Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Items 101–200 of 1,000
Investigation of Low-Dose CT Image Denoising Using Unpaired Deep Learning Methods
Li, Z., Zhou, S., Huang, J., Yu, L., & Jin, M. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.3007583 · Cited by 113
Kudo, H., Suzuki, T., & Rashed, E. A. (2013) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2223-4292.2013.06.01 · Cited by 147
A Total Variation Spectral Framework for Scale and Texture Analysis
Gilboa, G. (2014) · SIAM Journal on Imaging Sciences · doi:10.1137/130930704 · Cited by 106
An algorithm for total variation regularization in high-dimensional linear problems
Defrise, M., Vanhove, C., & Liu, X. (2011) · Inverse Problems · doi:10.1088/0266-5611/27/6/065002 · Cited by 101
Fast parallel algorithms for the x‐ray transform and its adjoint
Gao, H. (2012) · Medical Physics · doi:10.1118/1.4761867 · Cited by 96
Augmentation of CBCT Reconstructed From Under-Sampled Projections Using Deep Learning
Jiang, Z., Chen, Y., Zhang, Y., Ge, Y., Yin, F.-F., & Ren, L. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2912791 · Cited by 108
Iterative 4D cardiac micro-CT image reconstruction using an adaptive spatio-temporal sparsity prior
Ritschl, L., Sawall, S., Knaup, M., Heß, A., & Kachelrieß, M. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/6/1517 · Cited by 94
Yu, Z., Leng, S., Li, Z., & McCollough, C. H. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/6707 · Cited by 94
DPIR-Net: Direct PET Image Reconstruction Based on the Wasserstein Generative Adversarial Network
Hu, Z., Xue, H., Zhang, Q., Gao, J., Zhang, N., Zou, S., Teng, Y., Liu, X., Yang, Y., Liang, D., et al. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.2995717 · Cited by 103
Bera, S., & Biswas, P. K. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3094525 · Cited by 107
A technique for estimating 4D‐CBCT using prior knowledge and limited‐angle projections
Zhang, Y., Yin, F.-F., Segars, W. P., & Ren, L. (2013) · Medical Physics · doi:10.1118/1.4825097 · Cited by 92
Jin, J., Ren, L., Liu, Q., Kim, J., Wen, N. W., Guan, H., Movsas, B., & Chetty, I. J. (2010) · Medical Physics · doi:10.1118/1.3497272 · Cited by 89
A review of GPU-based medical image reconstruction
Després, P., & Jia, X. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.07.024 · Cited by 92
SPARE: Sparse‐view reconstruction challenge for 4D cone‐beam CT from a 1‐min scan
Shieh, C., Gonzalez, Y., Li, B., Jia, X., Rit, S., Mory, C., Riblett, M. J., Hugo, G. D., Zhang, Y., Jiang, Z., et al. (2019) · Medical Physics · doi:10.1002/mp.13687 · Cited by 90
Directional-TV algorithm for image reconstruction from limited-angular-range data
Zhang, Z., Chen, B., Xia, D., Sidky, E. Y., & Pan, X. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102030 · Cited by 107
Self-citationYan, H., Cerviño, L., Jia, X., & Jiang, S. B. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/7/2063 · Cited by 88
X-Ray CT Image Reconstruction via Wavelet Frame Based Regularization and Radon Domain Inpainting
Dong, B., Li, J., & Shen, Z. (2012) · Journal of Scientific Computing · doi:10.1007/s10915-012-9579-6 · Cited by 88
Statistical iterative reconstruction using adaptive fractional order regularization
Zhang, Y., Wang, Y., Zhang, W., Lin, F., Pu, Y., & Zhou, J. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.001015 · Cited by 93
Niu, T., & Zhu, L. (2012) · Medical Physics · doi:10.1118/1.4729837 · Cited by 86
Superiorization: An optimization heuristic for medical physics
Herman, G. T., Garduño, E., Davidi, R., & Censor, Y. (2012) · Medical Physics · doi:10.1118/1.4745566 · Cited by 86
Sidky, E. Y., Chartrand, R., Boone, J. M., & Pan, X. (2014) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2014.2300862 · Cited by 96
Self-citationStatistical Interior Tomography
Xu, Q., Mou, X., Wang, G., Sieren, J., Hoffman, E. A., & Yu, H. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2106161 · Cited by 95
Structure-Aware Sparse-View X-Ray 3D Reconstruction
Cai, Y., Wang, J., Yuille, A., Zhou, Z., & Wang, A. (2024) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr52733.2024.01062 · Cited by 164
Few-view image reconstruction with fractional-order total variation
Zhang, Y., Zhang, W., Lei, Y., & Zhou, J. (2014) · Journal of the Optical Society of America A · doi:10.1364/josaa.31.000981 · Cited by 84
Projected Subgradient Minimization Versus Superiorization
Censor, Y., Davidi, R., Herman, G. T., Schulte, R. W., & Tetruashvili, L. (2013) · Journal of Optimization Theory and Applications · doi:10.1007/s10957-013-0408-3 · Cited by 83
How little data is enough? Phase-diagram analysis of sparsity-regularized X-ray computed tomography
Jørgensen, J. S., & Sidky, E. Y. (2015) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2014.0387 · Cited by 89
Self-citationA hybrid metal artifact reduction algorithm for x‐ray CT
Zhang, Y., Yan, H., Jia, X., Yang, J. Q., Jiang, S. B., & Mou, X. (2013) · Medical Physics · doi:10.1118/1.4794474 · Cited by 82
Low-dose CT restoration via stacked sparse denoising autoencoders
Liu, Y., & Zhang, Y. (2018) · Neurocomputing · doi:10.1016/j.neucom.2018.01.015 · Cited by 87
Robust Low-Dose CT Sinogram Preprocessing via Exploiting Noise-Generating Mechanism
Xie, Q., Zeng, D., Zhao, Q., Meng, D., Xu, Z., Liang, Z., & Ma, J. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2767290 · Cited by 79
An investigation of 4D cone‐beam CT algorithms for slowly rotating scanners
Bergner, F., Berkus, T., Oelhafen, M., Kunz, P., Pan, T., Grimmer, R., Ritschl, L., & Kachelrieß, M. (2010) · Medical Physics · doi:10.1118/1.3480986 · Cited by 93
MetaInv-Net: Meta Inversion Network for Sparse View CT Image Reconstruction
Zhang, H., Liu, B., Yu, H., & Dong, B. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3033541 · Cited by 93
Computationally efficient deep neural network for computed tomography image reconstruction
Wu, D., Kim, K., & Li, Q. (2019) · Medical Physics · doi:10.1002/mp.13627 · Cited by 95
Optimization-based image reconstruction from sparse-view data in offset-detector CBCT
Bian, J., Wang, J., Han, X., Sidky, E. Y., Shao, L., & Pan, X. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/2/205 · Cited by 81
Self-citationTime-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm
Chen, G., Thériault-Lauzier, P., Tang, J., Nett, B. E., Leng, S., Zambelli, J. N., Qi, Z., Bevins, N., Raval, A. N., Reeder, S. B., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2172951 · Cited by 82
Xu, J., Zhao, Y., Li, H., & Zhang, P. (2019) · Inverse Problems · doi:10.1088/1361-6420/ab08f9 · Cited by 85
Kim, H., Chen, J., Wang, A., Chuang, C., Held, M., & Pouliot, J. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/6878 · Cited by 77
Improved compressed sensing-based cone-beam CT reconstruction using adaptive prior image constraints
Lee, H., Xing, L., Davidi, R., Li, R., Qian, J., & Lee, R. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/8/2287 · Cited by 74
Model-Based Tomographic Reconstruction of Objects Containing Known Components
Stayman, J. W., Otake, Y., Prince, J. L., Khanna, A. J., & Siewerdsen, J. H. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2199763 · Cited by 83
High-quality four-dimensional cone-beam CT by deforming prior images
Wang, J., & Gu, X. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/2/231 · Cited by 75
Image Prediction for Limited-angle Tomography via Deep Learning with Convolutional Neural Network
Zhang, H., Li, L., Qiao, K., Wang, L., Yan, B., Li, L., & Hu, G. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1607.08707 · Cited by 73
Limited-Angle CT Reconstruction via the $L_1/L_2$ Minimization
Wang, C., Tao, M., Nagy, J. G., & Lou, Y. (2021) · SIAM Journal on Imaging Sciences · doi:10.1137/20m1341490 · Cited by 92
Chen, B., Zhang, Z., Sidky, E. Y., Xia, D., & Pan, X. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa8a4b · Cited by 80
Self-citationProximal ADMM for Multi-Channel Image Reconstruction in Spectral X-ray CT
Sawatzky, A., Xu, Q., Schirra, C. O., & Anastasio, M. A. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2321098 · Cited by 73
Dong, X., Niu, T., & Zhu, L. (2014) · Medical Physics · doi:10.1118/1.4870375 · Cited by 73
Ramírez-Giraldo, J. C., Trzasko, J. D., Leng, S., Yu, L., Manduca, A., & McCollough, C. H. (2011) · Medical Physics · doi:10.1118/1.3560878 · Cited by 73
Optimal Transport Driven CycleGAN for Unsupervised Learning in Inverse Problems
Sim, B., Oh, G., Kim, J., Jung, C., & Ye, J. C. (2020) · SIAM Journal on Imaging Sciences · doi:10.1137/20m1317992 · Cited by 86
Improved Compressed Sensing-Based Algorithm for Sparse-View CT Image Reconstruction
Zhu, Z., Wahid, K. A., Babyn, P., Cooper, D. M. L., Pratt, I. V., & Carter, Y. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/185750 · Cited by 72
Temporal resolution improvement in cardiac CT using PICCS (TRI‐PICCS): Performance studies
Tang, J., Hsieh, J., & Chen, G. (2010) · Medical Physics · doi:10.1118/1.3460318 · Cited by 75
Consensus Neural Network for Medical Imaging Denoising with Only Noisy Training Samples
Wu, D., Gong, K., Kim, K., Li, X., & Li, Q. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32251-9_81 · Cited by 72
Iterative CT Reconstruction Using Shearlet-Based Regularization
Vandeghinste, B., Goossens, B., Holen, R. V., Vanhove, C., Pižurica, A., Vandenberghe, S., & Staelens, S. G. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2275994 · Cited by 74
Learning deconvolutional deep neural network for high resolution medical image reconstruction
Liu, H., Xu, J., Wu, Y., Guo, Q., Ibragimov, B., & Xing, L. (2018) · Information Sciences · doi:10.1016/j.ins.2018.08.022 · Cited by 78
A few-view reweighted sparsity hunting (FRESH) method for CT image reconstruction
Chang, M., Li, L., Chen, Z., Xiao, Y., Zhang, L., & Wang, G. (2013) · Journal of X-Ray Science and Technology · doi:10.3233/xst-130370 · Cited by 72
Coded Hyperspectral Imaging and Blind Compressive Sensing
Rajwade, A. V., Kittle, D. S., Tsai, T.-H., Brady, D. J., & Carin, L. (2013) · SIAM Journal on Imaging Sciences · doi:10.1137/120875302 · Cited by 76
Guarantees of total variation minimization for signal recovery
Jian-feng Cai, A., & Xu, W. (2015) · Information and Inference A Journal of the IMA · doi:10.1093/imaiai/iav009 · Cited by 70
Huang, J., Zhang, Y., Ma, J., Zeng, D., Bian, Z., Niu, S., Feng, Q., Liang, Z., & Chen, W. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079709 · Cited by 70
Total variation based gradient descent algorithm for sparse-view photoacoustic image reconstruction
Zhang, Y., Wang, Y., & Zhang, C. (2012) · Ultrasonics · doi:10.1016/j.ultras.2012.08.012 · Cited by 70
Tang, C., Li, J., Wang, L., Li, Z., Jiang, L., Cai, A., Zhang, W., Liang, N., Li, L., & Yan, B. (2019) · Computational and Mathematical Methods in Medicine · doi:10.1155/2019/8639825 · Cited by 78
Effects of sparse sampling schemes on image quality in low‐dose CT
Abbas, S., Lee, T., Shin, S., Lee, R., & Cho, S. (2013) · Medical Physics · doi:10.1118/1.4825096 · Cited by 69
Li, Z., Cai, A., Wang, L., Zhang, W., Tang, C., Li, L., Liang, N., & Yan, B. (2019) · Sensors · doi:10.3390/s19183941 · Cited by 81
Zhuge, X., Palenstijn, W. J., & Batenburg, K. J. (2015) · IEEE Transactions on Image Processing · doi:10.1109/tip.2015.2504869 · Cited by 75
Nonlocal low-rank and sparse matrix decomposition for spectral CT reconstruction
Niu, S., Yu, G., Ma, J., & Wang, J. (2018) · Inverse Problems · doi:10.1088/1361-6420/aa942c · Cited by 73
Imaging Biomarkers in Atherosclerosis Trials
Tardif, J., Lesage, F., Harel, F., Roméo, P., & Pressacco, J. (2011) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.110.962001 · Cited by 73
Wang, D., Wu, Z., & Yu, H. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87589-3_43 · Cited by 88
Regularization strategies in statistical image reconstruction of low‐dose x‐ray CT : A review
Zhang, H., Wang, J., Zeng, D., Tao, X., & Ma, J. (2018) · Medical Physics · doi:10.1002/mp.13123 · Cited by 82
Thériault-Lauzier, P., & Chen, G. (2013) · Medical Physics · doi:10.1118/1.4773866 · Cited by 68
Deep learning-based algorithms for low-dose CT imaging: A review
Chen, H., Li, Q., Zhou, L., & Li, F. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111355 · Cited by 83
Wang, J., Mao, W., & Solberg, T. D. (2010) · Medical Physics · doi:10.1118/1.3495819 · Cited by 64
NeAT: neural adaptive tomography
Rückert, D., Wang, Y., Li, R., Idoughi, R., & Heidrich, W. (2022) · ACM Transactions on Graphics · doi:10.1145/3528223.3530121 · Cited by 137
Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction
Wang, A., Stayman, J. W., Otake, Y., Kleinszig, G., Vogt, S. K., Gallia, G. L., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/4/1005 · Cited by 68
Laminography in the lab: imaging planar objects using a conventional x-ray CT scanner
Fisher, S. L., Holmes, D. J., Jørgensen, J. S., Gajjar, P., Behnsen, J., Lionheart, W. R. B., & Withers, P. J. (2019) · Measurement Science and Technology · doi:10.1088/1361-6501/aafcae · Cited by 62
Advances in 4D radiation therapy for managing respiration: Part I – 4D imaging
Hugo, G. D., & Roşu, M. O. (2012) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2012.06.009 · Cited by 62
Object Specific Trajectory Optimization for Industrial X-ray Computed Tomography
Fischer, A., Lasser, T., Schrapp, M. J., Stephan, J., & Noël, P. B. (2016) · Scientific Reports · doi:10.1038/srep19135 · Cited by 70
Jørgensen, J. S., Kruschel, C., & Lorenz, D. A. (2014) · Inverse Problems in Science and Engineering · doi:10.1080/17415977.2014.986724 · Cited by 62
CT-Scan Denoising Using a Charbonnier Loss Generative Adversarial Network
Gajera, B. V., Kapil, S. R., Ziaei, D., Mangalagiri, J., Siegel, E. L., & Chapman, D. (2021) · IEEE Access · doi:10.1109/access.2021.3087424 · Cited by 70
Anisotropic total variation for limited-angle CT reconstruction
Jin, X., Li, L., Chen, Z., Zhang, L., & Xing, Y. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874180 · Cited by 72
Learning Sub-Sampling and Signal Recovery With Applications in Ultrasound Imaging
Huijben, I. A. M., Veeling, B. S., Janse, K., Mischi, M., & van Sloun, R. J. G. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3008501 · Cited by 82
Real-time 3D analysis during electron tomography using tomviz
Schwartz, J., Harris, C., Pietryga, J., Zheng, H., Kumar, P., Visheratina, A., Kotov, N. A., Major, B., Avery, P., Ercius, P. A., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-32046-0 · Cited by 68
LEARN++: Recurrent Dual-Domain Reconstruction Network for Compressed Sensing CT
Zhang, Y., Chen, H., Xia, W., Chen, Y., Liu, B., Liu, Y., Sun, H., & Zhou, J. (2022) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2022.3222213 · Cited by 72
A limited‐angle intrafraction verification (LIVE) system for radiation therapy
Ren, L., Zhang, Y., & Yin, F.-F. (2014) · Medical Physics · doi:10.1118/1.4861820 · Cited by 60
ProxImaL: efficient image optimization using proximal algorithms
Heide, F., Diamond, S., Nießner, M., Ragan‐Kelley, J., Heidrich, W., & Wetzstein, G. (2016) · ACM Transactions on Graphics · doi:10.1145/2897824.2925875 · Cited by 78
Hämäläinen, K., Kallonen, A., Kolehmainen, V., Lassas, M. J., Niinimäki, K., & Siltanen, S. (2013) · SIAM Journal on Scientific Computing · doi:10.1137/120876277 · Cited by 75
PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction
Stayman, J. W., Dang, H., Ding, Y., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/21/7563 · Cited by 59
Li, L., Chen, Z., Cong, W., & Wang, G. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2359241 · Cited by 59
Wu, J., Melo, L. G. A., Zhu, X., West, M. M., Berejnov, V., Susac, D., Stumper, J., & Hitchcock, A. P. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.01.074 · Cited by 60
Deep learning based spectral CT imaging
Wu, W., Hu, D., Niu, C., Broeke, L. V., Butler, A. P. H., Cao, P., Atlas, J., Chernoglazov, A. I., Vardhanabhuti, V., & Wang, G. (2021) · Neural Networks · doi:10.1016/j.neunet.2021.08.026 · Cited by 68
Sparse angular CT reconstruction using non-local means based iterative-correction POCS
Huang, J., Ma, J., Liu, N., Zhang, H., Bian, Z., Feng, Y., Feng, Q., & Chen, W. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.01.009 · Cited by 59
Digital holographic microtomography for high‐resolution refractive index mapping of live cells
Su, J., Hsu, W., Chou, C., Chang, C., & Sung, K. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200022 · Cited by 58
Hybrid spectral CT reconstruction
Clark, D. P., & Badea, C. T. (2017) · PLoS ONE · doi:10.1371/journal.pone.0180324 · Cited by 60
Brady, D. J., Mrozack, A., MacCabe, K. P., & Llull, P. (2015) · Advances in Optics and Photonics · doi:10.1364/aop.7.000756 · Cited by 63
Artifact reduction in short-scan CBCT by use of optimization-based reconstruction
Zhang, Z., Han, X., Pearson, E. A., Pelizzari, C. A., Sidky, E. Y., & Pan, X. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/9/3387 · Cited by 61
Self-citationSparseBeads data: benchmarking sparsity-regularized computed tomography
Jørgensen, J. S., Coban, S. B., Lionheart, W. R. B., McDonald, S. A., & Withers, P. J. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa8c29 · Cited by 59
DuDoTrans: Dual-Domain Transformer for Sparse-View CT Reconstruction
Wang, C., Shang, K., Zhang, H., Li, Q., & Zhou, S. K. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-17247-2_9 · Cited by 99
Recent Advances in X-ray Cone-beam Computed Laminography
O’Brien, N. S., Boardman, R., Sinclair, I., & Blumensath, T. (2016) · Journal of X-Ray Science and Technology · doi:10.3233/xst-160581 · Cited by 76
Two stage residual CNN for texture denoising and structure enhancement on low dose CT image
Huang, L., Jiang, H., Li, S., Bai, Z., & Zhang, J. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.105115 · Cited by 60
Sparse-view CT reconstruction based on multi-level wavelet convolution neural network
Lee, M., Kim, H., & Kim, H.-J. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.11.021 · Cited by 63
Compressed sampling strategies for tomography
Kaganovsky, Y., Li, D., Holmgren, A. D., Jeon, H., MacCabe, K. P., Politte, D. G., O’Sullivan, J. A., Carin, L., & Brady, D. J. (2014) · Journal of the Optical Society of America A · doi:10.1364/josaa.31.001369 · Cited by 65
Li, R., Li, Q., Wang, H., Li, S., Zhao, J., Qiang, Y., & Wang, L. (2022) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2022.3207351 · Cited by 68
Gao, Y., Bian, Z., Huang, J., Zhang, Y., Niu, S., Feng, Q., Chen, W., Liang, Z., & Ma, J. (2014) · Optics Express · doi:10.1364/oe.22.015190 · Cited by 64
Few‐view image reconstruction combining total variation and a high‐order norm
Zhang, Y., Zhang, W., Chen, H., Yang, M., Li, T., & Zhou, J. (2013) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22058 · Cited by 55
Dynamic Iterative Reconstruction for Interventional 4-D C-Arm CT Perfusion Imaging
Manhart, M. T., Kowarschik, M., Fieselmann, A., Deuerling‐Zheng, Y., Royalty, K., Maier, A., & Joachim Hornegger, A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2257178 · Cited by 55
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.