Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Items 701–800 of 1,000
Xiong, L., Li, N., Qiu, W., Luo, Y., Li, Y., & Zhang, Y. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02966-0 · Cited by 20
Proj2Proj: self-supervised low-dose CT reconstruction
Unal, M. O., Ertaş, M., & Yıldırım, İ. (2024) · PeerJ Computer Science · doi:10.7717/peerj-cs.1849 · Cited by 24
Unsupervised Bayesian generation of synthetic CT from CBCT using patient‐specific score‐based prior
Peng, J., Gao, Y., Chang, C., Qiu, R. L. J., Wang, T., Kesarwala, A. H., Yang, K., Scott, J. G., Yu, D. S., & Yang, X. (2024) · Medical Physics · doi:10.1002/mp.17572 · Cited by 24
Xi, Y., Qiao, Z., Wang, A., Fang, C., & Liu, F. (2024) · Displays · doi:10.1016/j.displa.2024.102812 · Cited by 17
Few views image reconstruction using alternating direction method via ‐norm minimization
Sun, Y., & Tao, J. (2014) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22097 · Cited by 13
Simultaneous reduction of radiation dose and scatter for CBCT by using collimators
Li, T., Li, X., Yang, Y., Zhang, Y., Heron, D. E., & Huq, M. S. (2013) · Medical Physics · doi:10.1118/1.4831970 · Cited by 13
Null-space function estimation for the interior problem
Zeng, G. L., & Gullberg, G. T. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/7/1873 · Cited by 13
Jiang, X., den Broek, W. V., & Koch, C. T. (2016) · Optics Express · doi:10.1364/oe.24.007006 · Cited by 13
Edge-Promoting Adaptive Bayesian Experimental Design for X-ray Imaging
Helin, T., Hyvönen, N., & Puska, J.-P. (2022) · SIAM Journal on Scientific Computing · doi:10.1137/21m1409330 · Cited by 13
Dictionary Learning-Based Image Reconstruction for Terahertz Computed Tomography
Zhong, F., Niu, L., Wu, W., & Liu, F. (2021) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-021-00806-6 · Cited by 13
Sun, W., Chrétien, S., Biguri, A., Soleimani, M., Blumensath, T., & Talbott, J. (2023) · NDT & E International · doi:10.1016/j.ndteint.2023.102852 · Cited by 13
Kang, Y., Liu, J., Wu, F., Wang, K., Qiang, J., Hu, D., & Zhang, Y. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108010 · Cited by 18
On Few-View Tomography and Staircase Artifacts
Zeng, G. L. (2015) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2015.2395952 · Cited by 13
Visualization of Astronomical Nebulae via Distributed Multi-GPU Compressed Sensing Tomography
Wenger, S., Ament, M., Guthe, S., Lorenz, D. A., Tillmann, A. M., Weiskopf, D., & Magnor, M. A. (2012) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2012.281 · Cited by 13
Deformation vector fields (DVF)-driven image reconstruction for 4D-CBCT
Dang, J., Luo, O., Gu, X., & Wang, J. (2015) · Journal of X-Ray Science and Technology · doi:10.3233/xst-140466 · Cited by 15
Lower bounds for the truncated Hilbert transform
Alaifari, R., Pierce, L. B., & Steinerberger, S. (2016) · Revista Matemática Iberoamericana · doi:10.4171/rmi/880 · Cited by 13
Few-view CT reconstruction via a novel non-local means algorithm
Chen, Z., Qi, H., Wu, S., Xu, Y. X., & Zhou, L. (2016) · Physica Medica · doi:10.1016/j.ejmp.2016.05.063 · Cited by 13
Chen, B., Bian, Z., Zhou, X., Chen, W.-S., Ma, J., & Liang, Z. (2018) · Neurocomputing · doi:10.1016/j.neucom.2018.01.037 · Cited by 13
Resolution and noise performance of sparse view X-ray CT reconstruction via Lp-norm regularization
Zhang, L., Zhao, H., Ma, W., Jiang, J., Zhang, L., Li, J., Gao, F., & Zhou, Z. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.04.396 · Cited by 15
Deng, X., Zhao, Y., & Li, H. (2019) · Journal of X-Ray Science and Technology · doi:10.3233/xst-180469 · Cited by 13
RetractedHehn, L., Tilley, S., Pfeiffer, F., & Stayman, J. W. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab489e · Cited by 13
R$$^{2}$$-Net: Recurrent and Recursive Network for Sparse-View CT Artifacts Removal
Shen, T., Li, X., Zhong, Z., Wu, J., & Lin, Z. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32226-7_36 · Cited by 13
A Novel Low-Dose Dual-Energy Imaging Method for a Fast-Rotating Gantry-Type CT Scanner
Cho, S., Lee, S., Lee, J., Lee, D., Kim, H., Ryu, J., Jeong, K., Kim, K.-G., Yoon, K., & Cho, S. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3044357 · Cited by 13
Dual residual convolutional neural network (DRCNN) for low-dose CT imaging
Feng, Z., Cai, A., Wang, Y., Li, L., Tong, L., & Yan, B. (2021) · Journal of X-Ray Science and Technology · doi:10.3233/xst-200777 · Cited by 20
Zhou, H., Liu, X., Wang, H., Chen, Q., Wang, R., Pang, Z., Zhang, Y., & Hu, Z. (2022) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-182 · Cited by 13
Choi, K., Fahimian, B., Li, T., Suh, T. S., & Xing, L. (2013) · Journal of X-Ray Science and Technology · doi:10.3233/xst-130371 · Cited by 15
Temporal resolution and motion artifacts in single‐source and dual‐source cardiac CT
Schöndube, H., Allmendinger, T., Stierstorfer, K., Bruder, H., & Flohr, T. G. (2013) · Medical Physics · doi:10.1118/1.4790695 · Cited by 13
A general method for motion compensation in x-ray computed tomography
Biguri, A., Dosanjh, M. K., Hancock, S., & Soleimani, M. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa7675 · Cited by 13
Unsupervised Image Noise Modeling with Self-Consistent GANPreprint
Yan, H., Chen, X., Tan, V. Y. F., Yang, W., Wu, J., & Feng, J. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1906.05762 · Cited by 17
COO-DuDo: computation overhead optimization methods for dual-domain sparse-view CT reconstruction
Deng, Z., Wang, Z., Shan, Y., He, G., Du, T., & Wang, S. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.128109 · Cited by 12
Zhao, X., Du, Y., Yue, H., Wang, R., Zhou, S., Wu, H., Wang, W., & Peng, Y. (2024) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-23-759 · Cited by 17
Prior Image-Constrained Iterative Reconstruction With Adaptive Step Size for Limited-Angle CBCT
Tao, Y., Zhang, Z., Hu, D., Wu, Z., Mao, W., Zhu, G., Fei, X., Ji, X., Zhang, Y., Xie, S., et al. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3396857 · Cited by 12
Han, Y. D., Liu, X., Zhang, N., Wang, Y., Ju, M., & Yan, D. (2024) · Scientific Reports · doi:10.1038/s41598-024-68668-1 · Cited by 12
Zhong, Y., Zhang, X., Mo, Z., Zhang, S., Nie, L., Chen, W., & Li, Q. (2024) · Photoacoustics · doi:10.1016/j.pacs.2024.100641 · Cited by 12
Jiang, Z., Xu, Y., Sun, L., Srinivasan, S., Wu, Q., Xiang, L., & Ren, L. (2024) · Precision Radiation Oncology · doi:10.1002/pro6.1242 · Cited by 12
Qi, H., Chen, Z., Guo, J., & Zhou, L. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151437 · Cited by 12
Dictionary learning based low-dose x-ray CT reconstruction using a balancing principle
Mou, X., Wu, J., Bai, T., Xu, Q., Yu, H., & Wang, G. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2065459 · Cited by 12
Zheng, Z., Papenhausen, E., & Mueller, K. D. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/21/7857 · Cited by 13
Unberath, M., Choi, J., Berger, M., Maier, A., & Fahrig, R. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2081559 · Cited by 12
An Effective CUDA Parallelization of Projection in Iterative Tomography Reconstruction
Xie, L., Hu, Y., Yan, B., Wang, L., Yang, B., Liu, W., Zhang, L., Luo, L., Shu, H., & Chen, Y. (2015) · PLoS ONE · doi:10.1371/journal.pone.0142184 · Cited by 15
Wu, J., Lerotic, M., Collins, S. M., Leary, R. K., Saghi, Z., Midgley, P. A., Berejnov, S., Susac, D., Stumper, J., Singh, G., et al. (2017) · Microscopy and Microanalysis · doi:10.1017/s1431927617012466 · Cited by 12
Source and coded aperture joint optimization for compressive X-ray tomosynthesis
Ma, X., Zhao, Q., Cuadros, A. P., Mao, T., & Arce, G. R. (2019) · Optics Express · doi:10.1364/oe.27.006640 · Cited by 13
Yu, W. B., Peng, W. J., Yin, H., Wang, C., & Yu, K. (2020) · Signal Processing · doi:10.1016/j.sigpro.2020.107945 · Cited by 13
LRIP-Net: Low-Resolution Image Prior-Based Network for Limited-Angle CT Reconstruction
Gao, Q., Ding, R., Wang, L., Xue, B., & Duan, Y. (2022) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2022.3217517 · Cited by 12
Huang, Z., Li, W., Wang, Y., Liu, Z., Zhang, Q., Jin, Y., Wu, R., Quan, G., Liang, D., Hu, Z., et al. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102609 · Cited by 13
Iterative image reconstruction for limited‐angle inverse helical cone‐beam computed tomography
Yu, W. B., & Zeng, L. (2015) · Scanning · doi:10.1002/sca.21235 · Cited by 12
Sparse-View Ultrasound Diffraction Tomography Using Compressed Sensing with Nonuniform FFT
Hua, S., Ding, M., & Yuchi, M. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/329350 · Cited by 12
Yang, M., Li, R., Duan, J., Liang, L., Li, X., Liu, W., & Meng, F. (2013) · NDT & E International · doi:10.1016/j.ndteint.2013.07.006 · Cited by 12
Coding for compressive focal tomography
Brady, D. J., & Marks, D. L. (2011) · Applied Optics · doi:10.1364/ao.50.004436 · Cited by 12
Analysis of compressed sensing based CT reconstruction with low radiation
Hou, W., & Zhang, C. (2014) · International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS) · doi:10.1109/ispacs.2014.7024471 · Cited by 12
Investigation of sparse data mouse imaging using micro-CT with a carbon-nanotube-based X-ray source
Bian, J., Han, X., Sidky, E. Y., Cao, G., Lu, J., Zhou, O. Z., & Pan, X. (2010) · Tsinghua Science & Technology · doi:10.1016/s1007-0214(10)70012-2 · Cited by 12
Self-citationLee, H. C., Song, B., Kim, J. S., Jung, J. J., Li, H. H., Mutic, S., & Park, J. C. (2016) · Oncotarget · doi:10.18632/oncotarget.13567 · Cited by 12
Zhao, C., Chen, X., Ouyang, L., Wang, J., & Jin, M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0189620 · Cited by 12
Reconstruction of sparse-view tomography via preconditioned Radon sensing matrix
Theeda, P., Kumar, P. U. P., Sastry, C. S., & Jampana, P. (2018) · Journal of Applied Mathematics and Computing · doi:10.1007/s12190-018-1180-1 · Cited by 12
Yu, W. B., Wang, C., Nie, X., & Zeng, D. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aaeea6 · Cited by 12
Few-view CT image reconstruction using improved total variation regularization
Li, K., Sang, Z., Zhang, X., Zhang, M., Jiang, C., Zhang, Q., Ge, Y., Liang, D., Yang, Y., Liu, X., et al. (2019) · Journal of X-Ray Science and Technology · doi:10.3233/xst-190506 · Cited by 12
Guided Image Filtering Based Limited-Angle CT Reconstruction Algorithm Using Wavelet Frame
Wang, J., Wang, C., Guo, Y., Yu, W. B., & Zeng, L. (2019) · IEEE Access · doi:10.1109/access.2019.2929448 · Cited by 12
Application of deep learning and compressed sensing for reconstruction of images
Hanumanth, P., Bhavana, P. O., & Subbarayappa, S. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1706/1/012068 · Cited by 13
High through-plane resolution CT imaging with self-supervised deep learning
Xie, H., Lei, Y., Wang, T., Tian, Z., Roper, J. R., Bradley, J. D., Curran, W. J., Tang, X., Liu, T., & Yang, X. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac0684 · Cited by 13
Computed Tomography Image Reconstruction from Few-Views Data by Multi-Directional Total Variation
Mian-Yi, C., Yong, R., Peng, F., He, P., Lu-Zhen, D., Wei, B., Li, Z., & Wang, J. (2015) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2015.1392 · Cited by 12
Dictionary Learning Based Low-Dose X-Ray CT Reconstruction
Xu, Q., Yu, H., Wang, G., & Mou, X. (2014) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789814611107_0006 · Cited by 12
Comparison of heuristic and deterministic algorithms in neutron coded imaging reconstruction
Yan, M., Hu, H., Hu, G., Liu, Z., He, C., & Yi, Q. (2020) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2020.164704 · Cited by 11
Xie, E., Ni, P., Zhang, R., & Li, X. (2022) · Applied Sciences · doi:10.3390/app12126268 · Cited by 11
Compressed-sensing-inspired reconstruction algorithms in low-dose computed tomography: A review
Konovalov, A. B. (2024) · Physica Medica · doi:10.1016/j.ejmp.2024.104491 · Cited by 13
Domain Progressive Low-Dose CT Imaging Using Iterative Partial Diffusion Model
Liao, F., Tang, Y., Du, Q., Wang, J., Li, M., & Zheng, J. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3492260 · Cited by 20
SDIP: Self-reinforcement deep image prior framework for image processing
Shu, Z., & Pan, Z. (2025) · Pattern Recognition · doi:10.1016/j.patcog.2025.111786 · Cited by 17
Sompel, D. V. D., & Brady, M. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.08.005 · Cited by 11
Frequency extrapolation by nonconvex compressive sensing
Chartrand, R., Sidky, E. Y., & Pan, X. (2011) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2011.5872583 · Cited by 11
Self-citationPrecise phase transition of total variation minimization
Zhang, B., Xu, W., Jian-feng Cai, A., & Lai, L. (2016) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2016.7472532 · Cited by 11
Gomi, T., Sakai, R., Hara, H., Watanabe, Y., & Mizukami, S. (2019) · PLoS ONE · doi:10.1371/journal.pone.0222406 · Cited by 12
Yuki, R., Ohtake, Y., & Suzuki, H. (2021) · Precision Engineering · doi:10.1016/j.precisioneng.2021.08.023 · Cited by 11
A model-based deep network for limited-angle computed tomography image reconstruction
Wang, W., Xia, X., He, C., Ren, Z., & Lu, J. J. (2022) · Displays · doi:10.1016/j.displa.2022.102166 · Cited by 11
A dual-domain neural network based on sinogram synthesis for sparse-view CT reconstruction
Zhang, P., & Li, K. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107168 · Cited by 11
Xiao, Y., Wang, Z., Li, Y., Hu, X., & Xu, F. (2022) · Journal of Instrumentation · doi:10.1088/1748-0221/17/12/p12018 · Cited by 11
Multislice input for 2D and 3D residual convolutional neural network noise reduction in CT
Zhou, Z., Huber, N. R., Inoue, A., McCollough, C. H., & Yu, L. (2023) · Journal of medical imaging · doi:10.1117/1.jmi.10.1.014003 · Cited by 14
A tabletop X-ray tomography instrument for nanometer-scale imaging: reconstructions
Levine, Z. H., Alpert, B. K., Dagel, A. L., Fowler, J. W., Jimenez, E. S., Nakamura, N., Swetz, D. S., Szypryt, P., Thompson, K., & Ullom, J. N. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00510-6 · Cited by 11
Kim, S.-J., Kim, B., Lee, J., & Baek, J. (2023) · Medical Physics · doi:10.1002/mp.16552 · Cited by 16
Li, L., Chen, Z., Zhao, Z., & Wu, D. (2013) · Optical Engineering · doi:10.1117/1.oe.52.1.013201 · Cited by 11
Low-Dose Micro-CT Imaging for Vascular Segmentation and Analysis Using Sparse-View Acquisitions
Vandeghinste, B., Vandenberghe, S., Vanhove, C., Staelens, S. G., & Holen, R. V. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068449 · Cited by 11
Maier, J., Sawall, S., & Kachelrieß, M. (2014) · Medical Physics · doi:10.1118/1.4870983 · Cited by 11
Rodríguez-Álvarez, M. J., Soriano, A., Iborra, A., Sánchez, F., González, A. J., Condé, P., Hernández, L., Moliner, L., Orero, A., Vidal, L., et al. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.04.015 · Cited by 11
Nonparametric optimization of constrained total variation for tomography reconstruction
Liu, L., Yin, Z., & Ma, X. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.09.014 · Cited by 11
Image reconstruction from sparse data in synchrotron-radiation-based microtomography
Xia, D., Xiao, X., Bian, J., Han, X., Sidky, E. Y., Carlo, F. D., & Pan, X. (2011) · Review of Scientific Instruments · doi:10.1063/1.3572263 · Cited by 11
Self-citationReconstruction of sparse-view X-ray computed tomography using adaptive iterative algorithms
Liu, L., Lin, W., & Jin, M. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.11.001 · Cited by 11
Sparse-View CT Image Recovery Using Two-Step Iterative Shrinkage-Thresholding Algorithm
Chae, B. G., & Lee, S. (2015) · ETRI Journal · doi:10.4218/etrij.15.0115.0401 · Cited by 11
Total variation–based method for generation of intravoxel incoherent motion parametric images in MRI
Lin, C., Shih, Y., Huang, S., & Huang, H. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26528 · Cited by 11
Zhang, H., Zhang, L., Sun, Y., Zhang, J., & Chen, L. (2016) · Optik · doi:10.1016/j.ijleo.2016.11.186 · Cited by 11
Gomi, T., Sakai, R., Goto, M., Hara, H., Watanabe, Y., & Umeda, T. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.07.023 · Cited by 11
Jin, S.-C., Hsieh, C.-J., Chen, J., Tu, S.-H., Chen, Y.-C., Hsiao, T., Liu, A., Chou, W.-H., Chu, W., & Kuo, C. (2018) · Sensors · doi:10.3390/s18124458 · Cited by 11
Artifact Suppressed Nonlinear Diffusion Filtering for Low-Dose CT Image Processing
Liu, Y., Chen, Y., Chen, P., Qiao, Z., & Gui, Z. (2019) · IEEE Access · doi:10.1109/access.2019.2933541 · Cited by 11
Sparse-view tomography via displacement function interpolation
Zeng, G. L. (2019) · Visual Computing for Industry Biomedicine and Art · doi:10.1186/s42492-019-0024-7 · Cited by 11
Zhou, H., Zhu, Y., Wang, Q., Xu, J., Li, G., Chen, D., Dong, Y., & Zhang, H. (2019) · IEEE Access · doi:10.1109/access.2019.2962071 · Cited by 11
A sequential regularization based image reconstruction method for limited-angle spectral CT
Sheng, W., Zhao, X., & Li, M. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab9771 · Cited by 11
Texture‐aware dual domain mapping model for low‐dose CT reconstruction
Wang, H., Zhao, X., Liu, W., Li, L. C., Ma, J., & Guo, L. (2022) · Medical Physics · doi:10.1002/mp.15607 · Cited by 12
Langet, H., Riddell, C., Reshef, A., Trousset, Y. L., Tenenhaus, A., Lahalle, E., Fleury, G., & Nikos Paragios, A. (2015) · Medical Physics · doi:10.1118/1.4928144 · Cited by 11
Song, B., Park, J. C., & Song, W. Y. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/21/6565 · Cited by 11
Improving Low-dose Cardiac CT Images based on 3D Sparse Representation
Shi, L., Hu, Y., Chen, Y., Yin, X., Shu, H., Luo, L., & Coatrieux, J.-L. (2016) · Scientific Reports · doi:10.1038/srep22804 · Cited by 11
Deng, L., Feng, P., Chen, M., He, P., & Wei, B. (2016) · BioMed Research International · doi:10.1155/2016/3094698 · Cited by 11
End-to-End Abnormality Detection in Medical Imaging
Wu, D., Kim, K. S., Dong, B., & Li, Q. (2018) · Cited by 13
Gomi, T., & Koibuchi, Y. (2018) · BioMed Research International · doi:10.1155/2018/5239082 · Cited by 11
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.