Fetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Following the rapid progress in the development of optically pumped magnetometer (OPM) technology for the measurement of magnetic fields in the femtotesla range, a successful assembly of individual sensors into an array of nearly identical sensors is within reach. Here, 25 microfabricated OPMs with footprints of 1 cm(3) were assembled into a conformal array. The individual sensors were inserted into three flexible belt-shaped holders and connected to their respective light sources and electronics, which reside outside a magnetically shielded room, through long optical and electrical cables. With this setup the fetal magnetocardiogram of a pregnant woman was measured by placing two sensor belts over her abdomen and one belt over her chest. The fetal magnetocardiogram recorded over the abdomen is usually dominated by contributions from the maternal magnetocardiogram, since the maternal heart generates a much stronger signal than the fetal heart. Therefore, signal processing methods have to be applied to obtain the pure fetal magnetocardiogram: orthogonal projection and independent component analysis. The resulting spatial distributions of fetal cardiac activity are in good agreement with each other. In a further exemplary step, the fetal heart rate was extracted from the fetal magnetocardiogram. Its variability suggests fetal activity. We conclude that microfabricated optically pumped magnetometers operating at room temperature are capable of complementing or in the future even replacing superconducting sensors for fetal magnetocardiography measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A blind source separation technique using second-order statistics
Belouchrani, A., Abed-Meraim, K., Cardoso, J.-F., & Moulines, E. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.554307 · Cited by 2,775 · cited 1×
“The second-order blind-identification algorithm (SOBI, TDSEP is a synonymous abbreviation) (Belouchrani et al 1997, Ziehe and Müller 1998) uses time-delayed covariance matrices Cτ of the form τ= ( ) ( + )τ x t x tC , ,i j t (3) where xi (xj) denotes the time series of the ith (jth) signal channel,…”
MethodHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441 · cited 1×
“Nevertheless, optically pumped magnetometers operating under similar conditions have previously been validated in standard two-layer MSRs for measurements of MEG (Johnson et al 2013, Shah and Wakai 2013) and fetal MCG (Wyllie et al 2012), as well as MEG in human size shield cans (Xia et al 2006).”
MethodA Review of Fetal ECG Signal Processing Issues and Promising Directions
Sameni (2010) · The Open Pacing, Electrophysiology & Therapy Journal · doi:10.2174/1876536x01003010004 · Cited by 410
Microfabricated alkali atom vapor cells
Liew, L.-A., Knappe, S., Moreland, J., Robinson, H., Hollberg, L., & Kitching, J. (2004) · Applied Physics Letters · doi:10.1063/1.1691490 · Cited by 374
Self-citationTDSEP — an efficient algorithm for blind separation using time structure
Ziehe, A., & Müller, K.-R. (1998) · Perspectives in Neural Computing · doi:10.1007/978-1-4471-1599-1_103 · Cited by 334
Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Magnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Self-citationFrequency-domain description of a lock-in amplifier
Scofield, J. H. (1994) · American Journal of Physics · doi:10.1119/1.17629 · Cited by 224
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Detection of very weak magnetic fields (10−9gauss) by 87Rb zero-field level crossing resonances
Dupont-Roc, J., Haroche, S., & Cohen-Tannoudji, C. (1969) · Physics Letters A · doi:10.1016/0375-9601(69)90480-0 · Cited by 182
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174 · cited 1×
“Currently, biomagnetic signals such as fetal magnetocardiogram (fMCG) and magnetocardiogram (MCG) of adults are recorded with superconducting quantum interference devices (SQUIDs) (Grimm et al 2003, Fenici et al 2005).”
BackgroundA low-power, high-sensitivity micromachined optical magnetometer
Mhaskar, R., Knappe, S., & Kitching, J. (2012) · Applied Physics Letters · doi:10.1063/1.4770361 · Cited by 171 · cited 2×
“Miniature atomic magnetometers and array design The multichannel µOPM array consisted of 25 microfabricated sensor heads (Mhaskar et al 2012) connected to a common control unit by optical fibers of 5 m in length.”
BackgroundMethodSelf-citationOptical magnetometer array for fetal magnetocardiography
Wyllie, R., Kauer, M., Wakai, R. T., & Walker, T. G. (2012) · Optics Letters · doi:10.1364/ol.37.002247 · Cited by 148 · cited 3×
“Nevertheless, optically pumped magnetometers operating under similar conditions have previously been validated in standard two-layer MSRs for measurements of MEG (Johnson et al 2013, Shah and Wakai 2013) and fetal MCG (Wyllie et al 2012), as well as MEG in human size shield cans (Xia et al 2006).”
BackgroundMethodInfluentialGrowth of Interorbital Distance and Skull Thickness as Observed in Roentgenographic Measurements
Hansman, C. F. (1966) · Radiology · doi:10.1148/86.1.87 · Cited by 133 · cited 2×
“Here, we demonstrated that μOPMs are an attractive alternative to SQUID sensors for the measurement of fMCG; they operate without a cryogenic infrastructure, facilitate closer proximity placement to the signal sources, and allow for variable and conformal sensor array geometries. Well-tested algorithms yielded convinc…”
BackgroundMethodMulti-sensor magnetoencephalography with atomic magnetometers
Johnson, C. N., Schwindt, P. D. D., & Weisend, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/17/6065 · Cited by 131
Fetal cardiac arrhythmia detection and in utero therapy
Strasburger, J. F., & Wakai, R. T. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.32 · Cited by 128
Knappe, S., Sander, T. H., Kosch, O., Wiekhorst, F., Kitching, J., & Trahms, L. (2010) · Applied Physics Letters · doi:10.1063/1.3491548 · Cited by 122
Self-citationCompact long-term recorder for the transabdominal foetal and maternal electrocardiogram
Piéri, J. F., Crowe, J. A., Hayes‐Gill, B., Spencer, C., Bhogal, K., & James, D. K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345275 · Cited by 119
(1974) · Journal of Perinatal Medicine · doi:10.1515/jpme.1974.2.3.214 · Cited by 112 · cited 1×
“In contrast to electrical potentials, magnetic fields are not heavily distorted by this thin insulating layer (Kariniemi et al 1974, Wakai et al 2000).”
BackgroundAntenatal fetal magnetocardiography: a new method for fetal surveillance?
Quinn, A., Weir, A. I., Shahani, U., Bain, R. J. P., Maas, P. M., & Donaldson, G. B. (1994) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13547.x · Cited by 92
Magnetocardiography for fetal arrhythmias
Strasburger, J. F., Cheulkar, B., & Wakai, R. T. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.02.035 · Cited by 81
Fetal MEG Redistribution by Projection Operators
Vrba, J., Robinson, S. E., McCubbin, J., Lowery, C. L., Eswaran, H., Wilson, J. D., Murphy, P., & Preibl, H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827265 · Cited by 81 · cited 1×
“The unwanted interference is projected out of the measurement in the temporal domain by constructing the OP operator from signal-space vectors corresponding to the interfering components—in this case mMCG (Vrba et al 2004).”
MethodSelf-citationBelfi, J., Bevilacqua, G., Biancalana, V., Cartaleva, S., Dancheva, Y. V., & Moi, L. (2007) · Journal of the Optical Society of America B · doi:10.1364/josab.24.002357 · Cited by 79
Recommended Standards for Fetal Magnetocardiography
Grimm, B., Haueisen, J., Huotilainen, M., Lange, S., Leeuwen, P. V., Menéndez, T., Peters, M. J., Schleußner, E., & Schneider, U. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00330.x · Cited by 76
Wakai, R. T., Lengle, J. M., & Leuthold, A. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/7/320 · Cited by 69
Flat-response spin-exchange relaxation free atomic magnetometer under negative feedback
Lee, H. J., Shim, J. H., Moon, H. S., & Kim, K. (2014) · Optics Express · doi:10.1364/oe.22.019887 · Cited by 61
The effect of changes in the conductive medium on the fetal ECG throughout gestation
Oostendorp, T. F., van Oosterom, A., & Jongsma, H. W. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/4b/002 · Cited by 60
Human MCG measurements with a high-sensitivity potassium atomic magnetometer
Kamada, K., Ito, Y., & Kobayashi, T. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/6/1063 · Cited by 57 · cited 1×
“…with atomic magnetometer) used one or two vapor cells with dimensions of 20 mm or larger (Livanov et al 1981, Bison et al 2003, Belfi et al 2007, Kim et al 2007, Kamada et al 2012) and systems have progressed to static arrays of several tens of sensors (Bison et al 2009, Lembke et al 2014).”
MethodOptical multichannel room temperature magnetic field imaging system for clinical application
Lembke, G., Erné, S. N., Nowak, H., Menhorn, B., Pasquarelli, A., & Bison, G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000876 · Cited by 53
Lowery, C. L., Campbell, J. Q., Wilson, J. D., Murphy, P., Preissl, H. T., Malak, S. F., & Eswaran, H. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2003.367 · Cited by 51
Self-citationIntegrated Approach for Fetal QRS Detection
Wilson, J. D., Govindan, R. B., Hatton, J., Lowery, C. L., & Preissl, H. T. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923916 · Cited by 49
Optimal reduction of MCG in fetal MEG recordings
McCubbin, J. A., Robinson, S. E., Cropp, R., Moiseev, A., Vrba, J., Murphy, P., Preissl, H. T., & Eswaran, H. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.876619 · Cited by 48
Self-citationOptically-Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2014) · Springer eBooks · doi:10.1007/978-3-642-33045-2_49 · Cited by 47
Self-citationGustafson, K. M., Allen, J. J. B., Yeh, H., & May, L. E. (2011) · Early Human Development · doi:10.1016/j.earlhumdev.2011.03.012 · Cited by 42
Reproducibility and reliability of fetal cardiac time intervals using magnetocardiography
Leeuwen, P. V., Lange, S., Klein, A., Geue, D., Zhang, Y., Krause, H., & Grönemeyer, D. H. W. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/011 · Cited by 37 · cited 2×
“But depending on GA these features have not been detected in averaged fMCGs recorded with SQUIDs either (van Leeuwen et al 2004).”
BackgroundResultFetal magnetocardiographic mapping using independent component analysis
Comani, S., Mantini, D., Alleva, G., Luzio, S. D., & Romani, G. L. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/6/011 · Cited by 32
Experimental fluid dynamics of aortic stenosis in a model of the human aorta
Yearwood, T. L., Misbach, G. A., & Chandran, K. B. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/1/002 · Cited by 30
Record of the Human Magnetocardiogram by the Quantum Gradiometer with Optical Pumping
Livanov, M. N., Koslov, A. N., Sinel'nikova, S. E., Kholodov, J. A., Markin, V. P., Gorbach, A. M., & Korinewsky, A. V. (2015) · Advances in cardiology · doi:10.1159/000391945 · Cited by 28
13th International Conference on Solid-State Sensors, Actuators and Microsystems
(2004) · IEEE Electron Device Letters · doi:10.1109/led.2004.838896 · Cited by 28
Kim, K., Lee, W., Kim, I.-S., & Moon, H. S. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.890610 · Cited by 23
Steinhoff, U., Link, A., Wiekhorst, F., Bäder, M., Knappe-Grüneberg, S., & Ackermann, R. (2005) · Computers in cardiology · doi:10.1109/cic.2005.1588138 · Cited by 5
Self-citation
Cited by
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
Portable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257
Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
Millimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85
Metadata
- Authors
- Alem, O., Sander, T. H., Mhaskar, R., LeBlanc, J., Eswaran, H., Steinhoff, U., Okada, Y., Kitching, J., Trahms, L., & Knappe, S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2015-06-04
- Volume
- 60
- Issue
- 12
- Pages
- 4797-4811
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2156217803
- Cited by
- 182
- References
- 44
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.