Chronic, multisite, multielectrode recordings in macaque monkeys
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A paradigm is described for recording the activity of single cortical neurons from awake, behaving macaque monkeys. Its unique features include high-density microwire arrays and multichannel instrumentation. Three adult rhesus monkeys received microwire array implants, totaling 96–704 microwires per subject, in up to five cortical areas, sometimes bilaterally. Recordings 3–4 weeks after implantation yielded 421 single neurons with a mean peak-to-peak voltage of 115 ± 3 μV and a signal-to-noise ratio of better than 5:1. As many as 247 cortical neurons were recorded in one session, and at least 58 neurons were isolated from one subject 18 months after implantation. This method should benefit neurophysiological investigation of learning, perception, and sensorimotor integration in primates and the development of neuroprosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [340]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davies, D. L., & Bouldin, D. W. (1979) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1979.4766909 · Cited by 9,145
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0626 · Cited by 4,674
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,123
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Self-citationInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Dynamics of neuronal interactions in monkey cortex in relation to behavioural events
Vaadia, E., Haalman, I., Abeles, M., Bergman, H., Prut, Y., Slovin, H., & Aertsen, A. (1995) · Nature · doi:10.1038/373515a0 · Cited by 812
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
Self-citationDynamic organization of motor control within the olivocerebellar system
Welsh, J. P., Lang, E. J., Suglhara, I., & Llinás, R. (1995) · Nature · doi:10.1038/374453a0 · Cited by 685
Research works printed but not linked: 4
- Evarts, E. V. (1960) Fed. Proc. 19, Suppl. 4, 828–837.
- Davies, D. L. & Bouldin, D. W. (1979) IEEE Trans. Pattern Anal. Machine Intell. 1, 224-227.
- Woolsey, C. N., Settlage, P., Meyer, D. R., Sencer, W., Hamuy, T. P. & Travis, A. M. (1952) Res. Publ. Assoc. Res. Nerv. Ment. Dis. 30, 238-264.
- Mitz, A. R., Godschalk, M. & Wise, S. P. (1991) J. Neurosci. 1, 1855-1872.
Cited by
Items 201–300 of 749
A Large-Scale Semi-Chronic Microdrive Recording System for Non-Human Primates
Dotson, N. M., Hoffman, S. J., Goodell, B., & Gray, C. M. (2017) · Neuron · doi:10.1016/j.neuron.2017.09.050 · Cited by 72
Lee, W., Kim, S., Kim, B., Lee, C., Chung, Y. A., Kim, L., & Yoo, S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178476 · Cited by 69
Inferring Neuronal Network Connectivity from Spike Data: A Temporal Data Mining Approach
Patnaik, D., SASTRY, P. S., & Unnikrishnan, K. P. (2008) · Scientific Programming · doi:10.1155/2008/324626 · Cited by 72
Refinement of learned skilled movement representation in motor cortex deep output layer
Li, Q., Ko, H., Qian, Z., Yan, L. Y. C., Chan, D. C. W., Arbuthnott, G. W., Ke, Y., & Yung, W. (2017) · Nature Communications · doi:10.1038/ncomms15834 · Cited by 77
Bioimpedance modeling to monitor astrocytic response to chronically implanted electrodes
McConnell, G. C., Butera, R. J., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055005 · Cited by 69
Progress in the Field of Micro-Electrocorticography
Shokoueinejad, M., Park, D., Jung, Y. H., Brodnick, S. K., Novello, J., Dingle, A. M., Swanson, K. I., Baek, D.-H., Suminski, A. J., Lake, W. B., et al. (2019) · Micromachines · doi:10.3390/mi10010062 · Cited by 72
“3D array N/A Stainless Or Tungsten 50 μm × 50 μm Teflon coated Single cortical neurons (monkey) [72] (2003) 3D array N/A Tungsten 35 μm2 Cerebral cortex (rat) [73] (1999) Michigan Assembled 3D array Si Ir 100 μm2, 2 MΩ LFP [74] (2000)”
MethodSensory Cortical Population Dynamics Uniquely Track Behavior across Learning and Extinction
Moran, A., & Katz, D. B. (2014) · Journal of Neuroscience · doi:10.1523/jneurosci.3331-13.2014 · Cited by 69
“Evaluation of single-neuron stability across days To determine whether a waveform recorded from a single electrode for multiple sessions represented the same single neuron, we used a spike shape analysis brought to bear successfully in several previous studies (Nicolelis et al., 2003; Grossman et al., 2008; Herry et a…”
MethodWestwick, D. T., Pohlmeyer, E. A., Solla, S. A., Miller, L. E., & Perreault, E. J. (2005) · Neural Computation · doi:10.1162/089976606775093855 · Cited by 72
“Recent advances in microelectrode array technology have made it possible to record from multiple neurons simultaneously (Maynard, Nordhausen, & Normann, 1997; Williams, Rennaker, & Kipke, 1999; Nicolelis et al., 2003).”
BackgroundZhang, S., Song, Y., Wang, M., Zhang, Z., Fan, X., Song, X., Zhuang, P., Yue, F., Chan, P., & Cai, X. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.04.087 · Cited by 65
A Review: Research Progress of Neural Probes for Brain Research and Brain–Computer Interface
Luo, J., Xue, N., & Chen, J. (2022) · Biosensors · doi:10.3390/bios12121167 · Cited by 66
“increases, the distance between the microwire electrodes cannot be precisely controlled during arrangement so that the consistency of electrode performance cannot be guaranteed, and electrode arrays assembly is also not easy to achieve [34].”
BackgroundBrain–computer interfaces: an overview of the hardware to record neural signals from the cortex
Stieglitz, T., Rubehn, B., Henle, C., Kisban, S., Herwik, S., Ruther, P., & Schüettler, M. (2009) · Progress in brain research · doi:10.1016/s0079-6123(09)17521-0 · Cited by 72
“Selfmade screw drives might allow adjustment in acute and chronic implantations, which have been made with up to 740 wires in a single cortex (Nicolelis et al., 2003).”
BackgroundInfluentialReed, J. L., Qi, H., & Kaas, J. H. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.4310-10.2011 · Cited by 68
“…(Plexon), was used to verify the quality of unit isolation such that single units had refractory periods 1.2 ms, p 0.05 for multivariate ANOVA related to cluster separation, and distinct waveform amplitudes and shapes when compared with other activity on the same electrode (Nicolelis et al., 2003).”
BackgroundMethodInfluentialShort and long term biocompatibility of NeuroProbes silicon probes
Grand, L., Wittner, L., Herwik, S., Göthelid, E., Ruther, P., Oscarsson, S. O., Neves, H. P., Dombovári, B., Csercsa, R., Karmos, G., et al. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.009 · Cited by 74
Combinatorial Responses Controlled by Synaptic Inhibition in the Cerebellum Granular Layer
Mapelli, J., Gandolfi, D., & D'Angelo, E. U. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00642.2009 · Cited by 68
Flexible and Organic Neural Interfaces: A Review
Lago, N., & Cester, A. (2017) · Applied Sciences · doi:10.3390/app7121292 · Cited by 69
“(a) Reproduced with permission from [100], Copyright 2003 National Academy of Sciences; (b) Reprinted from [101].”
MethodLong-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
Let There Be Light—Optoprobes for Neural Implants
Alt, M. T., Fiedler, E., Rudmann, L., Ordonez, J. S., Ruther, P., & Stieglitz, T. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2577518 · Cited by 68
Cassar, I. R., Yu, C., Sambangi, J., Lee, C. D., Whalen, J. J., Petrossians, A., & Grill, W. M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.017 · Cited by 66
Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality
Purcell, E. K., Thompson, D. E., Ludwig, K. A., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.026 · Cited by 62
McMahon, D. B. T., Bondar, I. V., Afuwape, O. A. T., Ide, D. C., & Leopold, D. A. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00052.2014 · Cited by 63
“Since the final output of the nervous system is driven by the coordinated action of neuronal circuits, the advantage of monitoring populations of neurons simultaneously is widely recognized (Alivisatos et al. 2012; Churchland et al. 2007; Cohen and Maunsell 2009; Nicolelis et al. 2003).”
BackgroundReduction of Single-Neuron Firing Uncertainty by Cortical Ensembles during Motor Skill Learning
Cohen, D., & Nicolelis, M. A. L. (2004) · Journal of Neuroscience · doi:10.1523/jneurosci.5361-03.2004 · Cited by 69
“At the end of the recording, cells were resorted using an off-line sorting algorithm (Plexon Inc.) to further confirm the quality of the recorded cells (Nicolelis et al., 2003).”
BackgroundMethodSelf-citationA Method for Detection and Classification of Events in Neural Activity
Bokil, H., Pesaran, B., Andersen, R. A., & Mitra, P. P. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.877802 · Cited by 62
“However, recent advances in chronic recording and implantation techniques [2], [3] have increased the attempts to base predictions upon cortical activity recorded from implanted electrodes [4]–[6] instead of the EEG.”
BackgroundSkousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61
Neural Probes for Chronic Applications
Kook, G., Lee, S., Lee, H., Cho, I., & Lee, H. J. (2016) · Micromachines · doi:10.3390/mi7100179 · Cited by 69
“While some studies reported that fast insertion in the order of m/s is preferred because of less stiction to the neighboring tissues and less dural dimpling [80,99,100], some studies claimed that slow insertion in the order of μm/s was the key factor that led to successful recording [89].”
BackgroundSuarez-Perez, A., Gabriel, G., Rebollo, B., Illa, X., Guimerà‐Brunet, A., Hernández‐Ferrer, J., Martínez, M. T., Villa, R., & Sanchez-Vives, M. V. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00862 · Cited by 65
Chawla, M. K., Lin, G., Olson, K., Vazdarjanova, A. I., Burke, S. N., McNaughton, B. L., Worley, P. F., Guzowski, J. F., Roysam, B., & Barnes, C. A. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.04.017 · Cited by 61
“In contrast, multi-neuron recording studies (Barnes et al., 1997; Gothard et al., 1996; Hoffman and McNaughton, 2002; Nicolelis et al., 1997, 2003; Wilson and McNaughton, 1993) provide the necessary cellular and temporal resolution, but are severely limited in terms of the number of neurons that…”
BackgroundChronic in vivo multi-circuit neurophysiological recordings in mice
Dzirasa, K., Fuentes, R., Kumar, S., Potes, J. M., & Nicolelis, M. A. L. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.11.014 · Cited by 57
Self-citationPlasticity in the Visual System
Pinaud, R., Tremere, L. A., & Weerd, P. D. (2006) · Springer eBooks · doi:10.1007/0-387-28190-8 · Cited by 61
Host response to microgel coatings on neural electrodes implanted in the brain
Gutowski, S. M., Templeman, K. L., South, A. B., Gaulding, J. C., Shoemaker, J. T., LaPlaca, M. C., Bellamkonda, R. V., Lyon, L. A., & García, A. J. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34799 · Cited by 57
Decoding the rat forelimb movement direction from epidural and intracortical field potentials
Slutzky, M. W., Jordan, L. R., Lindberg, E. W., Lindsay, K. E., & Miller, L. E. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036013 · Cited by 58
“Nicolelis et al [56] and Jackson and Fetz [57] found similar results at 1 week and even less stability (10% in the 2007 study) at 2 weeks.”
ResultLong-Term Neural Correlates of Reversible Fear Learning in the Lateral Amygdala
An, B., Hong, I., & Choi, S. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.3017-12.2012 · Cited by 54
“…to within-cluster density calculated in a principal component space, and the DB is the ratio between the sum of within-cluster density to the degree of separation between clusters, and thus a high J3 and low DB value indicates a compact, well separated unit cluster (Nicolelis et al., 2003).”
BackgroundCutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 60
Krüger, H., Brockmann, M. D., Salamon, J., Ittrich, H., & Hanganu‐Opatz, I. L. (2012) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2012.04.001 · Cited by 62
“As detailed previously (Nicolelis et al., 2003), the stored signals were”
BackgroundGraudejus, O., Yu, Z., Jones, J., Morrison, B., & Wagner, S. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3115465 · Cited by 58
Minnikanti, S., Skeath, P. R., & Peixoto, N. (2008) · Carbon · doi:10.1016/j.carbon.2008.11.045 · Cited by 60
A hybrid silicon–parylene neural probe with locally flexible regions
Kim, E. G. R., John, J. K., Tu, H., Zheng, Q., Loeb, J. A., Zhang, J., & Xu, Y. P. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.01.048 · Cited by 66
Inductive Power Link for a Wireless Cortical Implant With Two-Body Packaging
Silay, K. M., Dehollain, C., & Declercq, M. J. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2170676 · Cited by 59
“Another potential application is to use a cortical implant for in vivo recording of the neural activity of the brain, in order to realize brain-machine interfaces [4]–[8].”
BackgroundLiu, J., Bibari, O., Mailley, P., Dijon, J., Rouvière, E., Sauter-Starace, F., Caillat, P., Vinet, F., & Marchand, G. (2008) · New Journal of Chemistry · doi:10.1039/b813085j · Cited by 56
Joo, H. R., Fan, J. L., Chen, S., Pebbles, J. A., Liang, H., Chung, J. E., Yorita, A. M., Tooker, A. C., Tolosa, V. M., Geaghan-Breiner, C., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab2b2e · Cited by 54
“Classically, electrode arrays have been made of silicon (D. Kipke, 2003, Rousche and Normann, 1998) or other hard metal (Nicolelis et al., 2003).”
BackgroundNovel diamond shuttle to deliver flexible neural probe with reduced tissue compression
Na, K., Sperry, Z. J., Lu, J., Vöröslakos, M., Parizi, S. S., Bruns, T. M., Yoon, E., & Seymour, J. P. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0149-z · Cited by 60
Maximum Entropy Approaches to Living Neural Networks
Yeh, F.-C., Tang, A., Hobbs, J., Hottowy, P., Dąbrowski, W., Sher, A., Litke, A. M., & Beggs, J. M. (2010) · Entropy · doi:10.3390/e12010089 · Cited by 63
“Ideally, one would like to apply the model to ensembles of N ≥ 100 neurons, as many current experiments are based on simultaneous recordings from populations of this size [7,10,11,43].”
MethodComputing Arm Movements with a Monkey Brainet
Ramakrishnan, A., Ifft, P. J., Pais-Vieira, M., Byun, Y. W., Zhuang, K. Z., Lebedev, M. A., & Nicolelis, M. A. L. (2015) · Scientific Reports · doi:10.1038/srep10767 · Cited by 54
“They were chronically implanted with multielectrode arrays in motor (M1) and somatosensory cortices (S1) 1,35 .”
MethodSelf-citationTseng, W.-T., Yen, C., & Tsai, M. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.08.028 · Cited by 54
“, 2007), microarrays (Nicolelis et al., 2003), microelectrode bundles (Herry et al.”
BackgroundAristovich, K. Y., Donegà, M., Blochet, C., Avery, J., Hannan, S., Chew, D. J., & Holder, D. S. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aad78e · Cited by 57
“Mathematical models may be constructed of the information processing of spikes and refined and verified using electrophysiological measures of spiking activity using multielectrode arrays [1].”
BackgroundMaking the lifetime connection between brain and machine for restoring and enhancing function
Kennedy, P., Andreasen, D., Bartels, J., Ehirim, P., Mao, H., Velliste, M., Wichmann, T., & Wright, J. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00020-0 · Cited by 54
“The 5-year life span to date of the NE is clearly a step in the right direction, however, and is substantially longer than that of other types of electrodes in humans (Hochberg et al., 2006) or monkeys (Carmena et al., 2003, Nicolelis et al., 2003; reviewed by Kennedy, 2006).”
BackgroundToward a whole-body neuroprosthetic
Lebedev, M., & Nicolelis, M. A. L. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00018-2 · Cited by 62
Self-citationMcConnell, G. C., Schneider, T. M., Owens, D. J., & Bellamkonda, R. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895373 · Cited by 53
Hartung, H., Brockmann, M. D., Pöschel, B., De Feo, V., & Hanganu-Opatz, I. L. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.3232-15.2016 · Cited by 53
“As detailed previously (Nicolelis et al., 2003), the stored signals were sorted into similar waveform shapes using the Offline Sorter software (Plexon).”
MethodKhilwani, R., Gilgunn, P. J., Kozai, T. D. Y., Ong, X. C., Korkmaz, E., Gunalan, P. K., Cui, X. T., Fedder, G. K., & Özdoğanlar, O. B. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0125-4 · Cited by 56
Wiest, M., Bentley, N., & Nicolelis, M. A. L. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00556.2004 · Cited by 52
Self-citationA wireless subdural-contained brain–computer interface with 65,536 electrodes and 1,024 channels
Jung, T., Zeng, N., Fabbri, J. D., Eichler, G., Li, Z., Zabeh, E., Das, A., Willeke, K. F., Wingel, K., Dubey, A., et al. (2025) · Nature Electronics · doi:10.1038/s41928-025-01509-9 · Cited by 59
Jacobson, G. A., Lev, I., Yarom, Y., & Cohen, D. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806661106 · Cited by 53
“The surgical procedures have previously been described in detail (37, 38).”
MethodGraudejus, O., Morrison, B., Goletiani, C., Yu, Z., & Wagner, S. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201102290 · Cited by 50
Neural Correlates of Skill Acquisition with a Cortical Brain–Machine Interface
Ganguly, K., & Carmena, J. M. (2010) · Journal of Motor Behavior · doi:10.1080/00222895.2010.526457 · Cited by 49
“in the more likely scenario in which subsets of neurons are stable across time (Ganguly & Carmena, 2009; Nicolelis et al., 2003; Taylor et al., 2002), it is important to consider”
BackgroundSelf-citationPais-Vieira, M., Lebedev, M. A., Wiest, M. C., & Nicolelis, M. A. L. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1659-12.2013 · Cited by 49
Self-citationReal-time tracking of neuronal network structure using data assimilation
Hamilton, F., Berry, T., Peixoto, N., & SAUER, T. D. (2013) · Physical Review E · doi:10.1103/physreve.88.052715 · Cited by 50
Reed, J. L., Qi, H.-X., Zhou, Z., Bernard, M. R., Burish, M. J., Bonds, A. B., & Kaas, J. H. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00709.2009 · Cited by 49
Artificial dural sealant that allows multiple penetrations of implantable brain probes
Jackson, N., & Muthuswamy, J. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.02.018 · Cited by 52
“There have been many advances in electrode design over the past years that have allowed for longer lasting devices and better recordings (Moxon et al., 2004; Muthuswamy et al., 2005b; Nicolelis et al., 2003; Nordhausen et al., 1996; Rousche et al., 2001; Vetter et al., 2004).”
BackgroundLong-term stability of sensitivity to intracortical microstimulation of somatosensory cortex
Callier, T., Schluter, E. W., Tabot, G. A., Miller, L. E., Tenore, F. V., & Bensmaia, S. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056010 · Cited by 48
The functional consequences of chronic, physiologically effective intracortical microstimulation
Parker, R. A., Davis, T. S., House, P. A., Normann, R. A., & Greger, B. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00010-8 · Cited by 47
“Numerous studies have also demonstrated the utility of MEAs for intracortical motor prosthetic applications in nonhuman primates (Aggarwal et al., 2009; Musallam, 2004; Nicolelis, 2003; Santhanam et al., 2006; Schwartz et al., 2006; Taylor, 2002; Wessberg, 2000).”
BackgroundFeingold, J., Desrochers, T. M., Fujii, N., Harlan, R., Tierney, P. L., Shimazu, H., Amemori, K., & Graybiel, A. M. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00625.2011 · Cited by 52
“Second, chronically implanted arrays of immovable electrodes have increased rates of data acquisition by at least one order of magnitude over acute single-electrode techniques (Nicolelis et al. 2003; Nordhausen et al. 1996; Suner et al. 2005; Vetter et al. 2004; Ward et al. 2009).”
BackgroundMethodPowering and communicating with mm-size implants
Rabaey, J. M., Mark, M., Chen, D., Sutardja, C., Tang, C., Gowda, S., Wagner, M., & Werthimer, D. (2011) · 2011 Design, Automation & Test in Europe · doi:10.1109/date.2011.5763123 · Cited by 46
Developing Next-Generation Brain Sensing Technologies—A Review
Robinson, J. T., Xie, C., Pohlmeyer, E. A., Gather, M. C., Kemere, C. T., Kitching, J. E., Malliaras, G. G., Marblestone, A. H., Shepard, K. L., & Stieglitz, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2931159 · Cited by 50
Nyquist interpolation improves neuron yield in multiunit recordings
Blanche, T. J., & Swindale, N. V. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.12.031 · Cited by 49
“The advent of multisite, ultiunit electrodes such as tetrodes (Gray et al., 1995), multiire electrode arrays (Nicolelis et al., 2003), and silicon-based olytrodes (Bai et al., 2000; Blanche et al., 2005; Campbell et l., 1991; Csicsvari et al., 2003) has made it possible to record rom many neurons…”
BackgroundMethodInfluentialHomayoun, H., & Moghaddam, B. (2009) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2009.06679.x · Cited by 54
“J3 and pseudoF statistics, and Davies–Bouldin validity index were used, on a case-by-case basis, to assess the quality of separation between identified clusters and the effects of incremental increases or decreases on the number of units isolated from a channel (Nicolelis et al., 2003).”
Comparing temporal aspects of visual, tactile, and microstimulation feedback for motor control
Godlove, J. M., Whaite, E. O., & Batista, A. P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046025 · Cited by 44
“Cortically controlled brain-computer interfaces (BCIs) were first demonstrated over ten years ago in humans and monkeys [1, 2, 3, 4].”
BackgroundPhysiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 46
“These signals are obtained with the use of multielectrode arrays, most often either silicon shanks (Rousche and Normann 1998; Subbaroyan et al. 2005) or assembled from metal microwires (Nicolelis et al. 2003; Schwarz et al. 2014).”
BackgroundCoherence Potentials: Loss-Less, All-or-None Network Events in the Cortex
Thiagarajan, T. C., Lebedev, M., Nicolelis, M. A. L., & Plenz, D. (2010) · PLoS Biology · doi:10.1371/journal.pbio.1000278 · Cited by 53
“impedance; 1 mm spacing) were chronically implanted into the cortex of two adult rhesus monkeys (Macaca mulatta) [79].”
MethodSelf-citationBuch, E. R., Brasted, P. J., & Wise, S. P. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-0130-y · Cited by 51
“Although new methods will make the latter approach feasible in future studies (Laubach et al. 2000; Nicolelis et al. 2003), we did not attempt to use those methods in this one.”
MethodSelf-citationNeurotechnologies to restore hand functions
Losanno, E., Mender, M. J., Chestek, C. A., Shokur, S., & Micera, S. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00054-4 · Cited by 49
Gu, X., Yeung, S. Y., Chadda, A., Poon, E. N.-Y., Boheler, K. R., & Hsing, I. (2018) · Advanced Biosystems · doi:10.1002/adbi.201800248 · Cited by 48
A miniaturized chronic microelectrode drive for awake behaving head restrained mice and rats
Haiss, F., Butovas, S., & Schwarz, C. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.12.015 · Cited by 45
Schormans, A. L., Typlt, M., & Allman, B. L. (2016) · Hearing Research · doi:10.1016/j.heares.2016.06.017 · Cited by 48
“Furthermore, single-units were identified if they formed a discrete cluster in 2D/3D spaces that were separate from clusters of other units and/or multi-unit activity (Nicolelis et al., 2003).”
InfluentialNovel Approaches to Monitor and Manipulate Single Neurons In Vivo
Brecht, M., Fee, M. S., Garaschuk, O., Helmchen, F., Margrie, T. W., Svoboda, K., & Osten, P. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3344-04.2004 · Cited by 45
“…and microdrive techniques have led to the ability to record from many neurons in freely behaving animals (Bragin et al., 2000; Serruya et al., 2002; Nicolelis et al., 2003), many challenges remain in the effort to develop chronic recording systems with the flexibility and selectivity of acute…”
BackgroundThe neural tissue around SU-8 implants: A quantitative in vivo biocompatibility study
Márton, G., Tóth, E. Z., Wittner, L., Fiáth, R., Pinke, D., Orbán, G., Meszéna, D., Pál, I., Győri, E. L., Bereczki, Z., et al. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.110870 · Cited by 46
Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study
Sanchez, J. C., Alba, N., Nishida, T., Batich, C., & Carney, P. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875581 · Cited by 45
Neurotechnological Approaches to the Diagnosis and Treatment of Alzheimer’s Disease
Ning, S., Jorfi, M., Patel, S. R., Kim, D. Y., & Tanzi, R. E. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.854992 · Cited by 49
Angelov, S. D., Koenen, S., Jakobi, J., Heissler, H. E., Alam, M., Schwabe, K., Barcikowski, S., & Krauss, J. K. (2016) · Journal of Nanobiotechnology · doi:10.1186/s12951-015-0154-9 · Cited by 45
“The impedance and the current distribution also depend on the response of the neural tissue around the electrode contact, especially reactive gliosis and neuronal loss [18–23].”
BackgroundAnalysis of neuronal ensemble activity reveals the pitfalls and shortcomings of rotation dynamics
Lebedev, M. A., Ossadtchi, A., Mill, N. A., Urpí, N. A., Cervera, M. R., & Nicolelis, M. A. L. (2019) · Scientific Reports · doi:10.1038/s41598-019-54760-4 · Cited by 42
Self-citationGarris, P. A., Ensman, R. E., Poehlman, J., Alexander, A., Langley, P. E., Sandberg, S. G., Greco, P. G., Wightman, R. M., & Rebec, G. V. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.04.043 · Cited by 51
Neural cognitive signals during spontaneous movements in the macaque
Tremblay, S., Testard, C., DiTullio, R. W., Inchauspé, J., & Petrides, M. (2022) · Nature Neuroscience · doi:10.1038/s41593-022-01220-4 · Cited by 44
Use of cortical neuronal networks for in vitro material biocompatibility testing
Charkhkar, H., Frewin, C. L., Nezafati, M., Knaack, G. L., Peixoto, N., Saddow, S. E., & Pancrazio, J. J. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.002 · Cited by 42
“Tungsten has been commonly used in neuronal implants for brain-computer interface applications (Kralik et al., 2001; Nicolelis et al., 2003; Prasad et al., 2012).”
MethodHomayoun, H., & Moghaddam, B. (2006) · Biological Psychiatry · doi:10.1016/j.biopsych.2006.05.016 · Cited by 43
“These included parametric F statistics of multivariate analysis of variance (MANOVA), the J3 and pseudo F statistics, and the Davies-Bouldin (DB) validity index (Nicolelis et al 2003).”
BackgroundMethodWang, C., Brunton, E., Haghgooie, S., Cassells, K., Lowery, A., & Rajan, R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046010 · Cited by 39
Zhang, H., Lin, S.-C., & Nicolelis, M. A. L. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00267.2011 · Cited by 41
“The multielectrode assembly or array (MEA) was constructed similarly to earlier studies (Lin and Nicolelis 2008; Nicolelis et al. 2003).”
ResultSelf-citationTechnology and Signal Processing for Brain-Machine Interfaces
Sanchez, J. C., Príncipe, J. C., Nishida, T., Bashirullah, R., Harris, J. G., & Fortes, J. A. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408440 · Cited by 43
Inter-laminar microcircuits across neocortex: repair and augmentation
Opriș, I. C. (2013) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2013.00080 · Cited by 41
“Repair and brain augmentation approaches, such as brain-machine interfaces, neural stimulation and other neural prostheses, have experienced a rapid development during the last decade (Nicolelis et al., 2003; Lebedev and Nicolelis, 2006).”
BackgroundQuantifying Time-Varying Multiunit Neural Activity Using Entropy-Based Measures
Choi, Y.-S., Koenig, M. A., Jia, X., & Thakor, N. V. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2049266 · Cited by 41
“The use of SUA is hampered, especially when SUA is hard to separate or when if it turns out to be difficult to record from the same neuron for sufficiently long periods [6], [7].”
BackgroundReshaping the human condition: exploring human enhancement
Zonneveld, L., Dijstelbloem, H., & Dj, R. (2008) · Data Archiving and Networked Services (DANS) · Cited by 48
Database Analysis of Simulated and Recorded Electrophysiological Datasets with PANDORA’s Toolbox
Günay, C., Edgerton, J. R., Li, S., Sangrey, T., Prinz, A. A., & Jaeger, D. (2009) · Neuroinformatics · doi:10.1007/s12021-009-9048-z · Cited by 44
“2008a, b), or to analyze the continuous streams from dozens of electrodes (Nicolelis et al. 2003).”
Synthesis, Properties, and Biological Application of Perfect Crystal Gold Nanowires: A Review
Kang, M., Lee, H., Kang, T., & Kim, B. (2015) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2015.01.007 · Cited by 39
Kao, T., Shumsky, J. S., Knudsen, E. B., Murray, M., & Moxon, K. A. (2011) · Journal of Neurophysiology · doi:10.1152/jn.01017.2010 · Cited by 43
Semi-Implantable Bioelectronics
Fang, J., Huang, S., Liu, F., He, G., Li, X., Huang, X., Chen, H., & Xie, X. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00818-4 · Cited by 43
Multifunctional bioelectronics for brain–body circuits
Sahasrabudhe, A., Cea, C., & Anikeeva, P. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00289-3 · Cited by 38
“Despite their mechanical mismatch with brain tissue and the corresponding propensity for glial scarring, rigid substrates such as metal 26 , glass 27 and silicon 13,28 remain extensively employed in brain interfaces owing to their mechanical strength, fluid barrier properties and compatibility with…”
Conducting Polymer Microcups for Organic Bioelectronics and Drug Delivery Applications
Antensteiner, M., Khorrami, M., Fallahianbijan, F., Borhan, A., & Abidian, M. R. (2017) · Advanced Materials · doi:10.1002/adma.201702576 · Cited by 37
Matrigel coatings forParylene sheath neural probes
Lee, C. D., Hara, S. A., Yu, L., Kuo, J. T. W., Kim, B. J., Hoang, T., Pikov, V., & Meng, E. (2016) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33390 · Cited by 35
Stapleton, J. R., Lavine, M., Nicolelis, M. A. L., & Simon, S. A. (2007) · Frontiers in Neuroscience · doi:10.3389/neuro.01.1.1.012.2007 · Cited by 36
Self-citationRecent advances in electronic devices for monitoring and modulation of brain
Kwon, Y. W., Jun, Y. S., Park, Y., Jang, J., & Park, J. (2021) · Nano Research · doi:10.1007/s12274-021-3476-y · Cited by 36
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 36
Assessment of gliosis around moveable implants in the brain
Stice, P., & Muthuswamy, J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046004 · Cited by 43
Metadata
- Authors
- Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P.
- Affiliations
- Duke University (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-09-05
- Volume
- 100
- Issue
- 19
- Pages
- 11041-11046
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC196923
- OpenAlex
- W2095504054
- Cited by
- 740
- References
- 28
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 13 · 2023: 12 · 2022: 28 · 2021: 24 · 2020: 28 · 2019: 31 · 2018: 26 · 2017: 31 · 2016: 26 · 2015: 39 · 2014: 49 · 2013: 45 · 2012: 36
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Hispana (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- single-unit recording, macaque, rhesus monkeys, microwire arrays, multi-electrode recording, cortical neurons, neuroprosthetics, sensorimotor integration
- MeSH terms
- Action Potentials, Animals, Cerebral Cortex, Electrodes, Female, Macaca mulatta, Male
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.