Fetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Following the rapid progress in the development of optically pumped magnetometer (OPM) technology for the measurement of magnetic fields in the femtotesla range, a successful assembly of individual sensors into an array of nearly identical sensors is within reach. Here, 25 microfabricated OPMs with footprints of 1 cm(3) were assembled into a conformal array. The individual sensors were inserted into three flexible belt-shaped holders and connected to their respective light sources and electronics, which reside outside a magnetically shielded room, through long optical and electrical cables. With this setup the fetal magnetocardiogram of a pregnant woman was measured by placing two sensor belts over her abdomen and one belt over her chest. The fetal magnetocardiogram recorded over the abdomen is usually dominated by contributions from the maternal magnetocardiogram, since the maternal heart generates a much stronger signal than the fetal heart. Therefore, signal processing methods have to be applied to obtain the pure fetal magnetocardiogram: orthogonal projection and independent component analysis. The resulting spatial distributions of fetal cardiac activity are in good agreement with each other. In a further exemplary step, the fetal heart rate was extracted from the fetal magnetocardiogram. Its variability suggests fetal activity. We conclude that microfabricated optically pumped magnetometers operating at room temperature are capable of complementing or in the future even replacing superconducting sensors for fetal magnetocardiography measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A blind source separation technique using second-order statistics
Belouchrani, A., Abed-Meraim, K., Cardoso, J.-F., & Moulines, E. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.554307 · Cited by 2,775 · cited 1×
“The second-order blind-identification algorithm (SOBI, TDSEP is a synonymous abbreviation) (Belouchrani et al 1997, Ziehe and Müller 1998) uses time-delayed covariance matrices Cτ of the form τ= ( ) ( + )τ x t x tC , ,i j t (3) where xi (xj) denotes the time series of the ith (jth) signal channel,…”
MethodHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441 · cited 1×
“Nevertheless, optically pumped magnetometers operating under similar conditions have previously been validated in standard two-layer MSRs for measurements of MEG (Johnson et al 2013, Shah and Wakai 2013) and fetal MCG (Wyllie et al 2012), as well as MEG in human size shield cans (Xia et al 2006).”
MethodA Review of Fetal ECG Signal Processing Issues and Promising Directions
Sameni (2010) · The Open Pacing, Electrophysiology & Therapy Journal · doi:10.2174/1876536x01003010004 · Cited by 410
Microfabricated alkali atom vapor cells
Liew, L.-A., Knappe, S., Moreland, J., Robinson, H., Hollberg, L., & Kitching, J. (2004) · Applied Physics Letters · doi:10.1063/1.1691490 · Cited by 374
Self-citationTDSEP — an efficient algorithm for blind separation using time structure
Ziehe, A., & Müller, K.-R. (1998) · Perspectives in Neural Computing · doi:10.1007/978-1-4471-1599-1_103 · Cited by 334
Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Magnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Self-citationFrequency-domain description of a lock-in amplifier
Scofield, J. H. (1994) · American Journal of Physics · doi:10.1119/1.17629 · Cited by 224
Cited by
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
Portable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257
Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
Millimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85
Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-34535-z · Cited by 79
1-pT Noise Fluxgate Magnetometer for Geomagnetic Measurements and Unshielded Magnetocardiography
Janosek, M., Butta, M., Dressler, M., Saunderson, E., Novotny, D., & Fourie, C. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2949205 · Cited by 70
Jensen, K., Budvytyte, R., Thomas, R. A., Wang, T., Fuchs, A. M., Balabas, M. V., Vasilakis, G., Mosgaard, L. D., Stærkind, H. C., Müller, J. H., et al. (2016) · Scientific Reports · doi:10.1038/srep29638 · Cited by 64
“Promising applications of atomic magnetometers include MEG 20 , detection of epilepsy 8 , detection of the synaptic responses in the retina, and cardiography of fetuses 6 .”
Zhang, R., Mhaskar, R., Smith, K., & Prouty, M. (2020) · Applied Physics Letters · doi:10.1063/5.0004746 · Cited by 48
“With the bandwidth of over 100 Hz, the gradiometer can be used for many applications such as nondestructive evaluation [20], unexploded ordnance (UXO) detection [21] and magnetocardiography (MCG) in an unshielded environment [22, 23, 24, 25].”
MethodSelf-citationEscalona-Vargas, D., Bolin, E. H., Lowery, C. L., Siegel, E. R., & Eswaran, H. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abc353 · Cited by 26
Self-citationOptimal magnetic sensor vests for cardiac source imaging
Lau, S., Petković, B., & Haueisen, J. (2016) · Sensors · doi:10.3390/s16060754 · Cited by 17
Metadata
- Authors
- Alem, O., Sander, T. H., Mhaskar, R., LeBlanc, J., Eswaran, H., Steinhoff, U., Okada, Y., Kitching, J., Trahms, L., & Knappe, S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2015-06-04
- Volume
- 60
- Issue
- 12
- Pages
- 4797-4811
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2156217803
- Cited by
- 182
- References
- 44
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.