A Software Suite for the Generation and Comparison of Peptide Arrays from Sets of Data Collected by Liquid Chromatography-Mass Spectrometry
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
There is an increasing interest in the quantitative proteomic measurement of the protein contents of substantially similar biological samples, e.g. for the analysis of cellular response to perturbations over time or for the discovery of protein biomarkers from clinical samples. Technical limitations of current proteomic platforms such as limited reproducibility and low throughput make this a challenging task. A new LC-MS-based platform is able to generate complex peptide patterns from the analysis of proteolyzed protein samples at high throughput and represents a promising approach for quantitative proteomics. A crucial component of the LC-MS approach is the accurate evaluation of the abundance of detected peptides over many samples and the identification of peptide features that can stratify samples with respect to their genetic, physiological, or environmental origins. We present here a new software suite, SpecArray, that generates a peptide versus sample array from a set of LC-MS data. A peptide array stores the relative abundance of thousands of peptide features in many samples and is in a format identical to that of a gene expression microarray. A peptide array can be subjected to an unsupervised clustering analysis to stratify samples or to a discriminant analysis to identify discriminatory peptide features. We applied the SpecArray to analyze two sets of LC-MS data: one was from four repeat LC-MS analyses of the same glycopeptide sample, and another was from LC-MS analysis of serum samples of five male and five female mice. We demonstrate through these two study cases that the SpecArray software suite can serve as an effective software platform in the LC-MS approach for quantitative proteomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372
Cluster analysis and display of genome-wide expression patterns
Eisen, M. B., Spellman, P. T., Brown, P. O., & Botstein, D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.25.14863 · Cited by 16,184 · cited 5×
“The Cluster program (rana.lbl.gov/EisenSoftware.htm) (29) was used for unsupervised hierarchical clustering analysis of peptide arrays.”
BackgroundMethodInfluentialPerkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 1×
“The obtained peptide samples are then separated by a multidimensional LC system and analyzed by MS/ MS. Peptides are ionized either by ESI ( 14 ) or by MALDI (15), and peptide ions are selected, usually in the order of decreasing signal intensity, for fragmentation by CID (16, 17).”
MethodMass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Self-citationEng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 1×
“Peptides are identified by using an automated search engine, such as SEQUEST (18) or Mascot (19), to match their fragment ions against a designated protein database.”
MethodLaser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637 · cited 1×
“The obtained peptide samples are then separated by a multidimensional LC system and analyzed by MS/ MS. Peptides are ionized either by ESI (14) or by MALDI (15), and peptide ions are selected, usually in the order of decreasing signal intensity, for fragmentation by CID (16, 17).”
MethodOng, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574 · cited 1×
“If combined with stable isotope labeling, such methods can also accurately quantify proteins (7-13).”
BackgroundA Statistical Model for Identifying Proteins by Tandem Mass Spectrometry
Nesvizhskii, A. I., Keller, A., Kolker, E., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac0341261 · Cited by 4,809 · cited 1×
“The identification and quantification of proteins is then achieved by combining the information obtained from the peptides that associate with the particular protein (20, 21).”
Self-citationLarge-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752 · cited 1×
“LC-MS LC-MS/MS-based methods are currently most efficient for the identification of a large number of proteins and have been widely applied in biological and biomedical research (5–7).”
Method
Cited by
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
“Orbitrap, QqTOF, and QLT-FT-ICR) for targeted, quantitative measurements (61-65), QqOrbi PRM achieved, on average, 2-3-fold better run-to-run measurement precision.”
MethodLess label, more free: Approaches in label‐free quantitative mass spectrometry
Neilson, K. A., Ali, N. A., Muralidharan, S., Mirzaei, M., Mariani, M., Assadourian, G., Lee, A., van Sluyter, S. C., & Haynes, P. A. (2011) · PROTEOMICS · doi:10.1002/pmic.201000553 · Cited by 704
OpenMS – An open-source software framework for mass spectrometry
Sturm, M., Bertsch, A., Gröpl, C., Hildebrandt, A., Hussong, R., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., Zerck, A., Reinert, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-163 · Cited by 644
Analysis and validation of proteomic data generated by tandem mass spectrometry
Nesvizhskii, A. I., Vitek, O., & Aebersold, R. (2007) · Nature Methods · doi:10.1038/nmeth1088 · Cited by 629
Self-citationData processing for mass spectrometry-based metabolomics
Katajamaa, M., & Orešič, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.021 · Cited by 616
Li, G., Vissers, J. P. C., Silva, J. C., Golick, D., Gorenstein, M. V., & Geromanos, S. J. (2009) · PROTEOMICS · doi:10.1002/pmic.200800564 · Cited by 557
Human body fluid proteome analysis
Hu, S., Loo, J. A., & Wong, D. T. (2006) · PROTEOMICS · doi:10.1002/pmic.200600284 · Cited by 533
Mueller, L. N., Brusniak, M.-Y., Mani, D. R., & Aebersold, R. (2008) · Journal of Proteome Research · doi:10.1021/pr700758r · Cited by 449
Self-citationProteomics: a pragmatic perspective
Mallick, P., & Kuster, B. (2010) · Nature Biotechnology · doi:10.1038/nbt.1658 · Cited by 430
Uppal, K., Soltow, Q. A., Strobel, F. H., Pittard, W. S., Gernert, K. M., Yu, T., & Jones, D. P. (2013) · BMC Bioinformatics · doi:10.1186/1471-2105-14-15 · Cited by 372
Significance Analysis of Spectral Count Data in Label-free Shotgun Proteomics
Choi, H., Fermin, D., & Nesvizhskii, A. I. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800203-mcp200 · Cited by 364
MassChroQ: A versatile tool for mass spectrometry quantification
Valot, B., Langella, O., Nano, E., & Zivy, M. (2011) · PROTEOMICS · doi:10.1002/pmic.201100120 · Cited by 331
SuperHirn – a novel tool for high resolution LC‐MS‐based peptide/protein profiling
Mueller, L. N., Rinner, O., Schmidt, A., Letarte, S., Bodenmiller, B., Brusniak, M., Vitek, O., Aebersold, R., & Müller, M. (2007) · PROTEOMICS · doi:10.1002/pmic.200700057 · Cited by 308
Self-citationSolid-phase extraction of N-linked glycopeptides
Tian, Y., Zhou, Y., Elliott, S., Aebersold, R., & Zhang, H. (2007) · Nature Protocols · doi:10.1038/nprot.2007.42 · Cited by 286
Self-citationTOPP—the OpenMS proteomics pipeline
Kohlbacher, O., Reinert, K., Gröpl, C., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., & Sturm, M. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btl299 · Cited by 281
Bellew, M., Coram, M., Fitzgibbon, M., Igra, M., Randolph, T., Wang, P., May, D., Eng, J., Fang, R., Lin, C., et al. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btl276 · Cited by 265
Statistical Design of Quantitative Mass Spectrometry-Based Proteomic Experiments
Oberg, A. L., & Vitek, O. (2009) · Journal of Proteome Research · doi:10.1021/pr8010099 · Cited by 256
Analytical and statistical approaches to metabolomics research
Issaq, H. J., Van, Q. N., Waybright, T. J., Muschik, G. M., & Veenstra, T. D. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900152 · Cited by 227
Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics
Xie, F., Liu, T., Qian, W.-J., Petyuk, V. A., & Smith, R. D. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r110.199703 · Cited by 215
Guide for protein fold change and p -value calculation for non-experts in proteomics
Aguilan, J. T., Kulej, K., & Sidoli, S. (2020) · Molecular Omics · doi:10.1039/d0mo00087f · Cited by 204
Ono, M., Shitashige, M., Honda, K., Isobe, T., Kuwabara, H., Matsuzuki, H., Hirohashi, S., & Yamada, T. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500039-mcp200 · Cited by 194
“We also eliminated MS/MS and tried to detect all the peptides present in a given sample by high speed survey scanning as frequently as every 1 s. MS/MS scanning is a time-consuming procedure and often overlooks minor protein fragments (10).”
BackgroundMethodA Blood-Based Proteomic Classifier for the Molecular Characterization of Pulmonary Nodules
Li, X.-J., Hayward, C., Fong, P.-Y., Dominguez, M., Hunsucker, S. W., Lee, L. W., McLean, M., Law, S., Butler, H., Schirm, M., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007013 · Cited by 192
Self-citationComparative LC‐MS: A landscape of peaks and valleys
America, A. H. P., & Cordewener, J. H. G. (2008) · PROTEOMICS · doi:10.1002/pmic.200700694 · Cited by 191
Knowledge discovery in metabolomics: An overview of MS data handling
Boccard, J., Veuthey, J., & Rudaz, S. (2010) · Journal of Separation Science · doi:10.1002/jssc.200900609 · Cited by 189
Critical assessment of alignment procedures for LC-MS proteomics and metabolomics measurements
Lange, E., Tautenhahn, R., Neumann, S., & Gröpl, C. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-375 · Cited by 187
“The alignments using SpecArray were canceled after 24 hours with an estimated remaining runtime of more than two weeks.”
MethodInfluentialEffect of Dynamic Exclusion Duration on Spectral Count Based Quantitative Proteomics
Zhang, Y., Wen, Z., Washburn, M. P., & Florens, L. (2009) · Analytical Chemistry · doi:10.1021/ac9004887 · Cited by 184
Algorithms and tools for the preprocessing of LC–MS metabolomics data
Castillo, S., Gopalacharyulu, P., Yetukuri, L., & Orešič, M. (2011) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2011.03.010 · Cited by 175
Sun, B., Ranish, J. A., Utleg, A. G., White, J. T., Yan, X., Lin, B., & Hood, L. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t600046-mcp200 · Cited by 165
“3 shows the Pep3D result (38, 39) of the identified peptides with peptide probability value greater than 0.”
Rinner, O., Mueller, L. N., Hubálek, M., Müller, M., Gstaiger, M., & Aebersold, R. (2007) · Nature Biotechnology · doi:10.1038/nbt1289 · Cited by 162
“An alternative approach is to use label-free quantification of peptide signals (features), which are identified in different samples based on their MS1 ion current”
MethodSelf-citationRodríguez-Suárez, E., Gonzalez, E., Hughes, C., Conde-Vancells, J., Rudella, A., Royo, F., Palomo, L., Elortza, F., Lu, S. C., Mato, J. M., et al. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.04.008 · Cited by 76
Metadata
- Authors
- Li, X.-J., Yi, E. C., Kemp, C. J., Zhang, H., & Aebersold, R.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2005-09
- Volume
- 4
- Issue
- 9
- Pages
- 1328-1340
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2135817903
- Cited by
- 185
- References
- 40
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.