Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Items 201–300 of 1,000
Zhang, H., Wang, L., Yan, B., Li, L., Xi, X.-Q., & Lu, L. (2013) · Chinese Physics B · doi:10.1088/1674-1056/22/7/078701 · Cited by 55
Compressive Imaging: Structure, Sampling, Learning
Adcock, B., & Hansen, A. C. (2021) · Cambridge University Press eBooks · doi:10.1017/9781108377447 · Cited by 95
Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Wu, Q., Feng, R., Wei, H., Yu, J., & Zhang, Y. (2023) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2023.3281196 · Cited by 79
Generative Modeling in Sinogram Domain for Sparse-View CT Reconstruction
Guan, B., Yang, C., Zhang, L., Niu, S., Zhang, M., Wang, Y., Wu, W., & Liu, Q. (2023) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2023.3309474 · Cited by 82
Zhang, Y., Yin, F.-F., Pan, T., Vergalasova, I., & Ren, L. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.02.022 · Cited by 54
Lee, H., Xing, L., Lee, R., & Fahimian, B. (2012) · Medical Physics · doi:10.1118/1.3691901 · Cited by 54
Diffusion probabilistic priors for zero‐shot low‐dose CT image denoising
Liu, X., Xie, Y., Liu, C., Cheng, J., Diao, S., Tan, S., & Liang, X. (2024) · Medical Physics · doi:10.1002/mp.17431 · Cited by 86
Investigation of iterative image reconstruction in low-dose breast CT
Bian, J., Yang, K., Boone, J. M., Han, X., Sidky, E. Y., & Pan, X. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/11/2659 · Cited by 59
Self-citationExperimental evaluation of 3D electrical impedance tomography with total variation prior
González, G., Huttunen, J. M. J., Kolehmainen, V., Seppänen, A., & Vauhkonen, M. J. (2015) · Inverse Problems in Science and Engineering · doi:10.1080/17415977.2015.1113961 · Cited by 64
Leuschner, J., Schmidt, M., Ganguly, P. S., Andriiashen, V., Coban, S. B., Denker, A., Bauer, D. F., Hadjifaradji, A., Batenburg, K. J., Maaß, P., et al. (2021) · Journal of Imaging · doi:10.3390/jimaging7030044 · Cited by 58
Image features for misalignment correction in medical flat‐detector CT
Wicklein, J., Kunze, H., Kalender, W. A., & Kyriakou, Y. (2012) · Medical Physics · doi:10.1118/1.4736532 · Cited by 61
Dynamic tomography with a priori information
Myers, G. R., Kingston, A. M., Varslot, T. K., Turner, M. L., & Sheppard, A. P. (2011) · Applied Optics · doi:10.1364/ao.50.003685 · Cited by 63
Thériault-Lauzier, P., Tang, J., & Chen, G. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2461 · Cited by 58
Koneti, S., Roiban, L., Dalmas, F., Langlois, C., Gay, A., Cabiac, A., Grenier, T., Banjak, H., Maxim, V., & Épicier, T. (2019) · Materials Characterization · doi:10.1016/j.matchar.2019.02.009 · Cited by 52
Scale-Space Anisotropic Total Variation for Limited Angle Tomography
Huang, Y., Taubmann, O., Huang, X., Haase, V., Lauritsch, G., & Maier, A. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2824400 · Cited by 52
Sparse-view CBCT reconstruction via weighted Schatten p-norm minimization
Xu, C., Yang, B., Guo, F., Zheng, W., & Poignet, P. (2020) · Optics Express · doi:10.1364/oe.404471 · Cited by 55
Image reconstruction exploiting object sparsity in boundary-enhanced X-ray phase-contrast tomography
Sidky, E. Y., Anastasio, M. A., & Pan, X. (2010) · Optics Express · doi:10.1364/oe.18.010404 · Cited by 49
Self-citationCompressed Sensing for Ultrasound Computed Tomography
van Sloun, R. J. G., Pandharipande, A., Mischi, M., & Demi, L. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422135 · Cited by 51
Burger, M., Dirks, H., Frerking, L., Hauptmann, A., Helin, T., & Siltanen, S. (2017) · Inverse Problems · doi:10.1088/1361-6420/aa99cf · Cited by 60
ADMM-based deep reconstruction for limited-angle CT
Wang, J., Zeng, L., Wang, C., & Guo, Y. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab1aba · Cited by 55
Learning sub-sampling and signal recovery with applications in ultrasound imaging
Huijben, I. A. M., Veeling, B. S., Janse, C. K., Mischi, M. M., & Sloun, R. R. V. (2019) · TU/e Research Portal · Cited by 51
Phase Transitions and Cosparse Tomographic Recovery of Compound Solid Bodies from Few Projections
Deniţiu, A., Petra, S., Schnörr, C., & Schnörr, C. (2014) · Fundamenta Informaticae · doi:10.3233/fi-2014-1113 · Cited by 50
Vedantham, S., Shi, L., Karellas, A., O’Connell, A. M., & Conover, D. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/7921 · Cited by 50
Ultrafast Ultrasound Imaging as an Inverse Problem: Matrix-Free Sparse Image Reconstruction
Besson, A., Perdios, D., Martinez, F., Chen, Z., Carrillo, R. E., Arditi, M., Wiaux, Y., & Thiran, J. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2768583 · Cited by 54
Masuk, A. U. M., Salibindla, A. K. R., & Ni, R. (2019) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2019.103088 · Cited by 50
Multibeam x-ray optical system for high-speed tomography
Voegeli, W., Kajiwara, K., Kudo, H., Shirasawa, T., Liang, X., & Yashiro, W. (2020) · Optica · doi:10.1364/optica.384804 · Cited by 52
Multi-Channel Optimization Generative Model for Stable Ultra-Sparse-View CT Reconstruction
Wu, W., Pan, J., Wang, Y., Wang, S., & Zhang, J. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3376414 · Cited by 63
Li, X., & Luo, S. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-73 · Cited by 59
Spectral CT Reconstruction—ASSIST: Aided by Self-Similarity in Image-Spectral Tensors
Xia, W., Wu, W., Niu, S., Liu, F., Zhou, J., Yu, H., Wang, G., & Zhang, Y. (2019) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2019.2904207 · Cited by 55
Gong, C., & Zeng, L. (2019) · Signal Processing · doi:10.1016/j.sigpro.2019.06.031 · Cited by 50
Low-dose CT with deep learning regularization via proximal forward–backward splitting
Ding, Q., Chen, G., Zhang, X., Huang, Q., Ji, H., & Gao, H. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab831a · Cited by 55
Do CNNs Solve the CT Inverse Problem?
Sidky, E. Y., Lorente, I., Brankov, J. G., & Pan, X. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3020741 · Cited by 63
Self-citationCheslerean-Boghiu, T., Hofmann, F. C., Schultheiß, M., Pfeiffer, F., Pfeiffer, D., & Lasser, T. (2023) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2023.3240078 · Cited by 53
Hformer: highly efficient vision transformer for low-dose CT denoising
Zhang, S., Wang, Z.-X., Yang, H., Chen, Y.-L., Li, Y., Pan, Q., Wang, H., & Zhao, C. (2023) · Nuclear Science and Techniques · doi:10.1007/s41365-023-01208-0 · Cited by 57
Yan, H., Wang, X., Shi, F., Bai, T., Folkerts, M., Cerviño, L., Jiang, S. B., & Jia, X. (2014) · Medical Physics · doi:10.1118/1.4898324 · Cited by 48
Thing, R. S., Bernchou, U., Mainegra‐Hing, E., Hansen, O., & Brink, C. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/15/5781 · Cited by 49
Zhang, C., Li, Y., & Chen, G. (2021) · Medical Physics · doi:10.1002/mp.15183 · Cited by 51
Radiation dose reduction in medical x‐ray CT via Fourier‐based iterative reconstruction
Fahimian, B., Zhao, Y., Huang, Z., Fung, R., Mao, Y. L., Zhu, C., Khatonabadi, M., DeMarco, J. J., Osher, S., McNitt‐Gray, M. F., et al. (2013) · Medical Physics · doi:10.1118/1.4791644 · Cited by 52
Yang, X., Hofmann, R., Dapp, R., van de Kamp, T., Rolo, T. D. S., Xiao, X., Moosmann, J. P., Kashef, J., & Stotzka, R. (2015) · Optics Express · doi:10.1364/oe.23.005368 · Cited by 48
X-ray imaging and 3D reconstruction of in-flight exploding foil initiator flyers
Willey, T. M., Champley, K., Hodgin, R. L., Lauderbach, L., Bagge‐Hansen, M., May, C. M., Sanchez, N., Jensen, B. J., Iverson, A. J., & van Buuren, T. (2016) · Journal of Applied Physics · doi:10.1063/1.4953681 · Cited by 47
Liu, J., Zhang, Y., Zhao, Q., Lv, T., Wu, W., Cai, N., Quan, G., Yang, W., Chen, Y., Luo, L., et al. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab18db · Cited by 49
Data Extrapolation From Learned Prior Images for Truncation Correction in Computed Tomography
Huang, Y., Preuhs, A., Manhart, M. T., Lauritsch, G., & Maier, A. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3072568 · Cited by 59
Radiative Gaussian Splatting for Efficient X-Ray Novel View Synthesis
Cai, Y., Liang, Y., Wang, J., Wang, A., Zhang, Y., Yang, X., Zhou, Z., & Yuille, A. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-73232-4_16 · Cited by 116
Ouyang, L., Solberg, T. D., & Wang, J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/17/006 · Cited by 46
Nett, B. E., Brauweiler, R., Kalender, W. A., Rowley, H. A., & Chen, G. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/8/014 · Cited by 50
Reconstruction of 3D dynamic contrast‐enhanced magnetic resonance imaging using nonlocal means
Adluru, G., Taşdizen, T., Schabel, M. C., & DiBella, E. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22358 · Cited by 46
Xu, Q., Yang, D., Tan, J., Sawatzky, A., & Anastasio, M. A. (2016) · Medical Physics · doi:10.1118/1.4942812 · Cited by 50
Space-time tomography for continuously deforming objects
Zang, G., Idoughi, R., Tao, R., Lubineau, G., Wonka, P., & Heidrich, W. (2018) · ACM Transactions on Graphics · doi:10.1145/3197517.3201298 · Cited by 54
Deep Learning-Guided Image Reconstruction from Incomplete DataPreprint
Kelly, B., Matthews, T. P., & Anastasio, M. A. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1709.00584 · Cited by 69
DREAM-Net: Deep Residual Error Iterative Minimization Network for Sparse-View CT Reconstruction
Zhang, Y., Hu, D., Hao, S., Liu, J., Quan, G., Zhang, Y., Ji, X., & Chen, Y. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3225697 · Cited by 55
Superiorization of the ML-EM Algorithm
Garduño, E., & Herman, G. T. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2283529 · Cited by 45
Unsupervised Training of Denoisers for Low-Dose CT Reconstruction Without Full-Dose Ground Truth
Kim, K., Soltanayev, S., & Chun, S. Y. (2020) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2020.3007326 · Cited by 51
Yin, Z., Xia, K., He, Z., Zhang, J., Wang, S., & Zu, B. (2021) · Symmetry · doi:10.3390/sym13010126 · Cited by 48
A geometry-informed deep learning framework for ultra-sparse 3D tomographic image reconstruction
Shen, L., Zhao, W., Capaldi, D. P. I., Pauly, J. M., & Xing, L. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105710 · Cited by 50
Guest Editorial Compressive Sensing for Biomedical Imaging
Wang, G., Bresler, Y., & Ntziachristos, V. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2145070 · Cited by 53
Wang, Y., Chen, G., Tao, X., Bian, Z., Zeng, D., Zaidi, H., He, J., & Ma, J. (2021) · IEEE Access · doi:10.1109/access.2021.3049181 · Cited by 44
Denoising swin transformer and perceptual peak signal-to-noise ratio for low-dose CT image denoising
Zhang, B., Zhang, Y., Wang, B., He, X., Zhang, F., & Zhang, X. (2024) · Measurement · doi:10.1016/j.measurement.2024.114303 · Cited by 55
Chen, G., & Li, Y. (2015) · Medical Physics · doi:10.1118/1.4926430 · Cited by 47
4D micro-CT for cardiac and perfusion applications with view under sampling
Badea, C. T., Johnston, S. M., Qi, Y. P., & Johnson, G. A. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/11/011 · Cited by 44
GPU‐accelerated regularized iterative reconstruction for few‐view cone beam CT
Matenine, D., Goussard, Y., & Després, P. (2015) · Medical Physics · doi:10.1118/1.4914143 · Cited by 44
Investigation of optimization-based reconstruction with an image-total-variation constraint in PET
Zhang, Z., Ye, J., Chen, B., Perkins, A. E., Rose, S., Sidky, E. Y., Kao, C.-M., Xia, D., Tung, C., & Pan, X. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/16/6055 · Cited by 44
Self-citationA Sparse Reconstruction Framework for Fourier-Based Plane-Wave Imaging
Besson, A., Zhang, M., Varray, F., Liebgott, H., Friboulet, D. P., Wiaux, Y., Thiran, J., Carrillo, R. E., & Bernard, O. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2614996 · Cited by 51
Data Consistent Artifact Reduction for Limited Angle Tomography with Deep Learning Prior
Huang, Y., Preuhs, A., Lauritsch, G., Manhart, M. T., Huang, X., & Maier, A. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-33843-5_10 · Cited by 55
Compressive sensing in medical signal processing and imaging systems
Cabral, T. W., Khosravy, M., Dias, F. M., Monteiro, H. L. M., Lima, M. A. A., Silva, L. R. M., Naji, R., & Duque, C. A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-819361-7.00004-x · Cited by 45
Low‐dose CT reconstruction with Noise2Noise network and testing‐time fine‐tuning
Wu, D., Kim, K., & Li, Q. (2021) · Medical Physics · doi:10.1002/mp.15101 · Cited by 44
Shieh, C., Kipritidis, J., O'Brien, R. T., Kuncic, Z., & Keall, P. (2014) · Medical Physics · doi:10.1118/1.4868510 · Cited by 43
Some proximal methods for Poisson intensity CBCT and PET
Anthoine, S., Aujol, J., Boursier, Y., & Mélot, C. (2012) · Inverse Problems and Imaging · doi:10.3934/ipi.2012.6.565 · Cited by 49
Discriminative feature representation: an effective postprocessing solution to low dose CT imaging*
Chen, Y., Liu, J., Hu, Y., Yang, J., Shi, L., Shu, H., Gui, Z., Coatrieux, G., & Luo, L. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5c24 · Cited by 43
Single-shot interferogram analysis for accurate reconstruction of step phase objects
Singh, M., & Khare, K. (2017) · Journal of the Optical Society of America A · doi:10.1364/josaa.34.000349 · Cited by 43
Statistical Iterative CBCT Reconstruction Based on Neural Network
Chen, B., Xiang, K., Gong, Z., Wang, J., & Tan, S. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2829896 · Cited by 44
Image-Domain Material Decomposition for Spectral CT Using a Generalized Dictionary Learning
Wu, W., Chen, P., Wang, S., Vardhanabhuti, V., Liu, F., & Yu, H. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.2997880 · Cited by 49
Non-convex primal-dual algorithm for image reconstruction in spectral CT
Chen, B., Zhang, Z., Xia, D., Sidky, E. Y., & Pan, X. (2020) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2020.101821 · Cited by 51
Self-citationLimited-view ultrasonic guided wave tomography using an adaptive regularization method
Rao, J., Ratassepp, M., & Fan, Z. (2016) · Journal of Applied Physics · doi:10.1063/1.4967790 · Cited by 43
Improving Filtered Backprojection Reconstruction by Data-Dependent Filtering
Pelt, D. M., & Batenburg, K. J. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2341971 · Cited by 43
Dang, H., Wang, A., Sussman, M. S., Siewerdsen, J. H., & Stayman, J. W. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/17/4799 · Cited by 42
Sparse-view cone beam CT reconstruction using dual CNNs in projection domain and image domain
Chao, L., Wang, Z., Zhang, H., Xu, W., Zhang, P., & Li, Q. (2021) · Neurocomputing · doi:10.1016/j.neucom.2021.12.096 · Cited by 50
RegFormer: A Local–Nonlocal Regularization-Based Model for Sparse-View CT Reconstruction
Xia, W., Yang, Z., Lu, Z., Wang, Z., & Zhang, Y. (2023) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2023.3281148 · Cited by 54
X-ray microtomography for materials characterization
Hanke, R., Fuchs, T. O. J., Salamon, M., & Zabler, S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100040-3.00003-1 · Cited by 41
Lee, D., Lee, J., Kim, H., Lee, T., Soh, J., Park, M., Kim, C.-H., Lee, Y. J., & Cho, S. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2765760 · Cited by 41
DEEP BACK PROJECTION FOR SPARSE-VIEW CT RECONSTRUCTION
Ye, D. H., Buzzard, G. T., Ruby, M., & Bouman, C. A. (2018) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2018.8646669 · Cited by 58
StatNet: Statistical Image Restoration for Low-Dose CT using Deep Learning
Choi, K., Lim, J. S., & Kim, S. (2020) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2020.2998413 · Cited by 44
Fast iterative reconstruction of differential phase contrast X-ray tomograms
Nilchian, M., Vonesch, C., Modregger, P., Stampanoni, M., & Unser, M. A. (2013) · Optics Express · doi:10.1364/oe.21.005511 · Cited by 44
Zbijewski, W. B., Gang, G. J., Xu, J., Wang, A., Stayman, J. W., Taguchi, K., Carrino, J. A., & Siewerdsen, J. H. (2014) · Medical Physics · doi:10.1118/1.4863598 · Cited by 43
Motion-aware temporal regularization for improved 4D cone-beam computed tomography
Mory, C., Janssens, G., & Rit, S. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/6856 · Cited by 49
Huang, Y., Huang, X., Taubmann, O., Xia, Y., Haase, V., Hornegger, J., Lauritsch, G., & Maier, A. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa71bf · Cited by 48
An Image Reconstruction Method Based on Total Variation and Wavelet Tight Frame for Limited-Angle CT
Luo, X., Yu, W. B., & Wang, C. (2017) · IEEE Access · doi:10.1109/access.2017.2779148 · Cited by 40
Low-Dose CT Image Denoising with Improving WGAN and Hybrid Loss Function
Li, Z., Shi, W., Xing, Q., Miao, Y., He, W., Yang, H., & Jiang, Z. (2021) · Computational and Mathematical Methods in Medicine · doi:10.1155/2021/2973108 · Cited by 53
Domain‐adaptive denoising network for low‐dose CT via noise estimation and transfer learning
Wang, J., Tang, Y., Wu, Z., Tsui, B. M. W., Chen, W., Yang, X., Zheng, J., & Li, M. (2022) · Medical Physics · doi:10.1002/mp.15952 · Cited by 44
Super-Resolution for Computed Tomography Based on Discrete Tomography
van Aarle, W., Batenburg, K. J., Gompel, G. V., de Casteele, E. V., & Sijbers, J. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2297025 · Cited by 39
Lu, Y., Chan, H., Wei, J., & Hadjiiski, L. M. (2010) · Medical Physics · doi:10.1118/1.3505851 · Cited by 39
Sparsity-regularized image reconstruction of decomposed K-edge data in spectral CT
Xu, Q., Sawatzky, A., Anastasio, M. A., & Schirra, C. O. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/10/n65 · Cited by 42
A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging
Yan, H., Zhen, X., Folkerts, M., Li, Y., Pan, T., Cerviño, L., Jiang, S. B., & Jia, X. (2014) · Medical Physics · doi:10.1118/1.4881326 · Cited by 39
Z-Index Parameterization for Volumetric CT Image Reconstruction via 3-D Dictionary Learning
Bai, T., Yan, H., Jia, X., Jiang, S. B., Wang, G., & Mou, X. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2759819 · Cited by 40
Hurley, R., Herbold, E. B., & Pagan, D. C. (2018) · Journal of Applied Crystallography · doi:10.1107/s1600576718006957 · Cited by 39
Tang, X., Krupinski, E. A., Xie, H., & Stillman, A. E. (2018) · Medical Physics · doi:10.1002/mp.13095 · Cited by 52
Image Restoration for Low-Dose CT via Transfer Learning and Residual Network
Zhong, A., Li, B., Luo, N., Xu, Y. X., Zhou, L., & Zhen, X. (2020) · IEEE Access · doi:10.1109/access.2020.3002534 · Cited by 38
Tang, Y., Du, Q., Wang, J., Wu, Z., Li, Y., Li, M., Yang, X., & Zheng, J. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105759 · Cited by 41
A Spectral Approach to Total Variation
Gilboa, G. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-38267-3_4 · Cited by 39
An in-situ study of stress evolution and fracture growth during compression of concrete
Hurley, R., & Pagan, D. C. (2019) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2019.03.015 · Cited by 39
Sparse-view and limited-angle CT reconstruction with untrained networks and deep image prior
Shu, Z., & Entezari, A. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107167 · Cited by 43
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.