On the relation between uncertainties of weighted frequency averages and the various types of Allan deviations
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The power spectral density in the Fourier frequency domain, and the different variants of the Allan deviation (ADEV) in dependence on the averaging time are well established tools to analyse the fluctuation properties and frequency instability of an oscillatory signal. It is often supposed that the statistical uncertainty of a measured average frequency is given by the ADEV at a well-considered averaging time. However, this approach requires further mathematical justification and refinement, which has already been done regarding the original ADEV for certain noise types. Here we provide the necessary background to use the modified Allan deviation (modADEV) and other two-sample deviations to determine the uncertainty of weighted frequency averages. The type of two-sample deviation used to determine the uncertainty depends on the method used for determination of the average. We find that the modADEV, which is connected with -weighted averaging, and the two-sample deviation associated with a linear phase regression weighting (parADEV) are, in particular, advantageous for measurements in which white phase noise is dominating. Furthermore, we derive a procedure for how to minimise the uncertainty of a measurement for a typical combination of white phase and frequency noise by adaptive averaging of the data set with different weighting functions. Finally, some aspects of the theoretical considerations for real-world frequency measurement equipment are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Optical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Raupach, S. M. F., Koczwara, A., & Grosche, G. (2015) · Physical Review A · doi:10.1103/physreva.92.021801 · Cited by 101
Research works printed but not linked: 17
- 10.1109/TIM.1987.6312761 · DOI · Paper page
- 10.1109/TIM.1971.5570702 · DOI · Paper page
- 10.1109/TIM.1984.4315235 · DOI
- 10.1063/1.1898203 · DOI · Paper page
- 10.1109/TUFFC.2007.337 · DOI · Paper page
- Lee W-K, 2010, Metrologia, 47, 24, 10.1088/0026-1394/47/1/004 · DOI
- Allan D W, 1981, Proc. of the 35th Ann. Frequency Control Symp., 470
- 10.1364/OE.22.026537 · DOI · Paper page
- Bauch A, 2006, Metrologia, 43, 109, 10.1088/0026-1394/43/1/016 · DOI · Paper page
- 10.1109/FREQ.2005.1574007 · doi:10.1109/freq.2005.1574007
- 10.1109/FCS.2015.7138854 · doi:10.1109/fcs.2015.7138854
- 10.1140/epjst/e2009-01047-1 · doi:10.1140/epjst/e2009-01047-1
- Kalisz J, 2004, Metrologia, 41, 17, 10.1088/0026-1394/41/1/004 · doi:10.1088/0026-1394/41/1/004
- 10.1109/FREQ.2001.956178 · DOI
- 10.1049/cp:20040935 · DOI
- Schäfer W, 1999, 31st Annual Precise Time and Time Interval Meeting
- Sesia I, 2008, Metrologia, 45, S134, 10.1088/0026-1394/45/6/S19 · DOI
Cited by
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
“High suppression of phase noise as present in the fiber link can be achieved by appropriate weighting functions for averaging the frequency data recorded by the dead-time-free counters (29).”
BackgroundSelf-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Self-citationSchioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118
Self-citationRaupach, S. M. F., Koczwara, A., & Grosche, G. (2015) · Physical Review A · doi:10.1103/physreva.92.021801 · Cited by 101
Metadata
- Authors
- Benkler, E., Lisdat, C., & Sterr, U.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2015-07-17
- Volume
- 52
- Issue
- 4
- Pages
- 565-574
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2150292229
- Cited by
- 69
- References
- 5
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Funders
- European Union and EURAMET (EMRP EXL01 (QESOCAS), EMRP SIB55 (ITOC))
- Deutsche Forschungsgemeinschaft (RTG 1729, SFB 1128)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the relation between uncertainties of weighted frequency averages and the various types of Allan deviations. https://app.cochat.ai/papers/10.1088/0026-1394/52/4/565
- The paper
- Benkler, E., Lisdat, C., & Sterr, U. (2015). On the relation between uncertainties of weighted frequency averages and the various types of Allan deviations. Metrologia. https://doi.org/10.1088/0026-1394/52/4/565
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.