The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Stimulation of neurite outgrowth using an electrically conducting polymer
Open accessAbstract
Damage to peripheral nerves often cannot be repaired by the juxtaposition of the severed nerve ends. Surgeons have typically used autologous nerve grafts, which have several drawbacks including the need for multiple surgical procedures and loss of function at the donor site. As an alternative, the use of nerve guidance channels to bridge the gap between severed nerve ends is being explored. In this paper, the electrically conductive polymer—oxidized polypyrrole (PP)—has been evaluated for use as a substrate to enhance nerve cell interactions in culture as a first step toward potentially using such polymers to stimulate in vivo nerve regeneration. Image analysis demonstrates that PC-12 cells and primary chicken sciatic nerve explants attached and extended neurites equally well on both PP films and tissue culture polystyrene in the absence of electrical stimulation. In contrast, PC-12 cells interacted poorly with indium tin oxide (ITO), poly( l -lactic acid) (PLA), and poly(lactic acid-co-glycolic acid) surfaces. However, PC-12 cells cultured on PP films and subjected to an electrical stimulus through the film showed a significant increase in neurite lengths compared with ones that were not subjected to electrical stimulation through the film and tissue culture polystyrene controls. The median neurite length for PC-12 cells grown on PP and subjected to an electrical stimulus was 18.14 μm ( n = 5643) compared with 9.5 μm ( n = 4440) for controls. Furthermore, animal implantation studies reveal that PP invokes little adverse tissue response compared with poly(lactic acid-co-glycolic acid).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Greene, L. A., & Tischler, A. S. (1976) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.73.7.2424 · Cited by 5,553
Electrochemistry of conducting polypyrrole films
Diaz, A. F., Castillo, J. I., Logan, J. A., & Lee, W.-Y. (1981) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(81)80008-3 · Cited by 924
Introduction to the Theory of Nonparametric Statistics.
Haigh, J., Randles, R. H., & Wolfe, D. A. (1980) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982149 · Cited by 736
Operative Nerve Repair and Reconstruction
Gelberman, R. H. (1992) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199207000-00038 · Cited by 630
Electrically conducting polymers can noninvasively control the shape and growth of mammalian cells.
Wong, J. Y., Langer, R., & Ingber, D. E. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.8.3201 · Cited by 519
Self-citationOrientation of neurite growth by extracellular electric fields
Patel, N., & Poo, M. (1982) · The Journal of Neuroscience · doi:10.1523/jneurosci.02-04-00483.1982 · Cited by 510
Archibald, S. J., Krarup, C., Shefner, J., Li, S., & Madison, R. D. (1991) · Journal of Comparative Neurology · doi:10.1002/cne.903060410 · Cited by 374
Electrically charged polymeric substrates enhance nerve fibre outgrowth In vitro
Valentini, R. F., Vargo, T. G., Gardella, J. A., & Aebischer, P. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90069-z · Cited by 212
The Biomedical Engineering Handbook: Second Edition.
W. von Maltzahn, W. (1999) · Electrical Engineering Handbook · doi:10.1201/9781420049510.sec8 · Cited by 170
Piezoelectric guidance channels enhance regeneration in the mouse sciatic nerve after axotomy
Aebischer, P., Valentini, R. F., Dario, P., Domenici, C., & Galletti, P. M. (1987) · Brain Research · doi:10.1016/0006-8993(87)91570-8 · Cited by 167
Cited by
Items 101–114 of 114
Organic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Richardson, R. T., Thompson, B., Moulton, S., Newbold, C., Lum, M. G., Cameron, A., Wallace, G., Kapsa, R., Clark, G., & O’Leary, S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.008 · Cited by 251
Ciofani, G., Danti, S., D’Alessandro, D., Ricotti, L., Moscato, S., Bertoni, G., Falqui, A., Berrettini, S., Petrini, M., Mattoli, V., et al. (2010) · ACS Nano · doi:10.1021/nn101985a · Cited by 252
Biomimetic conducting polymer-based tissue scaffolds
Hardy, J. G., Lee, J. Y., & Schmidt, C. E. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.03.011 · Cited by 252
Self-citationSurface strategies for control of neuronal cell adhesion: A review
Roach, P., Parker, T., Gadegaard, N., & Alexander, M. R. (2010) · Surface Science Reports · doi:10.1016/j.surfrep.2010.07.001 · Cited by 180
Sasaki, M., Karikkineth, B. C., Nagamine, K., Kaji, H., Torimitsu, K., & Nishizawa, M. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400209 · Cited by 169
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(02)00427-2 · Cited by 160
Huang, Y., Wu, H., Tai, N., & Wang, T. (2012) · Small · doi:10.1002/smll.201200715 · Cited by 149
Ultrasound-induced wireless energy harvesting: from materials strategies to functional applications
Jiang, L., Yang, Y., Chen, Y., & Zhou, Q. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105131 · Cited by 131
Stretchable Polymeric Multielectrode Array for Conformal Neural Interfacing
Guo, L., Ma, M., Zhang, N., Langer, R., & Anderson, D. G. (2014) · Advanced Materials · doi:10.1002/adma.201304140 · Cited by 128
Self-citationConducting polymers with immobilised fibrillar collagen for enhanced neural interfacing
Liu, X., Yue, Z., Higgins, M. J., & Wallace, G. G. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.047 · Cited by 124
“The length of primary neurites was measured from the junction of the cell body to the distal tip [20].”
BackgroundMethodSun, B., Zhou, Z., Li, D., Wu, T., Zheng, H., Liu, J., Wang, G., Yu, Y., & Mo, X. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.09.021 · Cited by 100
Tissue/Organ Adaptable Bioelectronic Silk‐Based Implants
Zhu, Z., Yan, Z., Ni, S., Yang, H., Xie, Y., Wang, X., Zou, D., Tao, C., Jiang, W., Jiang, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202405892 · Cited by 27
Combining Topographical and Genetic Cues to Promote Neuronal Fate Specification in Stem Cells
Purcell, E. K., Naim, Y., Yang, A., Leach, M. K., Velkey, J. M., Duncan, R. K., & Corey, J. M. (2012) · Biomacromolecules · doi:10.1021/bm301220k · Cited by 26
Metadata
- Authors
- Schmidt, C. E., Shastri, V. R., Vacanti, J. P., & Langer, R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1997-08-19
- Volume
- 94
- Issue
- 17
- Pages
- 8948-8953
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2076735034
- Cited by
- 1,071
- References
- 23
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.