Measurement of the optical properties of the skull in the wavelength range 650-950 nm
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The optical properties of samples of bone from pig skull have been measured over the wavelength range 650-950 nm. The scattering phase function was measured on thin samples of the bone using a goniometer, and a value for the mean cosine g, of the scattering angle, was calculated. The scattering and absorption coefficients, mu s and mu a were then determined from measurements of diffuse reflectance and transmittance made with a pair of integrating spheres, by a step-wise search through a table of diffuse reflectance and transmittance versus mu a and mu s generated by a Monte Carlo model incorporating the measured scattering phase function. Values for g measured on six samples varied from 0.925 +/- 0.014 at 650 nm to 0.945 +/- 0.013 at 950 nm. Corresponding values for mu a and mu s measured on 18 samples were mu a = 0.04 +/- 0.002 mm-1, mu s = 35 +/- 0.7 mm-1 at 650 nm to mu a = 0.05 +/- 0.002 mm-1, mu s = 24 +/- 0.6 mm-1 at 950 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Self-citationWyatt, J. S., Delpy, D. T., Cope, M., Wray, S., & Reynolds, E. O. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90467-8 · Cited by 876
Self-citationVan Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. M. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
van der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Self-citationSevick, E. M., Chance, B., Leigh, J., Nioka, S., & Maris, M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90339-u · Cited by 360
Noninvasive Monitoring of Cerebral Oxygenation in Preterm Infants: Preliminary Observations
Brazy, J. E., Lewis, D. V., Mitnick, M. H., & vander Vliet, F. F. J. (1985) · Pediatrics · doi:10.1542/peds.75.2.217 · Cited by 356
Measurement of Optical Path Length for Cerebral Near-Infrared Spectroscopy in Newborn Infants
Wyatt, J. S., Cope, M., Delpy, D. T., van der Zee, P., Arridge, S., Edwards, A. D., & Reynolds, E. O. R. (1990) · Developmental Neuroscience · doi:10.1159/000111843 · Cited by 182
Self-citationThe composition of body tissues. (II) Fetus to young adult
White, D. R., Widdowson, E. M., Woodard, H. Q., & Dickerson, J. W. T. (1991) · The British Journal of Radiology · doi:10.1259/0007-1285-64-758-149 · Cited by 128
Reconstruction methods for infrared absorption imaging
Arridge, S., van der Zee, P., Cope, M., & Delpy, D. T. (1991) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.44191 · Cited by 110
Self-citation
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
The physics, biophysics and technology of photodynamic therapy
Wilson, B. C., & Patterson, M. S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/9/r01 · Cited by 1,006
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Brain Photobiomodulation Therapy: a Narrative Review
Salehpour, F., Mahmoudi, J., Kamari, F., Sadigh-Eteghad, S., Rasta, S. H., & Hamblin, M. R. (2018) · Molecular Neurobiology · doi:10.1007/s12035-017-0852-4 · Cited by 517
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Self-citationAlexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/021 · Cited by 465
In vivo local determination of tissue optical properties: applications to human brain
Bevilacqua, F., Piguet, D., Marquet, P., Gross, J. D., Tromberg, B. J., & Depeursinge, C. (1999) · Applied Optics · doi:10.1364/ao.38.004939 · Cited by 456
Corrigendum: Optical properties of biological tissues: a review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/14/5007 · Cited by 430
Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/011 · Cited by 374
Self-citationOkada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002915 · Cited by 364
Self-citationHielscher, A. H., Alcouffe, R. E., & Barbour, R. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/5/017 · Cited by 332
Fukui, Y., Ajichi, Y., & Okada, E. (2003) · Applied Optics · doi:10.1364/ao.42.002881 · Cited by 286
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002906 · Cited by 274
Self-citationOhmae, E., Ouchi, Y., Oda, M., Suzuki, T., Nobesawa, S., Kanno, T., Yoshikawa, E., Futatsubashi, M., Ueda, Y., Okada, H., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.008 · Cited by 224
Golovynskyi, S., Golovynska, I., Stepanova, L. I., Datsenko, O. I., Liu, L., Qu, J., & Ohulchanskyy, T. Y. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201800141 · Cited by 209
Choi, J., Wolf, M., Toronov, V., Wolf, U., Polzonetti, C., Hueber, D., Safonova, L. P., Gupta, R., Michalos, A., Mantulin, W., et al. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1628242 · Cited by 204
Firbank, M., Okada, E., & Delpy, D. T. (1998) · NeuroImage · doi:10.1006/nimg.1998.0348 · Cited by 172
“The optical properties are typical of those quoted in the literature (Firbank et al., 1993; van der Zee et al., 1993; Cheong, 1995) at 800 nm. Oxygenated and deoxygenated hemoglobin have an isobestic point at 798 nm, with an absorption coefficient of 0.2 mm Ϫ1 mM (Matcher et al., 1995).”
InfluentialSelf-citationInfluence of glucose concentration on light scattering in tissue-simulating phantoms
Kohl, M., Essenpreis, M., Böcker, D., & Cope, M. (1994) · Optics Letters · doi:10.1364/ol.19.002170 · Cited by 158
Self-citationSurface Enhanced Spatially Offset Raman Spectroscopy Detection of Neurochemicals Through the Skull
Moody, A. S., Baghernejad, P. C., Webb, K. R., & Sharma, B. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00985 · Cited by 56
Pulsatile and steady-state hemodynamics of the human patella bone by diffuse optical spectroscopy
Farzam, P., Zirak, P., Binzoni, T., & Durduran, T. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/839 · Cited by 28
Metadata
- Authors
- Firbank, M., Hiraoka, M., Essenpreis, M., & Delpy, D. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1993-04-01
- Volume
- 38
- Issue
- 4
- Pages
- 503-510
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2048686272
- Cited by
- 305
- References
- 14
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.