Bioaerosol sampling: Classical approaches, advances, and perspectives
Open accessThe DOI matches its Crossref record; 170 of the 170 references it cites were found in a registry or an index.
Abstract
Bioaerosol sampling is an essential and integral part of any bioaerosol investigation. Since bioaerosols are very diverse in terms of their sizes, species, biological properties, and requirements for their detection and quantification, bioaerosol sampling is an active, yet challenging research area. This paper was inspired by the discussions during the 2018 International Aerosol Conference (IAC) (St. Louis, MO) regarding the need to summarize the current state of the art in bioaerosol research, including bioaerosol sampling, and the need to develop a more standardized set of guidelines for protocols used in bioaerosol research. The manuscript is a combination of literature review and perspectives: it discusses the main bioaerosol sampling techniques and then overviews the latest technical developments in each area; the overview is followed by the discussion of the emerging trends and developments in the field, including personal sampling, application of passive samplers, and advances toward improving bioaerosol detection limits as well as the emerging challenges such as collection of viruses and collection of unbiased samples for bioaerosol sequencing. The paper also discusses some of the practical aspects of bioaerosol sampling with particular focus on sampling aspects that could lead to bioaerosol determination bias. The manuscript concludes by suggesting several goals for bioaerosol sampling and development community to work towards and describes some of the grand bioaerosol challenges discussed at the IAC 2018.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
AN AUTOMATIC VOLUMETRIC SPORE TRAP
HIRST, J. M. (1952) · Annals of Applied Biology · doi:10.1111/j.1744-7348.1952.tb00904.x · Cited by 1,774 · cited 1×
“Hirst spore traps (Hirst 1952) offer an automated collection of pollen.”
BackgroundNIOSH manual of analytical methods.
(1981) · doi:10.26616/nioshpub82100 · Cited by 1,362
NEW SAMPLER FOR THE COLLECTION, SIZING, AND ENUMERATION OF VIABLE AIRBORNE PARTICLES,
Andersen, A. A. (1958) · Journal of Bacteriology · doi:10.1128/jb.76.5.471-484.1958 · Cited by 1,311 · cited 2×
“Probably the best-known impactor is the Andersen multistage impactor, which was introduced in 1958 (Andersen 1958).”
BackgroundBioaerosol Health Effects and Exposure Assessment: Progress and Prospects
(2003) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meg032 · Cited by 1,232 · cited 2×
“tigation of adverse health effects (Douwes et al. 2003), bioaerosol role in environmental processes, such as cloud formation or ice nucleation (Smets et al.”
BackgroundBioaerosols in the Earth system: Climate, health, and ecosystem interactions
Fröhlich-Nowoisky, J., Kampf, C. J., Weber, B., Huffman, J. A., Pöhlker, C., Andreae, M. O., Lang-Yona, N., Burrows, S. M., Gunthe, S. S., Elbert, W., et al. (2016) · Atmospheric Research · doi:10.1016/j.atmosres.2016.07.018 · Cited by 1,007
Pandemic Preparedness and Response — Lessons from the H1N1 Influenza of 2009
Fineberg, H. V. (2014) · New England Journal of Medicine · doi:10.1056/nejmra1208802 · Cited by 562
Methods for Sampling of Airborne Viruses
Verreault, D., Moineau, S., & Duchaine, C. (2008) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00002-08 · Cited by 469 · cited 3×
“Gelatin filters are also used, but their performance could be negatively affected by too-low or too-high humidity (Verreault, Moineau, and Duchaine 2008).”
BackgroundMeasurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423 · cited 2×
“On the other hand, the same personal cyclone successfully recovered viral RNA in the cough aerosols from 32 of 38 influenza-positive patients (Lindsley et al. 2010).”
BackgroundSeasonal Variability in Bacterial and Fungal Diversity of the Near-Surface Atmosphere
Bowers, R. M., Clements, N., Emerson, J. B., Wiedinmyer, C., Hannigan, M. P., & Fierer, N. (2013) · Environmental Science & Technology · doi:10.1021/es402970s · Cited by 419 · cited 2×
“5 and PM10 fractions was found to be different (Bowers et al. 2013; Fan et al. 2019).”
BackgroundGhosh, B., Lal, H., & Srivastava, A. (2015) · Environment International · doi:10.1016/j.envint.2015.09.018 · Cited by 376 · cited 2×
“The traditional application of passive sampling is the use of settling agar plates (Ghosh, Lal, and Srivastava 2015) to determine culturable bioaerosols.”
BackgroundAirborne bacteria in the atmosphere: Presence, purpose, and potential
Smets, W., Moretti, S., Denys, S., & Lebeer, S. (2016) · Atmospheric Environment · doi:10.1016/j.atmosenv.2016.05.038 · Cited by 337 · cited 2×
“2003), bioaerosol role in environmental processes, such as cloud formation or ice nucleation (Smets et al. 2016), their presence at high altitudes (Smith et al.”
BackgroundHumans differ in their personal microbial cloud
Meadow, J. F., Altrichter, A. E., Bateman, A. C., Stenson, J., Brown, G., Green, J. L., & Bohannan, B. J. M. (2015) · PeerJ · doi:10.7717/peerj.1258 · Cited by 266 · cited 2×
“Stationary and portable bioaerosol samplers determine the presence of bioaerosols in our surrounding environments but may not accurately represent personal exposures to bioaerosols, especially given that humans differ in their personal microbial cloud (Meadow et al. 2015).”
BackgroundSoot Particle Studies—Instrument Inter-Comparison—Project Overview
Cross, E. S., Onasch, T. B., Ahern, A., Wrobel, W., Slowik, J. G., Olfert, J., Lack, D. A., Massoli, P., Cappa, C. D., Schwarz, J. P., et al. (2010) · Aerosol Science and Technology · doi:10.1080/02786826.2010.482113 · Cited by 256 · cited 1×
“Such instrument calibration workshops have been successfully performed in other fields, including particle measurements (Cross et al. 2010).”
BackgroundPauvert, C., Buée, M., Laval, V., Edel-Hermann, V., Fauchery, L., Gautier, A., Lesur, I., Vallance, J., & Vacher, C. (2019) · Fungal Ecology · doi:10.1016/j.funeco.2019.03.005 · Cited by 253
Improved Aerosol Collection by Combined Impaction and Centrifugal Motion
willeke, K., Lin, X., & Grinshpun, S. A. (1998) · Aerosol Science and Technology · doi:10.1080/02786829808965536 · Cited by 247 · cited 1×
“These concerns led to the development of a liquid-based swirling air sampler— marketed as the BioSampler (SKC Inc., Eighty Four, PA)—which combines impingement with centrifugal motion (Willeke, Lin, and Grinshpun 1998).”
BackgroundEffect of impact stress on microbial recovery on an agar surface
Stewart, S. L., Grinshpun, S. A., Willeke, K., Terzieva, S., Ulevicius, V, & Donnelly, J. (1995) · Applied and Environmental Microbiology · doi:10.1128/aem.61.4.1232-1239.1995 · Cited by 237 · cited 2×
“In addition, impaction subjects airborne microorganisms to sudden deceleration and that damages them, including the loss of culturability (Stewart et al. 1995; Wang et al. 2001) and even membrane integrity (Zhen et al. 2013) thus further reducing the fraction of culturable microorganisms that can…”
BackgroundBioaerosol sampling: sampling mechanisms, bioefficiency and field studies
Haig, C. W., Mackay, W. G., Walker, J. T., & Williams, C. (2016) · Journal of Hospital Infection · doi:10.1016/j.jhin.2016.03.017 · Cited by 228 · cited 4×
“In order to compare results from different indoor sites, a 1/1/1 scheme has been adopted, where the “1”s refer to the placement of a 90mm Petri dish at the height of 1 m, 1 m away from any wall and 1 h sampling (Haig et al. 2016).”
BackgroundInfluentialHogan, C. J., Kettleson, E. M., Lee, M.-H., Ramaswami, B., Angenent, L. T., & Biswas, P. (2005) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2005.02720.x · Cited by 223 · cited 1×
“AGI-30 and the BioSampler collectors have been used to collect viruses, but their physical capture efficiency for viruses is low (Hogan et al. 2005).”
MethodButtner, M. P., & Stetzenbach, L. D. (1993) · Applied and Environmental Microbiology · doi:10.1128/aem.59.1.219-226.1993 · Cited by 216 · cited 1×
“While this method is non-quantitative due to the indeterminate air volume and often does not compare favorably against active sampling methods (Buttner and Stetzenbach 1993; Sayer, MacKnight, and Wilson 1972; Sayer, Shean, and Ghosseiri 1969; Solomon 1975), it is still widely used in contamination…”
MethodWang, Z., Reponen, T., A. Grinshpun, S., L. Górny, R., & Willeke, K. (2001) · Journal of Aerosol Science · doi:10.1016/s0021-8502(00)00108-7 · Cited by 213
EVALUATION OF EIGHT BIOAEROSOL SAMPLERS CHALLENGED WITH AEROSOLS OF FREE BACTERIA
Jensen, P. A., Todd, W. F., Davis, G. N., & Scarpino, P. V. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360319 · Cited by 212 · cited 1×
“However, the latter can also become a disadvantage as air passing through filters desiccates the collected particles (Grinshpun et al. 2015; Jensen et al. 1992; Lundholm 1982; Thorne et al. 1992; Wang et al. 2001) minimizing sample recovery via culture methods.”
BackgroundAmato, P., Hennebelle, R., Magand, O., Sancelme, M., Delort, A.-M., Barbante, C., Boutron, C., & Ferrari, C. (2007) · FEMS Microbiology Ecology · doi:10.1111/j.1574-6941.2006.00198.x · Cited by 200 · cited 2×
“Here, rain (Kang, Heo, and Lee 2015), accumulated snow (Amato et al. 2007) and hailstones (Mandrioli et al.”
BackgroundHealth Effects of Mycotoxins in Indoor Air: A Critical Review
Robbins, C. A., Swenson, L. J., Nealley, M. L., Kelman, B. J., & Gots, R. E. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050129419 · Cited by 197 · cited 2×
“2008) and leave out viable but not culturable microorganisms (VNBC), and non-viable microorganisms which could still cause health effects (Robbins et al. 2000; Speight et al. 1997).”
BackgroundNoss, I., Wouters, I. M., Visser, M., Heederik, D. J. J., Thorne, P. S., Brunekreef, B., & Doekes, G. (2008) · Applied and Environmental Microbiology · doi:10.1128/aem.00619-08 · Cited by 193 · cited 2×
“Electrostatic dust fall collectors (EDC) which use electrostatic cloths (Noss et al. 2008) were used to examine 2-week long exposures to endotoxin (Liebers et al. 2012).”
MethodComparison of bioaerosol sampling methods in barns housing swine
Thorne, P. S., Kiekhaefer, M. S., Whitten, P., & Donham, K. J. (1992) · Applied and Environmental Microbiology · doi:10.1128/aem.58.8.2543-2551.1992 · Cited by 188 · cited 1×
“However, the latter can also become a disadvantage as air passing through filters desiccates the collected particles (Grinshpun et al. 2015; Jensen et al. 1992; Lundholm 1982; Thorne et al. 1992; Wang et al. 2001) minimizing sample recovery via culture methods.”
BackgroundPerformance of bioaerosol samplers: collection characteristics and sampler design considerations
Nevalainen, A. I., Pastuszka, J. S., Liebhaber, F. B., & Willeke, K. (1992) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(92)90166-i · Cited by 184 · cited 1×
“A description of how to calculate an optimal sampling time has been presented elsewhere (Nevalainen et al. 1992).”
BackgroundThe Aerobiological Pathway of Microorganisms
Cox, C. S. (1988) · 1988 · doi:10.1515/9783112581803-016 · Cited by 181 · cited 1×
“The AGI has a long, curved inlet designed to simulate the nasal passage and its capture of inhaled particles (Cox 1987; Grinshpun et al. 1994; Jensen et al. 1994).”
BackgroundCollection efficiencies of aerosol samplers for virus-containing aerosols
Tseng, C., & Li, C.-S. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.12.004 · Cited by 177 · cited 1×
“The hydrophilic viruses were captured 10–100 more efficiently than hydrophobic viruses when using traditional samplers such as the Andersen impactor, AGI-30 impinger, gelatin filter, and Nuclepore filter (Tseng and Li 2005).”
MethodThe ecology of bacteria in the alfresco atmosphere
Lighthart, B. (2006) · FEMS Microbiology Ecology · doi:10.1111/j.1574-6941.1997.tb00408.x · Cited by 173 · cited 1×
“However, the literature suggests that low d50 might be not as critical when sampling environmental bacteria as most of them are larger than 2mm because they tend to be attached to other particles (Lighthart 1997).”
BackgroundPhysical Collection Efficiency of Filter Materials for Bacteria and Viruses
(2006) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mel073 · Cited by 167 · cited 2×
“…mixed cellulose ester, polytetrafluoroethylene (Teflon, PTFE), polyvinyl chloride (PVC), nylon, gelatin, and other filter types have been used for bioaerosol sampling depending on the selected analysis technique (Burton, Grinshpun, and Reponen 2007; Li et al. 2018; Van Droogenbroeck et al. 2009).”
BackgroundMethodSurvival of Airborne Microorganisms During Swirling Aerosol Collection
Lin, X., Reponen, T., Willeke, K., Wang, Z., Grinshpun, S. A., & Trunov, M. (2000) · Aerosol Science and Technology · doi:10.1080/027868200303722 · Cited by 163 · cited 1×
“While AGI impingers are efficient collectors with d50 of 0.3 mm, the collection liquid evaporates in about 90min (Lin et al. 1997), and high impingement velocities lead to microorganism damage and reaerosolization (Lin et al. 2000).”
BackgroundInfluentialInnovations in air sampling to detect plant pathogens
West, J. S., & Kimber, R. B. E. (2015) · Annals of Applied Biology · doi:10.1111/aab.12191 · Cited by 162 · cited 1×
“…processes, such as cloud formation or ice nucleation (Smets et al. 2016), their presence at high altitudes (Smith et al. 2018), bioaerosol–ecosystems interactions (Fr€ohlich-Nowoisky et al. 2016), and transmission of plant disease (Parker, McDonald, and Boland 2013; West and Kimber 2015).”
BackgroundUrban greenness influences airborne bacterial community composition
Mhuireach, G., Johnson, B. R., Altrichter, A. E., Ladau, J., Meadow, J. F., Pollard, K. S., & Green, J. L. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.07.037 · Cited by 156 · cited 1×
“An outdoor study found that settling plates had captured higher biomass compared to an active Button sampler and that the alpha diversity results between the two samplers were similar (Mhuireach et al. 2016).”
Comparison of sampling methods for the assessment of indoor microbial exposure
Frankel, M., Timm, M., Hansen, E. W., & Madsen, A. M. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00770.x · Cited by 148 · cited 1×
“EDC yielded higher levels of fungi and endotoxin compared to dust fall collector, which is gravity only based device (Frankel et al. 2012).”
BackgroundCollection of Airborne Microorganisms by Electrostatic Precipitation
Mainelis, G. (1999) · Aerosol Science and Technology · doi:10.1080/027868299304732 · Cited by 147 · cited 2×
“particle deposition velocity compared to inertia-based methods (Mainelis et al. 1999), leading to less microorganism damage (Zhen et al.”
BackgroundMethodSelf-citationDuquenne, P., Marchand, G., & Duchaine, C. S. (2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mes051 · Cited by 137 · cited 1×
“Study personnel should consult the literature for best sampling practices in specific environments, such as healthcare (Haig et al. 2016), or when sampling for specific bioaerosols, for example, viruses (Verreault, Moineau, and Duchaine 2008) or endotoxin (Duquenne, Marchand, and Duchaine 2013).”
BackgroundLong-term sampling of airborne bacteria and fungi into a non-evaporating liquid
Lin, X., Reponen, T. A., Willeke, K., Grinshpun, S. A., Foarde, K. K., & Ensor, D. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00169-7 · Cited by 134 · cited 2×
“Particle losses due to bounce and reaerosolization could be reduced by using viscous collection fluid (Lin et al. 1999; Simon et al. 2016).”
BackgroundEffect of Impaction, Bounce and Reaerosolization on the Collection Efficiency of Impingers
Grinshpun, S. A., Willeke, K., Ulevicius, V., Juozaitis, A., Terzieva, S., Donnelly, J., Stelma, G. N., & Brenner, K. P. (1997) · Aerosol Science and Technology · doi:10.1080/02786829708965434 · Cited by 128 · cited 1×
“For liquid-based samplers, such losses may occur due to particle bounce and reaerosolization (Grinshpun et al. 1997) or due to particle losses to internal sampler surfaces (Han and Mainelis 2012; Kesavan 2012).”
BackgroundCollection of airborne microorganisms by a new electrostatic precipitator
Mainelis, G., Adhikari, A., Willeke, K., Lee, S.-A., Reponen, T. A., & Grinshpun, S. A. (2002) · Journal of Aerosol Science · doi:10.1016/s0021-8502(02)00091-5 · Cited by 126 · cited 1×
“The learned principles were then used to develop and apply a stand-alone ESP for laboratory and field investigations of culturable microorganisms (Lee et al. 2004; Mainelis et al. 2002a; Mainelis et al. 2002b).”
MethodSelf-citationAssessing fungus prevalence in domestic interiors
Solomon, W. R. (1975) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(75)90095-0 · Cited by 125 · cited 2×
“While this method is non-quantitative due to the indeterminate air volume and often does not compare favorably against active sampling methods (Buttner and Stetzenbach 1993; Sayer, MacKnight, and Wilson 1972; Sayer, Shean, and Ghosseiri 1969; Solomon 1975), it is still widely used in contamination sensitive industries…”
MethodEffect of Sampling Time on the Collection Efficiency of All-Glass Impingers
Lin, X., Willeke, K., Ulevicius, V., & Grinshpun, S. A. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012577 · Cited by 124 · cited 1×
“While AGI impingers are efficient collectors with d50 of 0.3 mm, the collection liquid evaporates in about 90min (Lin et al. 1997), and high impingement velocities lead to microorganism damage and reaerosolization (Lin et al. 2000).”
BackgroundInfluentialAssessment of experimental and natural viral aerosols
Gerone, P. J., Couch, R. B., Keefer, G. V., Douglas, R. G., Derrenbacher, E. B., & Knight, V (1966) · Bacteriological Reviews · doi:10.1128/br.30.3.576-588.1966 · Cited by 123
Effects of bioaerosol polluted outdoor air on airways of residents: a cross sectional study
Herr, C. E. W., zur Nieden, A., Jankofsky, M., Stilianakis, N. I., Boedeker, R.-H., & Eikmann, T. F. (2003) · Occupational and Environmental Medicine · doi:10.1136/oem.60.5.336 · Cited by 119
Performance of Air-O-Cell, Burkard, and Button Samplers for Total Enumeration of Airborne Spores
Aizenberg, V., Reponen, T. A., Grinshpun, S. A., & Willeke, K. (2000) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660008984598 · Cited by 118 · cited 3×
“, Eighty Four, PA) were used with various filters, including gelatin, to capture inhalable biological particles (Aizenberg et al. 2000; Chang and Hung 2012; Wu, Shen, and Yao 2010; Yao and Mainelis 2007a).”
MethodA two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling.
Lindsley, W. G., Schmechel, D., & Chen, B. T. (2006) · Journal of Environmental Monitoring · doi:10.1039/b609083d · Cited by 117 · cited 1×
“Researchers from the National Institute for Occupational Safety and Health (NIOSH) recently developed and successfully used in the field a microcentrifuge-tube cyclone (Lindsley, Schmechel, and Chen 2006; Macher, Chen, and Rao 2008; Su et al. 2012b).”
MethodSmith, D. J., Ravichandar, J. D., Jain, S., Griffin, D. W., Yu, H., Tan, Q., Thissen, J. B., Lusby, T. C., Nicoll, P. M., Shedler, S., et al. (2018) · Frontiers in Microbiology · doi:10.3389/fmicb.2018.01752 · Cited by 115 · cited 3×
“2016), their presence at high altitudes (Smith et al. 2018), bioaerosol–ecosystems interactions (Fr€ ohlich-Nowoisky et al.”
BackgroundInfluentialMbareche, H., Veillette, M., Bilodeau, G. J., & Duchaine, C. (2018) · Applied and Environmental Microbiology · doi:10.1128/aem.01589-18 · Cited by 100 · cited 4×
“An electrostatic dry filter was found to consistently yield more fungal and bacterial OTUs compared to two liquid cyclonic samplers (Mbareche et al. 2018).”
BackgroundInfluentialChoi, D. Y., Heo, K. J., Kang, J., An, E. J., Jung, S., Lee, B. U., Lee, H. M., & Jung, J. H. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.02.043 · Cited by 99 · cited 1×
“Washable filters have also been used (Choi et al. 2018).”
Release of Free DNA by Membrane-Impaired Bacterial Aerosols Due to Aerosolization and Air Sampling
Zhen, H., Han, T., Fennell, D. E., & Mainelis, G. (2013) · Applied and Environmental Microbiology · doi:10.1128/aem.02859-13 · Cited by 99 · cited 5×
“One of the main attractive features of electrostatic collectors is their lower particle deposition velocity compared to inertia-based methods (Mainelis et al. 1999), leading to less microorganism damage (Zhen et al. 2013).”
BackgroundInfluentialSelf-citationEvaluation of Six Inhalable Aerosol Samplers
Li, S.-N., Lundgren, D. A., & Rovell-Rixx, D. C. (2000) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660008984562 · Cited by 97 · cited 1×
“Sampling outdoors presents its own set of challenges as wind, and its direction and speed may affect a sampler’s aspiration and collection efficiencies (Li, Lundgren, and Rovell-Rixx 2000).”
BackgroundLundholm, I. M. (1982) · Applied and Environmental Microbiology · doi:10.1128/aem.44.1.179-183.1982 · Cited by 95 · cited 1×
“However, the latter can also become a disadvantage as air passing through filters desiccates the collected particles (Grinshpun et al. 2015; Jensen et al. 1992; Lundholm 1982; Thorne et al. 1992; Wang et al. 2001) minimizing sample recovery via culture methods.”
BackgroundPan, M., Eiguren-Fernández, A., Hsieh, H., Afshar‐Mohajer, N., Hering, S. V., Lednicky, J. A., Fan, Z. H., & Wu, C. (2016) · Journal of Applied Microbiology · doi:10.1111/jam.13051 · Cited by 92 · cited 1×
“Another group used a similar concept of a growth tube collector to capture MS2 coliphages and influenza H1N1 virus (Lednicky et al. 2016; Pan et al. 2016).”
MethodComparing the performance of 3 bioaerosol samplers for influenza virus
Li, J., Leavey, A., Wang, Y., O’Neil, C. A., Wallace, M. A., Burnham, C. D., Boon, A. C. M., Babcock, H. M., & Biswas, P. (2017) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2017.08.007 · Cited by 91 · cited 5×
“A comparative study showed that the BioSampler had collection efficiency at 5% for H1N1 influenza A virus compared to 1.5% efficiency of gelatin filters (Li et al. 2018).”
BackgroundMethodInfluentialFan, C., Li, Y., Liu, P., Mu, F., Xie, Z., Lu, R. M., Qi, Y., Wang, B., & Jin, C. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.03.412 · Cited by 90 · cited 1×
“5 and PM10 fractions was found to be different (Bowers et al. 2013; Fan et al. 2019).”
BackgroundCao, G., Noti, J. D., Blachère, F. M., Lindsley, W. G., & Beezhold, D. H. (2011) · Journal of Environmental Monitoring · doi:10.1039/c1em10607d · Cited by 90 · cited 14×
“Collection efficiency of G-II for influenza virus was reportedly similar to that of BioSampler.”
MethodInfluentialMicrobial Aerosols: Sources, Properties, Health Effects, Exposure Assessment—A Review
Górny, R. L. (2019) · KONA Powder and Particle Journal · doi:10.14356/kona.2020005 · Cited by 89 · cited 1×
“…sample into/onto a sampling medium and then make it available for analysis by culturing (Herr et al. 2003), microscopy, flow cytometry, ATP-based bioluminescence, quantitative polymerase chain reaction (qPCR), gene sequencing and other methods (G orny 2020; Reponen, Willeke, and Grinshpun 2011).”
MethodAirborne Virus Capture and Inactivation by an Electrostatic Particle Collector
Kettleson, E. M., Ramaswami, B., Hogan, C. J., Lee, M., Statyukha, G. A., Biswas, P., & Angenent, L. T. (2009) · Environmental Science & Technology · doi:10.1021/es803289w · Cited by 88 · cited 2×
“Efficient capture of viruses was achieved using ESPs with a novel charging system (Hogan, Lee, and Biswas 2004; Kettleson et al. 2009), including for the use of plaque assays and qPCR.”
MethodSampling and analysis of biological aerosols
Burge, H. A., & Solomon, W. R. (1987) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(87)90026-6 · Cited by 88 · cited 1×
“However, the gravitational settling of particles is affected by their sizes and shapes as well as air motion (Reponen, Willeke, and Grinshpun 2011), and larger particles are preferentially captured (Burge and Solomon 1987).”
BackgroundReponen, T., Willeke, K., Grinshpun, S., & Nevalainen, A. (2011) · Aerosol Measurement · doi:10.1002/9781118001684.ch24 · Cited by 86
Design and Collection Efficiency of a New Electrostatic Precipitator for Bioaerosol Collection
Mainelis, G., Willeke, K., Adhikari, A., Reponen, T. A., & Grinshpun, S. A. (2002) · Aerosol Science and Technology · doi:10.1080/02786820290092212 · Cited by 85 · cited 1×
“The learned principles were then used to develop and apply a stand-alone ESP for laboratory and field investigations of culturable microorganisms (Lee et al. 2004; Mainelis et al. 2002a; Mainelis et al. 2002b).”
MethodSelf-citationŠantl‐Temkiv, T., Amato, P., Gosewinkel, U., Thyrhaug, R., Charton, A., Chicot, B., Finster, K. W., Bratbak, G., & Löndahl, J. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b01480 · Cited by 84 · cited 1×
“An impinger capable of operating at 3100 L/min for 120–300min was shown to retain cultivability, metabolic activity, viability, and ice-nucleation activity of investigated bacteria ( Santl-Temkiv et al. 2017).”
BackgroundDiversity of airborne bacteria in samples collected using different devices for aerosol collection
Fahlgren, C., Bratbak, G., Sandaa, R., Thyrhaug, R., & Zweifel, U. L. (2010) · Aerobiologia · doi:10.1007/s10453-010-9181-z · Cited by 84 · cited 1×
“A field study in a mountainous area and at a seaside used a filter sampler, impactor, and impinger and indicated a good agreement regarding dominant species but not so for less prevalent species (Fahlgren et al. 2011).”
BackgroundInvestigation of Cut-Off Sizes and Collection Efficiencies of Portable Microbial Samplers
Yao, M., & Mainelis, G. (2006) · Aerosol Science and Technology · doi:10.1080/02786820600729146 · Cited by 82 · cited 1×
“Due to power limitations, these impactors are single-stage collectors with d50 larger than 1 mm and high as high 8 mm; however, the use of centrifugal fans allows many of them to sample at flow rates exceeding 100 L/min and as high as 180 L/ min (Yao and Mainelis 2006).”
BackgroundSelf-citationInlet characteristics of bioaerosol samplers
Grinshpun, S. A., Chang, C., Nevalainen, A. I., & Willeke, K. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90221-6 · Cited by 80 · cited 1×
“The AGI has a long, curved inlet designed to simulate the nasal passage and its capture of inhaled particles (Cox 1987; Grinshpun et al. 1994; Jensen et al. 1994).”
BackgroundPassive dust collectors for assessing airborne microbial material
Adams, R. I., Tian, Y., Taylor, J. W., Bruns, T. D., Hyvärinen, A., & Täubel, M. (2015) · Microbiome · doi:10.1186/s40168-015-0112-7 · Cited by 80 · cited 4×
“Passive dust collectors have also been explored for use in sequencing (Adams et al. 2015), and the authors found that plastic Petri dishes produced the highest yields, followed by sampling with an EDC.”
BackgroundInfluentialSampling and Retention Efficiencies of Batch-Type Liquid-Based Bioaerosol Samplers
Kesavan, J. S., Schepers, D. R., & McFarland, A. R. (2010) · Aerosol Science and Technology · doi:10.1080/02786826.2010.497513 · Cited by 79 · cited 1×
“For liquid-based samplers, such losses may occur due to particle bounce and reaerosolization (Grinshpun et al. 1997) or due to particle losses to internal sampler surfaces (Han and Mainelis 2012; Kesavan 2012).”
BackgroundFarnsworth, J. E., Goyal, S. M., Kim, S. W., Kuehn, T. H., Raynor, P. C., Ramakrishnan, M. A., Anantharaman, S., & Tang, W. (2006) · Journal of Environmental Monitoring · doi:10.1039/b606132j · Cited by 79 · cited 1×
“In an emerging trend, filters from Heating Ventilation and Air Conditioning (HVAC) systems are used to analyze bioaerosol presence indoors (Farnsworth et al. 2006; Hoisington et al. 2014; Maestre et al. 2018) and car filters are used to investigate bioaerosol bioburden in mobile environments…”
BackgroundAerosol sampling using an electrostatic precipitator integrated with a microfluidic interface
Pardon, G., Ladhani, L., Sandström, N., Ettori, M., Lobov, G. S., & van der Wijngaart, W. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.02.008 · Cited by 78 · cited 3×
“The work in this area has already yielded exciting prototypes (Choi et al. 2017; Pardon et al. 2015).”
BackgroundAir sampling instruments for evaluation of atmospheric contaminants
Vincent, J. H. (1990) · Journal of Aerosol Science · doi:10.1016/0021-8502(90)90170-3 · Cited by 77
Design and development of an electrostatic sampler for bioaerosols with high concentration rate
Han, T., & Mainelis, G. (2008) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.07.009 · Cited by 77 · cited 1×
“RC close to a million could be achieved by decreasing the amount of collection liquid down to tens or even single microliters as was demonstrated in an electrostatic precipitator with the superhydrophobic surface (EPSS) (Han, An, and Mainelis 2010; Han and Mainelis 2008; Han et al. 2011).”
MethodSelf-citationDevelopment and Performance Evaluation of an Exhaled-Breath Bioaerosol Collector for Influenza Virus
McDevitt, J. J., Koutrakis, P., Ferguson, S. T., Wolfson, J. M., Fabian, M. P., Martins, M., Pantelic, J., & Milton, D. K. (2013) · Aerosol Science and Technology · doi:10.1080/02786826.2012.762973 · Cited by 76 · cited 2×
“A new sampler, called the G-II, collects exhaled-breath particles by using a slit impactor to remove particles larger than 5 mm and then grows the remaining particles up to 1mm to be captured by another slit impactor followed by deposition into a buffer-containing collector (McDevitt et al. 2013).”
BackgroundMethodThe microbial diversity of a storm cloud as assessed by hailstones
Šantl‐Temkiv, T., Finster, K. W., Hansen, B. M., Nielsen, N. W., & Karlson, U. (2012) · FEMS Microbiology Ecology · doi:10.1111/j.1574-6941.2012.01402.x · Cited by 76 · cited 2×
“Here, rain (Kang, Heo, and Lee 2015), accumulated snow (Amato et al. 2007) and hailstones (Mandrioli et al. 1973; Temkiv et al. 2012) have been used to investigate the presence of microorganisms and their temporal signatures.”
MethodLednicky, J. A., Pan, M., Loeb, J. C., Hsieh, H. P., Eiguren-Fernandez, A., Hering, S. V., Fan, Z. H., & Wu, C. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1179254 · Cited by 74 · cited 1×
“Another group used a similar concept of a growth tube collector to capture MS2 coliphages and influenza H1N1 virus (Lednicky et al. 2016; Pan et al. 2016).”
MethodHogan, C. J., Lee, M.-H., & Biswas, P. (2004) · Aerosol Science and Technology · doi:10.1080/02786820490462183 · Cited by 73 · cited 1×
“Efficient capture of viruses was achieved using ESPs with a novel charging system (Hogan, Lee, and Biswas 2004; Kettleson et al. 2009), including for the use of plaque assays and qPCR.”
MethodThe aerobiological pathway of microorganisms
Kaiser, P. (1987) · Research in Microbiology · doi:10.1016/0769-2609(87)90068-8 · Cited by 72
Methods for aeroallergen sampling
Levetin, E. (2004) · Current Allergy and Asthma Reports · doi:10.1007/s11882-004-0088-z · Cited by 72 · cited 1×
“Thus, for multi-nozzle impactors, some studies limit the duration of individual samples to 5min (Levetin 2004).”
BackgroundPerformance of Air-O-Cell, Burkard, and Button Samplers for Total Enumeration of Airborne Spores
Aizenberg, V., Reponen, T. A., Grinshpun, S. A., & Willeke, K. (2000) · American Industrial Hygiene Association Journal · doi:10.1202/0002-8894(2000)061<0855:poaocb>2.0.co;2 · Cited by 72
Development and evaluation of a new personal sampler for culturable airborne microorganisms
Agranovski, I. E., Agranovski, V., Reponen, T. A., Willeke, K., & Grinshpun, S. A. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00488-5 · Cited by 71 · cited 4×
“One example of an alternative design uses a porous medium that is submerged into the liquid to divide the aerosol flow into multiple small air streams that create tiny bubbles and remove particles onto the sampler’s walls (Agranovski et al. 2002a; Agranovski et al. 2002b; Agranovski et al. 2005).”
BackgroundMethodInfluentialAnalysis of Portable Impactor Performance for Enumeration of Viable Bioaerosols
Yao, M., & Mainelis, G. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701407388 · Cited by 69 · cited 7×
“Field comparison showed that agar impactors with large d50 captured similar concentrations of culturable bacteria and fungi compared to impactors with much lower d50 (Yao and Mainelis 2007a).”
BackgroundMethodInfluentialSelf-citationHoisington, A. J., Maestre, J. P., King, M. D., Siegel, J. A., & Kinney, K. A. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.04.021 · Cited by 69 · cited 2×
“…trend, filters from Heating Ventilation and Air Conditioning (HVAC) systems are used to analyze bioaerosol presence indoors (Farnsworth et al. 2006; Hoisington et al. 2014; Maestre et al. 2018) and car filters are used to investigate bioaerosol bioburden in mobile environments (Hurley et al. 2019;…”
BackgroundCodina, R., Fox, R. W., Lockey, R. F., DeMarco, P. J., & Bagg, A. S. (2008) · PubMed · Cited by 68
Filter forensics: microbiota recovery from residential HVAC filters
Maestre, J. P., Jennings, W. C., Wylie, D., Horner, S. D., Siegel, J. A., & Kinney, K. A. (2018) · Microbiome · doi:10.1186/s40168-018-0407-6 · Cited by 67 · cited 3×
“Given the biases that could be introduced by the sampling method, it has been suggested that a sampler’s efficiency and ability to cover microbial diversity be considered when selecting tools to investigate microbial diversity (Maestre et al. 2018).”
BackgroundCox, J., Indugula, R., Vesper, S. J., Zhu, Z., Jandarov, R., & Reponen, T. A. (2017) · Environmental Science Processes & Impacts · doi:10.1039/c7em00257b · Cited by 65 · cited 1×
“It has also been suggested that passive and active sampling could yield very different species diversity based on size of the microorganisms, deposition rates, ventilation in the room, and other parameters (Cox et al. 2017).”
BackgroundKing, M. D., & McFarland, A. R. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.605400 · Cited by 64 · cited 1×
“The authors of the study demonstrated that the recovery of culturable E. coli bacteria was 100 greater compared to a high volume impactor (King and McFarland 2012).”
BackgroundPyankov, O. V., Agranovski, I. E., Pyankova, O. G., Mokhonova, E. I., Mokhonov, V. V., Сафатов, А. С., & Khromykh, A. A. (2007) · Environmental Microbiology · doi:10.1111/j.1462-2920.2006.01226.x · Cited by 64 · cited 11×
“2005), and detect them using real-time PCR (Pyankov et al. 2007).”
MethodInfluentialDevelopment of an Automated Electrostatic Sampler (AES) for Bioaerosol Detection
Tan, M., Shen, F., Yao, M., & Zhu, T. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.582193 · Cited by 64 · cited 1×
“In a similar concept, an electrostatic collector with circulating liquid as a collection substrate was described (Tan et al. 2011).”
BackgroundInvestigation of inherent and latent internal losses in liquid-based bioaerosol samplers
Han, T., & Mainelis, G. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.11.001 · Cited by 63 · cited 2×
“For liquid-based samplers, such losses may occur due to particle bounce and reaerosolization (Grinshpun et al. 1997) or due to particle losses to internal sampler surfaces (Han and Mainelis 2012; Kesavan 2012).”
BackgroundSelf-citationEvaluation of the Andersen Viable Impactor for Single Stage Sampling
Jones, W. G., Morring, K., Morey, P. R., & Sorenson, W. G. (1985) · American Industrial Hygiene Association Journal · doi:10.1080/15298668591394833 · Cited by 63 · cited 1×
“It has been recommended and used as a reference sampler (Chatigny et al. 1989; Griffiths and Stewart 1999; Jones et al. 1985; Yao and Mainelis 2007b) and is the recommended bioaerosol collection method in the NIOSH Manual of Analytical Methods (NIOSH 2017).”
MethodNew personal sampler for viable airborne viruses: feasibility study
Agranovski, I. E., Сафатов, А. С., Borodulin, A. I., Pyankov, O. V., Petrishchenko, V. A., An, S., Aa, S., Agranovski, V., & Grinshpun, S. A. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.11.014 · Cited by 59 · cited 3×
“One example of an alternative design uses a porous medium that is submerged into the liquid to divide the aerosol flow into multiple small air streams that create tiny bubbles and remove particles onto the sampler’s walls (Agranovski et al. 2002a; Agranovski et al. 2002b; Agranovski et al. 2005).”
BackgroundMethodHan, T., An, H. R., & Mainelis, G. (2010) · Aerosol Science and Technology · doi:10.1080/02786821003649352 · Cited by 58 · cited 1×
“RC close to a million could be achieved by decreasing the amount of collection liquid down to tens or even single microliters as was demonstrated in an electrostatic precipitator with the superhydrophobic surface (EPSS) (Han, An, and Mainelis 2010; Han and Mainelis 2008; Han et al. 2011).”
MethodSelf-citationHong, S., Bhardwaj, J., Han, C.-H., & Jang, J. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b03464 · Cited by 58 · cited 14×
“Collection efficiency of G-II for influenza virus was reportedly similar to that of BioSampler.”
BackgroundResultInfluentialReuter Centrifugal Air Sampler: Measurement of Effective Airflow Rate and Collection Efficiency
Macher, J. M., & First, M. W. (1983) · Applied and Environmental Microbiology · doi:10.1128/aem.45.6.1960-1962.1983 · Cited by 57 · cited 1×
“These Reuter Centrifugal Samplers operate at flow rates ranging from 40 to 100 L/min (Grinshpun et al. 2015); however, there were questions regarding the actual sampling flowrates in early models (Macher and First 1983).”
BackgroundRinsoz, T., Duquenne, P., Greff-Mirguet, G., & Oppliger, A. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.05.018 · Cited by 57 · cited 2×
“Culturable methods are essential to determine microorganisms that are “alive,” but they comprise only a fraction of total microorganisms (Rinsoz et al. 2008) and leave out viable but not culturable microorganisms (VNBC), and non-viable microorganisms which could still cause health effects (Robbins et al.”
MethodExperimental Air-Borne Infection
Loosli, C. G. (1948) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.38.7.1022-a · Cited by 56
Sampling for Airborne Microorganisms
Grinshpun, S. A., Buttner, M. P., Mainelis, G., & Willeke, K. (2015) · ASM Press eBooks · doi:10.1128/9781555818821.ch3.2.2 · Cited by 56
Self-citationEnhancing Bioaerosol Sampling by Andersen Impactors Using Mineral-Oil-Spread Agar Plate
Xu, Z., Wei, K., Wu, Y. H., Shen, F., Chen, Q., Li, M., & Yao, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056896 · Cited by 56 · cited 1×
“The bounce in impactors could be minimized by using mineral oil to cover the plates, application of which also enhanced recovery of culturable organisms (Xu et al. 2013).”
BackgroundChoi, J., Hong, S. C., Kim, W., & Jung, J. H. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00753 · Cited by 55 · cited 3×
“ticles into a microfluidic channel and reported the superior microbial recovery of Staphylococcus epidermidis compared to the BioSampler (Choi et al. 2017).”
BackgroundMethodInfluentialPark, J. W., Kim, H. R., & Hwang, J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.08.039 · Cited by 55 · cited 1×
“Similar principles were applied by the same group for continuous and near-real-time bioaerosol detection (Park, Kim, and Hwang 2016) using liquid flow-through.”
MethodSampling and detection of airborne influenza virus towards point-of-care applications
Ladhani, L., Pardon, G., Meeuws, H., Wesenbeeck, L. V., Schmidt, K., Stuyver, L. J., & van der Wijngaart, W. (2017) · PLoS ONE · doi:10.1371/journal.pone.0174314 · Cited by 54 · cited 2×
“An ESP with 150 mL of collection fluid was used to capture influenza viruses for point-of-care applications (Ladhani et al. 2017).”
MethodNEW PERSONAL SAMPLER FOR VIABLE AIRBORNE VIRUSES: FEASIBILITY STUDY
Agranovski, I. E., Сафатов, А. С., Borodulin, A. I., Pyankov, O. V., Petrishchenko, V. A., An, S., Agafonov, A. P., Gm, I., Grinshpun, S. A., & Agranovski, V. (2003) · Journal of Aerosol Science · doi:10.1016/s0021-8502(03)00149-6 · Cited by 54
Assessment of Electrical Charge on Airborne Microorganisms by a New Bioaerosol Sampling Method
Lee, S.-A., Willeke, K., Mainelis, G., Adhikari, A., Wang, H., Reponen, T. A., & Grinshpun, S. A. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490424357 · Cited by 53 · cited 1×
“The learned principles were then used to develop and apply a stand-alone ESP for laboratory and field investigations of culturable microorganisms (Lee et al. 2004; Mainelis et al. 2002a; Mainelis et al. 2002b).”
MethodSelf-citationZhen, S., Li, K., Yin, L., Yao, M., Zhang, H., Chen, L., Zhou, M., & Chen, X. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2009.02.003 · Cited by 53 · cited 2×
“Particle bounce is also a potential issue in agar impactors, especially when the sampling process creates high-velocity air jets or agar desiccates due to prolonged sampling time (Zhen et al. 2009).”
BackgroundMethodComparison of quantitative airborne fungi measurements by active and passive sampling methods
Yamamoto, N., Schmechel, D., Chen, B. T., Lindsley, W. G., & Peccia, J. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.05.004 · Cited by 50 · cited 2×
“…are used in parallel to active samplers their equivalent sampling flow rate, that is, a flow rate of a sampler with 100% collection efficiency resulting in the same quantity of bioaerosols as determined by the active sampler, could be determined (Therkorn et al. 2017b; Yamamoto et al. 2011).”
BackgroundUse of gelatin filter and BioSampler in detecting airborne H5N1 nucleotides, bacteria and allergens
Wu, Y. H., Shen, F., & Yao, M. (2010) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2010.05.006 · Cited by 48 · cited 3×
“Gelatin filters or wetted porous foams could be used to reduce the effect of desiccation (Chang and Chou 2011; Chang and Hung 2012; Kenny et al. 1999; Wu, Shen, and Yao 2010; Yao and Mainelis 2007a).”
BackgroundMethodPark, J.-W., Park, C. W., Lee, S. H., & Hwang, J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125251 · Cited by 47 · cited 1×
“Park et al. (2015) also demonstrated fast bioaerosol detection by combining a novel hand-held electrostatic rod-type sampler operating at 150 L/min with a commercial luminometer (Park et al. 2015).”
MethodBioaerosol Sampling in Modern Agriculture: A Novel Approach for Emerging Pathogen Surveillance?
Anderson, B. D., Ma, M., Xia, Y., Wang, T., Shu, B., Lednicky, J. A., Ma, M., Lu, J., & Gray, G. C. (2016) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiw180 · Cited by 47 · cited 1×
“However, BioSampler showed good biological efficiency and was successfully applied to conduct surveillance for novel influenza viruses in pig barns (Anderson et al. 2016) and is often used as a reference tool when investigating other samplers for collection of viruses.”
MethodPan, M., Carol, L., Lednicky, J. A., Eiguren-Fernandez, A., Hering, S. V., Fan, Z. H., & Wu, C. (2019) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1581917 · Cited by 47 · cited 4×
“The second generation of this technology was successfully used to determine the size distribution of infectious viruses in aerosol particles (Pan et al. 2019).”
BackgroundMethodInfluentialField testing of a personal size-selective bioaerosol sampler
Kenny, L. C., Bowry, A., Crook, B., & Stancliffe, J. D. (1999) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(99)00042-3 · Cited by 46
Droogenbroeck, C. V., Risseghem, M. V., Braeckman, L., & Vanrompay, D. C. G. (2008) · Veterinary Microbiology · doi:10.1016/j.vetmic.2008.09.042 · Cited by 45 · cited 2×
“…mixed cellulose ester, polytetrafluoroethylene (Teflon, PTFE), polyvinyl chloride (PVC), nylon, gelatin, and other filter types have been used for bioaerosol sampling depending on the selected analysis technique (Burton, Grinshpun, and Reponen 2007; Li et al. 2018; Van Droogenbroeck et al. 2009).”
MethodUse of portable microbial samplers for estimating inhalation exposure to viable biological agents
Yao, M., & Mainelis, G. (2006) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500517 · Cited by 45 · cited 1×
“Due to power limitations, these impactors are single-stage collectors with d50 larger than 1 mm and high as high 8 mm; however, the use of centrifugal fans allows many of them to sample at flow rates exceeding 100 L/min and as high as 180 L/ min (Yao and Mainelis 2006).”
BackgroundSelf-citationInstrumentation Used with Microbial Bioaerosols
Jensen, P. A., Lighthart, B., Mohr, A. J., & Shaffer, B. T. (1994) · Springer eBooks · doi:10.1007/978-1-4684-6438-2_8 · Cited by 44 · cited 2×
“Several excellent references are available to help select bioaerosol sampling protocols (ACGIH 1999; Jensen et al. 1994; Reponen, Willeke, and Grinshpun 2011), but more work is needed to develop standard bioaerosol sampling and reporting guidelines, especially given rapid advances in sampling…”
BackgroundCollection of Airborne Microorganisms into Liquid by Bubbling through Porous Medium
Agranovski, I. E., Agranovski, V., Grinshpun, S. A., Reponen, T. A., & Willeke, K. (2002) · Aerosol Science and Technology · doi:10.1080/027868202753571322 · Cited by 44 · cited 4×
“One example of an alternative design uses a porous medium that is submerged into the liquid to divide the aerosol flow into multiple small air streams that create tiny bubbles and remove particles onto the sampler’s walls (Agranovski et al. 2002a; Agranovski et al. 2002b; Agranovski et al. 2005).”
BackgroundMethodInfluentialLi, Z., Xu, X., Thompson, L. A., Gross, H. E., Shenkman, E. A., DeWalt, D. A., & Huang, I. (2019) · Academic Pediatrics · doi:10.1016/j.acap.2019.03.010 · Cited by 43 · cited 1×
“Rotating arms covered with a sticky substance, also known as a Rotorod, are used to collect larger biological particles such pollen (Li et al. 2019); the captured particles are then examined under a microscope or even using PCR (Calderon et al. 2002).”
MethodHan, T., Nazarenko, Y., Lioy, P. J., & Mainelis, G. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00685.x · Cited by 41 · cited 1×
“RC close to a million could be achieved by decreasing the amount of collection liquid down to tens or even single microliters as was demonstrated in an electrostatic precipitator with the superhydrophobic surface (EPSS) (Han, An, and Mainelis 2010; Han and Mainelis 2008; Han et al. 2011).”
MethodSelf-citationThe Effect of Sampling Time on the Overall Performance of Portable Microbial Impactors
Mainelis, G., & Tabayoyong, M. (2009) · Aerosol Science and Technology · doi:10.1080/02786820903390372 · Cited by 41 · cited 1×
“Desiccation of agar due to prolonged sampling also leads to decreased culturable counts (Mainelis and Tabayoyong 2010).”
BackgroundSelf-citationDevelopment of an integrated microfluidic electrostatic sampler for bioaerosol
Ma, Z., Zheng, Y., Cheng, Y., Xie, S., Ye, X., & Yao, M. (2016) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2016.01.003 · Cited by 40 · cited 2×
“Two electrostatics-based samplers with microfluidic interfaces reported a capture efficiency of approximately 20%, leading to concentrated bioaerosol samples (Ma et al. 2016; Pardon et al. 2015).”
BackgroundViegas, C. S. B., Monteiro, A., Caetano, L. A., Faria, T., Carolino, E., & Viegas, S. (2018) · Atmosphere · doi:10.3390/atmos9020064 · Cited by 38 · cited 2×
“The effect of sampling duration on passive sample quality and representativeness remains a subject of investigation (Viegas et al. 2018a).”
BackgroundA high-flow portable biological aerosol trap (HighBioTrap) for rapid microbial detection
Chen, H., & Yao, M. (2017) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2017.11.012 · Cited by 37 · cited 2×
“Recently, a portable impactor with a sampling flow rate as high as 1200 L/ min and collection efficiency of 10–20% when capturing single bacteria has been described (Chen and Yao 2018).”
BackgroundThe Adaptation of Existing Personal Inhalable Aerosol Samplers for Bioaerosol Sampling
Kenny, L. C., Stancliffe, J. D., Crook, B., Stagg, S., Griffiths, W. D., Stewart, I. W., & Futter, S. J. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891011009 · Cited by 37 · cited 2×
“Polyurethane foams capable of maintaining microorganism viability (Kenny et al. 1998) were placed in series in front of a polycarbonate filter to sample thoracic and respirable bioaerosol fractions in the field (Kenny et al. 1999).”
MethodApplication of ATP-based bioluminescence for bioaerosol quantification: Effect of sampling method
Han, T., Wren, M., DuBois, K., Therkorn, J., & Mainelis, G. (2015) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2015.08.003 · Cited by 37 · cited 3×
“A sampler’s detection ability could be improved by increasing its Concentration Rate (RC, t 1) (Han et al. 2015b): Concentration rate, RC t 1ð Þ ¼ Particle concentration in liquid L 1ð Þ Airborne particle concentration L 1ð Þ ) Q L min v Lð Þ g, (1) where Q is sampling flowrate, g is collection…”
BackgroundSelf-citationXu, Z., & Yao, M. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.582195 · Cited by 37 · cited 10×
“Efficient capture of viruses was achieved using ESPs with a novel charging system (Hogan, Lee, and Biswas 2004; Kettleson et al. 2009), including for the use of plaque assays and qPCR.”
MethodInfluentialAsefa, D. T., Langsrud, S., Gjerde, R. O., Kure, C. F., Sidhu, M. S., Nesbakken, T., & Skaar, I. (2009) · Food Control · doi:10.1016/j.foodcont.2008.11.011 · Cited by 36 · cited 1×
“…1972; Sayer, Shean, and Ghosseiri 1969; Solomon 1975), it is still widely used in contamination sensitive industries, such as food or drug production, industries (Asefa et al. 2009) and health care facilities (Mahida et al. 2018), where exposed agar plates serve as indicators of microbial presence.”
BackgroundOptimization of a real-time PCR assay to quantitate airborne fungi collected on a gelatin filter
Yamamoto, N., Kimura, M., Matsuki, H., & Yanagisawa, Y. (2009) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2009.06.015 · Cited by 36 · cited 1×
“Gelatin filters also have been reported to have some inhibitory effect on PCR analysis (Yamamoto et al. 2010).”
BackgroundLiebers, V., van Kampen, V., Bünger, J., Düser, M., Stubel, H., Brüning, T., & Raulf, M. (2012) · Journal of Toxicology and Environmental Health · doi:10.1080/15287394.2012.674919 · Cited by 36 · cited 1×
“Electrostatic dust fall collectors (EDC) which use electrostatic cloths (Noss et al. 2008) were used to examine 2-week long exposures to endotoxin (Liebers et al. 2012).”
MethodWagner, J., & Macher, J. (2012) · Aerosol Science and Technology · doi:10.1080/02786826.2012.674232 · Cited by 35 · cited 1×
“Due to their ease of use and application of standard and even automated microscopy analysis (Wagner and Macher 2012), spore traps are widely used in indoor air quality investigations, especially where the presence of mold is a concern (Godish and Godish 2008), and they became the go-to tool of…”
BackgroundSayer, W. J., Shean, D. B., & Ghosseiri, J. (1969) · Journal of Allergy · doi:10.1016/0021-8707(69)90088-4 · Cited by 34 · cited 1×
“…air volume and often does not compare favorably against active sampling methods (Buttner and Stetzenbach 1993; Sayer, MacKnight, and Wilson 1972; Sayer, Shean, and Ghosseiri 1969; Solomon 1975), it is still widely used in contamination sensitive industries, such as food or drug production,…”
BackgroundImpact of Relative Humidity and Collection Media on Mycobacteriophage D29 Aerosol
Liu, K., Wen, Z., Li, N., Yang, W., Wang, J., Hu, L., Dong, X., Lu, J., & Li, J. (2011) · Applied and Environmental Microbiology · doi:10.1128/aem.06610-11 · Cited by 34 · cited 1×
“The collection liquid used in bioaerosol sampling typically is deionized and autoclaved water (Liu et al. 2012), NaCl solution or phosphate buffer saline (PBS) solution with or without surfactants such as Tween-20, Tween-80, Triton X-100, or an antifoaming agent (Chang, Ting, and Horng 2019; Dungan…”
MethodRoux, J.-M., Kaspari, O., Heinrich, R., Hanschmann, N., & Grunow, R. (2013) · Aerosol Science and Technology · doi:10.1080/02786826.2013.763896 · Cited by 34 · cited 1×
“Here, a personal electrostatic sampler based on ionic wind and operating at a sampling flow rate of 5 L/min was described and used to capture fungal spores on a dry collection surface (Roux et al. 2013; Roux et al. 2016); the presence of spores was determined via arabitol analysis.”
MethodA passive sampler for airborne coarse particles
Yamamoto, N., Hikono, M., Koyama, H., Kumagai, K., Fujii, M., & Yanagisawa, Y. (2006) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2006.05.002 · Cited by 34 · cited 1×
“It was designed for coarse particles (Yamamoto et al. 2006) and then successfully applied to measure exposures to pollen (Yamamoto, Matsuki, and Yanagisawa 2007).”
MethodDevelopment of a new portable air sampler based on electrostatic precipitation
Roux, J.-M., Sarda‐Estève, R., Delapierre, G., Nadal, M.-H., Bossuet, C., & Olmedo, L. (2015) · Environmental Science and Pollution Research · doi:10.1007/s11356-015-5522-3 · Cited by 32
Enzyme-linked immunosorbent assay for the detection of airborne microorganisms used in biotechnology
Speight, S., Hallis, B., Bennett, A., & Benbough, J. E. (1997) · Journal of Aerosol Science · doi:10.1016/s0021-8502(96)00449-1 · Cited by 32 · cited 2×
“2008) and leave out viable but not culturable microorganisms (VNBC), and non-viable microorganisms which could still cause health effects (Robbins et al. 2000; Speight et al. 1997).”
BackgroundSayer, W. J., MacKnight, N. M., & Wilson, H. W. (1972) · American Journal of Clinical Pathology · doi:10.1093/ajcp/58.5.558 · Cited by 31 · cited 1×
“…due to the indeterminate air volume and often does not compare favorably against active sampling methods (Buttner and Stetzenbach 1993; Sayer, MacKnight, and Wilson 1972; Sayer, Shean, and Ghosseiri 1969; Solomon 1975), it is still widely used in contamination sensitive industries,…”
BackgroundKilburg-Basnyat, B. J., Metwali, N., & Thorne, P. S. (2014) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meu063 · Cited by 31
Field performance of a novel passive bioaerosol sampler using polarized ferroelectric polymer films
Therkorn, J., Thomas, N. M., Scheinbeim, J. I., & Mainelis, G. (2017) · Aerosol Science and Technology · doi:10.1080/02786826.2017.1316830 · Cited by 31 · cited 5×
“However, elution efficiencies of 80% or higher can be achieved with properly designed elution protocols (Therkorn et al. 2017b; Wang et al. 2001).”
BackgroundInfluentialSelf-citationZhen, H., Krumins, V., Fennell, D. E., & Mainelis, G. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.10.154 · Cited by 31 · cited 3×
“Laboratory and field experiments showed that the filter-based Button Aerosol Sampler and the liquidbased BioSampler yield different microbial communities (Zhen et al. 2018).”
BackgroundMethodSelf-citationGeneration and sampling of nanoscale infectious viral aerosols
Walls, H. J., Ensor, D., Harvey, L. A., Kim, J., Chartier, R., Hering, S. V., Spielman, S., & Lewis, G. S. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1191617 · Cited by 31 · cited 2×
“However, the collection of viral aerosols is challenging, and researchers only recently began to investigate the infectivity of viral bioaerosols in the nanoparticle size range (Walls et al. 2016).”
BackgroundMethodChang, C., & Hung, P.-Y. (2012) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2012.02.003 · Cited by 30 · cited 4×
“Gelatin filters or wetted porous foams could be used to reduce the effect of desiccation (Chang and Chou 2011; Chang and Hung 2012; Kenny et al. 1999; Wu, Shen, and Yao 2010; Yao and Mainelis 2007a).”
BackgroundMethodInfluentialPERFORMANCE OF BIOAEROSOL SAMPLERS USED BY THE UK BIOTECHNOLOGY INDUSTRY
Griffiths, W. D., & Stewart, I. W. (1999) · Journal of Aerosol Science · doi:10.1016/s0021-8502(98)00783-6 · Cited by 30 · cited 3×
“The primary goal of any bioaerosol sampling device is to extract a representative bioaerosol sample from an air environment being investigated and then preserve bioaerosol sample properties needed for sample analysis by traditional and modern analysis techniques (Griffiths and Stewart 1999).”
BackgroundMethodChang, C., & Chou, F.-C. (2010) · Aerosol Science and Technology · doi:10.1080/02786826.2010.537400 · Cited by 29 · cited 2×
“Gelatin filters or wetted porous foams could be used to reduce the effect of desiccation (Chang and Chou 2011; Chang and Hung 2012; Kenny et al. 1999; Wu, Shen, and Yao 2010; Yao and Mainelis 2007a).”
BackgroundSampling of High Amounts of Bioaerosols Using a High-Volume Electrostatic Field Sampler
Madsen, A. M., & Sharma, A. K. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men004 · Cited by 29 · cited 1×
“An ESP designed to operate at 3,500 L/min was used to collect dust to be analyzed for the presence of mold spores, bacteria, endotoxin, and actinomycetes (Madsen and Sharma 2008).”
MethodViegas, C. S. B., Monteiro, A., dos Santos, M., Faria, T., Caetano, L. A., Carolino, E., Gomes, A. Q., Marchand, G., Lacombe, N., & Viegas, S. (2018) · Environmental Research · doi:10.1016/j.envres.2018.03.032 · Cited by 29 · cited 2×
“The effect of sampling duration on passive sample quality and representativeness remains a subject of investigation (Viegas et al. 2018a).”
BackgroundWhy Does Rain Increase the Concentrations of Environmental Bioaerosols during Monsoon?
Kang, S. M., Heo, K. J., & Lee, B. U. (2015) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2014.12.0328 · Cited by 28 · cited 1×
“Here, rain (Kang, Heo, and Lee 2015), accumulated snow (Amato et al. 2007) and hailstones (Mandrioli et al. 1973; Temkiv et al. 2012) have been used to investigate the presence of microorganisms and their temporal signatures.”
Kilburg-Basnyat, B. J., Metwali, N., & Thorne, P. S. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1078468 · Cited by 27
Han, T., Thomas, N. M., & Mainelis, G. (2017) · Aerosol Science and Technology · doi:10.1080/02786826.2017.1329516 · Cited by 27 · cited 3×
“…a battery-operated self-contained personal electrostatic bioaerosol sampler (PEBS) capable of operating up to 4 h at 10 L/min on a single battery charge; in the PEBS, airborne particles are deposited onto a stainless steel plate and then removed for analysis (Han, Thomas, and Mainelis 2017; 2018).”
BackgroundMethodSelf-citationA new method for collecting airborne allergens
Parvaneh, S., Ahlf, E., Elfman, L. H. M., van Hage, M., Elfman, L., & Nybom, R. (2000) · Allergy · doi:10.1034/j.1398-9995.2000.00652.x · Cited by 26 · cited 1×
“A negative ionizer equipped with a positively charged collection cup was successfully used to capture airborne cat allergens in more than 80 homes and daycare centers (Parvaneh et al. 2000).”
MethodA Temperature-Controlled AGI-30 Impinger for Sampling of Bioaerosols
Springorum, A., Clauß, M., & Hartung, J. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.588275 · Cited by 25 · cited 1×
“Temperature-controlled sampling with impingers also was shown to mitigate particle bounce (Springorum, Clauß, and Hartung 2011).”
BackgroundRahav, E., Belkin, N., Paytan, A., & Herut, B. (2019) · Atmosphere · doi:10.3390/atmos10050280 · Cited by 25 · cited 1×
“The losses could also be minimized by using polyethersulfone (PES) membrane filter, such as SuporVR , as it dissolves in a buffer eliminating the elution step which is convenient to use with molecular techniques (Rahav et al. 2019; Zhen et al. 2018).”
MethodTseng, C., Hsiao, P.-K., Chang, K., Chen, W., Yiin, .-M., & Hsieh, C. (2014) · Aerosol Science and Technology · doi:10.1080/02786826.2014.985780 · Cited by 25 · cited 1×
“Overall, the BioSampler was found to cause lower microorganism stress (Tseng et al. 2014) compared to traditional impingers and has become a de facto reference sampler in bioaerosol studies.”
BackgroundCollection efficiency of liquid‐based samplers for fungi in indoor air
Chang, C., Ting, Y., & Horng, Y. (2019) · Indoor Air · doi:10.1111/ina.12535 · Cited by 24 · cited 3×
“…used in bioaerosol sampling typically is deionized and autoclaved water (Liu et al. 2012), NaCl solution or phosphate buffer saline (PBS) solution with or without surfactants such as Tween-20, Tween-80, Triton X-100, or an antifoaming agent (Chang, Ting, and Horng 2019; Dungan and Leytem 2016).”
BackgroundMethodResultIntegration of high volume portable aerosol-to-hydrosol sampling and qPCR in monitoring bioaerosols
He, Q.-S., & Yao, M. (2011) · Journal of Environmental Monitoring · doi:10.1039/c0em00559b · Cited by 24 · cited 1×
“Mineral oil was shown to be compatible with qPCR when it was loaded into RCS High Flow centrifugal sampler (He and Yao 2011).”
MethodHan, T., Zhen, H., Fennell, D. E., & Mainelis, G. (2015) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2015.04.0206 · Cited by 24 · cited 3×
“A sampler’s detection ability could be improved by increasing its Concentration Rate (RC, t 1) (Han et al. 2015b): Concentration rate, RC t 1ð Þ ¼ Particle concentration in liquid L 1ð Þ Airborne particle concentration L 1ð Þ ) Q L min v Lð Þ g, (1) where Q is sampling flowrate, g is collection…”
BackgroundSelf-citationA simple novel device for air sampling by electrokinetic capture
Gordon, J., Gandhi, P., Shekhawat, G. S., Frazier, A., Hampton‐Marcell, J., & Gilbert, J. A. (2015) · Microbiome · doi:10.1186/s40168-015-0141-2 · Cited by 22 · cited 1×
“A sampler based on the ionic wind principle had an equivalent sampling flow rate of 113 L/min and was used to analyze the diversity of bacteria and fungi (Gordon et al. 2015).”
MethodCharacterization of a Microscale Cascade Impactor
Kang, J. S., Lee, K. S., Lee, K. H., Sung, H. J., & Kim, S. S. (2012) · Aerosol Science and Technology · doi:10.1080/02786826.2012.685115 · Cited by 22 · cited 1×
“A spin-coating by silicon oil reduced bounce in a microscale cascade impactor (Kang et al. 2012).”
BackgroundSu, W., Tolchinsky, A. D., Chen, B. T., Иванович, С. В., & Cheng, Y. S. (2012) · Journal of Environmental Monitoring · doi:10.1039/c2em30299c · Cited by 21 · cited 2×
“Thus, the performance evaluation of new and existing bioaerosol samplers should include wind tunnel or similar tests at different air velocities (Su et al. 2012b) and directions (Su et al. 2012a).”
BackgroundMethodCollection characteristics of a batch-type wetted wall bioaerosol sampling cyclone
King, M. D., Thien, B. F., Tiirikainen, S., & McFarland, A. R. (2009) · Aerobiologia · doi:10.1007/s10453-009-9129-3 · Cited by 21 · cited 1×
“This sampler concept can also operate in a batch mode, where it samples bioaerosols at 400L/min into 12mL of collection liquid (King et al. 2009).”
BackgroundField Evaluation of a Personal, Bioaerosol Cyclone Sampler
Macher, J. M., Chen, B. T., & Rao, C. Y. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802400159 · Cited by 19 · cited 1×
“Researchers from the National Institute for Occupational Safety and Health (NIOSH) recently developed and successfully used in the field a microcentrifuge-tube cyclone (Lindsley, Schmechel, and Chen 2006; Macher, Chen, and Rao 2008; Su et al. 2012b).”
MethodDesign and development of a passive bioaerosol sampler using polarized ferroelectric polymer film
Therkorn, J., Myers, N. T., Calderon, L., Scheinbeim, J. I., & Mainelis, G. (2016) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2016.12.002 · Cited by 19
Self-citationCar cabin filters as sampling devices to study bioaerosols using eDNA and microbiological methods
Hurley, K. V., Wharton, L., Wheeler, M., Skjøth, C. A., Niles, C., & Hanson, M. (2019) · Aerobiologia · doi:10.1007/s10453-018-09554-y · Cited by 19 · cited 1×
“…Ventilation and Air Conditioning (HVAC) systems are used to analyze bioaerosol presence indoors (Farnsworth et al. 2006; Hoisington et al. 2014; Maestre et al. 2018) and car filters are used to investigate bioaerosol bioburden in mobile environments (Hurley et al. 2019; Viegas et al. 2018b).”
BackgroundHunter, D. M., Leskinen, S. D., Magaña, S., Schlemmer, S. M., & Lim, D. V. (2011) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2011.09.010 · Cited by 17
Spring, A. M., Docherty, K. M., Domingue, K. D., Kerber, T. V., Mooney, M. M., & Lemmer, K. M. (2018) · Air Soil and Water Research · doi:10.1177/1178622118788871 · Cited by 17 · cited 2×
“Thus, samplers needed to meet those challenges will have to be lightweight to be fitted onto drones or balloons (Spring et al. 2018) yet capable of concentrating bioaerosol samples for reliable detection.”
BackgroundHan, T., Thomas, N. M., & Mainelis, G. (2018) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2018.07.004 · Cited by 16 · cited 16×
“Collection efficiency of G-II for influenza virus was reportedly similar to that of BioSampler.”
BackgroundMethodInfluentialSelf-citationEfficiency of Airborne Sample Analysis Platform (ASAP) bioaerosol sampler for pathogen detection
Sharma, A., Clark, E., McGlothlin, J. D., & Mittal, S. K. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2015.00512 · Cited by 13 · cited 2×
“The successful capture of bovine adenovirus serotype 3 virus on polyurethane foam (PUF) within the Airborne Sample Analysis Platform (ASAP) 2800 (Thermo Scientific, USA) at laboratory conditions was reported (Sharma et al. 2015).”
BackgroundSimon, X., Bau, S., Boivin, A., Duquenne, P., Witschger, O., & Görner, P. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1166173 · Cited by 13 · cited 5×
“approximately every 30min during long-term sampling; however, it could be used with non-evaporative fluid extending its sampling time to 8 h (Simon et al. 2016).”
BackgroundInfluentialWubulihairen, M., Lü, X., Lee, P. K. H., & Ning, Z. (2015) · Atmospheric Pollution Research · doi:10.5094/apr.2015.062 · Cited by 13 · cited 14×
“Collection efficiency of G-II for influenza virus was reportedly similar to that of BioSampler.”
InfluentialRecovery of culturableEscherichia coliO157:H7 during operation of a liquid-based bioaerosol sampler
Dungan, R. S., & Leytem, A. B. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1126666 · Cited by 11
Effect of Agar Plate Volume on Accuracy of Culturable Bioaerosol Impactors
Therkorn, J., & Mainelis, G. (2013) · Aerosol Science and Technology · doi:10.1080/02786826.2013.842954 · Cited by 11 · cited 1×
“Since the amount of agar affects the jet-to-plate distance and the strength of air jets when they reach the agar plate, the agar amount was found to affect sampler performance (Therkorn and Mainelis 2013).”
BackgroundSelf-citationJang, J., Hendriksen, N. B., Jakobsen, H. H., & Gosewinkel, U. (2018) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2018.10.012 · Cited by 6 · cited 2×
“The coupling of this device with a Cytosense flow cytometer enabled more sensitive detection of bacteria compared to qPCR (Jang et al. 2018).”
BackgroundMethodSpring, A. M., Docherty, K. M., Domingue, K. D., Kerber, T. V., Mooney, M. M., & Lemmer, K. M. (2018) · Sage Journals Data · doi:10.25384/sage.c.4183172 · Cited by 5
A wind tunnel test of newly developed personal bioaerosol samplers
Su, W., Tolchinsky, A. D., Иванович, С. В., & Cheng, Y. S. (2012) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2012.681422 · Cited by 4 · cited 3×
“Thus, the performance evaluation of new and existing bioaerosol samplers should include wind tunnel or similar tests at different air velocities (Su et al. 2012b) and directions (Su et al. 2012a).”
BackgroundMethod
Metadata
- Authors
- Mainelis, G.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2019-10-04
- Volume
- 54
- Issue
- 5
- Pages
- 496-519
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2976992378
- Cited by
- 229
- References
- 170
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.