A Software Suite for the Generation and Comparison of Peptide Arrays from Sets of Data Collected by Liquid Chromatography-Mass Spectrometry
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
There is an increasing interest in the quantitative proteomic measurement of the protein contents of substantially similar biological samples, e.g. for the analysis of cellular response to perturbations over time or for the discovery of protein biomarkers from clinical samples. Technical limitations of current proteomic platforms such as limited reproducibility and low throughput make this a challenging task. A new LC-MS-based platform is able to generate complex peptide patterns from the analysis of proteolyzed protein samples at high throughput and represents a promising approach for quantitative proteomics. A crucial component of the LC-MS approach is the accurate evaluation of the abundance of detected peptides over many samples and the identification of peptide features that can stratify samples with respect to their genetic, physiological, or environmental origins. We present here a new software suite, SpecArray, that generates a peptide versus sample array from a set of LC-MS data. A peptide array stores the relative abundance of thousands of peptide features in many samples and is in a format identical to that of a gene expression microarray. A peptide array can be subjected to an unsupervised clustering analysis to stratify samples or to a discriminant analysis to identify discriminatory peptide features. We applied the SpecArray to analyze two sets of LC-MS data: one was from four repeat LC-MS analyses of the same glycopeptide sample, and another was from LC-MS analysis of serum samples of five male and five female mice. We demonstrate through these two study cases that the SpecArray software suite can serve as an effective software platform in the LC-MS approach for quantitative proteomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372
Cluster analysis and display of genome-wide expression patterns
Eisen, M. B., Spellman, P. T., Brown, P. O., & Botstein, D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.25.14863 · Cited by 16,184 · cited 5×
“The Cluster program (rana.lbl.gov/EisenSoftware.htm) (29) was used for unsupervised hierarchical clustering analysis of peptide arrays.”
BackgroundMethodInfluentialPerkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 1×
“The obtained peptide samples are then separated by a multidimensional LC system and analyzed by MS/ MS. Peptides are ionized either by ESI ( 14 ) or by MALDI (15), and peptide ions are selected, usually in the order of decreasing signal intensity, for fragmentation by CID (16, 17).”
MethodMass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Self-citationEng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 1×
“Peptides are identified by using an automated search engine, such as SEQUEST (18) or Mascot (19), to match their fragment ions against a designated protein database.”
MethodLaser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637 · cited 1×
“The obtained peptide samples are then separated by a multidimensional LC system and analyzed by MS/ MS. Peptides are ionized either by ESI (14) or by MALDI (15), and peptide ions are selected, usually in the order of decreasing signal intensity, for fragmentation by CID (16, 17).”
MethodOng, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574 · cited 1×
“If combined with stable isotope labeling, such methods can also accurately quantify proteins (7-13).”
BackgroundA Statistical Model for Identifying Proteins by Tandem Mass Spectrometry
Nesvizhskii, A. I., Keller, A., Kolker, E., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac0341261 · Cited by 4,809 · cited 1×
“The identification and quantification of proteins is then achieved by combining the information obtained from the peptides that associate with the particular protein (20, 21).”
Self-citationLarge-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752 · cited 1×
“LC-MS LC-MS/MS-based methods are currently most efficient for the identification of a large number of proteins and have been widely applied in biological and biomedical research (5–7).”
MethodQuantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683 · cited 3×
“(7) Peptide features of all samples are combined into a peptide “super” list.”
BackgroundRoss, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401 · cited 1×
“If combined with stable isotope labeling, such methods can also accurately quantify proteins (7–13).”
BackgroundTranslation-Invariant De-Noising
Coifman, R. R., & Donoho, D. L. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_9 · Cited by 1,914 · cited 2×
“The software tool mzXML2dat applies advanced signal processing technologies, such as the translation-invariant wavelet transformation (32, 33), to extract peptide signals from raw LC-MS data as described under “Experimental Procedures.””
MethodZhang, H., Li, X.-J., Martin, D. B., & Aebersold, R. (2003) · Nature Biotechnology · doi:10.1038/nbt827 · Cited by 1,389 · cited 3×
“Formerly N -linked glycosylated peptides were isolated from 50 (cid:1) l of each sample using the N -linked glycopeptide capture procedure as described previously (23, 30).”
BackgroundMethodSelf-citationMass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238 · cited 1×
“The obtained peptide samples are then separated by a multidimensional LC system and analyzed by MS/ MS. Peptides are ionized either by ESI (14) or by MALDI (15), and peptide ions are selected, usually in the order of decreasing signal intensity, for fragmentation by CID (16, 17).”
MethodSelf-citationProtein sequencing by tandem mass spectrometry.
Hunt, D. F., Yates, J. R., Shabanowitz, J., Winston, S., & Hauer, C. R. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6233 · Cited by 1,180 · cited 3×
“Even after extensive peptide fractionation, a significant fraction of the peptides present in a sample is not selected by the mass spectrometer for CID (25).”
MethodAccurate quantitation of protein expression and site-specific phosphorylation
Oda, Y., Huang, K., Cross, F. R., Cowburn, D., & Chait, B. T. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.12.6591 · Cited by 1,006 · cited 1×
“If combined with stable isotope labeling, such methods can also accurately quantify proteins (7-13).”
BackgroundTyers, M., & Mann, M. (2003) · Nature · doi:10.1038/nature01510 · Cited by 1,006 · cited 1×
“The identification and quantification of the protein contents of biological samples plays a crucial role in biological and biomedical research (1–4).”
BackgroundHanash, S. (2003) · Nature · doi:10.1038/nature01514 · Cited by 900
Han, D. K., Eng, J., Zhou, H., & Aebersold, R. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-946 · Cited by 876 · cited 1×
“Peptides are quantified by using a quantification software tool, such as XPRESS (8) or ASAPRatio (20), that uses the relative MS signal intensities of the different isotopic forms to calculate the relative abundance of each identified peptide.”
MethodSelf-citationToward a Human Blood Serum Proteome
Adkins, J. N., Varnum, S. M., Auberry, K. J., Moore, R. J., Angell, N. H., Smith, R. D., Springer, D. L., & Pounds, J. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200066-mcp200 · Cited by 793 · cited 1×
“Typical examples include the discovery of protein biomarkers from clinical samples (3, 22, 23) and the measurement of the response of cells and tissues to perturbations.”
BackgroundA common open representation of mass spectrometry data and its application to proteomics research
Pedrioli, P. G. A., Eng, J. K., Hubley, R., Vogelzang, M., Deutsch, E. W., Raught, B., Pratt, B., Nilsson, E., Angeletti, R. H., Apweiler, R., et al. (2004) · Nature Biotechnology · doi:10.1038/nbt1031 · Cited by 780 · cited 3×
“Raw MS data were converted into the mzXML common file format using the MassWolf file converter (31).”
MethodSelf-citationProteolytic 18O Labeling for Comparative Proteomics: Model Studies with Two Serotypes of Adenovirus
Yao, X., Freas, A., Ramirez, J., Demirev, P. A., & Fenselau, C. (2001) · Analytical Chemistry · doi:10.1021/ac001404c · Cited by 759
A proteomics strategy to elucidate functional protein-protein interactions applied to EGF signaling
Blagoev, B., Kratchmarova, I., Ong, S.-E., Nielsen, M., Foster, L. J., & Mann, M. (2003) · Nature Biotechnology · doi:10.1038/nbt790 · Cited by 689
Temporal analysis of phosphotyrosine-dependent signaling networks by quantitative proteomics
Blagoev, B., Ong, S.-E., Kratchmarova, I., & Mann, M. (2004) · Nature Biotechnology · doi:10.1038/nbt1005 · Cited by 681 · cited 1×
“For the study of cellular response to perturbations, temporal and dose-dependent changes are usually particularly informative for the identification of patterns of proteins that are specifically affected by the treatment (24).”
BackgroundWang, W., Zhou, H., Lin, H., Roy, S., Shaler, T. A., Hill, L. R., Norton, S., Kumar, P., Anderle, M., & Becker, C. H. (2003) · Analytical Chemistry · doi:10.1021/ac026468x · Cited by 653 · cited 2×
“As an alternative to LC-MS/MS-based methods, peptide mapping by LC-MS has been gaining momentum as a method for quantitative proteomics (23, 26, 27).”
BackgroundMethod(1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7 · Cited by 569
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · cited 1×
“Assuming the most intense signal is produced by the monoisotopic mass ( M ) of a peptide, the software then calculates the expected peptide isotopic distribution (34, 35) and assesses how well the distribution fits neighboring MS signals.”
BackgroundWashburn, M. P., Ulaszek, R., Deciu, C., Schieltz, D. M., & Yates, J. R. (2002) · Analytical Chemistry · doi:10.1021/ac015704l · Cited by 390
Bondarenko, P. V., Chelius, D., & Shaler, T. A. (2002) · Analytical Chemistry · doi:10.1021/ac0256991 · Cited by 387 · cited 1×
“Therefore one may evaluate the relative abundance of a peptide in different, related samples by analyzing the samples under identical LC-MS conditions and by comparing MS signal intensity of the same peptide in different LC-MS runs (26–28).”
BackgroundYin, H., Killeen, K., Brennen, R., Sobek, D., Werlich, M., & van de Goor, T. (2005) · Analytical Chemistry · doi:10.1021/ac049068d · Cited by 362 · cited 1×
“New developments such as chip-based LC columns and improved nanoflow chromatography systems also significantly increase the resolution power and the reproducibility of peptide separation (38).”
BackgroundSyka, J. E. P., Marto, J. A., Bai, D. L., Horning, S., Senko, M. W., Schwartz, J. C., Ueberheide, B., Garcia, B., Busby, S., Muratore, T., et al. (2004) · Journal of Proteome Research · doi:10.1021/pr0499794 · Cited by 348 · cited 1×
“New MS instruments such as the linear ion trap Fourier transform (LTQ-FT) mass spectrometer offer much improved accuracy and sensitivity in measuring peptide ions ( 39 ).”
BackgroundLi, X.-J., Zhang, H., Ranish, J. A., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac034633i · Cited by 342 · cited 6×
“The software then collects all abundance ratios of common peptide features in each sample and applies a methodology developed for the ASAPRatio program (20) to calculate a sample-dependent normalization factor for the sample.”
BackgroundMethodInfluentialSelf-citationRadulovic, D., Jelveh, S., Ryu, S., Hamilton, T. G., Foss, E., Mao, Y., & Emili, A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400061-mcp200 · Cited by 207 · cited 1×
“As an alternative to LC-MS/MS-based methods, peptide mapping by LC-MS has been gaining momentum as a method for quantitative proteomics (23, 26, 27).”
MethodZhang, H., Yi, E. C., Li, X.-J., Mallick, P., Kelly-Spratt, K. S., Masselon, C. D., Camp, D. G., Smith, R. D., Kemp, C. J., & Aebersold, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400090-mcp200 · Cited by 207
Self-citationBiomedical informatics for proteomics
Boguski, M. S., & McIntosh, M. W. (2003) · Nature · doi:10.1038/nature01515 · Cited by 178 · cited 2×
“The identification and quantification of the protein contents of biological samples plays a crucial role in biological and biomedical research (1–4).”
BackgroundLi, X., Pedrioli, P. G. A., Eng, J. K., Martin, D. B., Yi, E. C., Lee, H., & Aebersold, R. H. (2004) · Analytical Chemistry · doi:10.1021/ac035375s · Cited by 91 · cited 7×
“1) The Pep3D module visualizes LC-MS data in graphic images to ensure data quality (25); 2) the mzXML2dat module extracts high quality MS signals from raw noisy MS signals; 3) the PepList module applies pattern matching to extract peptide features from MS signals; 4) the PepMatch module aligns…”
BackgroundMethodInfluentialSelf-citationLi, Y., & Cole, R. B. (2003) · Analytical Chemistry · doi:10.1021/ac0301402 · Cited by 60 · cited 1×
“The discrepancy in the peptide charge distribution between the two experiments may arise from differences in LC and/or MS settings ( 36 ).”
BackgroundTeshima, G. M., Porter, J., Yim, K., Ling, V. W. T., & Guzzetta, A. W. (1991) · Biochemistry · doi:10.1021/bi00230a016 · Cited by 56 · cited 1×
“It is not clear whether the two features were chemically related, e.g. by deamidation ( 37 ).”
BackgroundWehofsky, M., Hoffmann, R., Hubert, M., & Spengler, B. (2001) · European Journal of Mass Spectrometry · doi:10.1255/ejms.387 · Cited by 51 · cited 1×
“Assuming the most intense signal is produced by the mono-isotopic mass ( M ) of a peptide, the software then calculates the expected peptide isotopic distribution (34, 35) and assesses how well the distribution fits neighboring MS signals.”
Background
Cited by
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
“Orbitrap, QqTOF, and QLT-FT-ICR) for targeted, quantitative measurements (61-65), QqOrbi PRM achieved, on average, 2-3-fold better run-to-run measurement precision.”
MethodLess label, more free: Approaches in label‐free quantitative mass spectrometry
Neilson, K. A., Ali, N. A., Muralidharan, S., Mirzaei, M., Mariani, M., Assadourian, G., Lee, A., van Sluyter, S. C., & Haynes, P. A. (2011) · PROTEOMICS · doi:10.1002/pmic.201000553 · Cited by 704
OpenMS – An open-source software framework for mass spectrometry
Sturm, M., Bertsch, A., Gröpl, C., Hildebrandt, A., Hussong, R., Lange, E., Pfeifer, N., Schulz-Trieglaff, O., Zerck, A., Reinert, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-163 · Cited by 644
Analysis and validation of proteomic data generated by tandem mass spectrometry
Nesvizhskii, A. I., Vitek, O., & Aebersold, R. (2007) · Nature Methods · doi:10.1038/nmeth1088 · Cited by 629
Self-citationData processing for mass spectrometry-based metabolomics
Katajamaa, M., & Orešič, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.021 · Cited by 616
Metadata
- Authors
- Li, X.-J., Yi, E. C., Kemp, C. J., Zhang, H., & Aebersold, R.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2005-09
- Volume
- 4
- Issue
- 9
- Pages
- 1328-1340
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2135817903
- Cited by
- 185
- References
- 40
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.