Kozai, T. D. Y., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.08.002 · Cited by 190
“For chronically implanted probes, one challenge is to improve and/or control the degree to which the probe integrates with the surrounding tissue to meet particular performance requirements, such as high signal-to-noise ratio and long-term stability (Liu et al., 2006; Nicolelis et al., 2003; Polikov et al., 2005; Rous…”
Victor, J. D. (2005) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2005.08.002 · Cited by 190
“Multineuronal cost-based metrics—Multineuronal recordings that enable the study of patterns of activity across neurons are increasingly available [17–19] and methods to analyze such data effectively are receiving increasing attention [20,21].”
BackgroundLe Van Quyen, M., Staba, R., Bragin, A., Dickson, C., Valderrama, M., Fried, I., & Engel, J. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.5049-09.2010 · Cited by 189
“With recent advances in bioengineering, chronically implanted arrays of microelectrodes are an increasingly common tool for recording many neurons from various mammalian species (Fried et al., 1997; Nicolelis et al., 2003; Buzsáki, 2004; Cash et al., 2009).”
BackgroundA Brain-Machine Interface Enables Bimanual Arm Movements in Monkeys
Ifft, P. J., Shokur, S., Li, Z., Lebedev, M. A., & Nicolelis, M. A. L. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006159 · Cited by 173
Self-citationExtracting kinematic parameters for monkey bipedal walking from cortical neuronal ensemble activity
Fitzsimmons, N. A. (2009) · Frontiers in Integrative Neuroscience · doi:10.3389/neuro.07.003.2009 · Cited by 186
Self-citationChronic multiunit recordings in behaving animals: advantages and limitations
Supèr, H., & Roelfsema, P. R. (2005) · Progress in Brain Research · doi:10.1016/s0079-6123(04)47020-4 · Cited by 183
“Recently, procedures have been developed to follow SUA by using chronically implanted electrodes (Nicolelis et al., 2003).”
BackgroundNeuronal Ensemble Bursting in the Basal Forebrain Encodes Salience Irrespective of Valence
Lin, S.-C., & Nicolelis, M. A. L. (2008) · Neuron · doi:10.1016/j.neuron.2008.04.031 · Cited by 176
“Detailed spike-sorting methods, as well as quantification of cluster separation, have been previously described (Nicolelis et al., 2003).”
MethodInfluentialSelf-citationAbiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
“…arrays (Drake et al., 1988; Rousche and Normann, 1998; Williams et al., 1999a,b; Rousche et al., 2001; Csicsvari et al., 2003; Kipke et al., 2003; Nicolelis et al., 2003; Vetter et al., 2004; Patrick et al., 2006; Jackson and Fetz, 2007; Musallam et al., 2007; Kozai et al., 2012a; Kim et al.,…”
BackgroundYang, T., Kim, J. R., Jin, H., Gil, H., Koo, J., & Kim, H. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008831 · Cited by 178
Winslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
Highly Stretchable Gold Nanobelts with Sinusoidal Structures for Recording Electrocorticograms
Qi, D., Liu, Z., Yu, M., Liu, Y., Tang, Y., Lv, J., Li, Y., Wei, J., Liedberg, B., Yu, Z., et al. (2015) · Advanced Materials · doi:10.1002/adma.201405807 · Cited by 175
Decoding of Temporal Intervals From Cortical Ensemble Activity
Lebedev, M. A., O'Doherty, J. E., & Nicolelis, M. A. L. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00734.2007 · Cited by 178
“In this study, we conducted simultaneous multielectrode recordings from multiple cortical areas (Nicolelis et al. 2003) to test the hypothesis that predictions of motor timing can be extracted from the activity of large ensembles of cortical neurons recorded in motor and premotor cortex in rhesus…”
MethodSelf-citationImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
“1 Penetrating cortical electrodes Microwires [76, 108, 146, 168]”
MethodInfluentialCompact Movable Microwire Array for Long-Term Chronic Unit Recording in Cerebral Cortex of Primates
Jackson, A., & Fetz, E. E. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00569.2007 · Cited by 173
“This improvement is also evident in the mean peak-to-peak amplitude (248 V) compared with that of fixed microwires (115 V; Nicolelis et al. 2003).”
BackgroundInfluentialA brain-machine interface instructed by direct intracortical microstimulation
O'Doherty, J. E. (2009) · Frontiers in Integrative Neuroscience · doi:10.3389/neuro.07.020.2009 · Cited by 172
Self-citationEnergy Harvesting and Remote Powering for Implantable Biosensors
Olivo, J., Carrara, S., & De Micheli, G. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2085042 · Cited by 167
“A promising application is the use of implanted electrode arrays to monitor local neural circuits and the related spiking activity [1–4].”
Recording Chronically From the Same Neurons in Awake, Behaving Primates
Tolias, A. S., Ecker, A. S., Siapas, A. G., Hoenselaar, A., Keliris, G. A., & Logothetis, N. K. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00260.2007 · Cited by 175
“Previous studies have reported recording stability across days based on similarity between action potential waveforms (Greenberg and Wilson 2004; Rousche and Normann 1998; Schmitzer-Torbert and Redish 2004; Taylor et al. 2002; Wilson et al. 2003) or waveform features (Nicolelis et al. 2003).”
BackgroundNeural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
“8 – 10 kHz) action potential (AP) or spiking events (∼100 μV) associated with the discharge of individual neurons in the vicinity of the electrode [6].”
BackgroundSelf-citationWinslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171
Pathobiology of Human Cerebrovascular Malformations: Basic Mechanisms and Clinical Relevance
Gault, J., Sarin, H., Awadallah, N. A., Shenkar, R., & Awad, I. A. (2004) · Neurosurgery · doi:10.1227/01.neu.0000440729.59133.c9 · Cited by 170
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
“, 1999) over 18 and 84 months in motor cortex of macaques (Nicolelis et al., 2003), even seven years in monkeys (Krüger et al.”
BackgroundInfluentialQuantifying long-term microelectrode array functionality using chronic in vivo impedance testing
Prasad, A., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026028 · Cited by 157
Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 162
Techniques for extracting single-trial activity patterns from large-scale neural recordings
Churchland, M. M., Yu, B. M., Sahani, M., & Shenoy, K. V. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2007.11.001 · Cited by 166
“There are thus a variety of motivations for large-scale simultaneous recordings using arrays of electrodes [1-4].”
Stable Ensemble Performance with Single-Neuron Variability during Reaching Movements in Primates
Carmena, J. M., Lebedev, M. A., Henriquez, C. S., & Nicolelis, M. A. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2772-05.2005 · Cited by 163
Self-citationPrimate Reaching Cued by Multichannel Spatiotemporal Cortical Microstimulation
Fitzsimmons, N. A., Drake, W., Hanson, T. L., Lebedev, M. A., & Nicolelis, M. A. L. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.5297-06.2007 · Cited by 163
“With the development of multielectrode implants (Nicolelis et al., 2003) and the concurrent advances of brain–machine interfaces (Chapin et al.”
BackgroundSelf-citation
Metadata
- Authors
- Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P.
- Affiliations
- Duke University (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-09-05
- Volume
- 100
- Issue
- 19
- Pages
- 11041-11046
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC196923
- OpenAlex
- W2095504054
- Cited by
- 740
- References
- 28
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 13 · 2023: 12 · 2022: 28 · 2021: 24 · 2020: 28 · 2019: 31 · 2018: 26 · 2017: 31 · 2016: 26 · 2015: 39 · 2014: 49 · 2013: 45 · 2012: 36
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Hispana (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- single-unit recording, macaque, rhesus monkeys, microwire arrays, multi-electrode recording, cortical neurons, neuroprosthetics, sensorimotor integration
- MeSH terms
- Action Potentials, Animals, Cerebral Cortex, Electrodes, Female, Macaca mulatta, Male
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.