Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Items 901–1,000 of 1,000
Structure-adaptive CBCT reconstruction using weighted total variation and Hessian penalties
Shi, Q., Sun, N., Sun, T., Wang, J., & Tan, S. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003299 · Cited by 9
Magome, T., Haga, A., Takahashi, Y., Nakagawa, K., Dusenbery, K. E., & Hui, S. K. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2016.06.2458 · Cited by 8
A fast 4D cone beam CT reconstruction method based on the OSC-TV algorithm
Mascolo‐Fortin, J., Matenine, D., Archambault, L., & Després, P. (2018) · Journal of X-Ray Science and Technology · doi:10.3233/xst-17289 · Cited by 8
Block‐matching sparsity regularization‐based image reconstruction for low‐dose computed tomography
Cai, A., Li, L., Zheng, Z., Wang, L., & Yan, B. (2018) · Medical Physics · doi:10.1002/mp.12911 · Cited by 9
Comparison of three undersampling approaches in computed tomography reconstruction
Shen, C., Lou, Y., Chen, L., Zeng, T., Ng, M. K., Zhu, L., & Jia, X. (2019) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2019.07.07 · Cited by 8
Dao-Ngoc, L., & Du, Y. (2019) · Electronics · doi:10.3390/electronics8121381 · Cited by 8
A signal detection model for quantifying overregularization in nonlinear image reconstruction
Sidky, E. Y., Phillips, J. P., Zhou, W., Ongie, G., Bastida, J. P. C., Reiser, I., Anastasio, M. A., & Pan, X. (2021) · Medical Physics · doi:10.1002/mp.14703 · Cited by 8
Self-citationDynamic compressed sensing for real-time tomographic reconstruction
Schwartz, J., Zheng, H., Hanwell, M. D., Jiang, Y., & Hovden, R. (2020) · Ultramicroscopy · doi:10.1016/j.ultramic.2020.113122 · Cited by 8
Computed tomography with view angle estimation using uncertainty quantification
Riis, N. A. B., Dong, Y., & Hansen, P. C. (2021) · Inverse Problems · doi:10.1088/1361-6420/abf5ba · Cited by 8
Dictionary‐learning‐based reconstruction method for electron tomography
Liu, B., Yu, H., Verbridge, S. S., Sun, L., & Wang, G. (2013) · Scanning · doi:10.1002/sca.21127 · Cited by 8
Research on ADMM Reconstruction Algorithm of Photoacoustic Tomography With Limited Sampling Data
Wang, Z., Hao-quan, W., & Ren, S. (2021) · IEEE Access · doi:10.1109/access.2021.3104154 · Cited by 8
Deep learning based image reconstruction for sparse-view diffuse optical tomography
Jalalimanesh, M. H., & Ansari, M. A. (2021) · Waves in Random and Complex Media · doi:10.1080/17455030.2021.1968540 · Cited by 8
Luo, Y., Spronk, D., Lee, Y. Z., Zhou, O. Z., & Lü, J. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.5.052114 · Cited by 8
Magdalena, R., Rahim, T., Pratama, I. P. A. E., Novamizanti, L., Ramatryana, I. N. A., Raja, A. Y., & Shin, S. Y. (2021) · IEEE Access · doi:10.1109/access.2021.3124239 · Cited by 8
An Adversarial Learning Based Approach for 2D Unknown View Tomography
Zehni, M., & Zhao, Z. (2022) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2022.3197939 · Cited by 9
Sparse-View Cone-Beam CT Reconstruction by Bar-by-Bar Neural FDK Algorithm
Wang, S., Yatagawa, T., Ohtake, Y., & Suzuki, H. (2023) · Nondestructive Testing And Evaluation · doi:10.1080/10589759.2023.2195646 · Cited by 8
System matrix analysis for sparse-view iterative image reconstruction in X-ray CT
Wang, L., Zhang, H., Cai, A., Yong-l, L., Yan, B., Li, L., & Hu, G. (2015) · Journal of X-Ray Science and Technology · doi:10.3233/xst-140465 · Cited by 8
Laloum, D., Printemps, T., Sánchez, D. F., Lorut, F., Audoit, G., & Bleuet, P. (2014) · Journal of Microscopy · doi:10.1111/jmi.12162 · Cited by 10
Distributed CT image reconstruction algorithm based on the alternating direction method
Wang, L., Cai, A., Zhang, H., Yan, B., Li, L., Hu, G., & Bao, S. (2015) · Journal of X-Ray Science and Technology · doi:10.3233/xst-140472 · Cited by 10
Priori mask guided image reconstruction ( p -MGIR) for ultra-low dose cone-beam computed tomography
Park, J. C., Zhang, H., Chen, Y., Fan, Q., Kahler, D. L., Liu, C., & Lü, B. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/8505 · Cited by 8
Ouyang, L., Lee, H. P., & Wang, J. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.04.015 · Cited by 8
Guan, H., Xu, Q., Garson, A. B., & Anastasio, M. A. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/n151 · Cited by 8
Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy
Bian, J., Sharp, G. C., Park, Y. K., Ouyang, J., Bortfeld, T. R., & Fakhri, G. E. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/9/3317 · Cited by 8
Shape recovery for sparse‐data tomography
Haario, H., Kallonen, A., Laine, M., Niemi, E., Purisha, Z., & Siltanen, S. (2017) · Mathematical Methods in the Applied Sciences · doi:10.1002/mma.4480 · Cited by 8
LdCT-Net: low-dose CT image reconstruction strategy driven by a deep dual network
Ma, J., He, J., Wang, Y., Yang, Y., Bian, Z., Zeng, D., Sun, J. Z., & Xu, Z. (2018) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2293536 · Cited by 8
Derivative-free superiorization with component-wise perturbations
Censor, Y., Heaton, H., & Schulte, R. W. (2018) · Numerical Algorithms · doi:10.1007/s11075-018-0524-0 · Cited by 10
Comparison Study of Regularizations in Spectral Computed Tomography Reconstruction
Salehjahromi, M., Zhang, Y., & Yu, H. (2018) · Sensing and Imaging · doi:10.1007/s11220-018-0200-4 · Cited by 8
Joint reconstruction in low dose multi-energy CT
Toivanen, J., Meaney, A., Siltanen, S., & Kolehmainen, V. (2020) · Inverse Problems and Imaging · doi:10.3934/ipi.2020028 · Cited by 8
Chen, B., & Tang, Y. (2019) · Mathematical Problems in Engineering · doi:10.1155/2019/7376263 · Cited by 8
Kaganovsky, Y., Han, S., Degirmenci, S., Politte, D. G., Brady, D. J., O’Sullivan, J. A., & Carin, L. (2015) · SIAM Journal on Imaging Sciences · doi:10.1137/141000038 · Cited by 10
Desmal, A. A., Schubert, J. R., Denker, J., Kisner, S. J., Rezaee, H., Couture, A., Miller, E. L., & Tracey, B. (2019) · IEEE Access · doi:10.1109/access.2019.2953217 · Cited by 9
Hehn, L., Gradl, R., Dierolf, M., Morgan, K. S., Paganin, D. M., & Pfeiffer, F. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2962615 · Cited by 8
Tomographic reconstruction with spatially varying parameter selection
Dong, Y., & Schönlieb, C. (2020) · Inverse Problems · doi:10.1088/1361-6420/ab72d4 · Cited by 8
Shiba, S., & Sagara, H. (2020) · Journal of Nuclear Science and Technology · doi:10.1080/00223131.2020.1854882 · Cited by 8
Jacob, M., Sorel, J., Pinhiero, R. B., Mazen, F., Grenier, A., Épicier, T., & Saghi, Z. (2021) · Semiconductor Science and Technology · doi:10.1088/1361-6641/abd925 · Cited by 8
Fu, J., Feng, F., Quan, H., Wan, Q., Chen, Z., Liu, X., Zheng, H., Liang, D., Cheng, G., & Hu, Z. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-963 · Cited by 8
Deep Learning-based Low-dose Tomography Reconstruction with Hybrid-dose Measurements
Wu, Z., Biçer, T., Liu, Z., Andrade, V. D., Zhu, Y., & Foster, I. T. (2020) · doi:10.1109/mlhpcai4s51975.2020.00017 · Cited by 12
An improved non-local means regularized iterative reconstruction method for low-dose dental CBCT
Hao, J., Zhang, L., Li, L., & Kang, K. (2012) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2012.6551780 · Cited by 8
Reconstruction From Limited-Angle Projections Based on $\delta-u$ Spectrum Analysis
Luo, J., Li, W., & Zhu, Y. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2032893 · Cited by 8
Low-Dose CT via Deep Neural NetworkPreprint
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1609.08508 · Cited by 11
Artifact suppression for sparse view CT via transformer-based generative adversarial network
Zhang, T., Liu, J., Wu, F., Wang, K., Huang, S., & Zhang, Y. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106297 · Cited by 8
Directional TV algorithm for image reconstruction from sparse-view projections in EPR imaging
Qiao, Z., Liu, P., Fang, C., Redler, G., Epel, B., & Halpern, H. J. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad4a1b · Cited by 9
Fast and detail-preserving low-dose CT denoising with diffusion model
Su, B., Dong, P., Hu, X., Wang, B., Zha, Y., Wu, Z., & Wan, J. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.107580 · Cited by 9
Dual-Domain deep prior guided sparse-view CT reconstruction with multi-scale fusion attention
Wu, J., Lin, J., Jiang, X., Zheng, W., Zhong, L., Pang, Y., Meng, H., & Li, Z. (2025) · Scientific Reports · doi:10.1038/s41598-025-02133-5 · Cited by 12
ECG-gated C-arm computed tomography using L1 regularization
Mory, C., Zhang, B., Auvray, V., Graß, M., Schäfer, D., Peyrin, F., Rit, S., Douek, P., & Boussel, L. (2012) · HAL · Cited by 8
3D Alternating Direction TV-Based Cone-Beam CT Reconstruction with Efficient GPU Implementation
Cai, A., Wang, L., Zhang, H., Yan, B., Li, L., Xi, X., Guan, M., & Li, J. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/982695 · Cited by 7
Discrete Tomography by Continuous Multilabeling Subject to Projection Constraints
Zisler, M., Petra, S., Schnörr, C., & Schnörr, C. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-45886-1_21 · Cited by 7
An efficient multi-grid method for TV minimization problems
Zhang, Z., Li, X., Duan, Y., Yin, K., & Tai, X. (2021) · Inverse Problems and Imaging · doi:10.3934/ipi.2021034 · Cited by 7
CT Image Reconstruction via Nonlocal Low-Rank Regularization and Data-Driven Tight Frame
Shen, Y., Sun, S., Feng-sheng, X., Liu, Y., Yin, X., & Zhou, X. (2021) · Symmetry · doi:10.3390/sym13101873 · Cited by 7
DR-only Carbon-ion radiotherapy treatment planning via deep learning
Zhang, X., He, P., Li, Y., Liu, X., Ma, Y., Shen, G., Dai, Z., Zhang, H., Chen, W., & Li, Q. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.06.016 · Cited by 8
One-bit compressed sensing via total variation minimization method
Zhong, Y., Xu, C., Zhang, B., Hou, J., & Wang, J. (2023) · Signal Processing · doi:10.1016/j.sigpro.2023.108939 · Cited by 7
On Krylov methods for large-scale CBCT reconstruction
Landman, M. S., Biguri, A., Hatamikia, S., Boardman, R., Aston, J., & Schönlieb, C. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/acd616 · Cited by 7
Park, J. C., Song, B., Liang, X., Lü, B., Tan, J., Parisi, A., Denbeigh, J. M., Yaddanapudi, S., Choi, B., Kim, J. S., et al. (2023) · Medical Physics · doi:10.1002/mp.16734 · Cited by 8
Li, X., Jing, K., Yang, Y., Wang, Y., Ma, J., Zheng, H., & Xu, Z. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3347258 · Cited by 9
Hierarchical decomposed dual-domain deep learning for sparse-view CT reconstruction
Han, Y. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad31c7 · Cited by 7
Reconstruction method suitable for fast CT imaging
Sun, X., Li, Y., Li, Y., Wang, S., Qin, Y., & Chen, P. (2024) · Optics Express · doi:10.1364/oe.522097 · Cited by 7
Improving Automated Hemorrhage Detection at Sparse-View CT via U-Net–based Artifact Reduction
Thalhammer, J., Schultheiß, M., Dorosti, T., Lasser, T., Pfeiffer, F., Pfeiffer, D., & Schaff, F. (2024) · Radiology Artificial Intelligence · doi:10.1148/ryai.230275 · Cited by 9
Deep Learning for Spectroscopic X‐ray Nano‐Imaging Denoising
Fu, T., Zhang, K., Yuan, Q., Li, J., Pianetta, P., & Liu, Y. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202400318 · Cited by 8
Gradient-based sparse approximation for computed tomography
Sakhaee, E., Arreola, M. M., & Entezari, A. (2015) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2015.7164188 · Cited by 7
Soft-tissue imaging in low-dose, C-arm cone-beam CT using statistical image reconstruction
Wang, A., Schäfer, S., Stayman, J. W., Otake, Y., Sussman, M. S., Khanna, A. J., Gallia, G. L., & Siewerdsen, J. H. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2008421 · Cited by 7
Total Variation and Tomographic Imaging from Projections
Hansen, P. C., & Jørgensen, J. S. (2011) · Cited by 7
Iterative Computed Tomography Reconstruction from Sparse-View Data
Gopi, V. P., Palanisamy, P., Wahid, K., Babyn, P., & Cooper, D. M. L. (2016) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2016.1579 · Cited by 7
Shen, L., Zhao, W., & Xing, L. (2019) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2513032 · Cited by 8
Sparse-view, short-scan, dedicated cone-beam breast computed tomography: image quality assessment
Tseng, H. W., Karellas, A., & Vedantham, S. (2020) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/abb834 · Cited by 11
Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
Bai, T., Wang, B., Nguyen, D. T. D., Wang, B., Dong, B., Cong, W., Kalra, M. K., & Jiang, S. B. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3101241 · Cited by 7
Structural Sparsity in Multiple Measurements
Boßmann, F., Krause-Solberg, S., Maly, J., & Sissouno, N. (2021) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2021.3137599 · Cited by 7
Image reconstruction from data over two orthogonal arcs of limited‐angular ranges
Zhang, Z., Chen, B., Xia, D., Sidky, E. Y., & Pan, X. (2022) · Medical Physics · doi:10.1002/mp.15450 · Cited by 7
Self-citationCai, A., Wang, Y., Zhong, X., Yu, X., Zheng, Z., Wang, L., Li, L., & Yan, B. (2022) · Journal of X-Ray Science and Technology · doi:10.3233/xst-211095 · Cited by 7
Sparse Angle CBCT Reconstruction Based on Guided Image Filtering
Xu, S., Yang, B., Xu, C., Tian, J., Liu, Y., Yin, L., Liu, S., Zheng, W., & Liu, C. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.832037 · Cited by 7
A dataset-free deep learning method for low-dose CT image reconstruction
Ding, Q., Ji, H., Quan, Y., & Zhang, X. (2022) · Inverse Problems · doi:10.1088/1361-6420/ac8ac6 · Cited by 7
Holography - Recent Advances and Applications
Rosen, J. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.102216 · Cited by 9
Learning CT projection denoising from adjacent views
Hong, Z., Zeng, D., Tao, X., & Ma, J. (2022) · Medical Physics · doi:10.1002/mp.16115 · Cited by 7
Sparse-view CT reconstruction method for in-situ non-destructive testing of reinforced concrete
Peng, W., & Xiao, Y. (2023) · Nondestructive Testing And Evaluation · doi:10.1080/10589759.2023.2170374 · Cited by 9
A Novel Reconstruction of the Sparse-View CBCT Algorithm for Correcting Artifacts and Reducing Noise
Zhang, J., He, B., Yang, Z., & Kang, W. (2023) · Mathematics · doi:10.3390/math11092127 · Cited by 7
Extra projection data identification method for fast-continuous-rotation industrial cone-beam CT
Yang, M., Duan, S., Duan, J., Xiaolong, W., Li, X., Meng, F., & Zhang, J. (2013) · Journal of X-Ray Science and Technology · doi:10.3233/xst-130402 · Cited by 7
Dual-resolution image reconstruction for region-of-interest CT scan
Jin, S.-M., Shin, K.-Y., Yoo, S. K., Kim, J. G., Kim, K. H., Huh, Y., Lee, S. Y., & Kwon, O. K. (2014) · Journal of Instrumentation · doi:10.1088/1748-0221/9/07/c07008 · Cited by 7
Image deblurring associated with shearlet sparsity and weighted anisotropic total variation
Liu, Q., Li, B., & Min, L. (2015) · Journal of Electronic Imaging · doi:10.1117/1.jei.24.2.023001 · Cited by 7
Incorporation of the Superiorization Methodology into Biomedical Imaging Software
Langthaler, O. (2014) · Cited by 7
Volumetric CT with sparse detector arrays (and application to Si-strip photon counters)
Sisniega, A., Zbijewski, W. B., Stayman, J. W., Xu, J., Taguchi, K., Fredenberg, E., Lundqvist, M., & Siewerdsen, J. H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/1/90 · Cited by 7
Yan, B., Zhang, W., Li, L., Zhang, H., & Wang, L. (2016) · Physica Medica · doi:10.1016/j.ejmp.2016.07.094 · Cited by 7
A geometric calibration method for cone beam CT system
Xiang, Q., Wang, J., & Cai, Y. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2244579 · Cited by 7
ML-EM reconstruction model including total variation for low dose PET high resolution data
Chavez-Rivera, L. B., Máynez, L. O., Mejia, J. M., & Mederos, B. (2015) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2015.7582221 · Cited by 7
Experiments on sparsity assisted phase retrieval of phase objects
Gaur, C., Lochab, P., & Khare, K. (2017) · Journal of Optics · doi:10.1088/2040-8986/aa6357 · Cited by 7
A non-smooth and non-convex regularization method for limited-angle CT image reconstruction
Zhang, L., Zeng, L., Wang, C., & Guo, Y. (2018) · Journal of Inverse and Ill-Posed Problems · doi:10.1515/jiip-2017-0042 · Cited by 7
Design and Simulation Study of a CNT-Based Multisource Cubical CT System for Dynamic Objects
Gong, C., Zeng, L., Wang, C., & Ran, L. (2018) · Scanning · doi:10.1155/2018/6985698 · Cited by 7
Endoscopic System Based on Intraoral Camera and Image Processing
Fujimoto, M., Okuda, M., Yoshii, S., Ikezawa, S., Ueda, T., Tassery, H., Cuisinier, F., & Kitamura, C. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2866273 · Cited by 7
Deng, L., Yaşar, S., Ahmed, M. F., Jayarathna, S., Feng, P., Wei, B., Vedantham, S., Karellas, A., & Cho, S. H. (2019) · Journal of X-Ray Science and Technology · doi:10.3233/xst-180457 · Cited by 7
Chen, Y., Yin, F.-F., Zhang, Y., Zhang, Y., & Ren, L. (2019) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2019.06.02 · Cited by 7
Image reconstruction by Mumford–Shah regularization for low-dose CT with multi-GPU acceleration
Zhu, Y., Wang, Q., Li, M., Jiang, M. F., & Zhang, P. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab2c85 · Cited by 7
Gomi, T., Hara, H., Watanabe, Y., & Mizukami, S. (2020) · PLoS ONE · doi:10.1371/journal.pone.0244745 · Cited by 10
Deep High-Resolution Network for Low-Dose X-Ray CT Denoising
Bai, T., Nguyen, D. T. D., Wang, B., & Jiang, S. B. (2021) · Journal of Artificial Intelligence for Medical Sciences · doi:10.2991/jaims.d.210428.001 · Cited by 8
Low-Dose CT Denoising Using A Structure-Preserving Kernel Prediction Network
Xu, L., Zhang, Y., Liu, Y., Wang, D., Zhou, M., Ren, J., Wei, J., & Ye, Z. (2021) · Proceedings - International Conference on Image Processing · doi:10.1109/icip42928.2021.9506679 · Cited by 7
Dhou, S., Alkhodari, M., Ionascu, D., WILLIAMS, C. R., & Lewis, J. H. (2022) · Journal of Imaging · doi:10.3390/jimaging8020017 · Cited by 7
Gordon, R. (2010) · Springer eBooks · doi:10.1007/978-1-84996-314-5_10 · Cited by 7
Low-dose CBCT reconstruction via 3D dictionary learning
Liu, J., Chen, Y., Hu, Y., & Luo, L. (2016) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493371 · Cited by 7
Multispectral x-ray CT: multivariate statistical analysis for efficient reconstruction
Kheirabadi, M., Dahl, A. B., Olsen, U. L., Mustafa, W., & Lyksborg, M. (2017) · Developments in X-Ray Tomography · doi:10.1117/12.2273338 · Cited by 7
Rational approximations for tomographic reconstructions
Reynolds, M. J., Beylkin, G., & Monzón, L. (2013) · Inverse Problems · doi:10.1088/0266-5611/29/6/065020 · Cited by 7
Zhang, H., Wang, J., Ma, J., Lu, H., & Liang, Z. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1412.1732 · Cited by 9
Sparse-View Spectral CT Reconstruction Using Deep LearningPreprint
Mustafa, W., Kehl, C., Olsen, U. L., Gregersen, S. S., Malmgren-Hansen, D., Kehres, J., & Dahl, A. B. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2011.14842 · Cited by 13
2-Step Sparse-View CT Reconstruction with a Domain-Specific Perceptual NetworkPreprint
Wei, H., Schiffers, F., Würfl, T., Shen, D., Kim, D. J., Katsaggelos, A. K., & Cossairt, O. S. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2012.04743 · Cited by 21
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.