Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Items 601–700 of 1,000
Lohvithee, M., Sun, W., Chrétien, S., & Soleimani, M. (2021) · Sensors · doi:10.3390/s21020591 · Cited by 17
Rahim, T., Novamizanti, L., Ramatryana, I. N. A., & Shin, S. Y. (2021) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2021.101927 · Cited by 18
Adapted fan-beam volume reconstruction for stationary digital breast tomosynthesis
Wu, G., Inscoe, C. R., Calliste, J., Lee, Y. Z., Zhou, O. Z., & Lü, J. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2081931 · Cited by 17
Chen, M., Cao, K., Zheng, Y., & Siochi, R. A. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2231694 · Cited by 17
Kayal, E. B., Kandasamy, D., Khare, K., Alampally, J. T., Bakhshi, S., Sharma, R., & Mehndiratta, A. (2017) · Medical Physics · doi:10.1002/mp.12520 · Cited by 19
Reconstruction of 3D X-ray CT images from reduced sampling by a scaled gradient projection algorithm
Piccolomini, E. L., Coli, V. L., Morotti, E., & Zanni, L. (2017) · Computational Optimization and Applications · doi:10.1007/s10589-017-9961-2 · Cited by 17
Tseng, H. W., Vedantham, S., & Karellas, A. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.04.020 · Cited by 17
Liang, Z., Wang, Q., Xia, C., Chen, Z., Xu, M., Liang, G., Zhang, Y., Ye, C., Zhang, Y., Yu, X., et al. (2024) · The Spine Journal · doi:10.1016/j.spinee.2024.03.019 · Cited by 19
Peterlík, I., Strzelecki, A., Lehmann, M., Messmer, P., Munro, P., Paysan, P., Plamondon, M., & Seghers, D. (2021) · Medical Physics · doi:10.1002/mp.15236 · Cited by 16
Kim, B., Divel, S. E., Pelc, N. J., & Baek, J. (2022) · IEEE Access · doi:10.1109/access.2022.3198948 · Cited by 16
DFSNE-Net: Deviant feature sensitive noise estimate network for low-dose CT denoising
Liu, J., Jiang, H., Ning, F., Li, M., & Pang, W. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106061 · Cited by 16
Bayat, F., Ruan, D., Miften, M. M., & Altunbas, C. (2023) · Medical Physics · doi:10.1002/mp.16681 · Cited by 16
Hein, D., Holmin, S., Szczykutowicz, T. P., Maltz, J. S., Danielsson, M. E., Wang, G., & Persson, M. (2024) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2024.3410092 · Cited by 24
Residual encoder-decoder based architecture for medical image denoising
Ferdi, A., Benierbah, S., & Nakib, A. (2024) · Multimedia Tools and Applications · doi:10.1007/s11042-024-20175-1 · Cited by 22
Geometry-Aware Attenuation Learning for Sparse-View CBCT Reconstruction
Liu, Z. Q., Fang, Y., Li, C., Wu, H. C., Liu, Y., Shen, D. G., & Cui, Z. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3473970 · Cited by 38
Biguri, A., Sadakane, T., Lindroos, R., Liu, Y., Landman, M. S., Du, Y., Lohvithee, M., Kaser, S., Hatamikia, S., Bryll, R., et al. (2025) · Engineering Research Express · doi:10.1088/2631-8695/adbb3a · Cited by 32
Meng, B., Lee, H., Xing, L., & Fahimian, B. (2012) · Medical Physics · doi:10.1118/1.4769421 · Cited by 16
Cabello, J., Torres-Espallardo, I., Gillam, J. E., & Rafecas, M. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2278121 · Cited by 16
Image reconstruction by an alternating minimisation
Lu, X., Sun, Y., & Yuan, Y. (2010) · Neurocomputing · doi:10.1016/j.neucom.2010.08.003 · Cited by 16
Iterative CT reconstruction via minimizing adaptively reweighted total variation
Zhu, L., Niu, T., & Petrongolo, M. (2014) · Journal of X-Ray Science and Technology · doi:10.3233/xst-140421 · Cited by 16
Cai, A., Wang, L., Yan, B., Li, L., Zhang, H., & Hu, G. (2015) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2015.06.004 · Cited by 17
Qi, H., Chen, Z., Wu, S., Xu, Y. X., & Zhou, L. (2016) · Physica Medica · doi:10.1016/j.ejmp.2016.07.310 · Cited by 16
Lin, Q., Andrew, M. G., Thompson, W., Blunt, M. J., & Bijeljic, B. (2018) · Advances in Water Resources · doi:10.1016/j.advwatres.2018.03.007 · Cited by 16
An improved algebraic reconstruction technique for reconstructing tomographic gamma scanning image
Zheng, H., Tuo, X., Peng, S., Shi, R., Li, H., He, A., Li, Z., & Han, Q. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.07.095 · Cited by 16
Image gradient L0-norm based PICCS for swinging multi-source CT reconstruction
Yu, H., Wu, W., Chen, P., Gong, C., Jiang, J., Wang, S., Liu, F., & Yu, H. (2019) · Optics Express · doi:10.1364/oe.27.005264 · Cited by 16
Lv, D., Zhou, Q., Choi, J. K., Li, J., & Zhang, X. (2019) · Inverse Problems and Imaging · doi:10.3934/ipi.2019066 · Cited by 16
Yin, Z., Xia, K., Wang, S., He, Z., Zhang, J., & Zu, B. (2022) · The Visual Computer · doi:10.1007/s00371-022-02599-8 · Cited by 19
CT Image Reconstruction from Sparse Projections Using Adaptive TpV Regularization
Qi, H., Chen, Z., & Zhou, L. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/354869 · Cited by 16
A novel scheme to design the filter for CT reconstruction using FBP algorithm
Shi, H., & Luo, S. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-50 · Cited by 16
Volume-of-change cone-beam CT for image-guided surgery
Lee, J., Stayman, J. W., Otake, Y., Schäfer, S., Zbijewski, W. B., Khanna, A. J., Prince, J. L., & Siewerdsen, J. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/15/4969 · Cited by 16
X‐ray computed tomography using curvelet sparse regularization
Wieczorek, M., Frikel, J., Vogel, J., Eggl, E., Kopp, F. K., Noël, P. B., Pfeiffer, F., Demaret, L., & Lasser, T. (2015) · Medical Physics · doi:10.1118/1.4914368 · Cited by 16
Li, G., Luo, S., Yan, Y., & Gu, N. (2015) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-14-s1-s15 · Cited by 16
Abir, M., Islam, F. F., Wachs, D. M., & Lee, H. (2015) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-015-4542-2 · Cited by 16
Simultaneous deblurring and iterative reconstruction of CBCT for image guided brain radiosurgery
Hashemi, S., Song, W. Y., Sahgal, A., Lee, Y. K., Huynh, C., Grouza, V., Nordström, H., Eriksson, M., Dorenlot, A., Régis, J. M., et al. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5ed2 · Cited by 16
Simulation-based artifact correction (SBAC) for metrological computed tomography
Maier, J., Leinweber, C., Sawall, S., Stoschus, H., Ballach, F., Müller, T., Hammer, M., Christoph, R., & Kachelrieß, M. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa666e · Cited by 16
Sparsity Order Estimation From a Single Compressed Observation Vector
Semper, S., Roemer, F., Hotz, T., & Galdo, G. D. (2018) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2018.2841867 · Cited by 18
Living Near the Edge: A Lower-Bound on the Phase Transition of Total Variation Minimization
Daei, S., Haddadi, F., & Amini, A. (2019) · IEEE Transactions on Information Theory · doi:10.1109/tit.2019.2940673 · Cited by 16
A Preliminary Study on Projection Denoising for Low-dose CT Imaging Using Modified Dual-Domain U-net
Feng, Z., Li, Z., Cai, A., Li, L., Yan, B., & Tong, L. (2020) · International Conference on Artificial Intelligence and Big Data (ICAIBD) · doi:10.1109/icaibd49809.2020.9137456 · Cited by 16
Liu, J., Zhang, T., Kang, Y., Wang, Y., Zhang, Y., Hu, D., & Chen, Y. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104868 · Cited by 17
Ylisiurua, S., Sipola, A., Nieminen, M. T., & Brix, M. A. K. (2023) · Physica Medica · doi:10.1016/j.ejmp.2023.103184 · Cited by 15
Prior frequency guided diffusion model for limited angle (LA)-CBCT reconstruction
Xie, J., Shao, H., Li, Y., & Zhang, Y. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad580d · Cited by 17
Ehmsen, M. L., Poulsen, P. R., Toftegaard, J., Hoffmann, L., Hansen, D. C., & Sørensen, T. S. (2014) · Acta Oncologica · doi:10.3109/0284186x.2014.927585 · Cited by 15
Accurate Sparse-Projection Image Reconstruction via Nonlocal TV Regularization
Zhang, Y., Zhang, W., & Zhou, J. (2014) · The Scientific World JOURNAL · doi:10.1155/2014/458496 · Cited by 15
Choi, K., Li, R., Nam, H., & Xing, L. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/12/3097 · Cited by 15
Noise texture and signal detectability in propagation‐based x‐ray phase‐contrast tomography
Chou, C., & Anastasio, M. A. (2009) · Medical Physics · doi:10.1118/1.3267548 · Cited by 15
Xia, C., Su, C., Cao, J., & Li, P. (2016) · Chinese Journal of Chemical Engineering · doi:10.1016/j.cjche.2016.01.017 · Cited by 15
CT reconstruction from few-views with anisotropic edge-guided total variance
Rong, J., Liu, W., Gao, P., Liao, Q., Jiao, C., Ma, J., & Lu, H. (2016) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2016.02.068 · Cited by 15
Dekker, K. H., Battista, J. J., & Jordan, K. J. (2017) · Medical Physics · doi:10.1002/mp.12635 · Cited by 15
Reduced anatomical clutter in digital breast tomosynthesis with statistical iterative reconstruction
Garrett, J. W., Li, Y., Li, K., & Chen, G. (2018) · Medical Physics · doi:10.1002/mp.12864 · Cited by 17
Zhang, X., Uneri, A., Stayman, J. W., Zygourakis, C. C., Lo, S.-F. L., Theodore, N., & Siewerdsen, J. H. (2019) · Medical Physics · doi:10.1002/mp.13652 · Cited by 15
Mahmoudi, G., Fouladi, M. R., Ay, M. R., Rahmim, A., & Ghadiri, H. (2019) · Journal of Instrumentation · doi:10.1088/1748-0221/14/08/p08023 · Cited by 15
Zhang, Z., Epel, B., Chen, B., Xia, D., Sidky, E. Y., Qiao, Z., Halpern, H. J., & Pan, X. (2023) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2023.107432 · Cited by 15
Self-citationKim, H., Li, R., Lee, R., Goldstein, T., Boyd, S., Candès, E. J., & Xing, L. (2012) · Medical Physics · doi:10.1118/1.4729717 · Cited by 15
Improved total variation minimization method for few-view computed tomography image reconstruction
Hu, Z., & Zheng, H. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-70 · Cited by 15
Noise Removal of Low-Dose CT Images Using Modified Smooth Patch Ordering
Wang, Y., Shao, Y., Zhang, Q., Liu, Y., Chen, Y., Chen, W., & Gui, Z. (2017) · IEEE Access · doi:10.1109/access.2017.2777440 · Cited by 15
Sampling limits for electron tomography with sparsity-exploiting reconstructions
Jiang, Y., Padgett, E., Hovden, R., & Muller, D. A. (2017) · Ultramicroscopy · doi:10.1016/j.ultramic.2017.12.010 · Cited by 15
Choi, K., Lim, J. S., & Kim, S. (2018) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2293420 · Cited by 17
Park, C. J., Kim, K. W., Lee, H., Kim, M., & Kim, J. (2018) · Korean Journal of Radiology · doi:10.3348/kjr.2018.19.5.957 · Cited by 16
Sparse dynamic tomography: a shearlet-based approach for iodine perfusion in plant stems
Bubba, T. A., Heikkilä, T., Help, H., Huotari, S., Salmon, Y., & Siltanen, S. (2020) · Inverse Problems · doi:10.1088/1361-6420/ab9c15 · Cited by 15
EM+TV Based Reconstruction for Cone-Beam CT with Reduced Radiation
Yan, M., Chen, J., Vese, L. A., Villasenor, J. D., Bui, A. A. T., & Cong, J. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-24028-7_1 · Cited by 15
GAN2GAN: Generative Noise Learning for Blind Denoising with Single Noisy ImagesPreprint
Cha, S., Park, T., Kim, B., Baek, J., & Moon, T. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1905.10488 · Cited by 45
Jiang, Z., Zhang, Z., Chang, Y., Ge, Y., Yin, F.-F., & Ren, L. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-114 · Cited by 17
Does ITZ Influence Moisture Transport in Concrete?
Dalton, L. E., LaManna, J. M., Jones, S. Z., & Pour‐Ghaz, M. (2022) · Transport in Porous Media · doi:10.1007/s11242-022-01826-z · Cited by 14
Learning low‐dose CT degradation from unpaired data with flow‐based model
Liu, X., Liang, X., Deng, L., Tan, S., & Xie, Y. (2022) · Medical Physics · doi:10.1002/mp.15886 · Cited by 18
Liu, H., Liao, P., Chen, H., & Zhang, Y. (2022) · Biomedical Optics Express · doi:10.1364/boe.471340 · Cited by 14
Jiang, Z., Polf, J., Barajas, C., Gobbert, M. K., & Ren, L. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/acbf9a · Cited by 14
A novel off‐axis scanning method for an enlarged ellipse cone‐beam computed tomography field of view
Li, T., Li, X., Yang, Y., Heron, D. E., & Huq, M. S. (2010) · Medical Physics · doi:10.1118/1.3514130 · Cited by 14
Reims, N., Schoen, T., Boehnel, M., Sukowski, F., & Firsching, M. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2062002 · Cited by 14
Mueller, K., Schwemmer, C., Joachim Hornegger, A., Zheng, Y., Wang, Y., Lauritsch, G., Rohkohl, C., Maier, A., Schultz, C. J., & Fahrig, R. (2013) · Medical Physics · doi:10.1118/1.4789593 · Cited by 14
Huang, H., & Shih, Y.-Y. (2014) · BioMed Research International · doi:10.1155/2014/365812 · Cited by 14
A Parametric Level-Set Method for Partially Discrete Tomography
Kadu, A. A., van Leeuwen, T., & Batenburg, K. J. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-66272-5_11 · Cited by 14
Hou, X., Teng, Y., Kang, Y., & Qi, S. (2017) · Medical Physics · doi:10.1002/mp.12692 · Cited by 14
Wang, Y., & Qi, Z. (2018) · Journal of X-Ray Science and Technology · doi:10.3233/xst-180412 · Cited by 14
Zhang, W., Wang, L., Li, L., Niu, T., Li, Z., Liang, N., Xue, Y., Yan, B., & Hu, G. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab5faf · Cited by 14
Lee, H., Park, J., Choi, Y., Park, K. R., Min, B. J., & Lee, I. J. (2021) · Scientific Reports · doi:10.1038/s41598-021-83266-1 · Cited by 13
A Model-Based Optimization Framework for Iterative Digital Breast Tomosynthesis Image Reconstruction
Piccolomini, E. L., & Morotti, E. (2021) · Journal of Imaging · doi:10.3390/jimaging7020036 · Cited by 14
A balanced total-variation-Chambolle-Pock algorithm for EPR imaging
Qiao, Z., Redler, G., Epel, B., & Halpern, H. J. (2021) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2021.107009 · Cited by 14
Dai, Q., Zhang, H., & Zhang, B. (2021) · Remote Sensing · doi:10.3390/rs13132514 · Cited by 15
Gomi, T., Kijima, Y., Kobayashi, T., & Koibuchi, Y. (2022) · Diagnostics · doi:10.3390/diagnostics12020495 · Cited by 14
Tseng, H. W., Karellas, A., & Vedantham, S. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac5fe1 · Cited by 14
Jiang, Z., Chang, Y., Zhang, Z., Yin, F.-F., & Ren, L. (2022) · Medical Physics · doi:10.1002/mp.15806 · Cited by 14
Self‐supervised denoising of projection data for low‐dose cone‐beam CT
Choi, K., Kim, S. H., & Kim, S. (2023) · Medical Physics · doi:10.1002/mp.16421 · Cited by 20
A majorize-minimize memory gradient algorithm applied to X-ray tomography
Chouzenoux, É., Zolyniak, F., Gouillart, E., & Talbot, H. (2013) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2013.6738209 · Cited by 15
Smoothed l0 Norm Regularization for Sparse-View X-Ray CT Reconstruction
Li, M., Zhang, C., Peng, C., Guan, Y., Xu, P., Sun, M., & Zheng, J. (2016) · BioMed Research International · doi:10.1155/2016/2180457 · Cited by 14
Lee, H., Fahimian, B., & Xing, L. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5913 · Cited by 14
Luo, S., Shen, T., Sun, Y., Li, J., Li, G., & Tang, X. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aab46f · Cited by 14
Ultrasonic Wave-Speed Diffraction Tomography With Undersampled Data Using Virtual Transducers
Shi, F., & Huthwaite, P. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2828644 · Cited by 14
On-the-Fly Machine Learning for Improving Image Resolution in Tomography
Hendriksen, A. A., Pelt, D. M., Palenstijn, W. J., Coban, S. B., & Batenburg, K. J. (2019) · Applied Sciences · doi:10.3390/app9122445 · Cited by 14
Chen, W., Shao, Y., Jia, L., Wang, Y., Zhang, Q., Shang, Y., Liu, Y., Chen, Y., Liu, Y., & Gui, Z. (2019) · IEEE Access · doi:10.1109/access.2019.2932754 · Cited by 14
Shi, Z., Li, J., Li, H., Hu, Q., & Cao, Q. (2019) · IEEE Access · doi:10.1109/access.2019.2934508 · Cited by 15
Low-dose dual energy CT image reconstruction using non-local deep image prior
Gong, K., Kim, K., Wu, D., Kalra, M. K., & Li, Q. (2019) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nss/mic42101.2019.9060001 · Cited by 14
Learnable Multi-scale Fourier Interpolation for Sparse View CT Image Reconstruction
Ding, Q., Ji, H., Gao, H., & Zhang, X. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87231-1_28 · Cited by 14
An Accelerated Smoothing Gradient Method for Nonconvex Nonsmooth Minimization in Image Processing
Wang, W., & Chen, Y. (2021) · Journal of Scientific Computing · doi:10.1007/s10915-021-01677-8 · Cited by 16
Using compressive sensing to recover images from PET scanners with partial detector rings
Valiollahzadeh, S. M., Clark, J. W., & Mawlawi, O. R. (2014) · Medical Physics · doi:10.1118/1.4903291 · Cited by 14
Pan, S., Peng, J., Gao, Y., Lo, S.-Y., Luan, T., Li, J., Wang, T., Chang, C., Tian, Z., & Yang, X. (2025) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2025.3556402 · Cited by 19
Binary Tomography Reconstructions With Stochastic Level-Set Methods
Wang, L., Sixou, B., & Peyrin, F. (2014) · IEEE Signal Processing Letters · doi:10.1109/lsp.2014.2375511 · Cited by 13
Can real-time RGBD enhance intraoperative Cone-Beam CT?
Fotouhi, J., Fuerst, B., Wein, W., & Navab, N. (2017) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-017-1572-y · Cited by 13
Sparse-View CT Reconstruction Based on a Hybrid Domain Model with Multi-Level Wavelet Transform
Bai, J., Liu, Y., & Yang, H. (2022) · Sensors · doi:10.3390/s22093228 · Cited by 13
A total variation prior unrolling approach for computed tomography reconstruction
Zhang, P., Ren, S., Liu, Y., Gui, Z., Shangguan, H., Wang, Y., Shu, H., & Chen, Y. (2023) · Medical Physics · doi:10.1002/mp.16307 · Cited by 13
Sun, T., Yu, M., Yu, L., Deng, D., Chen, M., Lin, H., Chen, S., Chang, C., & Chen, X. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3314617 · Cited by 13
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.