Spatial and polarity precision of concentric high-definition transcranial direct current stimulation (HD-tDCS)
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Transcranial direct current stimulation (tDCS) is a non-invasive neuromodulation technique that applies low amplitude current via electrodes placed on the scalp. Rather than directly eliciting a neuronal response, tDCS is believed to modulate excitability-enhancing or suppressing neuronal activity in regions of the brain depending on the polarity of stimulation. The specificity of tDCS to any therapeutic application derives in part from how electrode configuration determines the brain regions that are stimulated. Conventional tDCS uses two relatively large pads (>25 cm(2)) whereas high-definition tDCS (HD-tDCS) uses arrays of smaller electrodes to enhance brain targeting. The 4 × 1 concentric ring HD-tDCS (one center electrode surrounded by four returns) has been explored in application where focal targeting of cortex is desired. Here, we considered optimization of concentric ring HD-tDCS for targeting: the role of electrodes in the ring and the ring's diameter. Finite element models predicted cortical electric field generated during tDCS. High resolution MRIs were segmented into seven tissue/material masks of varying conductivities. Computer aided design (CAD) model of electrodes, gel, and sponge pads were incorporated into the segmentation. Volume meshes were generated and the Laplace equation ([Formula: see text] · (σ [Formula: see text] V) = 0) was solved for cortical electric field, which was interpreted using physiological assumptions to correlate with stimulation and modulation. Cortical field intensity was predicted to increase with increasing ring diameter at the cost of focality while uni-directionality decreased. Additional surrounding ring electrodes increased uni-directionality while lowering cortical field intensity and increasing focality; though, this effect saturated and more than 4 surround electrode would not be justified. Using a range of concentric HD-tDCS montages, we showed that cortical region of influence can be controlled while balancing other design factors such as intensity at the target and uni-directionality. Furthermore, the evaluated concentric HD-tDCS approaches can provide categorical improvements in targeting compared to conventional tDCS. Hypothesis driven clinical trials, based on specific target engagement, would benefit by this more precise method of stimulation that could avoid potentially confounding brain regions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656 · cited 3×
“Transcranial direct current stimulation (tDCS) is a non-invasive neuromodulation technique that applies current through electrodes placed on the scalp (Nitsche and Paulus 2000).”
BackgroundInfluentialDatta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290 · cited 6×
“The applied constant current induces an electric fi eld in the cortex (Datta et al 2009, Wagner et al 2014) which in turn modulates excitability — enhances or suppresses neuronal activity in regions of the brain (Antal et al 2004).”
BackgroundMethodInfluentialSelf-citationAnodal transcranial direct current stimulation of prefrontal cortex enhances working memory
Fregni, F., Boggio, P. S., Nitsche, M., Bermpohl, F., Antal, A., Feredoes, E., Marcolin, M. A., Rigonatti, S. P., Silva, M. T. A., Paulus, W., et al. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-2334-6 · Cited by 1,159
Effects of non-invasive cortical stimulation on skilled motor function in chronic stroke
Hummel, F. (2005) · Brain · doi:10.1093/brain/awh369 · Cited by 1,114 · cited 1×
“…trials aim at a diverse range of clinical indications including depression treat-ment, pain control in patients with traumatic spinal cord injuries, motor rehabilitation, speech rehabilitation, and working memory (Fregni et al 2005, 2006, Hummel et al 2005, Baker et al 2010, Alonzo et al 2012).”
BackgroundBikson, M., Inoue, M., Akiyama, H., Deans, J. K., Fox, J. E., Miyakawa, H., & Jefferys, J. G. R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.055772 · Cited by 743 · cited 4×
“Predicted electric fi eld magnitude and intensity normal to the cortical surface were the primary outcomes based on the quasi-uniform assumption (Bikson et al 2013, 2015) and the presumed role of current direction (Bikson et al 2004, Rahman et al 2013).”
BackgroundMethodInfluentialSelf-citationRadman, T., Ramos, R. L., Brumberg, J. C., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.007 · Cited by 702 · cited 1×
“For cortical stimulation, it is theorized that electric fi eld normal to the surface produced optimal polarization of cortical neurons projecting along cortical columns such as layer 5 pyramidal neurons (Jefferys et al 2003, Radman et al 2009, Rahman et al 2013).”
BackgroundSelf-citationKuo, H.-I., Bikson, M., Datta, A., Minhas, P., Paulus, W., Kuo, M.-F., & Nitsche, M. A. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.09.010 · Cited by 695 · cited 2×
“…al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013) we note that 4 × 1 deployment is only one HD con fi guration and others have been implemented (Dmochowski et al 2013, Kempe et al…”
BackgroundSelf-citationFregni, F., Boggio, P. S., Lima, M. C., Ferreira, M. J. L., Wagner, T., Rigonatti, S. P., Castro, A. W., Souza, D. R., Riberto, M., Freedman, S. D., et al. (2006) · Pain · doi:10.1016/j.pain.2006.02.023 · Cited by 693
Optimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590
Self-citationTranscranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567 · cited 1×
“The following electrical conductivities (S/m) from a previous study were assigned to each of the tissues and electrodes: Skin 0.465, Fat 0.025, Bone 0.01, CSF 1.65, Gray matter 0.276, White matter 0.126, Air 1 × 10 15 , Electrodes 5.99 × 10 7 , and Gel 0.3 (Wagner et al 2007).”
MethodInfluentialCellular effects of acute direct current stimulation: somatic and synaptic terminal effects
Rahman, A., Reato, D., Arlotti, M., Gasca, F., Datta, A., Parra, L. C., & Bikson, M. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.247171 · Cited by 560 · cited 4×
“Predicted electric fi eld magnitude and intensity normal to the cortical surface were the primary outcomes based on the quasi-uniform assumption (Bikson et al 2013, 2015) and the presumed role of current direction (Bikson et al 2004, Rahman et al 2013).”
BackgroundMethodInfluentialSelf-citationUsing transcranial direct-current stimulation to treat stroke patients with aphasia
Baker, J. M., Rorden, C., & Fridriksson, J. (2010) · Stroke · doi:10.1161/strokeaha.109.576785 · Cited by 516 · cited 2×
“…trials aim at a diverse range of clinical indications including depression treat-ment, pain control in patients with traumatic spinal cord injuries, motor rehabilitation, speech rehabilitation, and working memory (Fregni et al 2005, 2006, Hummel et al 2005, Baker et al 2010, Alonzo et al 2012).”
BackgroundMethodEdwards, D., Cortes, M., Datta, A., Minhas, P., Wassermann, E. M., & Bikson, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.042 · Cited by 468 · cited 3×
“…explored extensively, speci fi cally using the 4 × 1 montage (Borckardt et al 2009, Datta et al 2009, Suh et al 2010, Caparelli-Daquer et al 2012, Edwards et al 2013, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015,…”
BackgroundMethodSelf-citationPeterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429 · cited 1×
“Across indications, the ability to guide current to speci fi c brain regions is assumed to underlie ef fi cacy and speci fi city and the current fl ow is determined by tDCS dose (de fi ned in Peterchev et al 2012) along with individual anatomy (Datta et al 2012).”
BackgroundSelf-citationDatta, A., Truong, D., Minhas, P., Parra, L. C., & Bikson, M. (2012) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2012.00091 · Cited by 404
Self-citationAntal, A., Kincses, T. Z., Nitsche, M. A., Bartfai, O., & Paulus, W. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0688 · Cited by 382
The electric field in the cortex during transcranial current stimulation
Miranda, P. C., Mekonnen, A., Salvador, R., & Ruffini, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.034 · Cited by 334 · cited 2×
“…and tDCS dosing strategies, with ongoing validation studies (Datta et al 2013, Villamar et al 2013a, Antal et al 2014) and also serves as a gold-standard to determine the relationship between tDCS dose and induced brain electric fi elds (Minhas et al 2012, Edwards et al 2013, Miranda et al 2013).”
BackgroundMinhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Self-citationVillamar, M. F., Volz, M. S., Bikson, M., Datta, A., DaSilva, A. F., & Fregni, F. (2013) · Journal of Visualized Experiments · doi:10.3791/50309 · Cited by 261 · cited 3×
“Previous modeling studies have identi fi ed characteristics of concentric HD-tDCS such as focality and polarity speci fi city (Datta et al 2009, Villamar et al 2013b), but a systematic study has yet to be published.”
MethodInfluentialSelf-citationAlonzo, A., Brassil, J., Taylor, J. L., Martin, D., & Loo, C. K. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.04.006 · Cited by 214 · cited 2×
“…trials aim at a diverse range of clinical indications including depression treat-ment, pain control in patients with traumatic spinal cord injuries, motor rehabilitation, speech rehabilitation, and working memory (Fregni et al 2005, 2006, Hummel et al 2005, Baker et al 2010, Alonzo et al 2012).”
BackgroundVillamar, M. F., Wivatvongvana, P., Patumanond, J., Bikson, M., Truong, D. Q., Datta, A., & Fregni, F. (2013) · The Journal of Pain · doi:10.1016/j.jpain.2012.12.007 · Cited by 194 · cited 3×
“Previous modeling studies have identi fi ed characteristics of concentric HD-tDCS such as focality and polarity speci fi city (Datta et al 2009, Villamar et al 2013b), but a systematic study has yet to be published.”
MethodInfluentialSelf-citationTruong, D. Q., Magerowski, G., Blackburn, G. L., Bikson, M., & Alonso-Alonso, M. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.05.011 · Cited by 183 · cited 2×
“We adapted previously developed head models (Datta et al 2012, Truong et al 2013).”
MethodSelf-citationInvestigation of tDCS volume conduction effects in a highly realistic head model
Wagner, S., Rampersad, S. M., Aydin, Ü., Vorwerk, J., Oostendorp, T. F., Neuling, T., Herrmann, C. S., Stegeman, D. F., & Wolters, C. H. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016002 · Cited by 177
Nikolin, S., Loo, C. K. A., Bai, S., Dokos, S., & Martin, D. M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.019 · Cited by 169 · cited 3×
“…× 1 montage (Borckardt et al 2009, Datta et al 2009, Suh et al 2010, Caparelli-Daquer et al 2012, Edwards et al 2013, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013).”
BackgroundAutomated MRI segmentation for individualized modeling of current flow in the human head
Huang, Y., Dmochowski, J. P., Su, Y., Datta, A., Rorden, C., & Parra, L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066004 · Cited by 162 · cited 1×
“A MATLAB script was then used to smooth artifacts and correct for discontinuities (Huang et al 2013).”
MethodTargeted transcranial direct current stimulation for rehabilitation after stroke
Dmochowski, J., Datta, A., Huang, Y., Richardson, J. D., Bikson, M., Fridriksson, J., & Parra, L. C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.049 · Cited by 162 · cited 2×
“…Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013) we note that 4 × 1 deployment is only one HD con fi guration and others have been implemented (Dmochowski et al 2013, Kempe et al 2014, Donnell et al 2015, Xu et al 2015).”
BackgroundSelf-citationCastillo-Saavedra, L., Gebodh, N., Bikson, M., Diaz‐Cruz, C., Brandao, R., Coutinho, L., Truong, D. Q., Datta, A., Shani‐Hershkovich, R., Weiss, M., et al. (2015) · Journal of Pain · doi:10.1016/j.jpain.2015.09.009 · Cited by 148 · cited 2×
“…× 1 montage (Borckardt et al 2009, Datta et al 2009, Suh et al 2010, Caparelli-Daquer et al 2012, Edwards et al 2013, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013).”
BackgroundSelf-citationDatta, A., Zhou, X., Su, Y., Parra, L. C., & Bikson, M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036018 · Cited by 145 · cited 1×
“Computational modeling is an accepted tool for predicting current fl ow and tDCS dosing strategies, with ongoing validation studies (Datta et al 2013, Villamar et al 2013a, Antal et al 2014) and also serves as a gold-standard to determine the relationship between tDCS dose and induced brain…”
MethodSelf-citationImaging artifacts induced by electrical stimulation during conventional fMRI of the brain
Antal, A., Bikson, M., Datta, A., Lafon, B., Dechent, P., Parra, L. C., & Paulus, W. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.026 · Cited by 136
Self-citationTranscranial direct current stimulation in pediatric brain: A computational modeling study
Minhas, P., Bikson, M., Woods, A. J., Rosen, A. R., & Kessler, S. K. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346067 · Cited by 126 · cited 1×
“…and tDCS dosing strategies, with ongoing validation studies (Datta et al 2013, Villamar et al 2013a, Antal et al 2014) and also serves as a gold-standard to determine the relationship between tDCS dose and induced brain electric fi elds (Minhas et al 2012, Edwards et al 2013, Miranda et al 2013).”
BackgroundSelf-citationRoy, A., Baxter, B., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2311071 · Cited by 125 · cited 3×
“…using the 4 × 1 montage (Borckardt et al 2009, Datta et al 2009, Suh et al 2010, Caparelli-Daquer et al 2012, Edwards et al 2013, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo…”
BackgroundMethodA pilot study on effects of 4×1 High-Definition tDCS on motor cortex excitability
Caparelli-Dáquer, E. M., Zimmermann, T. J., Mooshagian, E., Parra, L. C., Rice, J. K., Datta, A., Bikson, M., & Wassermann, E. M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346036 · Cited by 100 · cited 2×
“…is an embodiment that has been explored extensively, speci fi cally using the 4 × 1 montage (Borckardt et al 2009, Datta et al 2009, Suh et al 2010, Caparelli-Daquer et al 2012, Edwards et al 2013, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016,…”
MethodSelf-citationShekhawat, G. S., Sundram, F., Bikson, M., Truong, D., De Ridder, D., Stinear, C. M., Welch, D., & Searchfield, G. D. (2016) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968315595286 · Cited by 95 · cited 2×
“…Edwards et al 2013) but (Borckardt et al 2009, Caparelli-Daquer et al 2012, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013) we note that 4 × 1 deployment is only one…”
BackgroundSelf-citationBikson, M., Dmochowski, J., & Rahman, A. (2012) · Brain stimulation · doi:10.1016/j.brs.2012.11.005 · Cited by 93 · cited 3×
“Predicted electric fi eld magnitude and intensity normal to the cortical surface were the primary outcomes based on the quasi-uniform assumption (Bikson et al 2013, 2015) and the presumed role of current direction (Bikson et al 2004, Rahman et al 2013).”
BackgroundMethodSelf-citationA Pilot Study Investigating the Effects of Fast Left Prefrontal rTMS on Chronic Neuropathic Pain
Borckardt, J. J., Smith, A. R., Reeves, S. T., Madan, A., Shelley, N., Branham, R., Nahas, Z., & George, M. S. (2009) · Pain Medicine · doi:10.1111/j.1526-4637.2009.00657.x · Cited by 89 · cited 2×
“…nition (HD) tDCS con fi guration (4 × 1 HD-tDCS) has been explored as an alternative montage (Datta et al 2009, Suh et al 2009, Edwards et al 2013) but (Borckardt et al 2009, Caparelli-Daquer et al 2012, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al…”
BackgroundMethodHigh-Definition and Non-invasive Brain Modulation of Pain and Motor Dysfunction in Chronic TMD
Donnell, A., Nascimento, T. D., Lawrence, M., Gupta, V., Zieba, T., Truong, D. Q., Bikson, M., Datta, A., Bellile, E. L., & DaSilva, A. F. M. (2015) · Brain stimulation · doi:10.1016/j.brs.2015.06.008 · Cited by 78 · cited 2×
“…Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013) we note that 4 × 1 deployment is only one HD con fi guration and others have been implemented (Dmochowski et al 2013, Kempe et al 2014, Donnell et al 2015, Xu et al 2015).”
BackgroundSelf-citationModeling sequence and quasi-uniform assumption in computational neurostimulation
Bikson, M., Truong, D. Q., Mourdoukoutas, A. P., Aboseria, M., Khadka, N., Adair, D., & Rahman, A. (2015) · Progress in brain research · doi:10.1016/bs.pbr.2015.08.005 · Cited by 76 · cited 2×
“Predicted electric fi eld magnitude and intensity normal to the cortical surface were the primary outcomes based on the quasi-uniform assumption (Bikson et al 2013, 2015) and the presumed role of current direction (Bikson et al 2004, Rahman et al 2013).”
MethodSelf-citationFlood, A. P., Waddington, G. S., & Cathcart, S. (2016) · Journal of Pain · doi:10.1016/j.jpain.2016.01.472 · Cited by 72 · cited 3×
“…2012, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013) we note that 4 × 1 deployment is only one HD con fi guration and others have been implemented (Dmochowski et al…”
BackgroundEffects of weak electric fields on the activity of neurons and neuronal networks
Jefferys, J. G. R., Deans, J. K., Bikson, M., & Fox, J. (2003) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a006367 · Cited by 70 · cited 1×
“For cortical stimulation, it is theorized that electric fi eld normal to the surface produced optimal polarization of cortical neurons projecting along cortical columns such as layer 5 pyramidal neurons (Jefferys et al 2003, Radman et al 2009, Rahman et al 2013).”
BackgroundSelf-citationCathodal HD-tDCS on the right V5 improves motion perception in humans
Zito, G. A., Senti, T., Cazzoli, D., Müri, R. M., Mosimann, U. P., Nyffeler, T., & Nef, T. (2015) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2015.00257 · Cited by 46 · cited 2×
“…× 1 montage (Borckardt et al 2009, Datta et al 2009, Suh et al 2010, Caparelli-Daquer et al 2012, Edwards et al 2013, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013).”
BackgroundSuh, H. S., Kim, S. H., Lee, W. H., & Kim, T.-S. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333686 · Cited by 36 · cited 1×
“…the 4 × 1 concentric ring high-de fi nition (HD) tDCS con fi guration (4 × 1 HD-tDCS) has been explored as an alternative montage (Datta et al 2009, Suh et al 2009, Edwards et al 2013) but (Borckardt et al 2009, Caparelli-Daquer et al 2012, Bruny é et al 2014, Roy et al 2014, Heimrath et al…”
BackgroundReduced spatial focality of electrical field in tDCS with ring electrodes due to tissue anisotropy
Suh, H. S., Lee, W. H., Cho, Y. S., Kim, J.-H., & Kim, T. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626502 · Cited by 35 · cited 1×
“But, it is an embodiment that has been explored extensively, speci fi cally using the 4 × 1 montage (Borckardt et al 2009, Datta et al 2009, Suh et al 2010, Caparelli-Daquer et al 2012, Edwards et al 2013, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al…”
MethodRichardson, J. D., Fillmore, P., Datta, A., Truong, D. Q., Bikson, M., & Fridriksson, J. (2014) · NeuroRegulation · doi:10.15540/nr.1.1.62 · Cited by 34 · cited 1×
“Sham stimulation in tDCS is commonly applied as a relatively short (30 s) ramping of current at onset and offset with a period of no stimulation in between (Richardson et al 2014).”
BackgroundSelf-citationHeimrath, K., Breitling, C., Krauel, K., Heinze, H., & Zaehle, T. (2015) · European Journal of Neuroscience · doi:10.1111/ejn.12908 · Cited by 34 · cited 3×
“…(Datta et al 2009, Suh et al 2009, Edwards et al 2013) but (Borckardt et al 2009, Caparelli-Daquer et al 2012, Bruny é et al 2014, Roy et al 2014, Heimrath et al 2015, Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013)…”
BackgroundSimulating pad-electrodes with high-definition arrays in transcranial electric stimulation
Kempe, R., Huang, Y., & Parra, L. C. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026003 · Cited by 30 · cited 2×
“…Nikolin et al 2015, Shekhawat et al 2016, Zito et al 2015, Castillo-Saavedra et al 2016, Flood et al 2016, Kuo et al 2013) we note that 4 × 1 deployment is only one HD con fi guration and others have been implemented (Dmochowski et al 2013, Kempe et al 2014, Donnell et al 2015, Xu et al 2015).”
BackgroundBrunyé, T. T., Cantelon, J. A., Holmes, A., Taylor, H. A., & Mahoney, C. R. (2014) · Brain stimulation · doi:10.1016/j.brs.2014.09.015 · Cited by 25
Xu, J., Healy, S. M., Truong, D. Q., Datta, A., Bikson, M., & Potenza, M. N. (2015) · PubMed Central · Cited by 12
Self-citation
Cited by
Antal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationHuang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Self-citationIncomplete evidence that increasing current intensity of tDCS boosts outcomes
Esmaeilpour, Z., Marangolo, P., Hampstead, B. M., Bestmann, S., Galletta, E., Knotkova, H., & Bikson, M. (2018) · Brain Stimulation · doi:10.1016/j.brs.2017.12.002 · Cited by 200
“However, these HD-tDCS montages typically reduce the spatial extent of current in the brain rather than electric field intensity [47] and reinforce the role of the spatial distribution of current flow in influencing dose response rather than providing support for a dose-response itself.”
InfluentialSelf-citationMorya, E., Monte-Silva, K., Bikson, M., Esmaeilpour, Z., Biazoli, C. E., Fonseca, A., Bocci, T., Farzan, F., Chatterjee, R., Hausdorff, J. M., et al. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0581-1 · Cited by 166
Self-citationHill, A. T., Rogasch, N. C., Fitzgerald, P. B., & Hoy, K. E. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.001 · Cited by 105
“HD-tDCS consists of five small (~3 cm2) circular electrodes, with a central ‘active’ electrode which is placed over the target brain region, surrounded by four ‘return’ electrodes of opposite polarity (Alam et al., 2016; Datta et al., 2009; Villamar et al., 2013).”
Influential
Metadata
- Authors
- Alam, M., Truong, D. Q., Khadka, N., & Bikson, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2016-05-25
- Volume
- 61
- Issue
- 12
- Pages
- 4506-4521
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2396803757
- Cited by
- 197
- References
- 47
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.