Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Items 501–600 of 1,000
FONT-SIR: Fourth-Order Nonlocal Tensor Decomposition Model for Spectral CT Image Reconstruction
Chen, X., Xia, W., Liu, Y., Chen, H., Zhou, J., Zha, Z., Wen, B., & Zhang, Y. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3156270 · Cited by 21
Deep Unfolding of the DBFB Algorithm With Application to ROI CT Imaging With Limited Angular Density
Savanier, M., Chouzenoux, É., Pesquet, J.-C., & Riddell, C. (2023) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2023.3279053 · Cited by 22
Stsepankou, D., Arns, A., Ng, S. K., Zygmanski, P., & Hesser, J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/19/5955 · Cited by 21
Noise reduction in low‐dose cone beam CT by incorporating prior volumetric image information
Ouyang, L., Solberg, T. D., & Wang, J. (2012) · Medical Physics · doi:10.1118/1.3702592 · Cited by 21
Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids
Ren, L., Chen, Y., Zhang, Y., Giles, W. M., Jin, J., & Yin, F.-F. (2015) · Technology in Cancer Research & Treatment · doi:10.1177/1533034615587615 · Cited by 21
Chen, X., Ouyang, L., Yan, H., Jia, X., Li, B., Lyu, Q., Zhang, Y., & Wang, J. (2017) · Medical Physics · doi:10.1002/mp.12326 · Cited by 21
Wavelet tight frame and prior image-based image reconstruction from limited-angle projection data
Wang, C., Zeng, L., Guo, Y., & Zhang, L. (2017) · Inverse Problems and Imaging · doi:10.3934/ipi.2017043 · Cited by 21
Chen, Y., Liu, J., Xie, L., Hu, Y., Shu, H., Luo, L., Zhang, L., Gui, Z., & Coatrieux, G. (2017) · Scientific Reports · doi:10.1038/s41598-017-13520-y · Cited by 21
DaNet: dose-aware network embedded with dose-level estimation for low-dose CT imaging
Huang, Z., Chen, Z., Chen, J., Lü, P., Quan, G., Du, Y., Li, C., Gu, Z., Yang, Y., Liu, X., et al. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abc5cc · Cited by 23
Belief Propagation Reconstruction for Discrete Tomography
Gouillart, E., Krząkała, F., Mézard, M., & Zdeborová, L. (2012) · Cited by 21
Sperl, J. I., Beque, D., Kudielka, G. P., Mahdi, K., Edic, P. M., & Cozzini, C. (2014) · Optics Express · doi:10.1364/oe.22.000450 · Cited by 23
Liang, K., Yang, H., & Xing, Y. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1804.04289 · Cited by 21
Zhang, X., Sisniega, A., Zbijewski, W. B., Lee, J., Jones, C. K., Wu, P., Han, R., Uneri, A., Vagdargi, P., Helm, P. A., et al. (2023) · Medical Physics · doi:10.1002/mp.16351 · Cited by 21
GDAFormer: Gradient-guided Dual Attention Transformer for Low-Dose CT image denoising
Jiang, G., Luo, T., Xu, H., Nie, S., Song, Y., & He, Z. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106260 · Cited by 23
Recent Advances in Hybrid Molecular Imaging Systems
Kim, J., & Lee, J. H. (2014) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-0034-1371014 · Cited by 21
Sparsity promoting regularization for effective noise suppression in SPECT image reconstruction
Zheng, W., Li, S., Król, A., Schmidtlein, C. R., Zeng, X., & Xu, Y. (2019) · Inverse Problems · doi:10.1088/1361-6420/ab23da · Cited by 20
Zhang, Y., Huang, X., & Wang, J. (2019) · Visual Computing for Industry Biomedicine and Art · doi:10.1186/s42492-019-0033-6 · Cited by 24
Zhao, S., Xia, D., & Zhao, X. (2021) · Inverse Problems · doi:10.1088/1361-6420/abff79 · Cited by 20
Examining the micromechanics of cementitious composites using In-Situ X-ray measurements
Hurley, R., Pagan, D. C., Herbold, E. B., & Zhai, C. (2023) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2023.112162 · Cited by 20
Guo, X., Li, Y., Chang, D., He, P., Feng, P., Yu, H., & Wu, W. (2023) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2023.3328278 · Cited by 26
Super-sparsely view-sampled cone-beam CT by incorporating prior data
Abbas, S., Min, J., & Cho, S. (2013) · Journal of X-Ray Science and Technology · doi:10.3233/xst-130367 · Cited by 20
Directional sinogram interpolation for sparse angular acquisition in cone-beam computed tomography
Hua, Z., & Sonke, J. (2013) · Journal of X-Ray Science and Technology · doi:10.3233/xst-130401 · Cited by 20
A new weighted anisotropic total variation algorithm for limited angle tomography
Huang, Y., Taubmann, O., Huang, X., Haase, V., Lauritsch, G., & Maier, A. (2016) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493336 · Cited by 20
Zhang, Y., Yin, F.-F., Zhang, Y., & Ren, L. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6913 · Cited by 23
Undersampled Dynamic X-Ray Tomography With Dimension Reduction Kalman Filter
Hakkarainen, J., Purisha, Z., Solonen, A., & Siltanen, S. (2019) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2019.2896527 · Cited by 26
Nth-order linear algorithm for diffuse correlation tomography
Zhang, X., Gui, Z., Qiao, Z., Liu, Y., & Shang, Y. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.002365 · Cited by 22
Limited-View Cone-Beam CT Reconstruction Based on an Adversarial Autoencoder Network With Joint Loss
Dai, X., Bai, J., Liu, T., & Xie, L. (2018) · IEEE Access · doi:10.1109/access.2018.2890135 · Cited by 24
Mean gradient descent: an optimization approach for single-shot interferogram analysis
Rajora, S., Butola, M., & Khare, K. (2019) · Journal of the Optical Society of America A · doi:10.1364/josaa.36.0000d7 · Cited by 22
Electron Tomography in Materials Science
Leary, R. K., & Midgley, P. A. (2019) · Springer handbooks · doi:10.1007/978-3-030-00069-1_26 · Cited by 20
Fast Split Bregman Based Deconvolution Algorithm for Airborne Radar Imaging
Zhang, Y., Zhang, Q., Zhang, Y., Pei, J., Huang, Y., & Yang, J. (2020) · Remote Sensing · doi:10.3390/rs12111747 · Cited by 20
Soft Autoencoder and Its Wavelet Adaptation Interpretation
Fan, F., Li, M., Teng, Y., & Wang, G. (2020) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2020.3013796 · Cited by 27
Weighted adaptive non-local dictionary for low-dose CT reconstruction
Yu, H., Wang, S., Wu, W., Gong, C., Wang, L., Pi, Z., & Liu, F. (2020) · Signal Processing · doi:10.1016/j.sigpro.2020.107871 · Cited by 21
Review of reconstruction algorithms with incomplete projection data of computed tomography
Yang, F., Dinghua, Z., Huang, K., Kun, W., & Xu, Z. (2014) · Acta Physica Sinica · doi:10.7498/aps.63.058701 · Cited by 20
A differential equations approach to l 1 -minimization with applications to array imaging
Moscoso, M., Novikov, A., Papanicolaou, G., & Ryzhik, L. (2012) · Inverse Problems · doi:10.1088/0266-5611/28/10/105001 · Cited by 21
Zhang, Y., Ma, J., Iyengar, P., Zhong, Y., & Wang, J. (2017) · Medical Physics · doi:10.1002/mp.12259 · Cited by 20
Automatic alignment for three-dimensional tomographic reconstruction
van Leeuwen, T., Maretzke, S., & Batenburg, K. J. (2017) · Inverse Problems · doi:10.1088/1361-6420/aaa0f8 · Cited by 20
Wang, J., & Xing, L. (2010) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2010-0271 · Cited by 20
Jørgensen, J. S., Sidky, E. Y., & Pan, X. (2011) · arXiv (Cornell University) · Cited by 20
Self-citationLin, J., Li, J., Dou, J., Zhong, L., Di, J., & Qin, Y. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106593 · Cited by 19
Golla, A., Chung, K., Russ, T., Schad, L. R., & Zöllner, F. G. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2019.01.002 · Cited by 25
A New Approach for Cylindrical Steel Structure Deformation Monitoring by Dense Point Clouds
Jia, D., Zhang, W., Wang, Y., & Liu, Y. (2021) · Remote Sensing · doi:10.3390/rs13122263 · Cited by 19
Choi, K., Lim, J. S., & Kim, S. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.118072 · Cited by 20
A comprehensive survey on deep learning techniques in CT image quality improvement
Li, D., Ma, L., Li, J., Qi, S., Yao, Y., & Teng, Y. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02631-y · Cited by 24
Hybrid U-Net and Swin-transformer network for limited-angle cardiac computed tomography
Xu, Y., Han, S., Wang, D., Wang, G., Maltz, J. S., & Yu, H. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad3db9 · Cited by 27
One-Sample Diffusion Modeling in Projection Domain for Low-Dose CT Imaging
Huang, B., Lu, S., Zhang, L., Lin, B., Wu, W., & Liu, Q. (2024) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2024.3392248 · Cited by 28
Superiorization for Image Analysis
Herman, G. T. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-07148-0_1 · Cited by 19
Image recovery via geometrically structured approximation
Ji, H., Luo, Y., & Shen, Z. (2015) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2015.08.012 · Cited by 20
A new iterative reconstruction algorithm for 2D exterior fan-beam CT
Zeng, L., Liu, B., Liu, L., & Xiang, C. (2010) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2010-0259 · Cited by 19
Dang, J., Gu, X., Pan, T., & Wang, J. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.10.029 · Cited by 19
Optimizing 4DCBCT projection allocation to respiratory bins
O'Brien, R. T., Kipritidis, J., Shieh, C., & Keall, P. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/19/5631 · Cited by 19
Niu, S., Zhang, Y., Zhong, Y., Liu, G., Lu, S., Zhang, X., Hu, S., Wang, T., Yu, G., & Wang, J. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.10.022 · Cited by 19
Luo, F., Li, W., Tu, W., & Wu, W. (2018) · IEEE Access · doi:10.1109/access.2018.2873713 · Cited by 19
Wang, C., Luo, X., Yu, W. B., Guo, Y., & Zhang, L. (2018) · Applied Mathematical Modelling · doi:10.1016/j.apm.2018.09.038 · Cited by 19
A Novel Total Variation Model for Low-Dose CT Image Denoising
Chen, W., Shao, Y., Wang, Y., Zhang, Q., Liu, Y., Yao, L., Chen, Y., Yang, G., & Gui, Z. (2018) · IEEE Access · doi:10.1109/access.2018.2885514 · Cited by 20
Cho, S., Lim, S., Kim, C.-H., Wi, S., Kwon, T., Youn, W. S., Lee, S. H., Kang, B. S., & Cho, S. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.01.004 · Cited by 19
Neural Networks and Deep Learning
Adcock, B., & Hansen, A. C. (2021) · Cambridge University Press eBooks · doi:10.1017/9781108377447.024 · Cited by 19
CT-Guided Interventions: Current Practice and Future Directions
Gupta, R., Walsh, C. J., Wang, I. S., Kachelrieß, M., Kuntz, J., & Bartling, S. H. (2013) · Springer eBooks · doi:10.1007/978-1-4614-7657-3_12 · Cited by 19
Zhang, C., Zhang, T., Zheng, J., Li, M., Lu, Y., You, J., & Guan, Y. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/831790 · Cited by 19
Sparse-view computed laminography with a spherical sinusoidal scan for nondestructive testing
Abbas, S., Park, M., Min, J., Kim, H. K., & Cho, S. (2014) · Optics Express · doi:10.1364/oe.22.017745 · Cited by 18
Niu, S., Huang, J., Bian, Z., Zeng, D., Chen, W., Yu, G., Liang, Z., & Ma, J. (2017) · Journal of X-Ray Science and Technology · doi:10.3233/xst-16239 · Cited by 18
OPTIMAL TRANSPORT, CYCLEGAN, AND PENALIZED LS FOR UNSUPERVISED LEARNING IN INVERSE PROBLEMS
Sim, B., Oh, G., Lim, S., & Ye, J. C. (2019) · Cited by 18
Sparse View CT Image Reconstruction Based on Total Variation and Wavelet Frame Regularization
Qu, Z., Yan, X., Pan, J., & Chen, P. (2020) · IEEE Access · doi:10.1109/access.2020.2982229 · Cited by 19
Iterative Reconstruction for Low-Dose CT Using Deep Gradient Priors of Generative Model
He, Z., Zhang, Y., Guan, Y., Guan, B., Niu, S., Zhang, Y., Chen, Y., & Liu, Q. (2022) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2022.3148373 · Cited by 22
A residual dense network assisted sparse view reconstruction for breast computed tomography
Fu, Z., Tseng, H. W., Vedantham, S., Karellas, A., & Bilgin, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-77923-0 · Cited by 25
RAD-UNet: a Residual, Attention-Based, Dense UNet for CT Sparse Reconstruction
Qiao, Z., & Du, C. (2022) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-022-00685-w · Cited by 19
A Transformer-Based Iterative Reconstruction Model for Sparse-View CT Reconstruction
Xia, W., Yang, Z., Zhou, Q., Lu, Z., Wang, Z., & Zhang, Y. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16446-0_75 · Cited by 31
MM-Net: Multiframe and Multimask-Based Unsupervised Deep Denoising for Low-Dose Computed Tomography
Jeon, S.-Y., Kim, W., & Choi, J. (2022) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2022.3224553 · Cited by 24
RBP-DIP: Residual back projection with deep image prior for ill-posed CT reconstruction
Shu, Z., & Entezari, A. (2024) · Neural Networks · doi:10.1016/j.neunet.2024.106740 · Cited by 22
Rui, X., Cheng, L., Long, Y. Q., Fu, L., Alessio, A. M., Asma, E., Kinahan, P. E., & Man, B. D. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/19/7437 · Cited by 18
Fu, J., Hu, X., Velroyen, A., Bech, M., Jiang, M., & Pfeiffer, F. (2015) · PLoS ONE · doi:10.1371/journal.pone.0117502 · Cited by 20
Park, H.-G., Shin, Y.-G., & Lee, H. (2014) · Technology in Cancer Research & Treatment · doi:10.7785/tcrt.2012.500429 · Cited by 18
Moving Beam-Blocker-Based Low-Dose Cone-Beam CT
Lee, T., Lee, C., Baek, J., & Cho, S. (2016) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2016.2604343 · Cited by 18
Cone-beam CT reconstruction for non-periodic organ motion using time-ordered chain graph model
Nakano, M., Haga, A., Kotoku, J., Magome, T., Masutani, Y., Hanaoka, S., Kida, S., & Nakagawa, K. (2017) · Radiation Oncology · doi:10.1186/s13014-017-0879-8 · Cited by 18
Shading correction assisted iterative cone-beam CT reconstruction
Yang, C., Wu, P., Gong, S., Wang, J., Lyu, Q., Tang, X., & Niu, T. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa8e62 · Cited by 18
A Novel Stationary CT Scheme Based on High-Density X-Ray Sources Device
Duan, Y., Cheng, H., Wang, K., & Mou, X. (2020) · IEEE Access · doi:10.1109/access.2020.3003308 · Cited by 18
Total variation regularization for large-scale X-ray tomography
Hämäläinen, K., Harhanen, L., Hauptmann, A., Kallonen, A., Niemi, E., & Siltanen, S. (2014) · International journal of tomography and simulation · Cited by 28
3D Unet Generative Adversarial Network for Attenuation Correction of SPECT Images
Trung, N. T., Chi, T. N., Hoang, M. D., Thai, H. N., & Duc, T. N. (2020) · International Conference on Recent Advances in Signal Processing, Telecommunications & Computing (SigTelCom) · doi:10.1109/sigtelcom49868.2020.9199018 · Cited by 21
Moghari, M. D., Zhou, L., Yu, B., Young, N., Moore, K., Evans, A., Fulton, R., & Kyme, A. Z. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abe917 · Cited by 22
Noise-Generating-Mechanism-Driven Unsupervised Learning for Low-Dose CT Sinogram Recovery
Zeng, D., Wang, L., Geng, M., Li, S., Deng, Y. P., Xie, Q., Li, D., Zhang, H., Li, Y., Xu, Z., et al. (2021) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2021.3083361 · Cited by 19
High-Resolution Full-3D Specimen Imaging for Lumpectomy Margin Assessment in Breast Cancer
Kulkarni, S., Kulkarni, K., Schacht, D. V., Bhole, S., Reiser, I., Abé, H., Bao, J. J., Bethke, K. P., Hansen, N. M., Jaskowiak, N. T., et al. (2021) · Annals of Surgical Oncology · doi:10.1245/s10434-021-10499-9 · Cited by 18
Self-citationDictionary learning for data recovery in positron emission tomography
Valiollahzadeh, S. M., Clark, J. W., & Mawlawi, O. R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/15/5853 · Cited by 18
L0 constrained sparse reconstruction for multi-slice helical CT reconstruction
Hu, Y., Xie, L., Luo, L., Nunes, J., & Toumoulin, C. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/018 · Cited by 18
Metal artifact reduction for CT-based luggage screening
Karimi, S., Martz, H. E., & Cosman, P. C. (2015) · Journal of X-Ray Science and Technology · doi:10.3233/xst-150499 · Cited by 18
Hegazy, M. A. A., Cho, M. H., & Lee, S. Y. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0240-8 · Cited by 18
Total image constrained diffusion tensor for spectral computed tomography reconstruction
Niu, S., Bian, Z., Zeng, D., Yu, G., Ma, J., & Wang, J. (2018) · Applied Mathematical Modelling · doi:10.1016/j.apm.2018.11.020 · Cited by 18
3-D Indoor Device-Free Object Detection by Passive Radio Frequency Identification
Xu, G., Sharma, P., Hui, X., & Kan, E. C.-C. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3059309 · Cited by 21
Du, Q., Tang, Y., Wang, J., Hou, X., Wu, Z., Li, M., Yang, X., & Zheng, J. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106419 · Cited by 17
Quantification of pollen viability in Lantana camara by digital holographic microscopy
Kumar, V., Goyal, N., Prasad, A., Babu, S. C., Khare, K., & Yadav, G. (2023) · Quantitative Plant Biology · doi:10.1017/qpb.2023.5 · Cited by 17
Xu, S., Hu, Y., Li, B., Inscoe, C. R., Tyndall, D. A., Lee, Y. Z., Lü, J., & Zhou, O. Z. (2023) · Communications Engineering · doi:10.1038/s44172-023-00123-x · Cited by 17
Tomographic Reconstruction: General Approach to Fast Back-Projection Algorithms
Dmitry, P., Gilmanov, M., Kazimirov, D. D., Chukalina, M. V., Ingacheva, A. S., Petr, K., & Nikolaev, D. (2023) · Mathematics · doi:10.3390/math11234759 · Cited by 17
Wilde, D. D., Zanier, O., Mutten, R. D., Jin, M. C., Regli, L., Serra, C., & Staartjes, V. E. (2025) · Medical Image Analysis · doi:10.1016/j.media.2025.103454 · Cited by 20
An algorithm for computed tomography image reconstruction from limited-view projections
Linyuan, W., Lei, L., Yan, B., Cheng-shun, J., Hao-Yu, W., & Shang-Lian, B. (2010) · Chinese Physics B · doi:10.1088/1674-1056/19/8/088106 · Cited by 17
Construction model for total variation regularization parameter
Gong, G., Zhang, H., & Yao, M. (2014) · Optics Express · doi:10.1364/oe.22.010500 · Cited by 17
Image reconstruction algorithm based on inexact alternating direction total-variation minimization
Linyuan, W., Zhang, H., Ai-Long, C., Yan, B., Lei, L., & Hu, G. (2013) · Acta Physica Sinica · doi:10.7498/aps.62.198701 · Cited by 17
Zhang, Y., Deng, X., Yin, F.-F., & Ren, L. (2017) · Medical Physics · doi:10.1002/mp.12647 · Cited by 17
Factor Graphs with NUV Priors and Iteratively Reweighted Descent for Sparse Least Squares and More
Loeliger, H., Ma, B., Malmberg, H., & Wadehn, F. (2018) · International Symposium on Turbo Codes and Iterative Information Processing · doi:10.1109/istc.2018.8625332 · Cited by 17
Multi-pass approach to reduce cone-beam artifacts in a circular orbit cone-beam CT system
Han, C., & Baek, J. (2019) · Optics Express · doi:10.1364/oe.27.010108 · Cited by 17
Empirical average-case relation between undersampling and sparsity in X-ray CT
Jørgensen, J. S., Sidky, E. Y., Hansen, P. C., & Pan, X. (2015) · Inverse Problems and Imaging · doi:10.3934/ipi.2015.9.431 · Cited by 17
Self-citationDifferentiated Backprojection Domain Deep Learning for Conebeam Artifact Removal
Han, Y., Kim, J., & Ye, J. C. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3000341 · Cited by 17
Learning Image From Projection: A Full-Automatic Reconstruction (FAR) Net for Computed Tomography
Ma, G., Zhu, Y., & Zhao, X. (2020) · IEEE Access · doi:10.1109/access.2020.3039638 · Cited by 21
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.