Abstract
Mass measurement is the main outcome of mass spectrometry-based proteomics yet the potential of recent advances in accurate mass measurements remains largely unexploited. There is not even a clear definition of mass accuracy in the proteomics literature, and we identify at least three uses of this term: anecdotal mass accuracy, statistical mass accuracy, and the maximum mass deviation (MMD) allowed in a database search. We suggest using the second of these terms as the generic one. To make the best use of the mass precision offered by modern instruments we propose a series of simple steps involving recalibration of the data on "internal standards" contained in every proteomics data set. Each data set should be accompanied by a plot of mass errors from which the appropriate MMD can be chosen. More advanced uses of high mass accuracy include an MMD that depends on the signal abundance of each peptide. Adapting search engines to high mass accuracy in the MS/MS data is also a high priority. Proper use of high mass accuracy data can make MS-based proteomics one of the most "digital" and accurate post-genomics disciplines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“We emphasize that MS-based data from high-accuracy14,15 MS instruments combined with subsequent high-stringency protein inference analysis provide definitive best-practice confirmation of protein identification and abundance.”
From A high-stringency blueprint of the human proteome (2020) · cites this paper as [14]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830 · cited 1×
“Such a weighting has already been incorporated into at least one composite peptide identification score (14).”
BackgroundOlsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510 · cited 1×
“This could be based on repeat measurement over an LC peak (5); this also has the advantage that the mass taken from”
BackgroundSelf-citationProteomic characterization of the human centrosome by protein correlation profiling
Andersen, J. S., Wilkinson, C. J., Mayor, T., Mortensen, P., Nigg, E. A., & Mann, M. (2003) · Nature · doi:10.1038/nature02166 · Cited by 1,319 · cited 1×
“” We have extensively used this concept in the “protein correlation profiling” technique in which thousands of peptides are quantified across protein fractions to distinguish true members of organelles from co-migrating background proteins (11, 12).”
MethodSelf-citationTrypsin Cleaves Exclusively C-terminal to Arginine and Lysine Residues
Olsen, J. V., Ong, S.-E., & Mann, M. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t400003-mcp200 · Cited by 1,254
Self-citationAnalysis of the Plasmodium falciparum proteome by high-accuracy mass spectrometry
Lasonder, E., Ishihama, Y., Andersen, J. S., Vermunt, A. M. W., Pain, A., Sauerwein, R. W., Eling, W. M. C., Hall, N., Waters, A. P., Stunnenberg, H. G., et al. (2002) · Nature · doi:10.1038/nature01111 · Cited by 652 · cited 1×
“We have used this procedure for a number of years in the open source program MSQuant (1) and find that it often improves mass accuracy severalfold, especially for TOF instruments ( 2 ).”
MethodSelf-citationA Mammalian Organelle Map by Protein Correlation Profiling
Foster, L. J., de Hoog, C. L., Zhang, Y., Zhang, Y., Xie, X., Mootha, V. K., & Mann, M. (2006) · Cell · doi:10.1016/j.cell.2006.03.022 · Cited by 576 · cited 1×
“” We have extensively used this concept in the “protein correlation profiling” technique in which thousands of peptides are quantified across protein fractions to distinguish true members of organelles from co-migrating background proteins (11, 12).”
MethodSelf-citationAn accurate mass tag strategy for quantitative and high-throughput proteome measurements
Smith, R. D., Anderson, G. A., Lipton, M. S., Pasa-Tolic, L., Shen, Y., Conrads, T. P., Veenstra, T. D., & Udseth, H. R. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200205)2:5<513::aid-prot513>3.0.co;2-w · Cited by 432
Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
Makarov, A., Denisov, E., Lange, O., & Horning, S. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.03.006 · Cited by 431
A Novel Proteomic Screen for Peptide-Protein Interactions
Schulze, W. X., & Mann, M. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m309909200 · Cited by 298 · cited 1×
“We have used this procedure for a number of years in the open source program MSQuant ( 1 ) and find that it often improves mass accuracy severalfold, especially for TOF instruments (2).”
MethodSelf-citationOptimization and Use of Peptide Mass Measurement Accuracy in Shotgun Proteomics
Haas, W., Faherty, B. K., Gerber, S. A., Elias, J. E., Beausoleil, S. A., Bakalarski, C. E., Li, X., Villén, J., & Gygi, S. P. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500339-mcp200 · Cited by 261
Cited by
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Self-citationUniversal sample preparation method for proteome analysis
Wiśniewski, J. R., Zougman, A., Nagaraj, N., & Mann, M. (2009) · Nature Methods · doi:10.1038/nmeth.1322 · Cited by 8,352
Self-citationQuantitative mass spectrometry in proteomics: a critical review
Bantscheff, M., Schirle, M., Sweetman, G., Rick, J., & Kuster, B. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1486-6 · Cited by 1,669
A practical guide to the MaxQuant computational platform for SILAC-based quantitative proteomics
Cox, J., Matic, I., Hilger, M., Nagaraj, N., Selbach, M., Olsen, J. V., & Mann, M. (2009) · Nature Protocols · doi:10.1038/nprot.2009.36 · Cited by 766
“has become a very data-intensive science, especially since high-resolution Fourier transform mass spectrometers have become widesprea”
BackgroundSelf-citationDecoding signalling networks by mass spectrometry-based proteomics
Choudhary, C., & Mann, M. (2010) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2900 · Cited by 571
Self-citationGeromanos, S. J., Vissers, J. P. C., Silva, J. C., Dorschel, C. A., Li, G., Gorenstein, M. V., Bateman, R. H., & Langridge, J. I. (2009) · PROTEOMICS · doi:10.1002/pmic.200800562 · Cited by 497
“As the complexity of the data increases, more stringent criteria are needed to improve the accuracy and specificity of the search results [32].”
BackgroundPrecision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450
“Importantly, peptide mass accuracy should be determined individually for each peptide to avoid degrading a highaccuracy instrument into a low-accuracy instrument in the process of database searching (23, 25).”
Self-citationAccurate and Sensitive Peptide Identification with Mascot Percolator
Brosch, M., Yu, L., Hubbard, T., & Choudhary, J. (2009) · Journal of Proteome Research · doi:10.1021/pr800982s · Cited by 428
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Mass spectrometry imaging with high resolution in mass and space
Römpp, A., & Spengler, B. (2013) · Histochemistry and Cell Biology · doi:10.1007/s00418-013-1097-6 · Cited by 358
“The terms ‘mass deviation,’ ‘mass accuracy’ and ‘maximum mass deviation’ are used according to the definition by Zubarev and Mann (2007).”
MethodA HUPO test sample study reveals common problems in mass spectrometry–based proteomics
HUPO Test Sample Working Group, Bell, A. W., Deutsch, E. W., Au, C. E., Kearney, R. E., Beavis, R., Sechi, S., Nilsson, T., & Bergeron, J. J. M. (2009) · Nature Methods · doi:10.1038/nmeth.1333 · Cited by 351
Quantitation in Mass-Spectrometry-Based Proteomics
Schulze, W. X., & Usadel, B. (2010) · Annual Review of Plant Biology · doi:10.1146/annurev-arplant-042809-112132 · Cited by 344
Burkhart, J. M., Schumbrutzki, C., Wortelkamp, S., Sickmann, A., & Zahedi, R. P. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2011.11.016 · Cited by 297
“In particular improvements in technical instrumentation [13,14] and software algo-”
BackgroundGraumann, J., Hubner, N. C., Kim, J. B., Ko, K., Moser, M., Kumar, C., Cox, J., Schöler, H., & Mann, M. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700460-mcp200 · Cited by 275
“Maximum allowed mass deviation (26) was set initially to 5 ppm for monoisotopic precursor ions and 0.”
Self-citationMultiplexed and data‐independent tandem mass spectrometry for global proteome profiling
Chapman, J. D., Goodlett, D. R., & Masselon, C. D. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21400 · Cited by 259
MSQuant, an Open Source Platform for Mass Spectrometry-Based Quantitative Proteomics
Mortensen, P., Gouw, J. W., Olsen, J. V., Ong, S.-E., Rigbolt, K. T. G., Bunkenborg, J., Cox, J., Foster, L. J., Heck, A. J. R., Blagoev, B., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr900721e · Cited by 254
Self-citationRedox Proteomics: Chemical Principles, Methodological Approaches and Biological/Biomedical Promises
Bachi, A., Dalle-Donne, I., & Scaloni, A. (2013) · Chemical Reviews · doi:10.1021/cr300073p · Cited by 251
Accurate mass measurement: Terminology and treatment of data
Brenton, A. G., & Godfrey, A. R. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.06.006 · Cited by 224
“The term “mass deviation” has been proposed to the proteomics community for reporting a single mass measurement error [16].”
BackgroundJorrín-Novo, J. V., Maldonado, A. M., Echevarría-Zomeño, S., Valledor, L., Castillejo, M. A., Curto, M., Valero, J., Sghaier, B., Donoso, G., & Redondo, I. (2009) · Journal of Proteomics · doi:10.1016/j.jprot.2009.01.026 · Cited by 220
Establishing the Proteome of Normal Human Cerebrospinal Fluid
Schutzer, S. E., Liu, T., Natelson, B. H., Angel, T. E., Schepmoes, A. A., Purvine, S. O., Hixson, K. K., Lipton, M. S., Camp, D. G., Coyle, P. K., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010980 · Cited by 217
“05 part per million (ppm), and peptide identifications with mass error of greater than 3s were filtered out[23,25,26].”
MethodA high-stringency blueprint of the human proteome
Adhikari, S., Nice, E. C., Deutsch, E. W., Lane, L., Omenn, G. S., Pennington, S. R., Paik, Y.-K., Overall, C. M., Corrales, F. J., Cristea, I. M., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19045-9 · Cited by 210
Böcker, S., & Dührkop, K. (2016) · Journal of Cheminformatics · doi:10.1186/s13321-016-0116-8 · Cited by 208
“It has been frequently observed that relative mass deviations are roughly normally-distributed [14,33].”
BackgroundA Face in the Crowd: Recognizing Peptides Through Database Search
Eng, J. K., Searle, B. C., Clauser, K. R., & Tabb, D. L. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r111.009522 · Cited by 187
“Zubarev and Mann propose methods to take advantage of mass accuracy, including more intelligently assigning mass error based on individual signal quality and incorporating mass deviation in the database search scores (34).”
MethodComputational mass spectrometry for small molecules
Scheubert, K., Hufsky, F., & Böcker, S. (2013) · Journal of Cheminformatics · doi:10.1186/1758-2946-5-12 · Cited by 173
“This refers to the mass accuracy that we can expect in everyday use of the instrument, not to the “anecdotal mass accuracy” of a single measurement [53].”
BackgroundMittler, G., Butter, F., & Mann, M. (2009) · Genome Research · doi:10.1101/gr.081711.108 · Cited by 164
Self-citationComputing Fragmentation Trees from Tandem Mass Spectrometry Data
Rasche, F., Svatoš, A., Maddula, R. K., Böttcher, C., & Böcker, S. (2011) · Analytical Chemistry · doi:10.1021/ac101825k · Cited by 158
Wang, Y., Meriin, A. B., Zaarur, N., Romanova, N. V., Chernoff, Y. O., Costello, C. E., & Sherman, M. Y. (2009) · The FASEB Journal · doi:10.1096/fj.08-117614 · Cited by 155
“Singly charged monoisotopic peptide masses were generated and used as inputs for database searching using MoverZ software (ProteoMetrics, New York, NY, USA), after external and internal calibration of spectra (36).”
MethodKöcher, T., Pichler, P., Schutzbier, M., Stingl, C., Kaul, A., Teucher, N., Hasenfuss, G., Penninger, J. M., & Mechtler, K. (2009) · Journal of Proteome Research · doi:10.1021/pr900451u · Cited by 152
Electron capture/transfer versus collisionally activated/induced dissociations: Solo or duet?
Zubarev, R. A., Zubarev, A. R., & Savitski, M. M. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.03.007 · Cited by 172
“For more on the benefits of mass accuracy see Zubarev and Mann [51].”
BackgroundSelf-citationComparison of modification sites formed on human serum albumin at various stages of glycation
Barnaby, O. S., Cerny, R. L., Clarke, W., & Hage, D. S. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.10.018 · Cited by 144
“A maximum allowable difference (or error) of 25 ppm in the measured masses, representing 2 times the precision of the experimentally-measured mass deviation for unmodified peptides, was found to be sufficient for matching the actual and predicted peptide masses when this technique was used [42].”
Post-translational Modifications and Mass Spectrometry Detection
Silva, A. M. N., Vitorino, R. M. P., Domingues, M. R., Spickett, C. M., & Domingues, P. M. (2013) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2013.08.184 · Cited by 164
“Nevertheless, it is now considered that high resolving power and mass accuracy are essential for proteomics and PTM analysis (43, 44).”
BackgroundSoftware Lock Mass by Two-Dimensional Minimization of Peptide Mass Errors
Cox, J., Michalski, A., & Mann, M. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0142-8 · Cited by 137
“Several definitions of mass accuracy are commonly used, and this important parameter is often only assessed anecdotally [5].”
BackgroundSelf-citationSolid Tumor Proteome and Phosphoproteome Analysis by High Resolution Mass Spectrometry
Zanivan, S., Gnad, F., Wickström, S. A., Geiger, T., Macek, B., Cox, J., Fässler, R., & Mann, M. (2008) · Journal of Proteome Research · doi:10.1021/pr800599n · Cited by 134
Self-citationFlach, H., Rosenbaum, M., Duchniewicz, M., Kim, S., Zhang, S. L., Cahalan, M. D., Mittler, G., & Grosschedl, R. (2010) · Immunity · doi:10.1016/j.immuni.2010.11.013 · Cited by 118
Identifying the Unknowns by Aligning Fragmentation Trees
Rasche, F., Scheubert, K., Hufsky, F., Zichner, T., Kai, M., Svatoš, A., & Böcker, S. (2012) · Analytical Chemistry · doi:10.1021/ac300304u · Cited by 117
Algorithms for thede novosequencing of peptides from tandem mass spectra
Allmer, J. (2011) · Expert Review of Proteomics · doi:10.1586/epr.11.54 · Cited by 132
“See Zubarev and Mann for a disam big-uation of mass accuracy and its proper usage [36] .”
BackgroundAccurate Mass Measurements in Proteomics
Liu, T., Belov, M. E., Jaitly, N., Qian, W.-J., & Smith, R. D. (2007) · Chemical Reviews · doi:10.1021/cr068288j · Cited by 104
De Novo Sequencing Methods in Proteomics
Hughes, C., Ma, B., & Lajoie, G. (2009) · Methods in molecular biology · doi:10.1007/978-1-60761-444-9_8 · Cited by 109
Davis, S. A., Charles, P. D., He, L., Mowlds, P., Kessler, B. M., & Fischer, R. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00915 · Cited by 87
“However, the “ no enzyme ” database searches bene fi t from high mass accuracy MS/MS spectra, 44 so we modi fi ed the Universal Method to replace the low mass accuracy CID/IT scans for MS/MS data acquisition for 2 HCD/FT scan types recognizing singly charged and multiple charged ions.”
Proteins, Lipids, and Water in the Gas Phase
van der Spoel, D., Marklund, E. G., Larsson, D. S. D., & Caleman, C. (2011) · Macromolecular Bioscience · doi:10.1002/mabi.201000291 · Cited by 89
Arena, S., Salzano, A. M., Renzone, G., D'Ambrosio, C., & Scaloni, A. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21378 · Cited by 84
Plant proteomics: Concepts, applications, and novel strategies for data interpretation
Baginsky, S. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20183 · Cited by 101
Nagaraj, N., Lu, A., Mann, M., & Wiśniewski, J. R. (2008) · Journal of Proteome Research · doi:10.1021/pr800412j · Cited by 83
Self-citationQuantitative proteomics as a new piece of the systems biology puzzle
Bachi, A., & Bonaldi, T. (2008) · Journal of Proteomics · doi:10.1016/j.jprot.2008.07.001 · Cited by 93
Global proteomics analysis of testis and ovary in adult zebrafish (Danio rerio)
Groh, K. J., Nesatyy, V. J., Segner, H. E., Eggen, R. I. L., & Suter, M. J. ‐. (2011) · Fish Physiology and Biochemistry · doi:10.1007/s10695-010-9464-x · Cited by 82
“A slightly modified recalibration procedure suggested previously (Zubarev and Mann 2007) was used to eliminate the systematic mass errors.”
MethodBosshard, F., Armand, F., Hamelin, R., & Kohn, T. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.03457-12 · Cited by 90
Schober, Y., Schramm, T., Spengler, B., & Römpp, A. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5135 · Cited by 72
“The terms ‘mass deviation’, ‘mass accuracy’ and ‘maximum mass deviation’ are used according to the definition by Zubarev and Mann[28] in this article.”
MethodBrosch, M., Swamy, S., Hubbard, T., & Choudhary, J. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700293-mcp200 · Cited by 72
“A similar mass error correction method was described by Zubarev and Mann (19).”
MethodCox, J., & Mann, M. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.05.007 · Cited by 85
“Indeed, as we have argued before, the very concept of mass accuracy in proteomics has not been well defined, and various definitions of the term have been used [10].”
BackgroundSelf-citationZhang, L., Yu, C. R., Vasquez, F. E., Galeva, N., Onyango, I. G., Swerdlow, R. H., & Dobrowsky, R. T. (2009) · Journal of Proteome Research · doi:10.1021/pr900818g · Cited by 75
Boyne, M. T., Garcia, B. A., Li, M., Zamdborg, L., Wenger, C. D., Babai, S., & Kelleher, N. L. (2009) · Journal of Proteome Research · doi:10.1021/pr800635m · Cited by 67
To Be or Not to Be? Five Guidelines to Avoid Misassignments in Cross-Linking/Mass Spectrometry
Iacobucci, C., & Sinz, A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02316 · Cited by 64
Zhang, B., Pirmoradian, M., Chernobrovkin, A., & Zubarev, R. A. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o114.038877 · Cited by 57
“But real breakthroughs in MS-based deep proteomics analysis can only come from hardware advances, such as higher acquisition rate (5), sensitivity (44), and mass accuracy (18), as well as better peptide separation (2), ionization (45), fragmentation (38), etc.”
BackgroundSelf-citationQuantitative Analysis of HGF and EGF-Dependent Phosphotyrosine Signaling Networks
Hammond, D. E., Hyde, R., Kratchmarova, I., Beynon, R. J., Blagoev, B., & Clague, M. J. (2010) · Journal of Proteome Research · doi:10.1021/pr100145w · Cited by 54
Pernemalm, M., Orre, L. M., Lengqvist, J., Wikström, P., Lewensohn, R., & Lehtiö, J. (2008) · Journal of Proteome Research · doi:10.1021/pr700821k · Cited by 57
Global Identification of Protein Post-translational Modifications in a Single-Pass Database Search
Shortreed, M. R., Wenger, C. D., Frey, B. L., Sheynkman, G., Scalf, M., Keller, M. P., Attie, A., & Smith, L. M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00599 · Cited by 60
Petyuk, V. A., Mayampurath, A. M., Monroe, M. E., Polpitiya, A. D., Purvine, S. O., Anderson, G. A., Camp, D. G., & Smith, R. D. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900217-mcp200 · Cited by 53
“As noted earlier, a stricter requirement for the maximum allowable parent ion mass deviation serves to improve discrimination between true and false peptide identifications (8, 11, 12, 18).”
BackgroundHigh Accuracy Mass Spectrometry in Large-Scale Analysis of Protein Phosphorylation
Olsen, J. V., & Maček, B. (2009) · Methods in molecular biology · doi:10.1007/978-1-59745-493-3_7 · Cited by 56
Shen, Y., Tolić, N., Hixson, K. K., Purvine, S. O., Paša‐Tolić, L., Qian, W., Adkins, J., Moore, R., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac702328x · Cited by 54
Wang, Y., Meriin, A. B., Costello, C. E., & Sherman, M. Y. (2007) · Prion · doi:10.4161/pri.1.2.4440 · Cited by 50
Calibration function for the orbitrap FTMS accounting for the space charge effect
Gorshkov, M. V., Good, D. M., Lyutvinskiy, Y., Yang, H., & Zubarev, R. A. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.06.021 · Cited by 53
“Both approaches benefit from high mass accuracy [5–7].”
BackgroundSelf-citationNa, S., Jeong, J., Park, H., Lee, K., & Paek, E. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800101-mcp200 · Cited by 51
“Standard Deviation of Mass Errors of Matched Fragment Ions—In MS instruments with high mass accuracy, mass measurement errors can be systematically predicted (32).”
BackgroundPrevišić, A., Rožman, M., Mor, J., Acuña, V., Serra-Compte, A., Petrović, M., & Sabater, S. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.135333 · Cited by 58
Analysis of environmental stress response on the proteome level
Nesatyy, V. J., & Suter, M. J. ‐. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20177 · Cited by 57
Ubiquitinated Proteome: Ready for Global?
Shi, Y., Xu, P., & Qin, J. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r110.006882 · Cited by 51
“Use of high mass accuracy mass spectrometers for proteome-wide PTM mapping (45) is always preferable.”
BackgroundPetyuk, V. A., Jaitly, N., Moore, R. J., Ding, J., Metz, T. O., Tang, K., Monroe, M. E., Tolmachev, A. V., Adkins, J. N., Belov, M. E., et al. (2008) · Analytical Chemistry · doi:10.1021/ac701863d · Cited by 46
Neutron Encoded Labeling for Peptide Identification
Rose, C. M., Merrill, A. E., Bailey, D. J., Hebert, A. S., Westphall, M. S., & Coon, J. J. (2013) · Analytical Chemistry · doi:10.1021/ac400476w · Cited by 45
Improving Proteomics Mass Accuracy by Dynamic Offline Lock Mass
Zhang, Y., Wen, Z., Washburn, M. P., & Florens, L. (2011) · Analytical Chemistry · doi:10.1021/ac201867h · Cited by 44
Ding, Y., Choi, H., & Nesvizhskii, A. I. (2008) · Journal of Proteome Research · doi:10.1021/pr800484x · Cited by 42
“The ability to more accurately calculate the precursor ion mass would also affect the choice of the optimal search conditions 40–43 .”
BackgroundLu, A., Wiśniewski, J. R., & Mann, M. (2009) · Journal of Proteome Research · doi:10.1021/pr8010364 · Cited by 47
Self-citationScherl, A., Tsai, Y. S., Shaffer, S. A., & Goodlett, D. R. (2008) · PROTEOMICS · doi:10.1002/pmic.200800045 · Cited by 41
“Collectively, the potential use of such high measured mass accuracy is well recognized by the mass spectrometry community [14].”
BackgroundWenger, C. D., McAlister, G. C., Xia, Q., & Coon, J. J. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900541-mcp200 · Cited by 43
“Achievement of higher mass measurement accuracy (21, 22) is one of the most straightforward ways to add specificity to database searching (1, 23, 24), allows more efficient de novo sequencing (25–28), and could perhaps facilitate alternative data acquisition and analysis strategies such as those that do not require co…”
BackgroundAbiotic Stress Responses in Plants: Metabolism to Productivity
Macedo, A. F. (2011) · Springer eBooks · doi:10.1007/978-1-4614-0634-1_3 · Cited by 46
McIntyre, J., & Woodgate, R. (2015) · DNA repair · doi:10.1016/j.dnarep.2015.02.011 · Cited by 48
Nestler, H., Groh, K. J., Schönenberger, R., Eggen, R. I. L., & Suter, M. J. ‐. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.06.017 · Cited by 46
Assessing peptide de novo sequencing algorithms performance on large and diverse data sets
Pitzer, E., Masselot, A., & Colinge, J. (2007) · PROTEOMICS · doi:10.1002/pmic.200700224 · Cited by 39
“All the thresholds appear in Table 1 and mass accuracy was determined by plotting error distributions [11].”
MethodCollision-induced reporter fragmentations for identification of covalently modified peptides
Hung, C., Schlösser, A., Wei, J., & Lehmann, W. D. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1449-y · Cited by 39
Effects of Lead and Mercury on the Blood Proteome of Children
Birdsall, R. E., Kiley, M. P., Segu, Z. M., Palmer, C. D., Maděra, M., Gump, B. B., MacKenzie, J. A., Parsons, P. J., Mechref, Y. S., Novotný, M. V., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr100204g · Cited by 43
Functional proteomics in histone research and epigenetics
Trelle, M. B., & Jensen, O. N. (2007) · Expert Review of Proteomics · doi:10.1586/14789450.4.4.491 · Cited by 36
Harkness, L., Christiansen, H., Nehlin, J. O., Barington, T., Andersen, J., & Kassem, M. S. (2008) · Stem Cell Research · doi:10.1016/j.scr.2008.06.001 · Cited by 36
“7 ppm (Zubarev and Mann, 2007), in concert with accuracies given in several high-quality reports of proteome analyses (Adachi et al.”
BackgroundBayesian Nonparametric Model for the Validation of Peptide Identification in Shotgun Proteomics
Zhang, J., Ma, J., Dou, L., Wu, S., Qian, X., Xie, H., Zhu, Y., & He, F. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700558-mcp200 · Cited by 35
“Mass accuracy filtering was proposed for this high accuracy data (35, 36).”
MethodAlternative flagellar filament types in the haloarchaeon Haloarcula marismortui
Pyatibratov, M. G., Beznosov, S. N., Rachel, R., Tiktopulo, E. I., Surin, A. K., Syutkin, A. S., & Fedorov, O. (2008) · Canadian Journal of Microbiology · doi:10.1139/w08-076 · Cited by 36
“We used Mascot scores (M-score) as one of the conventional validity measures in database searches of MS/MS data (Zubarev and Mann 2007).”
MethodMass Spectrometric Investigation of Molecular Variability of Grass Pollen Group 1 Allergens
Fenaille, F., Nony, E., Chabre, H., Lautrette, A., Couret, M.-N., Batard, T., Moingeon, P. E., & Ezan, É. (2009) · Journal of Proteome Research · doi:10.1021/pr900359p · Cited by 36
How much peptide sequence information is contained in ion trap tandem mass spectra?
Cox, J., Hubner, N. C., & Mann, M. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.07.024 · Cited by 40
“The graph indicates that the commonly used maximum mass deviation [16] of 0.”
MethodSelf-citationProtein identification in mass-spectrometry imaging
Mascini, N. E., & Heeren, R. M. A. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.06.008 · Cited by 36
Aizikov, K., Mathur, R., & O’Connor, P. B. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.09.028 · Cited by 37
“In general, requirements for higher mass accuracy and resolving power of the contemporary mass spectrometers are becoming more and more pronounced [9].”
Pinpointing Phosphorylation Sites: Quantitative Filtering and a Novel Site-specific x-Ion Fragment
Kelstrup, C. D., Hekmat, O., Francavilla, C., & Olsen, J. V. (2011) · Journal of Proteome Research · doi:10.1021/pr200154t · Cited by 38
Mass calibration options for accurate electrospray ionization mass spectrometry
Romson, J., & Emmer, Å. (2021) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2021.116619 · Cited by 36
Hoehenwarter, W., Larhlimi, A., Hummel, J., Egelhofer, V., Selbig, J., van Dongen, J. T., Wienkoop, S., & Weckwerth, W. (2011) · Journal of Proteome Research · doi:10.1021/pr101109a · Cited by 32
Lengqvist, J., Eriksson, H., Gry, M., Uhlén, K., Björklund, C., Bjellqvist, B., Jakobsson, P., & Lehtiö, J. (2010) · Amino Acids · doi:10.1007/s00726-010-0704-2 · Cited by 31
“Further, the measured precursor ion mass, especially when measured with high mass accuracy, is very informative and it is the primary database search constraint to limit the search space (Zubarev and Mann 2007).”
BackgroundKalli, A., & Håkansson, K. (2008) · Journal of Proteome Research · doi:10.1021/pr800038y · Cited by 35
Bakker, B., Vaes, R. D. W., Aberle, M. R., Welbers, T. T. J., Hankemeier, T., Rensen, S. S., Damink, S. W. M. O., & Heeren, R. M. A. (2022) · Nature Protocols · doi:10.1038/s41596-021-00661-8 · Cited by 30
A Novel Chromatographic Method Allows On-line Reanalysis of the Proteome
Waanders, L. F., Almeida, R., Prosser, S., Cox, J., Eikel, D., Allen, M. H., Schultz, G. A., & Mann, M. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800141-mcp200 · Cited by 29
“The initial maximum allowed mass deviation (13) was set to 5 ppm for monoisotopic precursor ions and 0.”
Self-citationWarda, M., Prince, A. M., Kim, H. K., Khafaga, N., Scholkamy, T. H., Linhardt, R. J., & Han, J. (2013) · Journal of Advanced Research · doi:10.1016/j.jare.2013.03.004 · Cited by 29
“Further gel analysis was performed as previously described [8,9] and listed in Supplementary data sheet 2.”
MethodProteomic Analysis of Cellular Systems
Hein, M. Y., Sharma, K., Cox, J., & Mann, M. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-385944-0.00001-0 · Cited by 45
Self-citationQuantitative proteomics: a tool to assess cell differentiation
Vermeulen, M., & Selbach, M. (2009) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2009.09.003 · Cited by 33
“The higher the mass accuracy of the instrument, the greater is the confidence in the identification [9].”
Osman, K. M., Ali, M. M., Radwan, M. I., Kim, H. K., & Han, J. (2009) · Journal of Proteomics · doi:10.1016/j.jprot.2009.05.002 · Cited by 28
Tolmachev, A. V., Monroe, M. E., Purvine, S. O., Moore, R., Jaitly, N., Adkins, J., Anderson, G., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac801376g · Cited by 27
A method to identify and quantify the complete peptide composition in protein hydrolysates
Vreeke, G. J. C., Lubbers, W. D., Vincken, J., & Wierenga, P. A. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339616 · Cited by 28
Lichti, C. F., Vigneron, N., Clauser, K. R., den Eynde, B. J. V., & Bassani‐Sternberg, M. (2022) · Cancer Immunology Research · doi:10.1158/2326-6066.cir-21-0727 · Cited by 25
Metadata
- Authors
- Zubarev, R., & Mann, M.
- Affiliations
- Uppsala University (SE)
- Max Planck Institute of Biochemistry (DE)
- Corresponding author
- Zubarev, Roman
- Mann, Matthias
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2007-03
- Volume
- 6
- Issue
- 3
- Pages
- 377-381
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2150371256
- Cited by
- 165
- References
- 15
- Citations by year
- 2025: 2 · 2024: 2 · 2022: 5 · 2021: 1 · 2020: 3 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 3 · 2015: 5 · 2014: 5 · 2013: 17 · 2012: 15
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor, 4921 d)
- Locations
- Molecular & Cellular Proteomics (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- mass accuracy, mass spectrometry, proteomics, database searching, internal standard, mass calibration, mass error, peptide identification
- MeSH terms
- Mass Spectrometry, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.