Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Items 301–400 of 1,000
Accurate multipixel phase measurement with classical-light interferometry
Singh, M., Khare, K., Jha, A. K., Prabhakar, S., & Singh, R. P. (2015) · Physical Review A · doi:10.1103/physreva.91.021802 · Cited by 37
Optimization-based image reconstruction with artifact reduction in C-arm CBCT
Xia, D., Langan, D. A., Solomon, S. B., Zhang, Z., Chen, B., Lai, H., Sidky, E. Y., & Pan, X. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/20/7300 · Cited by 43
Self-citationHigh quality 4D cone-beam CT reconstruction using motion-compensated total variation regularization
Zhang, H., Ma, J., Bian, Z., Zeng, D., Feng, Q., & Chen, W. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6128 · Cited by 38
Denoising Low-Dose CT Images Using Multiframe Blind Source Separation and Block Matching Filter
Hasan, A. M., Melli, A., Wahid, K. A., & Babyn, P. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2810221 · Cited by 41
Probabilistic self‐learning framework for low‐dose CT denoising
Bai, T., Wang, B., Nguyen, D., & Jiang, S. B. (2021) · Medical Physics · doi:10.1002/mp.14796 · Cited by 39
Arbitrarily large tomography with iterative algorithms on multiple GPUs using the TIGRE toolbox
Biguri, A., Lindroos, R., Bryll, R., Towsyfyan, H., Deyhle, H., Harrane, I. E. K., Boardman, R., Mavrogordato, M., Dosanjh, M. K., Hancock, S., et al. (2020) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2020.07.004 · Cited by 45
Iterative material decomposition for spectral CT using self-supervised Noise2Noise prior
Fang, W., Wu, D., Kim, K., Kalra, M. K., Singh, R., Li, L., & Li, Q. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac0afd · Cited by 38
Huang, Z., Chen, Z., Quan, G., Du, Y., Yang, Y., Liu, X., Zheng, H., Liang, D., & Hu, Z. (2022) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2022.3150322 · Cited by 42
Mory, C., Auvray, V., Zhang, B., Graß, M., Schäfer, D., Chen, S. J., Carroll, J. D., Rit, S., Peyrin, F., Douek, P., et al. (2014) · Medical Physics · doi:10.1118/1.4860215 · Cited by 45
Edge Information Diffusion-Based Reconstruction for Cone Beam Computed Laminography
Zhao, Y., Xu, J., Li, H., & Zhang, P. (2018) · IEEE Transactions on Image Processing · doi:10.1109/tip.2018.2845098 · Cited by 43
Compressive Sensing Image Sensors-Hardware Implementation
Dadkhah, M., Deen, M. J., & Shirani, S. (2013) · Sensors · doi:10.3390/s130404961 · Cited by 37
Few‐view cone‐beam CT reconstruction with deformed prior image
Zhang, H., Ouyang, L., Huang, J., Ma, J., Chen, W., & Wang, J. (2014) · Medical Physics · doi:10.1118/1.4901265 · Cited by 37
Statistical image reconstruction from limited projection data with intensity priors
Rashed, E. A., & Kudo, H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/7/2039 · Cited by 37
Niu, S., Zhang, S., Huang, J., Bian, Z., Chen, W., Yu, G., Liang, Z., & Ma, J. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.01.090 · Cited by 37
High‐quality initial image‐guided 4D CBCT reconstruction
Zhi, S., Kachelrieß, M., & Mou, X. (2020) · Medical Physics · doi:10.1002/mp.14060 · Cited by 37
Cone-beam computed tomography based on truncated adaptive-weight total variation
Liu, Y., Liu, Y., Zhang, P., Yan, R., Wang, L., Liu, W., & Gui, Z. (2022) · NDT & E International · doi:10.1016/j.ndteint.2022.102755 · Cited by 38
Zhang, Y., Jiang, Z., Zhang, Y., & Ren, L. (2024) · Medical Physics · doi:10.1002/mp.17269 · Cited by 36
Low‐dose CT reconstruction using spatially encoded nonlocal penalty
Kim, K., Fakhri, G. E., & Li, Q. (2017) · Medical Physics · doi:10.1002/mp.12523 · Cited by 39
Sinogram interpolation for sparse-view micro-CT with deep learning neural network
Cao, G., Vekhande, S., & Xu, D. (2019) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2512979 · Cited by 52
Improved Material Decomposition With a Two-Step Regularization for Spectral CT
Wu, W., Chen, P., Vardhanabhuti, V., Wu, W., & Yu, H. (2019) · IEEE Access · doi:10.1109/access.2019.2950427 · Cited by 35
Learned Full-Sampling Reconstruction From Incomplete Data
Cheng, W., Wang, Y., Li, H., & Duan, Y. (2020) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2020.2996751 · Cited by 38
A new regularization technique for limited-view sound-speed imaging
Huthwaite, P., Zwiebel, A. A., & Simonetti, F. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2602 · Cited by 36
Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
Cheng, C., Ching, Y.-T., Ko, P.-H., & Hwu, Y. (2018) · Scientific Reports · doi:10.1038/s41598-018-28149-8 · Cited by 36
Zhang, Z., Liu, J., Yang, D., Kamilov, U. S., & Hugo, G. D. (2022) · Medical Physics · doi:10.1002/mp.16103 · Cited by 39
Accelerated statistical reconstruction for C‐arm cone‐beam CT using Nesterov's method
Wang, A., Stayman, J. W., Otake, Y., Vogt, S. K., Kleinszig, G., & Siewerdsen, J. H. (2015) · Medical Physics · doi:10.1118/1.4914378 · Cited by 35
Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT
Wang, A., Stayman, J. W., Otake, Y., Vogt, S. K., Kleinszig, G., Khanna, A. J., Gallia, G. L., & Siewerdsen, J. H. (2014) · Medical Physics · doi:10.1118/1.4884039 · Cited by 35
Swinging multi-source industrial CT systems for aperiodic dynamic imaging
Wu, W., Yu, H., Gong, C., & Liu, F. (2017) · Optics Express · doi:10.1364/oe.25.024215 · Cited by 34
Few‐view CT reconstruction with group‐sparsity regularization
Bao, P., Zhou, J., & Zhang, Y. (2018) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3101 · Cited by 35
Spatial-spectral cube matching frame for spectral CT reconstruction
Wu, W., Zhang, Y., Wang, Q., Liu, F., Luo, F., & Yu, H. (2018) · Inverse Problems · doi:10.1088/1361-6420/aad67b · Cited by 39
Gong, C., Zeng, L., & Wang, C. (2019) · Applied Mathematical Modelling · doi:10.1016/j.apm.2019.05.020 · Cited by 38
CT Image Reconstruction by Spatial-Radon Domain Data-Driven Tight Frame Regularization
Zhan, R., & Dong, B. (2016) · SIAM Journal on Imaging Sciences · doi:10.1137/16m105928x · Cited by 35
Zhang, C., Zhang, T., Li, M., Peng, C., Liu, Z., & Zheng, J. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0193-y · Cited by 35
A General-Thresholding Solution for l p (0 <; p <; 1) Regularized CT Reconstruction
Miao, C., & Yu, H. (2015) · IEEE Transactions on Image Processing · doi:10.1109/tip.2015.2468175 · Cited by 38
Wolf, P. A., Jørgensen, J. S., Schmidt, T. G., & Sidky, E. Y. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5629 · Cited by 37
Self-citationXu, Q., Sidky, E. Y., Pan, X., Stampanoni, M., Modregger, P., & Anastasio, M. A. (2012) · Optics Express · doi:10.1364/oe.20.010724 · Cited by 38
Self-citationA Novel Fractional-Order Differentiation Model for Low-Dose CT Image Processing
Wang, Y., Shao, Y., Gui, Z., Zhang, Q., Yao, L., & Liu, Y. (2016) · IEEE Access · doi:10.1109/access.2016.2633272 · Cited by 34
Singh, M., & Khare, K. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2018.1426798 · Cited by 34
Limited angle tomography for transmission X-ray microscopy using deep learning
Huang, Y., Wang, S., Guan, Y., & Maier, A. (2020) · Journal of Synchrotron Radiation · doi:10.1107/s160057752000017x · Cited by 37
REDAEP: Robust and Enhanced Denoising Autoencoding Prior for Sparse-View CT Reconstruction
Zhang, F., Zhang, M., Qin, B., Zhang, Y., Xu, Z., Liang, D., & Liu, Q. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.2989634 · Cited by 36
An End-to-End Deep Network for Reconstructing CT Images Directly From Sparse Sinograms
Wang, W., Xia, X., He, C., Ren, Z., Lu, J. J., Wang, T., & Lei, B. (2020) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2020.3039385 · Cited by 37
A Dual-Domain CNN-Based Network for CT Reconstruction
Jiao, F., Gui, Z., Li, K., Shangguan, H., Wang, Y., Liu, Y., & Zhang, P. (2021) · IEEE Access · doi:10.1109/access.2021.3079323 · Cited by 34
Edge guided image reconstruction in linear scan CT by weighted alternating direction TV minimization
Cai, A., Wang, L., Zhang, H., Yan, B., Li, L., Xi, X., & Li, J. (2014) · Journal of X-Ray Science and Technology · doi:10.3233/xst-140429 · Cited by 34
Image reconstruction from few views by ℓ0-norm optimization
Sun, Y., & Tao, J. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/7/078703 · Cited by 34
Median prior constrained TV algorithm for sparse view low-dose CT reconstruction
Liu, Y., Shangguan, H., Zhang, Q., Zhu, H., Shu, H., & Gui, Z. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.03.003 · Cited by 34
Easy implementation of advanced tomography algorithms using the ASTRA toolbox with Spot operators
Bleichrodt, F., van Leeuwen, T., Palenstijn, W. J., van Aarle, W., Sijbers, J., & Batenburg, K. J. (2015) · Numerical Algorithms · doi:10.1007/s11075-015-0016-4 · Cited by 35
Brehm, M., Sawall, S., Maier, J., Sauppe, S., & Kachelrieß, M. (2015) · Medical Physics · doi:10.1118/1.4916083 · Cited by 34
United Iterative Reconstruction for Spectral Computed Tomography
Xi, Y., Chen, Y., Tang, R., Sun, J., & Zhao, J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2339497 · Cited by 33
Zhang, R., Ye, D. H., Pal, D., Thibault, J., Sauer, K. D., & Bouman, C. A. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2582042 · Cited by 35
Compressed sensing for STEM tomography
Donati, L., Nilchian, M., Trépout, S., Messaoudi, C., Marco, S., & Unser, M. A. (2017) · Ultramicroscopy · doi:10.1016/j.ultramic.2017.04.003 · Cited by 33
Deep Residual Learning for Model-Based Iterative CT Reconstruction Using Plug-and-Play Framework
Ye, D. H., Srivastava, S., Thibault, J., Sauer, K. D., & Bouman, C. A. (2018) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2018.8461408 · Cited by 43
Deep Learning Based Image Reconstruction for Diffuse Optical Tomography
Yedder, H. B., BenTaieb, A., Shokoufi, M., Zahiremami, A., Golnaraghi, F., & Hamarneh, G. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-00129-2_13 · Cited by 34
Speed-of-Sound Imaging Based on Reflector Delineation
Sanabria, S. J., Rominger, M. B., & Göksel, O. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2881302 · Cited by 33
Robust multimaterial decomposition of spectral CT using convolutional neural networks
Chen, Z., & Li, L. (2019) · Optical Engineering · doi:10.1117/1.oe.58.1.013104 · Cited by 36
TomoFluid: Reconstructing Dynamic Fluid From Sparse View Videos
Zang, G., Idoughi, R., Wang, C., Bennett, A., Du, J., Skeen, S. A., Roberts, W. L., Wonka, P., & Heidrich, W. (2020) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr42600.2020.00194 · Cited by 47
High-speed rotating device for X-ray tomography with 10 ms temporal resolution
Mashita, R., Yashiro, W., Kaneko, D., Bito, Y., & Kishimoto, H. (2020) · Journal of Synchrotron Radiation · doi:10.1107/s1600577520014666 · Cited by 35
Livermore tomography tools: Accurate, fast, and flexible software for tomographic science
Champley, K., Willey, T. M., Kim, H., Bond, K., Glenn, S., Smith, J. A., Kallman, J. S., Brown, W. D., Seetho, I. M., Keene, L. T., et al. (2021) · NDT & E International · doi:10.1016/j.ndteint.2021.102595 · Cited by 36
Dual-domain sparse-view CT reconstruction with Transformers
Shi, C., Xiao, Y., & Chen, Z. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.07.001 · Cited by 36
Optimization for limited angle tomography in medical image processing
Lu, X., Sun, Y., & Yuan, Y. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2010.12.016 · Cited by 33
Li, Y., Chen, Y., Hu, Y., Oukili, A., Luo, L., Chen, W., & Toumoulin, C. (2011) · Journal of the Optical Society of America A · doi:10.1364/josaa.29.000153 · Cited by 33
Adaptive‐weighted high order TV algorithm for sparse‐view CT reconstruction
Xi, Y., Zhou, P., Yu, H., Zhang, T., Zhang, L., Qiao, Z., & Liu, F. (2023) · Medical Physics · doi:10.1002/mp.16371 · Cited by 36
Multiscale drainage dynamics with Haines jumps monitored by stroboscopic 4D X-ray microscopy
Tekseth, K. R., Mirzaei, F., Lukić, B., Chattopadhyay, B., & Breiby, D. W. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2305890120 · Cited by 32
Scout-view assisted interior micro-CT
Sharma, K. S., Holzner, C., Vasilescu, D. M., Jin, X., Narayanan, S., Agah, M., Hoffman, E. A., Yu, H., & Wang, G. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/12/4297 · Cited by 35
Spatial-temporal total variation regularization (STTVR) for 4D-CT reconstruction
Wu, H., Maier, A., Fahrig, R., & Joachim Hornegger, A. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.911162 · Cited by 32
Zhang, H., Wang, L., Yan, B., Li, L., Cai, A., & Hu, G. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149899 · Cited by 32
Split-Bregman-based sparse-view CT reconstruction
Vandeghinste, B., Goossens, B., Beenhouwer, J. D., Pižurica, A., Philips, W. R., Vandenberghe, S., & Staelens, S. G. (2011) · Ghent University Academic Bibliography (Ghent University) · Cited by 32
A feature refinement approach for statistical interior CT reconstruction
Hu, Z., Zhang, Y., Liu, J., Ma, J., Zheng, H., & Liang, D. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/14/5311 · Cited by 32
Block-sparse beamforming for spatially extended sources in a Bayesian formulation
Xenaki, A., Fernández-Grande, E., & Gerstoft, P. (2016) · The Journal of the Acoustical Society of America · doi:10.1121/1.4962325 · Cited by 34
Wan, H., Dong, G.-S., & Luo, Y. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.107685 · Cited by 33
Zhang, H., Wang, L., Li, L., Cai, A., Hu, G., & Yan, B. (2016) · Medical Physics · doi:10.1118/1.4950722 · Cited by 35
Millisecond-order X-ray phase tomography with compressed sensing
Yashiro, W., Ueda, R., Kajiwara, K., Noda, D., & Kudo, H. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.112503 · Cited by 34
Thériault-Lauzier, P., & Chen, G. (2012) · Medical Physics · doi:10.1118/1.4748323 · Cited by 31
Wu, D., Li, L., & Zhang, L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/12/4047 · Cited by 31
Niu, T., Ye, X., Fruhauf, Q., Petrongolo, M., & Zhu, L. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/7/1801 · Cited by 31
Low-Dose CT Image Denoising Using Cycle-Consistent Adversarial Networks
Li, Z., Huang, J., Yu, L., Chi, Y., & Jin, M. (2019) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nss/mic42101.2019.9059965 · Cited by 40
Learning to Reconstruct CT Images From the VVBP-Tensor
Tao, X., Wang, Y., Lin, L., Hong, Z., & Ma, J. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3090257 · Cited by 35
Deep Learning With Adaptive Hyper-Parameters for Low-Dose CT Image Reconstruction
Ding, Q., Nan, Y., Gao, H., & Ji, H. (2021) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2021.3093003 · Cited by 39
Gap compensation during PET image reconstruction by constrained, total variation minimization
Ahn, S., Kim, S. M., Son, J., Lee, D. S., & Lee, J. S. (2012) · Medical Physics · doi:10.1118/1.3673775 · Cited by 31
Efficient low‐dose CT artifact mitigation using an artifact‐matched prior scan
Xu, W., & Mueller, K. D. (2012) · Medical Physics · doi:10.1118/1.4736528 · Cited by 32
Error bounds and stability in the $l_{0}$ regularized for CT reconstruction from small projections
Wang, C., & Zeng, L. (2016) · Inverse Problems and Imaging · doi:10.3934/ipi.2016023 · Cited by 30
Wang, T., & Zhu, L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/6684 · Cited by 30
Accurate Iterative FBP Reconstruction Method for Material Decomposition of Dual Energy CT
Li, M., Zhao, Y., & Zhang, P. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2872885 · Cited by 30
Tilley, S., Zbijewski, W. B., & Stayman, J. W. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aaf973 · Cited by 31
McSART: an iterative model-based, motion-compensated SART algorithm for CBCT reconstruction
Chee, G., O’Connell, D. P., Yang, Y. M., Singhrao, K., Low, D. A., & Lewis, J. H. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab07d6 · Cited by 30
Alternating direction method of multipliers for nonconvex log total variation image restoration
Zhang, B., Zhu, G., Zhu, Z., & Kwong, S. (2022) · Applied Mathematical Modelling · doi:10.1016/j.apm.2022.09.018 · Cited by 32
Optical Measurements at the Combustor Exit of the HIFiRE 2 Ground Test Engine
Brown, M., Herring, G. C., Cabell, K. F., Hass, N., Barhorst, T., & Gruber, M. (2012) · AIAA Aerospace Sciences Meeting · doi:10.2514/6.2012-857 · Cited by 30
Guo, Y., Zeng, L., Wang, C., & Zhang, L. (2017) · Applied Mathematical Modelling · doi:10.1016/j.apm.2017.07.057 · Cited by 30
Algorithm‐enabled partial‐angular‐scan configurations for dual‐energy CT
Chen, B., Zhang, Z., Xia, D., Sidky, E. Y., & Pan, X. (2018) · Medical Physics · doi:10.1002/mp.12848 · Cited by 30
Self-citationA Generalized Structured Low-Rank Matrix Completion Algorithm for MR Image Recovery
Hu, Y., Liu, X., & Jacob, M. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2886290 · Cited by 30
A Reweighted Joint Spatial-Radon Domain CT Image Reconstruction Model for Metal Artifact Reduction
Zhang, H., Dong, B., & Liu, B. (2018) · SIAM Journal on Imaging Sciences · doi:10.1137/17m1140212 · Cited by 36
Zeng, G. L., Li, Y., & Zamyatin, A. A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/10/3413 · Cited by 29
A new approach to the investigation of nanoparticles: Electron tomography with compressed sensing
Thomas, J. M., Leary, R. K., Midgley, P. A., & Holland, D. J. (2012) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2012.09.068 · Cited by 33
Liu, T., Rong, J., Gao, P., Pu, H., Zhang, W., Zhang, X., Liang, Z., & Lu, H. (2018) · Biomedical Optics Express · doi:10.1364/boe.10.000001 · Cited by 29
Sparse-view CT reconstruction based on gradient directional total variation
Qu, Z., Zhao, X., Pan, J., & Chen, P. (2019) · Measurement Science and Technology · doi:10.1088/1361-6501/ab09c6 · Cited by 29
Malagi, A., Das, C. J., Khare, K., Calamante, F., & Mehndiratta, A. (2019) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-019-00764-0 · Cited by 30
Compressible Latent-Space Invertible Networks for Generative Model-Constrained Image Reconstruction
Kelkar, V. A., Bhadra, S., & Anastasio, M. A. (2021) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2021.3049648 · Cited by 33
Optimization for customized trajectories in cone beam computed tomography
Hatamikia, S., Biguri, A., Kronreif, G., Kettenbach, J., Russ, T., Furtado, H., Sundar, L. K. S., Buschmann, M., Unger, E., Figl, M., et al. (2020) · Medical Physics · doi:10.1002/mp.14403 · Cited by 32
Noise2Context: Context‐assisted learning 3D thin‐layer for low‐dose CT
Zhang, Z., Liang, X., Zhao, W., & Xing, L. (2021) · Medical Physics · doi:10.1002/mp.15119 · Cited by 34
Kim, B., Shim, H., & Baek, J. (2022) · Medical Physics · doi:10.1002/mp.15885 · Cited by 41
Generalized row-action methods for tomographic imaging
Andersen, M. S., & Hansen, P. C. (2013) · Numerical Algorithms · doi:10.1007/s11075-013-9778-8 · Cited by 34
Gao, H., Zhang, L., Chen, Z., Xing, Y., Xue, H., & Cheng, J. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2274481 · Cited by 29
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.