The development and modelling of devices and paradigms for transcranial magnetic stimulation
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Magnetic stimulation is a non-invasive neurostimulation technique that can evoke action potentials and modulate neural circuits through induced electric fields. Biophysical models of magnetic stimulation have become a major driver for technological developments and the understanding of the mechanisms of magnetic neurostimulation and neuromodulation. Major technological developments involve stimulation coils with different spatial characteristics and pulse sources to control the pulse waveform. While early technological developments were the result of manual design and invention processes, there is a trend in both stimulation coil and pulse source design to mathematically optimize parameters with the help of computational models. To date, macroscopically highly realistic spatial models of the brain, as well as peripheral targets, and user-friendly software packages enable researchers and practitioners to simulate the treatment-specific and induced electric field distribution in the brains of individual subjects and patients. Neuron models further introduce the microscopic level of neural activation to understand the influence of activation dynamics in response to different pulse shapes. A number of models that were designed for online calibration to extract otherwise covert information and biomarkers from the neural system recently form a third branch of modelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple model of spiking neurons
Izhikevich, E. M. (2003) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2003.820440 · Cited by 4,828
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Babyak, M. A. (2004) · Psychosomatic Medicine · doi:10.1097/01.psy.0000127692.23278.a9 · Cited by 2,061
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Action potential generation requires a high sodium channel density in the axon initial segment
Kole, M. H. P., Ilschner, S. U., Kampa, B. M., Williams, S. R., Ruben, P. C., & Stuart, G. J. (2008) · Nature Neuroscience · doi:10.1038/nn2040 · Cited by 703
Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492 · cited 1×
“…to supra-threshold electrical stimulation, the TMS induced electric field may exclusively activate axons, as was identified, e.g. by the neural time constant (Corthout, Barker, & Cowey, 2001; D’Ostilio et al., 2016; Nowak & Bullier, 1998a, 1998b; Peterchev, Goetz, Westin, Luber, & Lisanby, 2013).”
BackgroundSignal processing in the axon initial segment
Kole, M. H. P., & Stuart, G. J. (2012) · Neuron · doi:10.1016/j.neuron.2012.01.007 · Cited by 463 · cited 1×
“More complicated patterns of local accumulations that may affect excitability to TMS stimuli such as ion channel rafts have not been studied yet (Freeman, Desmazi eres, Fricker, Lubetzki, & Sol-Foulon, 2016; Kole & Stuart, 2012; Rasband & Peles, 2016; Vacher & Trimmer, 2012).”
BackgroundThe Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · cited 1×
“These deviations are also known in electrical stimulation (Bennie, Petrofsky, Nisperos, Tsurudome, & Laymon, 2002; Buetikofer & Lawrence, 1978, 1979; Dean & Lawrence, 1985; Gorman & Mortimer, 1983; Grill & Mortimer, 1995; Wongsarnpigoon, Woock, & Grill, 2010).”
Coil design considerations for deep transcranial magnetic stimulation
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.11.038 · Cited by 308
Self-citationThe role of the coil click in TMS assessed with simultaneous EEG
Nikouline, V., Ruohonen, J., & Ilmoniemi, R. J. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00070-x · Cited by 269
Mechanisms influencing stimulus-response properties of the human corticospinal system
Boroojerdi, B., Battaglia, F., Muellbacher, W., & Cohen, L. G. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00523-5 · Cited by 256
Transcranial magnetic brain stimulation: Therapeutic promises and scientific gaps
Wassermann, E. M., & Zimmermann, T. (2012) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2011.09.003 · Cited by 243 · cited 1×
“The technique is unmatched in several applications, ranging from experimental neuroscience to medical diagnosis and therapy (Aleman, 2013; Eldaief, Press, & Pascual-Leone, 2013; Wassermann & Zimmermann, 2012).”
MethodSelective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222 · cited 1×
“It is known to show deviations, e.g. when the pulse shape is substantially varied, for short pulses, and for double pulses, as well as polyphasic pulses (Fang & Mortimer, 1991; Maccabee et al., 1998; Moffitt, McIntyre, & Grill, 2004).”
BackgroundDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216 · cited 2×
“Each shell is considered as homogeneous with a dielectric property of the tissue it represents (AlMutawaly & Findlay, 1998; Deng et al., 2008, 2011, 2013; Miranda, Lomarev, & Hallett, 2006; Ravazzani, Ruohonen, Grandori, & Tognola, 1996).”
BackgroundMethodSelf-citationThe physiology of the axon initial segment
Bender, K. J., & Trussell, L. O. (2012) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-062111-150339 · Cited by 214
The Nodes of Ranvier: Molecular Assembly and Maintenance
Rasband, M. N., & Peles, E. (2016) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a020495 · Cited by 190 · cited 1×
“More complicated patterns of local accumulations that may affect excitability to TMS stimuli such as ion channel rafts have not been studied yet (Freeman, Desmazi eres, Fricker, Lubetzki, & Sol-Foulon, 2016; Kole & Stuart, 2012; Rasband & Peles, 2016; Vacher & Trimmer, 2012).”
BackgroundMachine learning as an experimental science
Langley, P. (1988) · Machine Learning · doi:10.1007/bf00115008 · Cited by 187
Energy-efficient waveform shapes for neural stimulation revealed with a genetic algorithm
Wongsarnpigoon, A., & Grill, W. M. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046009 · Cited by 166 · cited 1×
“Similar approaches are in progress for transcutaneous and invasive electrical stimulation (Jezernik, Sinkjaer, & Morari, 2010; Wongsarnpigoon & Warren, 2010; Wongsarnpigoon et al., 2010).”
Gugino, L. D., Rafael Romero, J., Aglio, L., Titone, D., Ramirez, M., Pascual-Leone, A., Grimson, E., Weisenfeld, N., Kikinis, R., & Shenton, M.-E. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00633-2 · Cited by 140
Efficiency Analysis of Waveform Shape for Electrical Excitation of Nerve Fibers
Wongsarnpigoon, A., Woock, J. P., & Grill, W. M. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047610 · Cited by 104 · cited 1×
“Similar approaches are in progress for transcutaneous and invasive electrical stimulation (Jezernik, Sinkjaer, & Morari, 2010; Wongsarnpigoon & Warren, 2010; Wongsarnpigoon et al., 2010).”
Numerical analysis and design of single-source multicoil TMS for deep and focused brain stimulation
Gomez, L., Cajko, F., Hernandez-Garcia, L., Grbic, A., & Michielssen, E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264632 · Cited by 55
Effects of frequency-dependent membrane capacitance on neural excitability
Howell, B., Medina, L. E., & Grill, W. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056015 · Cited by 39
Cited by
Lefaucheur, J.-P., Aleman, A., Baeken, C., Benninger, D. H., Brunelin, J., Di Lazzaro, V., Filipović, S. R., Grefkes, C., Hasan, A., Hummel, F. C., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.002 · Cited by 2,382
Clinical utility and prospective of TMS–EEG
Tremblay, S., Rogasch, N. C., Premoli, I., Blumberger, D. M., Casarotto, S., Chen, R., Di Lazzaro, V., Farzan, F., Ferrarelli, F., Fitzgerald, P. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.01.001 · Cited by 472
Basu, I., Robertson, M. M., Crocker, B., Peled, N., Farnes, K., Vallejo-Lopez, D. I., Deng, H., Thombs, M., Martinez-Rubio, C., Cheng, J. J., et al. (2019) · Brain Stimulation · doi:10.1016/j.brs.2019.03.007 · Cited by 50
Metadata
- Authors
- Goetz, S. M., & Deng, Z.-D.
- Venue
- International Review of Psychiatry
- Publisher
- Informa UK Limited
- Published
- 2017-03-04
- Volume
- 29
- Issue
- 2
- Pages
- 115-145
- ISSN
- 0954-0261 (ISSN-L)
- 1369-1627
- OpenAlex
- W2609116476
- Cited by
- 90
- References
- 22
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.