Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The class trivially includes denoising and deconvolution, but also includes MRI [35], X-ray CT [13], [16], and diffraction tomography (DT).”
From Deep Convolutional Neural Network for Inverse Problems in Imaging (2017) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Alizadeh, F., & Goldfarb, D. (2003) · Mathematical Programming · doi:10.1007/s10107-002-0339-5 · Cited by 1,500
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Research works printed but not linked: 3
- Lange K, 1984, J. Comput. Assist. Tomogr., 8, 306
- Sidky E Y Pan X Kacheriess M Beekman F Müller K, 2007, 9th Int. Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 60
- Song J, 2007, IEEE Trans. Nucl. Sci., 34, 4476
Cited by
Items 801–900 of 1,000
Nonlocal total variation based dynamic PET image reconstruction with low-rank constraints
Zhang, Z., & Liu, H. (2019) · Physica Scripta · doi:10.1088/1402-4896/ab0854 · Cited by 11
Liu, B., Yu, H., Verbridge, S. S., Sun, L., & Wang, G. (2014) · Scanning · doi:10.1002/sca.21121 · Cited by 11
A 4D-CBCT correction network based on contrastive learning for dose calculation in lung cancer
Cao, N., Wang, Z., Ding, J., Zhang, H., Zhang, S., Gao, L., Sun, J., Xie, K., & Ni, X. (2024) · Radiation Oncology · doi:10.1186/s13014-024-02411-y · Cited by 13
Target‐specific optimization of four‐dimensional cone beam computed tomography
Ahmad, M. U., & Pan, T. (2012) · Medical Physics · doi:10.1118/1.4747609 · Cited by 10
A Compton scattering image reconstruction algorithm based on total variation minimization
Li, S., Wang, L., Yan, B., Li, L., & Liu, Y.-J. (2012) · Chinese Physics B · doi:10.1088/1674-1056/21/10/108703 · Cited by 10
Reconstruction of limited-angle dual-energy CT using mutual learning and cross-estimation (MLCE)
Zhang, H., & Xing, Y. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2211224 · Cited by 10
Microstructural Quantification and Property Prediction Using Limited X-ray Tomography Data
Li, H., Singh, S., Kaira, C. S., Mertens, J. C. E., Williams, J., Chawla, N., & Jiao, Y. (2016) · JOM · doi:10.1007/s11837-016-2024-9 · Cited by 10
Sparse-Prior-Based Projection Distance Optimization Method for Joint CT-MRI Reconstruction
Cui, X., Mili, L., & Yu, H. (2017) · IEEE Access · doi:10.1109/access.2017.2754327 · Cited by 10
Multi-energy CT reconstruction using tensor nonlocal similarity and spatial sparsity regularization
Zhang, W., Liang, N., Wang, Z., Cai, A., Wang, L., Tang, C., Zheng, Z., Li, L., Yan, B., & Hu, G. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-594 · Cited by 11
Computational imaging with an extended field of view
Malik, R., Elangovan, R., & Khare, K. (2021) · Journal of Optics · doi:10.1088/2040-8986/ac0ff6 · Cited by 10
A modified algebraic reconstruction algorithm for sparse projection
Li, H., & Wan, Z. (2021) · Annals of Translational Medicine · doi:10.21037/atm-21-3529 · Cited by 10
Tan, C., Yu, H., Xi, Y., Li, L., Liao, M., Liu, F., & Duan, L. (2022) · Optics Express · doi:10.1364/oe.442287 · Cited by 10
ADMM-SVNet: An ADMM-Based Sparse-View CT Reconstruction Network
Wang, S., Li, X., & Chen, P. (2022) · Photonics · doi:10.3390/photonics9030186 · Cited by 11
Donato, S., Brombal, L., Peña, L. M. A., Arfelli, F., Contillo, A., Delogu, P., Lillo, F. D., Trapani, V. D., Fanti, V., Longo, R., et al. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac65d4 · Cited by 11
A thresholding based iterative reconstruction method for limited-angle tomography data
Piault, P., King, A., Henry, L., Rathore, J. S., Guignot, N., Deslandes, J.-P., & Itié, J. P. (2023) · Tomography of Materials and Structures · doi:10.1016/j.tmater.2023.100008 · Cited by 10
Image Reconstruction from Sparse Projections Using S-Transform
Luo, J., Liu, J., Li, W., Zhu, Y., & Jiang, R. (2011) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-011-0307-x · Cited by 10
Compressive computed tomography image reconstruction with denoising message passing algorithms
Perelli, A., & Davies, M. E. (2015) · European Signal Processing Conference (EUSIPCO) · doi:10.1109/eusipco.2015.7362896 · Cited by 10
Alternating Iteration for $l_{p}$ ( $0<p\leq 1$ ) Regularized CT Reconstruction
Miao, C., & Yu, H. (2016) · IEEE Access · doi:10.1109/access.2016.2596704 · Cited by 10
Pixel-wise estimation of noise statistics on iterative CT reconstruction from a single scan
Wang, T., & Zhu, L. (2017) · Medical Physics · doi:10.1002/mp.12302 · Cited by 10
Reduction of variable-truncation artifacts from beam occlusion during in situ x-ray tomography
Borg, L., Jørgensen, J. S., Frikel, J., & Jon Sporring, A. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa8c27 · Cited by 10
Rodríguez-Álvarez, M. J., Sánchez, F., Soriano, A., Moliner, L., Sánchez, S., & Benlloch, J. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2843803 · Cited by 9
Traditional machine learning for limited angle tomography
Huang, Y., Lu, Y., Taubmann, O., Lauritsch, G., & Maier, A. (2018) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-018-1851-2 · Cited by 10
GPU acceleration of a model-based iterative method for Digital Breast Tomosynthesis
Cavicchioli, R., Hu, J. C., Piccolomini, E. L., Morotti, E., & Zanni, L. (2020) · Scientific Reports · doi:10.1038/s41598-019-56920-y · Cited by 11
Blind restoration of solar images via the Channel Sharing Spatio-temporal Network
Wang, S., Chen, Q., He, C., Zhang, C., Zhong, L., Bao, H., & Rao, C. (2021) · Astronomy and Astrophysics · doi:10.1051/0004-6361/202140376 · Cited by 11
Stabilizing dual-energy x-ray computed tomography reconstructions using patch-based regularization
Tracey, B., & Miller, E. L. (2015) · Inverse Problems · doi:10.1088/0266-5611/31/10/105004 · Cited by 10
The Performance of MLEM for Dynamic Imaging From Simulated Few-View, Multi-Pinhole SPECT
Ma, D., Wolf, P. A., Clough, A. V., & Schmidt, T. G. (2012) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2012.2214235 · Cited by 10
Enhancing tissue structures with iterative image reconstruction for digital breast tomosynthesis
Sidky, E. Y., Reiser, I., Nishikawa, R. M., & Pan, X. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2043776 · Cited by 10
Self-citationChen, C., & Xu, G. (2012) · Inverse Problems · doi:10.1088/0266-5611/28/3/035006 · Cited by 10
Shieh, C., Kipritidis, J., O'Brien, R. T., Cooper, B. J., Kuncic, Z., & Keall, P. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/841 · Cited by 10
Simultaneous 4D‐CBCT reconstruction with sliding motion constraint
Dang, J., Yin, F.-F., You, T., Dai, C., Chen, D., & Wang, J. (2016) · Medical Physics · doi:10.1118/1.4959998 · Cited by 10
Pua, R. D., Park, M., Wi, S., & Cho, S. (2016) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2016.09.059 · Cited by 10
Euler’s Elastica Strategy for Limited-angle Computed Tomography Image Reconstruction
Zhang, H., Wang, L., Duan, Y., Li, L., Hu, G., & Yan, B. (2017) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2017.2717864 · Cited by 10
Motion guided Spatiotemporal Sparsity for high quality 4D-CBCT reconstruction
Liu, Y., Tao, X., Ma, J., Bian, Z., Zeng, D., Feng, Q., Chen, W., & Zhang, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-17668-5 · Cited by 10
Wu, J., Dai, F., Hu, G., & Mou, X. (2018) · Journal of X-Ray Science and Technology · doi:10.3233/xst-17358 · Cited by 10
Improve 3D cone-beam CT reconstruction by slice-wise deep learning
Yang, H., Liang, K., Zhang, L., Kang, K., & Xing, Y. (2018) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2018.8824423 · Cited by 10
Wu, J., Wang, X., Mou, X., Chen, Y., & Liu, S. (2020) · Sensors · doi:10.3390/s20061647 · Cited by 9
Bilateral extended FDK: An improved weighting method for static CT imaging
Zha, K., Zhao, Q., Luo, S., & Li, Y. (2023) · Medical Physics · doi:10.1002/mp.16639 · Cited by 9
Self‐adaption and texture generation: A hybrid loss function for low‐dose CT denoising
Wang, Z., Liu, M., Cheng, X., Zhu, J., Wang, X., Gong, H., Liu, M., & Xu, L. (2023) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.14113 · Cited by 13
Reducing image artifacts in sparse projection CT using conditional generative adversarial networks
Usui, K., Kamiyama, S., Arita, A., Ogawa, K., Sakamoto, H., Sakano, Y., Kyogoku, S., & Daida, H. (2024) · Scientific Reports · doi:10.1038/s41598-024-54649-x · Cited by 9
Image fast reconstruction for sparse view computed tomography with reduced sampling integration time
Long, C., Tan, C., Zhao, E., Tan, H., & Duan, L. (2024) · Displays · doi:10.1016/j.displa.2024.102734 · Cited by 10
Anisotropic regularization for inversion of fast-ion loss detector measurements
Schmidt, B. S., Jørgensen, J. S., Rueda-Rueda, J., Galdón-Quiroga, J., García-Muñoz, M., Salewski, M., & the ASDEX Upgrade Team (2024) · Nuclear Fusion · doi:10.1088/1741-4326/ad75a5 · Cited by 9
Asymmetric Convolution-based GAN Framework for Low-Dose CT Image Denoising
Saidulu, N., & Muduli, P. R. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.109965 · Cited by 14
Estimation of noise properties for TV-regularized image reconstruction in computed tomography
Sánchez, A. A. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/18/7007 · Cited by 11
A two-step filtering-based iterative image reconstruction method for interior tomography
Zhang, H., Li, L., Yan, B., Wang, L., Cai, A., & Hu, G. (2016) · Journal of X-Ray Science and Technology · doi:10.3233/xst-160584 · Cited by 9
Brix, M. A. K., Kotiaho, A., Nieminen, M. T., & Inkinen, S. I. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.5.052102 · Cited by 9
Material-separating regularizer for multi-energy x-ray tomography
Gondzio, J., Lassas, M. J., Latva-Äijö, S.-M., Siltanen, S., & Zanetti, F. (2021) · Inverse Problems · doi:10.1088/1361-6420/ac4427 · Cited by 9
Wang, C., Shi, R., Tuo, X., Yang, G., Li, Z., Zheng, H., Mu, X., & Liu, M. (2022) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2022.167110 · Cited by 11
Sinogram restoration in computed tomography with an edge‐preserving penalty
Little, K. J., & Rivière, P. J. L. (2015) · Medical Physics · doi:10.1118/1.4907968 · Cited by 9
Ground-truth verification of dynamic x-ray micro-tomography images of fluid displacement
Myers, G. R., Varslot, T. K., Kingston, A. M., Herring, A. L., & Sheppard, A. P. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.929410 · Cited by 9
Some proximal methods for CBCT and PET tomography
Anthoine, S., Aujol, J., Boursier, Y., & Mélot, C. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.893415 · Cited by 9
Je, U., Lee, M. S., Cho, H. S., Hong, D. K., Park, Y. O., Park, C., Cho, H. M., Choi, S., & Woo, T. H. (2014) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2014.12.079 · Cited by 9
An Active Contour Method for Bone Cement Reconstruction From C-Arm X-Ray Images
Lucas, B. C., Otake, Y., Armand, M., & Taylor, R. H. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2171498 · Cited by 9
Dynamic SPECT reconstruction from few projections: a sparsity enforced matrix factorization approach
Ding, Q., Zan, Y., Huang, Q., & Zhang, X. (2015) · Inverse Problems · doi:10.1088/0266-5611/31/2/025004 · Cited by 9
Xu, F., Dong, B., Hu, X., Xiao, Y., & Wang, Y. (2016) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2016.05.017 · Cited by 9
Sparse-View CT Reconstruction Using Curvelet and TV-Based Regularization
Yazdanpanah, A. P., & Regentova, E. E. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-41501-7_75 · Cited by 9
Proposal of fault-tolerant tomographic image reconstruction
Kudo, H., Takaki, K., Yamazaki, F., & Nemoto, T. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2237107 · Cited by 9
Memory-efficient algorithm for stored projection and backprojection matrix in helical CT
Guo, M., & Gao, H. (2017) · Medical Physics · doi:10.1002/mp.12118 · Cited by 9
Edge-preserving denoising for intra-operative cone beam CT in endovascular aneurysm repair
Liu, Y., Castro, M., Léderlin, M., Shu, H., Kaladji, A., & Haigron, P. (2017) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2017.01.004 · Cited by 9
Zhang, L., Zeng, L., & Guo, Y. (2018) · Journal of X-Ray Science and Technology · doi:10.3233/xst-17334 · Cited by 9
An adaptive iteration reconstruction method for limited-angle CT image reconstruction
Wang, C., Zeng, L., Zhang, L., Guo, Y., & Yu, W. B. (2018) · Journal of Inverse and Ill-Posed Problems · doi:10.1515/jiip-2017-0034 · Cited by 9
Liu, Y., Castro, M., Léderlin, M., Kaladji, A., & Haigron, P. (2018) · BMC Medical Imaging · doi:10.1186/s12880-018-0269-1 · Cited by 9
Zellner, M. B., & Champley, K. (2019) · International Journal of Impact Engineering · doi:10.1016/j.ijimpeng.2019.02.011 · Cited by 9
An Analysis of the Superiorization Method via the Principle of Concentration of Measure
Censor, Y., & Levy, E. (2019) · Applied Mathematics & Optimization · doi:10.1007/s00245-019-09628-4 · Cited by 9
Multichannel interpolation of nonuniform samples with application to image recovery
Cheng, D., & Kou, K. I. (2019) · Journal of Computational and Applied Mathematics · doi:10.1016/j.cam.2019.112502 · Cited by 9
Yan, M., Ma, B., Tian, B., Hu, G., Wu, R., & Wang, S. (2020) · Annals of Nuclear Energy · doi:10.1016/j.anucene.2020.107970 · Cited by 9
NON-ITERATIVE MICROWAVE IMAGING SOLUTIONS FOR INVERSE PROBLEMS USING DEEP LEARNING
Anjit, T. A., Benny, R., Cherian, P., & Mythili, P. (2021) · Progress In Electromagnetics Research M · doi:10.2528/pierm21021304 · Cited by 9
Regularization-parameter-free optimization approach for image deconvolution
Rajora, S., Butola, M., & Khare, K. (2021) · Applied Optics · doi:10.1364/ao.426353 · Cited by 9
Rahim, T., Novamizanti, L., Ramatryana, I. N. A., Shin, S. Y., & Kim, D. (2021) · IEEE Access · doi:10.1109/access.2021.3107904 · Cited by 9
Deep frequency-recurrent priors for inverse imaging reconstruction
He, Z., Hong, K., Zhou, J., Liang, D., Wang, Y., & Liu, Q. (2021) · Signal Processing · doi:10.1016/j.sigpro.2021.108320 · Cited by 14
Wang, R. C., Li, D., Sun, T., Peng, X., Yang, Z. X., & Wang, J. (2023) · Journal of Geophysical Research Space Physics · doi:10.1029/2022ja030424 · Cited by 9
Cheng, W., He, J., Liu, Y., Zhang, H., Wang, X., Liu, Y., Zhang, P., Chen, H., & Gui, Z. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.107161 · Cited by 9
Deng, L., Mi, D., He, P., Feng, P., Yu, P., Chen, M., Li, Z., Wang, J., & Wei, B. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151468 · Cited by 9
EM tomographic image reconstruction using polar voxels
Soriano, A., Rodríguez-Álvarez, M. J., Iborra, A., Sánchez, F., Carles, M., Condé, P., González, A. J., Hernández, L., Moliner, L., Orero, A., et al. (2013) · Journal of Instrumentation · doi:10.1088/1748-0221/8/01/c01004 · Cited by 9
Abascal, J., Abella, M., Sisniega, A., Vaquero, J. J., & Desco, M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0120140 · Cited by 11
Je, U., Cho, H., Lee, M., Oh, J. E., Park, Y., Hong, D., Park, C., Cho, H., Choi, S. I., & Koo, Y. (2014) · Journal of the Korean Physical Society · doi:10.3938/jkps.64.1907 · Cited by 9
The current state and prospects of X-ray computational tomography
Чахлов, С. В., Osipov, S. P., Temnik, A. K., & Udod, V. A. (2016) · Russian Journal of Nondestructive Testing · doi:10.1134/s1061830916040033 · Cited by 9
Wang, C., Zeng, L., Yu, W. B., & Xu, L. (2018) · Inverse Problems and Imaging · doi:10.3934/ipi.2018024 · Cited by 9
Melli, S., Wahid, K. A., Babyn, P., Cooper, D. M. L., & Hasan, A. M. (2018) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2018.08.005 · Cited by 9
Gong, C., Zeng, L., Guo, Y., Wang, C., & Wang, S. (2018) · Review of Scientific Instruments · doi:10.1063/1.5030673 · Cited by 9
SparseCT: System concept and design of multislit collimators
Chen, B., Kobler, E., Muckley, M. J., Sodickson, A. D., O’Donnell, T., Flohr, T. G., Schmidt, B., Sodickson, D. K., & Otazo, R. (2019) · Medical Physics · doi:10.1002/mp.13544 · Cited by 9
Sparsity-assisted phase retrieval in the Fresnel zone
Gaur, C., & Khare, K. (2019) · Journal of Modern Optics · doi:10.1080/09500340.2019.1615142 · Cited by 9
Guo, Y., Zeng, L., Wang, J., & Shen, Z. (2019) · Journal of Inverse and Ill-Posed Problems · doi:10.1515/jiip-2019-0012 · Cited by 9
Riis, N. A. B., Dong, Y., & Hansen, P. C. (2020) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-020-00972-7 · Cited by 9
Low-dose dental CT image enhancement using a multiscale feature sensing network
Chen, Q., Yuan, Z., Zhou, C., Zhang, W., Zhang, M., Yang, Y., Liang, D., Liu, X., Zheng, H., Cheng, G., et al. (2020) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2020.164530 · Cited by 9
Denoising low dose CT images via 3D total variation using CUDA
Mao, B., Xiao, D., Xiong, X., Chen, X., Zhang, W., & Kang, Y. (2013) · IEEE International Conference on Medical Imaging Physics and Engineering (ICMIPE) · doi:10.1109/icmipe.2013.6864501 · Cited by 9
Superiorization and Perturbation Resilience of Algorithms: A Continuously Updated BibliographyPreprint
Censor, Y. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1506.04219 · Cited by 9
Extreme Few-view CT Reconstruction using Deep InferencePreprint
Kim, H., Anirudh, R., Mohan, K. A., & Champley, K. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.05375 · Cited by 9
A deep network for sinogram and CT image reconstructionPreprint
Wang, W., Xia, X., He, C., Ren, Z., Lu, J. G., Wang, T., & Lei, B. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2001.07150 · Cited by 10
Low-Dose CT Image Denoising Using Parallel-Clone NetworksPreprint
Li, S., & Wang, G. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2005.06724 · Cited by 14
Single-shot extended field of view imaging using point spread function engineering
Malik, R., & Khare, K. (2023) · Journal of the Optical Society of America A · doi:10.1364/josaa.484734 · Cited by 8
Liang, Z., Wei, H., Liu, G., Cheng, M., Gao, J., Li, S., & Tian, X. (2024) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2023.100809 · Cited by 10
Directional TV algorithm for fast EPR imaging
Fang, C., Xi, Y., Epel, B., Halpern, H. J., & Qiao, Z. (2024) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2024.107652 · Cited by 8
Li, G., Deng, Z., Ge, Y., & Luo, S. (2024) · Bioengineering · doi:10.3390/bioengineering11070646 · Cited by 10
Self-supervised learning for CT image denoising and reconstruction: a review
Choi, K. (2024) · Biomedical Engineering Letters · doi:10.1007/s13534-024-00424-w · Cited by 11
Design of a PG-SPECT for boron concentration monitoring in BNCT at XJTU
Fan, J., Jiang, Q., Hu, Y., Zheng, H., Qiao, Z., Dai, Y., Liu, K., Liu, K., Yan, M., Chen, X., et al. (2025) · Nuclear Engineering and Technology · doi:10.1016/j.net.2025.103499 · Cited by 8
A simple and fast ASD-POCS algorithm for image reconstruction
Qiao, Z. (2021) · Journal of X-Ray Science and Technology · doi:10.3233/xst-210858 · Cited by 8
Method for restoration of X-ray absorption fine structure in sparse spectroscopic ptychography
Ishiguro, N., & Takahashi, Y. (2022) · Journal of Applied Crystallography · doi:10.1107/s1600576722006380 · Cited by 8
Pan, H., Zhao, S., Zhang, W., Zhang, H., & Zhao, X. (2023) · Inverse Problems · doi:10.1088/1361-6420/acdaee · Cited by 11
PFCM: Poisson Flow Consistency Models for Low-Dose CT Image Denoising
Hein, D., Stevens, G. M., Wang, A., & Wang, G. (2025) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2025.3558019 · Cited by 20
Melli, S., Wahid, K. A., Babyn, P., Montgomery, J., Snead, E. C. R., El-Gayed, A. A. H., Pettitt, M. J., Wolkowski, B., & Wesolowski, M. J. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.10.013 · Cited by 9
Metadata
- Authors
- Sidky, E. Y., & Pan, X.
- Affiliations
- University of Chicago (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-13
- Volume
- 53
- Issue
- 17
- Pages
- 4777-4807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC2630711
- OpenAlex
- W1972150100
- Cited by
- 1,995
- References
- 53
- Citations by year
- 2026: 80 · 2025: 138 · 2024: 114 · 2023: 118 · 2022: 119 · 2021: 178 · 2020: 114 · 2019: 164 · 2018: 150 · 2017: 118 · 2016: 122 · 2015: 125 · 2014: 126 · 2013: 111 · 2012: 88
- FWCI
- 32.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA120540)
- National Institute of Biomedical Imaging and Bioengineering (K01EB003913, R01EB000225)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Sparse and Compressive Sensing Techniques
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- image reconstruction, total variation minimization, projection onto convex sets, cone-beam artifacts, compressed sensing, expectation-maximization comparison
- MeSH terms
- Algorithms, Computer Simulation, Humans, Image Processing, Computer-Assisted, Models, Theoretical, Radiographic Image Interpretation, Computer-Assisted, Software, X-Rays, Models, Statistical, Tomography Scanners, X-Ray Computed, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.